Understanding Direct Lightning Stroke Shielding of Substations

Similar documents
Reduction of Lightning Caused Interruptions on Electric Power Systems Reduction Des Compures Dues a la Faudre Dans Les Reseaux

THE LIGHTNING PROTECTION INTERNATIONAL STANDARD

SANS : 2008 CODE OF PRACTICE THE WIRING OF PREMISES Part 1 : Low Voltage Installation

Transient and Lightning Protection for the Water Industries

Substation Grounding Study Specification

Lightning current simulation in the laboratory - parameters, procedures and test equipment -

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

LIGHTNING DETECTION IMPROVEMENT FALLS BROUGHT TO ESKOM S TRANSMISSION LINE DESIGN AND FAULT ANALYSIS

Study of Lightning Damage Risk Assessment Method for Power Grid

CHAPTER 6 INSTRUMENTATION AND MEASUREMENTS 6.1 MEASUREMENTS

Lightning Arresters P KVA P KVA. Description & Installation

U.S. Army Training and Doctrine Command. Guide for Lightning Protective Measures for Personnel. January 2002

Discussion on Class I & II Terminology. IEEE PES Transformers Committee Fall Meeting 2011 Boston, MA

Bourns Resistive Products

INTERNATIONAL STANDARD

Product Safety Considerations for Insulation Coordination of Low- Voltage Equipment. Scott Aldous, Compliance Engineer

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

EVALUATION OF CURRENTS AND CHARGE IN SURGE PROTECTIVE DEVICES IN LOW-VOLTAGE DISTRIBUTION NETWORKS DUE TO DIRECT LIGHTNING STRIKES

Presentation. Lightning Protection practices in Bangladesh :An overview

Version 1.1/ CTBTO/IMS Earthing and Lightning Protection Minimum Standard

Electrical Considerations for HVDC Transmission Lines. Joe Mooney, PE

New Distribution Class Arrester Ground Lead Disconnector Design Enhances Detonation Reliability and Improves Arrester Performance

Cellular Wireless Antennas

GroundRod AC Substation Earthing Tutorial

Lightning strikes onboard

Power surges can also be generated by equipment in your facility such as:

Coupling Effect in Substation Ground Measurements

EARTHING SYSTEM CALCULATION

WIRE AND CABLE ENGINEERING GUIDE

Fault location on power cables. Fault location on power cables

This is a preview - click here to buy the full publication TECHNICAL REPORT

DOES A STROKE BETWEEN CLOUD AND GROUND TRAVEL UPWARDS OR DOWNWARDS?

The following table shows approximate percentage wise the

Assessment of the Technical Issues relating to Significant Amounts of EHV Underground Cable in the All-island Electricity Transmission System

HOW TO SELECT VARISTORS

CATALOGUE SURGE PROTECTION LOW VOLTAGE

Electrical tests on PCB insulation materials and investigation of influence of solder fillets geometry on partial discharge

SURGE PROTECTIVE DEVICES

Current and Temperature Ratings

TAN δ (DELTA) CABLE TESTING OVERVIEW AND ANSWERS TO FREQUENTLY ASKED QUESTIONS. What Is Tan δ, Or Tan Delta?

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Coexistence of Automatic Weather Station (AWS) System in harsh environmental conditions at National Meteorological Centre (NMC) Colombo, Sri Lanka.

Telecommunication Line Protectors

Beware of Simplistic Voltage Drop Calculations. By Aaron Hesse, PE, Coffman Engineers, Spokane, Washington INTRODUCTION

V.A PJM Design and Application of Overhead Transmission Lines 69kV and Above

Acceleration levels of dropped objects

Between sky and earth

CUSTOMER REQUIREMENTS AT POWER SUBSTATIONS

CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN

Electrical Predictive and Preventative Maintenance

Selecting Receiving Antennas for Radio Tracking

Antenna Deployment Technical Brief

AS COMPETITION PAPER 2008

INTERNATIONAL STANDARD

Management Systems 10 Electrical Safety Audit 14 PPE 20 Arc Mitigation 22 Hazard Assessment 26

SECTION 22 LIGHTNING PROTECTION SYSTEM

Physics 25 Exam 3 November 3, 2009

Lightning Protection Introduction

Grounding of Electrical Systems NEW CODE: Grounding and Bonding

Avaya WLAN 9100 External Antennas for use with the WAO-9122 Access Point

Strength and Durability for Life CORROSION CONTROL. The Effect of Overhead AC Power Lines Paralleling Ductile Iron Pipelines

Bill is the author of 15 papers and lectures on transmission lines and other power system topics.

produces and delivers products worldwide can provide the optimal are dedicated to supplying you with superior advice and global support.

Transformer Bushings for GIS

Advancements in Lightning Test Services

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

HOW DOES A LIGHTNING ROD WORK? by MARTIN A. UMAN ORIGINALLY PUBLISHED IN

SAMPLE OF THE STUDY MATERIAL PART OF CHAPTER 3. Symmetrical Components & Faults Calculations

THE MINARET INCIDENTS AT PUTRAJAYA

EXTENDING THE LIFE OF POWER FACTOR CAPACITORS

ELEMKO reserves the right to modify, add or remove any information included in this catalogue, if necessary. Every updated version of the catalogue

Assessment of Soil Resistivity on Grounding of Electrical Systems: A Case Study of North-East Zone, Nigeria

Antenna Properties and their impact on Wireless System Performance. Dr. Steven R. Best. Cushcraft Corporation 48 Perimeter Road Manchester, NH 03013

Voltage Detection and Indication by Electric Field Measurement

Technical reference Key points

Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Data Assessment for Electrical Surge Protection Devices

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Testing of Power Transformers. Routine tests, Type tests and Special tests

City Of Ottawa High Voltage Substation Inspection, Maintenance Rev July 17 and Testing, ROPEC Page 1

Design Criteria Additions Related To PJM IPP R02 project

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F

Prof. Dr. Zahid A. Siddiqi, UET, Lahore WIND LOAD

The purposes of this experiment are to test Faraday's Law qualitatively and to test Lenz's Law.

Insulation Resistance Testing of Low Voltage Cables in the Field

RECOMMENDATION ITU-R P Method for point-to-area predictions for terrestrial services in the frequency range 30 MHz to MHz

Transmission Silicone Insulators Line Post 69 kv to 161 kv

Magnetic Field of a Circular Coil Lab 12

Understanding Range for RF Devices

Grounding Practice at Data and Communications Centers. David Brender, P.E., CPQ National Program Manager Copper Development Association Inc.

Candidate Number. General Certificate of Education Advanced Level Examination June 2014

Power Quality for Information Technology System

Transcription:

Understanding Direct Lightning Stroke Shielding of Substations P.K. Sen, Ph.D., P.E. Professor Division of Engineering Colo. School of Mines Golden, Colorado (303) 384-2020 psen@mines.edu PSERC Seminar Golden, Colorado November 6, 2001 2002 Colorado School of Mines

Understanding Direct Lightning Stroke Shielding of Substations Presentation Outline:! Lightning Stroke Fundamentals! Surge Protection and Surge Arresters! Design Parameters! Design Problem! Design Methods! Conclusions

Main Reference IEEE Std. 998-1996

Lightning Stroke Fundamentals (1) Several Theories have been advanced regarding the:! Formation of charge centers! Charge separation within a cloud! Ultimate development of lightning strokes Types of Lightning Strokes:! Strokes within clouds! Strokes between adjacent clouds! Strokes to tall structures! Strokes terminating on the ground

Lightning Stroke Fundamentals (2) Stroke Development: (Two-Step Process) 1. Ionization (Corona breakdown) of the air surrounding the charge center and the development of Stepped Leaders. 2. Development of a lightning stroke called Return Stroke. The total discharge of current from a thundercloud is called a Lightning Flash.

Lightning Stroke Phenomena Charge Distribution at Various Stages of Lightning Discharge Ref: IEEE Std. 998-1996 (Figure 2-2)

Lightning Stroke Fundamentals (3) Three Issues: 1. Usually the stroke consists of negative charge flowing from cloud to earth. 2. More than half of all lightning flashes consist of multiple (subsequent) strokes. 3. Leaders of subsequent strokes are called Dart Leader.

Effects of Direct Stroke on Substation Assumptions: No Shielding and No Surge Protective Devices. " Possible Insulation Flashover (depends primarily on the stroke current magnitude) " Damage (and possible failure) to Major Substation Equipment " Substation Outage " Cost Use of of Direct Stroke Shielding and Surge Arresters to to Minimize the Possibility of of Damage of of Equipment and Outage.

Surge Protection and Surge Arresters (1) 8 x 20 µs 1.2 x 50 µs Crest Value T 1 : Rise Time T 2 : Time to Half value Standard Current and Voltage Waveshapes to to Define Lightning for Laboratory Tests

Surge Protection and Surge Arresters (2) " Standard Lightning Voltage Test Wave: 1.2 x 50 µsec " Standard Lightning Current Test Wave: 8 x 20 µsec " BIL (Basic Impulse Insulation Level): A specified insulation level expressed (in kv) as the crest value of a standard lightning impulse. " CFO (Critical Flashover Voltage): Voltage (negative) impulse for a disruptive discharge around or over the surface of an insulator. BIL is determined statistically from the CFO tests. " Arrester Classes (Defined by Tests): # Distribution (Standard & Heavy Duty) # Intermediate # Station

Surge Protection and Surge Arresters (3) Metal Oxide Varistors (MOVs) Important Characteristics: " Maximum Continuous Operating Voltage (MCOV) " Temporary Over Voltage (TOV) " Lightning Discharge Voltage (IR) " Protective Level: Maximum Crest Value of voltage that appears across its terminals under specified conditions. " Volt-Time Characteristics

Surge Protection and Surge Arresters (4) Protective Margins: Three Protective Margins (PMs) are normally calculated. PM(1) = [(CWW/FOW) 1)] x 100% PM(2) = [(BIL/LPL) 1)] x 100% PM(3) = [(BSL/SPL) 1)] x 100% Where: CWW: Chopped Wave Withstand FOW: Front-of-Wave BIL: Basic Lightning Impulse Insulation Level LPL: Lightning Impulse Classifying Current (Also Called IR: Lightning Discharge Voltage) BSL: Basic Switching Impulse Insulation Level SPL: Switching Impulse Protective Level

Surge Protection and Surge Arresters (5) PM(1) PM(2) PM(3) Insulation Coordination Ref: IEEE Std. C62.22-1991 Ref: IEEE Std. C62.22-1991

Surge Protection and Surge Arresters (6) Lead Length Voltage: " For standard lightning surge current test waves (8 x 20 µs) the value is approx. 1.6 kv/ft. " For actual lightning current this value is between 6-10 kv/ft. di(t) v(t) = L dt L = 0.4 µη/ ft.

Effects of Direct Stroke on Substation Assumptions: Provide both Shielding and Surge Arresters. 1. Minimize the possibility of direct lightning strike to bus and/or major equipment in the substation and hence, the outage and possible failure of major electrical equipment. 2. Shielding may allow some smaller strokes to strike the buswork and equipment. Even though these strokes may not cause flashover, they may damage internal insulation systems of transformers, etc., unless they have proper surge arresters mounted at their terminals.

Effects of Direct Stroke on Substation Assumptions: Provide both Shielding and Surge Arresters (contd.). 3. Surge arresters will provide coordinated protection from lightning and switching surges for the internal insulation of power transformers, etc. 4. Arresters cannot effectively absorb very large stroke currents (arresters may fail, or discharge voltage become too high). 5. Arresters may not protect all of the buswork from lightning flashover, due to distance effect. 6. Lightning shielding can reliably intercept the large strokes, and can generally protect buswork from lightning flashover.

Design Parameters! Ground Flash Density (GFD)! Stroke Current! Strike Distance

Design Parameters Ground Flash Density (GFD) Ground Flash Density (GFD) : The average number of lightning strokes per unit area per unit time (year) at a particular location. Approximate Relationships: N k = 0.12 T d N m = 0.31 T d or N k = 0.054 T h 1.1 N m = 0.14 T h 1.1 Where, N k = No. of Flashes in Earth per sq. km N m = No. of Flashes in Earth per sq. mile T d = Average Annual keraunic level (thunderstorm-days) T h = Average Annual keraunic level (thunderstorm-hours)

Mean Annual Ground Flash Density (GFD) GFD (Flashes/km 2 /Year) Denver, Colorado GFD GFD = 6 Flashes/km 2 2 /year

Mean Annual Ground Flash Density Denver, Colorado Thunderstorm-days (T d ) = 42 Thunderstorm-hours (T h ) = 70 (GFD) N k = 0.12 T d = 0.12 x 50 = 6 (GFD) N k = 0.054 T 1.1 h = 5.8 From the Graph, (GFD) N k = 6/km 2 /year (Compare to the value of 2 on NW corner of Colorado and a Value of 18 in Central Florida)

Stroke Current Magnitude and Distribution P(I) = Probability that the peak current in any stroke will exceed I I = Specified crest current of the stroke (ka) Probability of Stroke Current Exceeding Abscissa for Strokes to Flat Ground Median Value of I: 31 ka for OHGW, Conductors, Masts & Structures 24 ka, Flat ground Stroke Current Range Probability for Strokes to Flat ground Ref. IEEE Std. 998-1996

Design Parameters Strike Distance S m = 8 (k) I 0.65 (m) or S f = 26.25 (k) I 0.65 (ft) I = 0.041 S 1.54 m (ka) Where, S m = Strike Distance in (meters) S f = Strike Distance in (ft) I = Return Stroke Current in (ka) k = Constant (Introduced in Revised Model) = 1, for strokes to wires or ground plane =1.2, for strokes to a lighting mast Strike Distance is the length of the final jump (last step) of the stepped leader as its potential exceeds the breakdown resistance of this last gap; found to be related to the amplitude of the first return stroke.

Strike Distance vs. Stroke Current Ref: IEEE Std. 998-1996

Design Problem! Probabilistic nature of lightning! Lack of data due to infrequency of lightning strokes in substations! Complexity & economics involved in analyzing a system in detail! No known practical method of providing 100% shielding! Lower Voltage (69 kv and Below) Facilities: Simplified Rules of Thumb! EHV (345 kv and Above) Facilities: Sophisticated (EGM) Study

Design Problem Four-Step Approach:! Evaluate the importance & value of the facility being protected and probable consequences of a direct lightning strike (Risk Assessment).! Investigate the severity & frequency of thunderstorms in the area of the substation facility and the exposure of the substation.! Select an appropriate design method (shielding and SA s).! Evaluate the effectiveness and cost of the design.

Design Methods (Commonly Used) 1. Empirical (Classical) Design a. Fixed Angles b. Empirical Curves 2. Electro-Geometric Model (EGM) a. Whitehead s EGM b. Revised EGM c. Rolling Sphere

Fixed Angles Method (1) (Examples) Protected objects Protected objects Fixed Angles for Shielding Wires

Fixed Angles Method (2) (Examples) Protected objects Protected objects Fixed Angles for Masts

Fixed Angle Methods (3) (Examples) Shielding Substation with Masts Using Fixed Angle Method (Ref: IEEE 998, Fig. B.2-3)

Fixed Angles Method (4) (Summary) 1. Commonly used value of the angle alpha (α) is 45 o. 2. Both 30 o and 45 o are widely used for angle beta (β). 3. Notes: " Independent of Voltage, BIL, Surge Impedance, Stroke Current Magnitude, GFD, Insulation Flashover Voltage, etc. " Simple design technique and easy to apply. " Commonly used in REA Distribution Substation design. " Has been in use since 1940 s. " For 69 kv and below produces very good results.

Empirical Curve Method (1) Developed in 1940 s (Experimental): Assumptions: 1. All lighting strokes propagate vertically downward. 2. The station is in a flat terrain. 3. Thunderstorm cloud base is at 1000 ft. above ground. 4. Earth resistivity is low.

Empirical Curve Method (2) Assumptions (contd.): 5. Based on Scale Model Tests. 6. Independent of Voltage Level. 7. Depends on the geometric relationship between the shield (or mast), the equipment, and the ground. 8. Independent of Insulation Level, Surge Impedance, Stroke Current Magnitude, and the Probability of Lightning Occurrence. 9. Designed for different shielding failure rates. A failure rate of 0.1% is commonly used.

Empirical Curve Methods (3) (Examples) Single Mast Protecting Single Object Derived from the Original Curves published by Westinghouse Researchers

Empirical Curve Methods (4) (Examples) Single Shield Wire Protecting Horizontal Conductors Derived from the Original Curves published by Westinghouse Researchers

Empirical Curve Methods (5) Summary : 1. Developed Experimentally in 1940 s. 2. Limited Applications Capabilities. 3. Modified Curves Developed in the IEEE Std. 998-1996. 4. Not Very User Friendly, Time Consuming and Used by Very Few. 5. Not Recommended Design Practice for EHV Substations.

Electrogeometric Method (1) 1. Whitehead s EGM Model 2. Revised EGM Model 3. Rolling Sphere Method Assumptions: a. The stroke is assumed to arrive in a vertical direction. B. The differing strike distance (value of k ) to masts, wires, and the ground plane are taken into considerations.

Electrogeometric Method (2) (Recommended EHV Transmission Substation and Switching Station) Allowable Stroke Current: I s = = s Or BIL x 1.1 2.2 (BIL) Z ( Z ) s 2 0.94 x CFO x 1.1 I s = = s 2.068 (CFO) Z ( Z ) s 2 Where, I s = Allowable Stroke Current in ka BIL = Basic Lightning Impulse Level in kv CFO = Negative Polarity Critical Flashover Voltage of the Insulation in kv Z s = Surge Impedance of the Bus System in Ohms

Electrogeometric Method (3) (EHV Transmission Substation and Switching Station) Procedure: 1. Calculate Bus Surge Impedance Z s from the Geometry. For two heights, use the higher level heights. 2. Determine the Value of CFO (or BIL). For higher altitude use correction factor for BIL. 3. Calculate the Value of I s. 4. Calculate the Value of the Striking Distance (or Radius of the Rolling Sphere) 5. Use Two or more Striking Distance Values based on BIL Voltage Levels in a Substation with two different voltages.

Electrogeometric Method (4) (Examples) Principle of Rolling Sphere

Electrogeometric Method (5) (Examples) Shield Mast Protection for Stroke Current I s

Electrogeometric Method (6) (Examples) Multiple Shield Mast Protection for Stroke Current I s

Electrogeometric Method (7) (Examples) Protection by Shield Wires and Masts

Electrogeometric Method (8) (Distribution Substation Below 115 kv) $ Shield spacing becomes quite close (by EGM method) at voltages 69 kv an below. $ For Voltage 69 kv and below, Select a minimum Stroke Current of 2 ka (also 3 ka has been recommended). $ According the data available 99.8% of all stroke currents exceed 2 ka. Lower possibility of flashover and lower consequences. Usually surge arrester will protect the transformer from any insulation damage. $ For, a 69 kv Design, BIL = 350 kv, Z s = 360 Ω Stroke Current (I s ) = 2.1 ka $ For, a 12.47 kv Design, BIL = 110 kv, Z s = 360 Ω Stroke Current (I s ) =0.67 ka $ Striking (Radius) Distance: # R sc = 41 ft (for 2 ka, k = 1) # R sc = 54 ft (for 3 ka, k = 1)

Electrogeometric Method (Applied to Building) Single Mast Zone of Protection Overhead Ground Wires Ref: NFPA 780, 1995

Electrogeometric Method (9) (Summary)! Originally, developed in the 1960 s for EHV (345 kv) Transmission Line Design and later Modified to include EHV Substation and Switching Station Design.! Major Difference (Fixed Angle and Empirical Methods) : Shielding design is based on the BIL (CFO), Surge Impedance, Lightning current probability distribution, lightning strike propagation, etc.! The EGM method is based on more scientific research and well documented theoretical foundation.! The basic EGM concept also has been modified and successfully adopted to protect building, power plant and other tall structures.! This method is recommended for large EHV substations and switching Stations in an area with high GFD values. Also very effectively used in 230 kv switchyard design.! Direct stroke shielding complemented by appropriately selected surge arrester provides the necessary protection.

Lightning Eliminating Devices (Active Lightning Terminals) References 1. IEEE Std. 998-1996, Section 6, pp. 42-43. 2. A.M. Mousa, The Applicability of Lightning Elimination Devices to Substations and Power Lines, IEEE Trans. on Power Delivery, Vol. 13, No. 4, October 1998, pp. 1120-1127. 3. D. W. Zipse, Lightning Protection Systems: Advantages and Disadvantages, IEEE Trans. On Industry Applications, Vol. 30, No. 5, Sept/Oct. 1994, pp. 1351-1361. 4. Many Others.

Lightning Eliminating Devices (Summary) 1. Ref [1]: There has not been sufficient scientific investigation to demonstrate that the above devices are effective, and these systems are proprietary, detailed design information is not available It is left to the design engineer to determine the validity of the claimed performance for such systems. It should be noted that IEEE does not recommend or endorse commercial offerings. 2. Ref [2]: Natural downward lightning flashes cannot be prevented. The induced upward flashes which occur on structures having heights (altitude of the peak) of 300 m or more can be prevented by modifying the needle-like shape of the structure. Some charge dissipater designs inadvertently accomplish this and hence appear to eliminate lightning. Such an effect has little or nothing to do with the existence of multiple points on those devices. Charge dissipaters will have no effect, whether intended or inadvertent, on the frequency of lightning strikes to tall towers where the altitude of the site is such that the effective height of the tower is less than about 300 m. Charge dissipaters will have no effect whatsoever on the frequency of lightning strikes to substations and transmission towers since such systems do not experience upward flashes.

Lightning Eliminating Devices (Summary) 3. Ref [3] NFPA has subdivided Standard 78 into two standards and has renumbered it. NFPA 780, entitled, The Lightning protection Code, and NFPA 781, Lightning Protection Systems using Early Streamer Emission Air terminal, are the new numbers and titles. NFPA 781 is under development and consideration. As stated above, there is little factual data available to substantiate the claims being made for the system. Many installations have been made. The owners have not inspected the systems for direct strikes, nor have any systems been instrumented. The lack of viable and repeatable testing, when compared to the NASA and FAA studies and the multitude of experts in the lightning field who claim the system fails to function as advertised, casts doubt on the effectiveness of the multipoint discharge system to prevent lightning strikes.

Conclusions (1) 1. Any design of Direct Lightning Stroke Shielding depends on the probabilistic nature of lightning phenomena. 2. There is no method available to provide 100% shielding against direct lightning stroke of the substation equipment and bus structures. 3. There are a number of other variables not addressed in the IEEE Std. 998-1996 and not discussed in this presentation, such as, effects of altitude on BIL, state (cleanliness) of the insulators, aging effect of equipment on failure, temperature variations, and so on. 4. Fixed angle method of design is quite adequate for distribution substations. EGM method is more appropriate for large and important substations at 230 kv and above voltage level.

Conclusions (2) 5. The applicability of Lightning Eliminating Devices to substation direct lightning stroke shielding requires additional data and research. 6. Proper grounding system design is also an integral part of the total solution and should be addressed during the design. 7. In order to arrive at some practical solutions, many assumptions are made in the different design techniques. 8. Surge Arresters are added in strategic locations in a substation to provide coordinated protection for all major equipment.