AxION 2 TOF MS. Time-of-Flight Mass Spectrometer

Similar documents
AxION edoor. Web-Based, Open-Access Mass Spectrometry Software

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS

TotalChrom. Chromatography Data Systems. Streamlining your laboratory workflow

Pesticide Analysis by Mass Spectrometry

DO MORE AND DO IT WITH CONFIDENCE. Empower 3 Chromatography Data Software

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

Micromass LCT User s Guide

Appendix 5 Overview of requirements in English

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Waters Core Chromatography Training (2 Days)

LC-MS/MS for Chromatographers

PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

AMD Analysis & Technology AG

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

Electrospray Ion Trap Mass Spectrometry. Introduction

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

Background Information

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening

Application of Structure-Based LC/MS Database Management for Forensic Analysis

The Use of Hydrogen Carrier Gas for GC/MS

SCION SQ Series GC-MS

MarkerView Software for Metabolomic and Biomarker Profiling Analysis

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS

Effects of Intelligent Data Acquisition and Fast Laser Speed on Analysis of Complex Protein Digests

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Thermo Scientific ExactFinder Software

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Time-of-Flight Mass Spectrometry

PRODUCT INFORMATION. Insight+ Uses and Features

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

IR READY TOGO. Spectrum Two FT-IR Spectroscopy

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

Signal, Noise, and Detection Limits in Mass Spectrometry

13C NMR Spectroscopy

How To Use An Ionsonic Microscope

WATERS QUANTITATIVE ANALYSIS solutions

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Mass Spectrometry Signal Calibration for Protein Quantitation

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

A Streamlined Workflow for Untargeted Metabolomics

Analytical Test Method Validation Report Template

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

ProteinScape. Innovation with Integrity. Proteomics Data Analysis & Management. Mass Spectrometry

MRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics

How To Build An Amd Quas 3 Ar Mass Spectrometer

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

designed to never let you down PerkinElmer Series 200 HPLC Systems

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

Alignment and Preprocessing for Data Analysis

Supplementary Materials and Methods (Metabolomics analysis)

The First Quantitative Analysis of Alkylated PAH and PASH by GCxGC/MS and its Implications on Weathering Studies

Mass Spectrometry. Overview

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM

Aiping Lu. Key Laboratory of System Biology Chinese Academic Society

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

A Navigation through the Tracefinder Software Structure and Workflow Options. Frans Schoutsen Pesticide Symposium Prague 27 April 2015

Discovery of Pesticide Protomers Using Routine Ion Mobility Screening

Q-TOF User s Booklet. Enter your username and password to login. After you login, the data acquisition program will automatically start.

Signal to Noise Instrumental Excel Assignment

The GeneAmp PCR System Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

How To Use Gc-Ms

ProteinPilot Report for ProteinPilot Software

Spectrum 10 Spectroscopy Software

Agilent LCMS products and the application strategies in veterinary drug analysis

Eleanor Riches Waters Corporation, Manchester, UK INTRODUCTION

imc FAMOS 6.3 visualization signal analysis data processing test reporting Comprehensive data analysis and documentation imc productive testing

ICH Topic Q 2 (R1) Validation of Analytical Procedures: Text and Methodology. Step 5

STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA

Introduction to Fourier Transform Infrared Spectrometry

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

The photoionization detector (PID) utilizes ultraviolet

LABWORKS Laboratory Information Management System. be confident. be informed. take control.

Tutorial for Proteomics Data Submission. Katalin F. Medzihradszky Robert J. Chalkley UCSF

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification

RAPID MARKER IDENTIFICATION AND CHARACTERISATION OF ESSENTIAL OILS USING A CHEMOMETRIC APROACH

Weight Loss Determined from Mass Spectrometry Trend Data in a Thermogravimetric/Mass Spectrometer System

TOF FUNDAMENTALS TUTORIAL

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

Amount of Substance.

Transcription:

AxION 2 TOF MS Time-of-Flight Mass Spectrometer

GREATER CONTROL GREATER INSIGHT GREATER CONFIDENCE Imagine being able to quantify with the power of exact mass. What would it mean to the depth of your sample insight? What would it do for the certainty of your results? How would it impact your productivity and bottom line? Now you can find out for yourself with the AxION 2 TOF MS from PerkinElmer. Every workflow is different. Every laboratory has unique demands on its instrumentation. Only the AxION 2 TOF MS delivers the ideal combination of mass accuracy, dynamic range, speed and sensitivity to optimize performance no matter what your application or sample matrix. Discover the flexibility and functionality of the AxION 2 TOF MS and see how it feels to quantify with complete confidence across the entire mass range. Everything You re Looking for in a Time-of-Flight Mass Spectrometer Unique ionization sources and TrapPulse technology ensure optimum sensitivity. Amplitude 3000 2500 2000 1500 1000 EIC 609.280 m/z S/N 77:1 Speed Exceptionally fast acquisition rates enable integration with the fastest LC separations for superior throughput. 0.007 mins (0.42 secs) 31 spectra across 0.42 secs Full Spectrum Measuring and recording every exact mass in each analysis allows you to reprocess data without re-running a sample. Amplitude 1200000 800000 400000 [Nal] 13 Na + [Nal] 16 Na + [Nal] 22 Na + 800 600 400 200 [Nal] 74 Na + [Nal] 89 Na + 0 10500 14000 m/z 500 0.374 0.381 [Nal] 30 Na + 4 5 6 7 Time (min) 8 9 0.350 0.400 Time (min) 0 0 12500 m/z 3 replicate injections of 1 pg reserpine. Fast LC analysis of reserpine. Direct infusion of sodium iodide. Mass Accuracy Exact mass capabilities and reliable isotopic ratio measurements deliver complete specificity for unambiguous sample insight. Dynamic Range Five orders of linear dynamic range, both intra- and inter-spectrum, provide absolute confidence in your results. Isotope Calculated m/z Observed m/z Calculated % Observed % ppm Error 1 609.28066 609.2816 100.00 100.00 1.54 9 8 y = 0.9803x + 3.2012 R 2 = 0.999 2 610.28393 610.2843 37.23 38.67 0.61 7 3 611.28671 611.2878 8.59 8.51 1.78 4 612.28941 612.2895 1.48 1.38 0.15 Log Area 6 5 4 Reserpine injection of 40 pg on column. 3 2 1 Software Robust yet intuitive solutions designed specifically to streamline and simplify individual workflows. -1 0 1 2 Log concentration (pg/µl) 3 4 5 Plot of 3 replicate injections of reserpine. 2

Different Workflows. Different Requirements. Same Instrument. The AxION 2 TOF MS offers a broad array of capabilities designed to simplify and streamline virtually any analytical workflow. Whether your application places an emphasis on the instrument s mass accuracy, full spectrum capability, speed, sensitivity, dynamic range, or all of the above, the AxION 2 TOF MS delivers exactly what you need to achieve confident, accurate results. Relative Analytical Importance 0% 100% Speed Full Spectrum Mass Accuracy Dynamic Range Software: AxION Data System Bringing Speed and Confidence to Quantitation Five orders of linear dynamic range and exact mass capabilities let you truly quantify compounds across a wide mass range. Intra-spectrum dynamic range allows the use of isotopic ratios for confident compound confirmation. The powerful, intuitive AxION data system gives you instant access to all tools and information, from quantitation and calibration curves to real-time viewing of lock-mass calibrated extracted ion chromatograms (EICs). Speed Full Spectrum Mass Accuracy Dynamic Range Software: AxION Solo Bringing Simplicity and Certainty to Target Analysis Full spectrum measurement in every analysis offers complete information for the screening of single targets or multiple compounds. Unrivaled mass accuracy and precise isotope ratios make it easy to find your target. Five orders of intra-spectrum dynamic range enable isotopic ratio pattern matching so you know you re screening the right compound. AxION Solo streamlines the most complex target analysis with a flexible, user-configurable and easy to interpret graphical interface for analyzing all of your targets and samples at the same time. Speed Full Spectrum Mass Accuracy Dynamic Range Software: AxION EC ID Bringing Efficiency and Accuracy to Compound Identification Wide dynamic range and exact mass capabilities make it easy to accurately identify unknown compounds. Full spectrum measurement captures the complete composition of every sample and allows you to check for any compound at any time. Isotopic ratio matching, capillary exit Collisionally Induced Dissociation and real-time lock mass calibration offer detailed structural insight allowing data mining without re-running your sample. User-friendly AxION EC ID software provides a ranked summary of formula matches, allowing the user to find the correct formula for their compound quickly and efficiently. www.perkinelmer.com/tofms 3

STATE-OF-THE-ART TECHNOLOGY UNRIVALED SENSITIVITY Engineered with an array of patented and proprietary technologies, the AxION 2 TOF MS offers exceptional sensitivity without compromising resolution or mass accuracy. Capable of spectacularly fast acquisition rates, the instrument integrates perfectly with the fastest LC separations to deliver better signal-to-noise ratios and higher throughput for a wide variety of compounds. Orthogonal Design Maximizes resolution and sensitivity while minimizing background chemical noise. Capillary Exit Collisionally Induced Dissociation (CID) Allows you to modulate the ion fragmentation under vacuum in a controlled and clean environment for more detailed structural elucidation. Patented Ion Sources Ensure ultimate sensitivity by delivering the most efficient nebulization and desolvation for the most effective ionization available. Patented Multi-Stage Ion Guide Maximizes ion transmission across multiple vacuum stages for superior sensitivity. V-Shaped Flight Path Delivers the resolution needed to solve the toughest analytical challenges while maintaining the highest levels of sensitivity. Electron Multiplier Detector Provides exceptional spectral integrity and superior peak resolution through a fast acquisition rate and wide dynamic range. AxION Separation Probe The innovative AxION Separation Probe facilitates chromatography directly at the ionization source. This minimizes dead volume effects in the system for superior signal-to-noise ratios, enhanced sensitivity and narrower peaks. 4

Proprietary Innovations for Superior Performance PerkinElmer has designed the AxION 2 TOF MS with a series of unique, cutting-edge technological innovations to optimize its performance and ensure it delivers an unsurpassed level of sensitivity and productivity. Industry-Leading Ionization Sources Allow you to select the ideal solution for a particular application or class of compound so you can optimize the instrument s performance under any analytical conditions. Both source types feature unique interchangeable snap-in probes that can be dedicated to specific applications, minimizing cross-contamination and enhancing productivity. Dual-probe Ultraspray 2 Electrospray Ionization (ESI) Dedicate one inlet to your sample and the other to an internal standard for real-time lock mass calibration enabling: -Enhanced mass accuracy. -Simpler method development. -Faster analysis times. Unique, grounded probe delivers the softest ionization available to preserve the molecular structure of the most labile compounds. Field-Free Atmospheric Pressure Chemical Ionization (APCI) Optimum performance at both high and low flow rates down to 50 ul/min without compromising sensitivity. Field-free design produces less noise and more reliable results than conventional sources. Simplest set up and operation with no needle or probe position optimization required. Patented Capillary Shutter Allows the capillary and entire source housing to be removed for maintenance without shutting down the vacuum. This capability eliminates the need to vent the system and the time required to bring it back up to vacuum ensuring greater instrument uptime and superior productivity. Unique to PerkinElmer, the shutter also prevents air from entering the instrument when the capillary is removed, eliminating any possibility of contamination. Proprietary TrapPulse Technology Increases sensitivity on average 10x by collecting dense packets of ions before accelerating them into the flight tube. The duty cycle of the pulser is synchronized with the arrival of the ion packets to ensure maximum ion transport to the state-of-the-art detector. Innovative and highly efficient, TrapPulse technology provides a higher amplitude signal and a reduction in baseline noise while maintaining exceptional resolution and mass measurement accuracy during Time-of-Flight MS acquisition. TrapPulse and Pulse Spectrum for 100 pg/µl Reserpine Direct Infusion 450000 400000 350000 300000 250000 200000 150000 100000 50000 0 608 608.5 609 609.5 610 610.5 611 611.5 612 612.5 613 TrapPulse Pulse By using the breakthrough TrapPulse technology on the AxION 2 TOF MS, you can typically experience a 10x increase in sensitivity (shown in blue) for clearer, more definitive results. Nitrogen Generator Our sophisticated LC/MS Nitrogen generator has Phthalate-free componentry with 24/7 continuous automatic operation. The generator also contains field-proven Pressure Swing Adsorption (PSA) technology, and is CE, UL & CSA approved. www.perkinelmer.com/tofms 5

SOFTWARE SOLUTIONS DESIGNED FOR THE WAY YOU WORK To complement the many hardware innovations of the AxION 2 TOF MS, PerkinElmer offers a variety of software solutions specifically designed to streamline and simplify today s laboratory workflows. Simply select the package best suited to your specific application and you ll discover an intuitive, robust interface offering everything you need to convert complex samples into confident results. AxION Data System for Quantitation Workflows The AxION data system simplifies everything from controlling your LC/TOF MS to accessing, managing, processing and reporting data. The software gets you up and running faster with the most advanced, one-click Time-of-Flight AutoTune. The only data system capable of providing real-time masscalibrated extracted ion signals (lock mass), it simplifies and optimizes method development to deliver faster, more reliable results for any compound-driven quantitative analysis. With the AxION data system, all the tools and information you need for confident quantitative analysis are within easy reach. Lock mass calibrated extracted ion chromatograms are displayed in real time for instant compound confirmation and optimized method development. Data from MS, PDA and analog detectors can be combined and displayed on screen. EICs can be graphically extracted from mass spectra in real time. All spectra are captured for each analysis for post-processing quantitation of additional masses. Built-in compound dictionary allows storage of user-specified compound names. 6

AxION Solo for Target Analysis Workflows The faster your processing, the quicker your results, and the sooner you can make decisions. That s the productivityenhancing power of AxION Solo. By allowing you to arrange and view windows to mimic your workflow whether it s for single or multiple target investigations the software makes it easy to maximize analytical throughput and minimize costs. A highly intuitive, compound-centric software, AxION Solo helps you quickly find what you re looking for graphically, clearly, accurately. AxION EC ID for Compound Identification Workflows Fast, accurate compound identification requires the ability to find the right formula quickly and efficiently. And nothing narrows your search more rapidly, simply or clearly than AxION EC ID (Elemental Composition Identification). Highly flexible and intuitive, this proprietary software takes the exact mass and isotope pattern data from the AxION 2 TOF MS and uses it to search for known formulas in various databases. Matched formulas are shown in a simple summary and scored according to your match parameters so you can quickly pick the correct one. AxION Solo displays multiple samples in a plate or vial view for quick, easy target identification. AxION EC ID converts exact mass data of unknown compounds to known formulas. Extensive reports and results publishing options. Broad array of data-evaluation parameters, including: - Found and pure/not found. - Found contains fragments. - Found and confirmed with isotopic ratios and retention time. Ability to view multiple samples in a plate or vial view and quickly identify your target in the samples. AxION Xpo For those requiring the reviewing and reporting functionality of AxION Solo but not its processing capabilities, AxION Xpo offers a compound-centric data-viewing environment in which to assess your results and customize your reporting. Matched formulas are shown in a ranked summary (based on theoretical accuracy and isotopic ratios) to help you choose the correct one. Mass error tolerance and isotope ratio matching criteria are user-defined. Simple and intuitive, the interface allows the generation of accurate, reliable results without in-depth elemental or chemistry knowledge. Each parameter match between observed and experimental data can be viewed by checking the Details box. www.perkinelmer.com/tofms 7

THE NUMBER ONE NAME IN SERVICE AND SUPPORT Nothing has a greater impact on productivity or return on investment than instrument uptime. And no one does more to ensure your chromatography and mass spectrometry systems perform day in and day out than PerkinElmer. With OneSource Laboratory Services, you have the world s largest and most respected global service and support network at your disposal. We go beyond just maintenance and repair of instrumentation. We incorporate laboratory asset management as part of our customers' business equation a partner with proven results in improving efficiencies, optimizing operations and providing cost certainty across the globe. No matter what you need, our team of certified, factory-trained Customer Support Engineers is just a phone call away, 24 hours a day, seven days a week. Operating in more than 150 countries with more than 400,000 assets currently under care, OneSource offers the most comprehensive portfolio of professional laboratory services in the industry, including complete care programs for virtually every technology and manufacturer. By allowing you to consolidate all your service contracts under a single supplier, and by providing responsive, expert technical advice and support at a moment s notice, we ensure your instrumentation and your lab is running at optimum levels at all times. Whether it s care and repair, validation and compliance, asset management and laboratory relocation, software and hardware upgrades or education and training, OneSource is the ONE you can count on. PerkinElmer, Inc. 940 Winter Street Waltham, MA 02451 USA P: (800) 762-4000 or (+1) 203-925-4602 www.perkinelmer.com For a complete listing of our global offices, visit www.perkinelmer.com/contactus Copyright 2012, PerkinElmer, Inc. All rights reserved. PerkinElmer is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners. 009990_01 Printed in USA