APT10 and APT14. for effective condensate drainage and removal

Similar documents
MFP14, MFP14S and MFP14SS Automatic Pumps

Direct steam injection humidifiers

VAD Variable Area Desuperheaters

Blowdown vessels Meeting the requirements of HSE PM60

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

VAD. Variable Area Desuperheaters

Desuperheater Online Program Sizing Guidance

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

Steam System Best Practices Condensate System Piping

Fig B36 Stainless Steel 'T' Type or Basket Type Strainers

FT43, FT44, FT46 and FT47 Ball Float Steam Traps

PBX Series Quick Fit Connector Bimetallic Steam Traps

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

QLM and QLD Series Three-port Control Valves

API Flanged Safety Relief Valves Series 526 CATALOG

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

Steam Coil Installation, Operation and Maintenance

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

SV615 Safety Valve. 1. Safety information. 2. Product information. 3. Supply. 4. Handling. 5. Before fitting the valve. 6.

Float and Thermostatic Traps Series H, C and X

CSF16 and CSF16T Stainless Steel Steam Filters

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

FLASH TANK ECONOMIZER PRODUCT GUIDE

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

In-Line Air Separators

61W - Wafer style resilient seated butterfly valve 61L - Lugged style resilient seated butterfly valve

REGULATING VALVE APPLICATIONS

Self-contained valve functions as integral check valve, flow sensing element and bypass control valve.

Check valves overview

ThermoStar Refrigeration Air Dryers

Waste Oil Handling, Spill Containment & Lighting

Air Eliminators and Combination Air Eliminators Strainers

Grey cast iron Fig. 600 Page 2. Forged steel High temperature steel Stainless steel Fig. 600/601 (Y) DN15-25 Page 4 DN40-50 Page 6

STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE

ThermoSorb Desiccant Dryers

WD600 STEAM TRAPS. Thermodynamic Steam Trap

Pressure reducing valves. for steam and industrial fluids

APCO SLOW CLOSING AIR/VACUUM VALVES

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

TN2000 Series Pneumatic Piston Actuators for DN125 to DN300 SPIRA-TROL Series Control Valves

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Grey cast iron SG iron Forged steel/ Cast steel Stainless steel Fig. 631 Page 2. High temperature steel Fig. 631 / Fig. 632 Page 8

Series description: Wilo-Yonos MAXO

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Steam Boiler Feedwater Storage Technology

heat transfer solutions Steam to Water Heat Transfer Packages for Domestic Hot Water

extreme applications as standard

OPTIMASS 6000 Technical Datasheet

Vertical selfpriming Side-Channel Pumps Type WPV

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

Nozzle Check Valves. NOREVA nozzle check valves are used

Hydraulic Control Solutions

Backflush filter R8-30W

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Refrigeration Compressed Air Dryer Buran Ultrapulse

Free Floating Lever Drain Traps For Loads to 50,000 lb/hr (22,679 kg/hr)...pressures to 1,000 psig (69 bar)

Type 92S Pilot-Operated Steam Regulator

COUNTERBALANCE VALVES

Automatic Back-Flushing Filter AutoFilt RF9.

Plant components, selected for sound performance

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

VALVES FOR REFRIGERATING SYSTEMS

High-efficient gas boiler CompactGas

Bypass level indicator With magnetic display Model BNA

Electronic Condensate Drains ECO-DRAIN Series

3M Housings DS Series

G. VULCANIZED SEAT Pressure sensitive seating with full disc overlap provides positive seating at high and low pressures.

Master Catalogue I August 2011

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

EJECTOR AIR REMOVAL SYSTEMS ENGINEERING DATA BULLETIN # PVS ARS PAGE 1 OF 5

SIOUX HYBRID WATER HEATER

VAG Non-Return Valves

Compact. Performance. Safety Relief Valves Serie 437 Serie 459. The-Safety-Valve.com

OPTIMASS 1400 Technical Datasheet

EcoStar Professional warewashing with integrated effi ciency and hygienic reliability

Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves

Commercial Semi-Instantaneous Water Heaters

Steam System Efficiency. Bill Lumsden Leidos Engineering

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

GS-General Service Control Valves

HS-901(A) BASIC STEAM HEATING SYSTEMS

08.08 Vic-Check Valves

Vacuum drying oven for non-flammable solvents

Heat recovery. Ian Matthews Sales & Marketing Director Gasco

Series description: Wilo-Yonos MAXO-D

C. starting positive displacement pumps with the discharge valve closed.

Steam System Design and Best Practices Related to Kiln Drying

Assisted lift operated 2/2-way solenoid valves Type EV250B

Micro Motion Model D and DL Coriolis Flow and Density Meters

TIMER CONTROLLED DRAINS

ECOCIAT. Domestic hot water heat recovery unit

KUNKLE SAFETY AND RELIEF VALVE PRODUCTS OVERVIEW

Types 66R and 66RR Low-Pressure Relief Valves

Corrugated Tubular Heat Exchangers

solarplus solar systems general features

Transcription:

APT10 and APT14 for effective condensate drainage and removal 1

An innovative solution for effective heat APT14, APT14HC and APT14SHC Compact design which contains all the equipment needed to drain or remove condensate for all load conditions. Innovative patent applied for low profile mechanism. Mechanisms operate with as little as 200 mm installation head from the base of the pump. APT10, APT14 and APT14HC - SG iron DIN EN JS 1025 (EN GJS 400-18LT) and ASTM A395 body and cover 3.1 certifiable. APT14SHC - Carbon steel EN 1.0619+N and ASTM A216 WCB body and cover 3.1 certifiable. The APT range is designed in accordance with DIN and ASME standards. Optional - The body and cover are available with an electroless nickel plate (ENP) finish. (Not APT14SHC) All stainless steel internals, with low profile robust stainless steel floats. High integrity trapped cover gasket. High capacity two stage trap module plus precision ball outlet check valve. The HC and SHC versions have a separate outlet disc check valve. Low resistance swing type inlet check valve. Positive snap action pump mechanism with replaceable valves and seats. Available connections: APT10-4.5 and APT14 (not HC and SHC) screwed BSP / NPT connections, with ½" screwed BSP or NPT motive fluid connections. The APT14, APT14HC and APT14SHC flanged PN16, ANSI 150, JIS / KS 10, with ½" screwed BSP or NPT motive fluid connections. 2

exchanger drainage APT - Automatic pump trap For over 50 years, Spirax Sarco has been involved with the design and manufacture of products for efficient condensate management. We have now developed a range of compact, condensate drainage systems in simple-to-install products. The APT has been designed to remove condensate from steam heat exchangers and process plant under all operating conditions, and forms an integral part of the condensate removal process. It is available in two easy-to-specify options: APT10-4.5 - for loads up to 1 500 kg/h; and APT14 or APT14HC and APT14SHC - for loads up to 9 000 kg/h. Compactness is the key The APT's are unique, from their compact size to their approved patent applied mechanisms. No other pressure operated pumps or traps in the world can offer all of the benefits shown on these pages. User benefits Self-contained compact unit. Operates with 0.2 m installation head from the base of the pump. Convenient installation to low mounted process equipment. Removes condensate under all load conditions, even vacuum. Requires no electrical power - suitable for hazardous environments. High capacity in one simple product package. Available with EN 10204 3.1 certification as standard. APT10-4.5 Electroless nickel plated (ENP) versions available. Approval to ATEX. Spirax Sarco s guarantee of worldwide technical support, knowledge and service. 3

1 The APT10-4.5, APT14, APT14HC and APT14SHC automatic pump traps operate on a positive displacement principle. enters the body through the inlet swing check valve causing the float to rise. The float is connected to the trap mechanism via a multi-link pivot. If the upstream system pressure PS is sufficient to overcome the backpressure PB (see below), the build up of condensate will be discharged through the opening two stage trap mechanism. In this way, the float will automatically modulate according to the rate of condensate entering the APT, controlling the rate of opening and closure of the trap. 1 Exhaust The working cycle of th 6 As the pressure inside the APT equalises with the condensate inlet pressure through the open exhaust valve, condensate re-enters via the inlet swing check valve. At the same time, the outlet ball check valve or the disc check valve (HC) ensures no condensate can drain back into the main chamber and the trapping or pumping cycle begins again. Exhaust 6 inlet (PS) outlet (PB) inlet (PS) PS outlet (PB) PB APT PS Exhaust 5 As the condensate level falls within the main chamber, the float re-engages the change over linkage, causing the motive inlet to close and the exhaust valve to open. inlet (PS) outlet (PB) 4 5

e APT10-4.5 and APT14 Exhaust 2 With some temperature controlled equipment, it is possible for the system pressure PS to be lower than the backpressure at PB. If this occurs a standard trap will stall allowing the condensate to flood the equipment being drained. 2 inlet (PS) outlet (PB) 3 However, with the APT, the condensate simply fills the main chamber - lifting the float until the changeover linkage is engaged, opening the motive inlet and closing the exhaust valve. 3 Motive steam inlet Secondary fl uid outlet Secondary fl uid inlet Motive steam inlet 4 4 The snap action mechanism ensures a rapid change from the trapping mode to the active pumping mode. With the motive inlet valve open, the pressure in the APT increases above the total back pressure and the condensate is forced out through the trap seat into the plant s return system. 5

Effective condensate drainage and removal is recovery Most condensate recovery is carried out using steam traps, which use differential pressure to discharge condensate back to the boiler house. If a higher backpressure exists in the return lines or they are simply mounted in an elevated position, then a steam trap will stall allowing condensate to flood back to the process. removal When the steam trap has stalled, an additional motive force is needed to actively remove the condensate from the process. Active condensate removal provides stable operating conditions, giving improved efficiency and prolonged equipment life. The APT provides a total solu Spirax Sarco s unique and innovative solution to condensate drainage and removal problems comes complete in a simple and compact package. APT's provide unrivalled control of steam utilising equipment, offering dual benefits of process efficiency and extended plant life. Simple to size, convenient to install, an APT forms an integral part of process and heating equipment drainage. These compact, fully automatic pump traps will ensure process plant or equipment remains totally drained of condensate under all operating conditions - even vacuum - optimising thermal efficiency of the heat exchange interface. 6 Efficient As the APT is designed for closed loop or sealed applications, there is no escape of steam to the plant room and no energy loss from flash steam, in fact, even the steam used for the motive supply is recycled back into the system. Optimum plant efficiency Effective condensate drainage and rem

essential for efficient steam plant operation Problems These can be some of the problems with simply trapping a heat exchanger: Poor heat transfer Irregular temperature control Corrosion Noise and waterhammer Tube failure High maintenance costs All too often these problems have remained unsolved because no fully engineered compact system was available. tion in one compact product Solution These products are specifically designed to automatically recover and remove condensate as soon as it forms. They provide the unique opportunity to solve all condensate handling problems. The result The APT will ensure your equipment operates as efficiently as possible - lowering energy consumption of the plant and allowing the process to run at optimum conditions - resulting in: Reduced costs. Increased productivity. Reduced downtime. Quieter equipment operation. reduces running costs. oval is crucial for peak performance. 7

Typical applications APT14 removal from process vessels and heat exchangers Designed for closed or sealed systems especially where space is limited. Removal of condensate under all pressure conditions ensures stable operating temperatures of the heat exchange interface. Tube corrosion, noise and waterhammer are all avoided - extending equipment life. removal from tube heat exchangers. (Closed system) - the APT is simply connected to the outlet of tube heat exchanger. No need for vacuum breakers the APT will drain condensate under all load conditions giving exceptional temperature control at the heat exchange interface. APT14 8 removal from vacuum equipment (Closed system) - Simple and efficient solution to a difficult problem. Without the need for high Net Positive Suction Head NPSH, the APT will operate with only 0.2 m installation head from the base of the pump, and remove condensate from a vacuum vessel, discharging it to either high or low level condensate return lines.* APT14 * Please note: These are typical applications only and some components have been omitted for clarity. Contact Spirax Sarco for full installation details.

APT10-4.5 APT10-4.5 removal from multi-heater applications (Closed system) - The APT can be used in single or multi-heater installations supplied by one control valve - as long as the total connected load is within the APT's capacity. Heater batteries are particularly prone to corrosion and freezing due to condensate retention. The APT provides the complete solution to traditional Air Handling Unit problems, and is ideal for any installation where head room is at a premium. Recommended installation NB. Motive steam supply must be trapped and free of condensate. For optimum performance it is recommended that the motive supply pressure is no more than 3 to 4 bar above the backpressure. Soft sealing check valve Secondary fl uid outlet Motive IN outlet The APT10s and APT14s are supplied with a 100 mesh strainer fi tted. APT14 Exhaust OUT inlet Spirax Sarco sized length of pipe to act as a reservoir Minimum installation head 0.2 m from base of pump. Maximum 1 m. It is recommended that the reservoir is installed at least 1 pipe diameter below the process outlet, but as high as possible above the APT inlet. Secondary fl uid inlet 9

How to size the APT... Simply contact your Spirax Sarco Spirax Sarco will ensure that the APT is accurately matched to your process and will provide you with a detailed sizing chart, tailored to your specific application. Providing the information below is known, we can even provide you with confirmation over the telephone and fax you your specific chart. Alternatively arrange a visit for your local Spirax Sarco representative who can provide detailed APT sizing information for all your specific needs. To help us size an APT for your application, up to 9 000 kg/h, simply provide us with the following information:- B D C E F H A G Installation head available from the base of the A pump to the centreline of the heat exchanger / process condensate outlet. m B Motive steam pressure available to power the pump trap. bar g C Pressure in the condensate return system. D Height of condensate return from fl oor level. E Heat exchanger full load operating pressure. F Maximum steam load on the heat exchanger. bar g m bar g kg/h G Minimum secondary fl uid temperature. C H Maximum controlled temperature of secondary fl uid. C 10

agent who can size an APT, for your specific needs. 11

Range and options Automatic pump trap Type APT10-4.5 APT14 and APT14HC APT14SHC Body material SG iron EN JS 1025 SG iron EN JS 1025 Carbon steel EN 1.0619+N or ASTM A395 or ASTM A395 or ASTM A216 WCB Body design rating PN10 PN16/ASME (ANSI) 150 PN16/ASME (ANSI) 150 Nominal size DN20 (¾") DN25 (1") DN40 (1½") APT10-4.5 and APT14 Inlet / outlet Inlet DN40 (1½") / DN20 (¾") outlet DN25 (1") - Inlet /outlet APT14HC and APT14SHC - Inlet DN50 / outlet DN40 Inlet DN50 / outlet DN40 connections Screwed BSP, NPT BSP, NPT - Flanged - PN16, ANSI 150, PN16, ANSI 150, JIS / KS 10 JIS / KS 10 Motive inlet / Motive inlet / Motive inlet / Motive fluid connections exhaust DN15 (½") exhaust DN15 (½") exhaust DN15 (½") Screwed BSP, NPT BSP, NPT BSP, NPT Self-contained stainless steel pump mechanism Minimum installation head from base of the pump 0.2 m Self-contained stainless steel trap mechanism Float operated single stage Float operated twin stage Float operated twin stage Inlet - swing check valve, Inlet - swing check valve, Self-contained APT10-4.5 and APT14 outlet - ball check valve outlet - ball check valve - stainless steel Inlet - swing check valve, Inlet - swing check valve, check valves APT14HC and APT14SHC - outlet - external disc check valve outlet - external disc check valve Maximum operating pressure 4.5 bar g 13.8 bar g 13.8 bar g Maximum backpressure 4.0 bar g 5.0 bar g 5.0 bar g Maximum operating temperature 155 C 198 C 198 C Nominal capacities Automatic pump trap Type APT10-4.5 APT14 APT14HC APT14SHC Pump discharge / cycle 2.1 litres 5.0 litres 8.0 litres 8.0 litres Maximum trapping capacity 1500 kg/h 4 000 kg / h 9 000 kg / h 9000 kg / h Maximum pumping capacity 575 kg / h 1100 kg / h 2 800 kg / h 2800 kg / h Total backpressure 2.5 bar g 1.0 bar g 1.0 bar g 1.0 bar g Reference conditions Motive pressure 4.5 bar g 5.0 bar g 5.0 bar g 5.0 bar g Installation head 1.0 m 1 m 1 m 1 m Some of the products may not be available in certain markets. Spirax-Sarco Limited, Charlton House, Cheltenham, Gloucestershire, GL53 8ER UK. Tel: +44 (0)1242 521361 Fax: +44 (0)1242 573342 E-mail: Enquiries@SpiraxSarco.com Internet: www.spiraxsarco.com Copyright 2008 Spirax Sarco is a registered trademark of Spirax-Sarco Limited 12 SB-P612-01 ST Issue 7