Buysafe Home Inspections Ltd

Similar documents
Self-Home Inspection Checklist

PRE-PURCHASE INSPECTION REPORT

Inspection Report. Dream Home Inspections Second Ave. Frisco CO (970)

Total Home Inspection Checklist

HOME INSPECTION CHECKLIST

October 5, 2015 Dear Client,

How To Prevent Water Damage To A Home

BUILDING INSPECTION REPORT for: SAMPLE BUILDING INSPECTION REPORT. Inspected Property: 90 Wentworth Street, SAMPLETON

Building Report. John Citizen. 1 Example Street Melbourne. Report Commissioned By: Property Address:

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

HouseCheck Inspection Report

Internal Dry Area Finishes for Major Defects & Significant Items

SCHEDULE OF CONDITION

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

(02) Peel Street TAMWORTH STANDARD INCLUSIONS (Residential)

Date of inspection 10/04/2014. Auckland Pre purchase - Condition report. Agent Present: Buyer Present: Weather at time of Inspection

Vision Home Inspection

CONDITION OF QUALITY ITEMS

PROPERTY INSPECTION REPORT

RESPONSIBILITY FOR REPAIRS AND MAINTENANCE FAIR FUNDING: April 2002

HEDDERMAN ENGINEERING, INC Carrie Cove Ct., Spring, TX , fax

Pest & Building Report

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

How to report a repair

SAMPLE INSPECTION REPORT PREPARED FOR: John Q Public


SCHEDULE OF FINISHES AMBLE RIDGE RETIREMENT VILLAGE

Vari Inspection Services

INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas

COMPREHENSIVE PROPERTY INSPECTIONS

U.S. Department of Housing and Urban Development Office of Public and Indian Housing. A Good Place to Live!

Cost Guide MARKET SUMMARY OVERVIEW REPAIRS AND MAINTENANCE ELECTRICAL ROOFING & ROOF DRAINAGE (UP TO TWO STOREYS; FIXED TO EXISTING ROOF FRAME)

Building Inspections Melbourne PH:

Inspecton Report. Property Address:

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: Inspection Date: Saturday, February XX, XXXX

Burns Home Services SUMMARY REPORT. 7/18/2006 Start: 9:00 am End: 12:30 pm

SPPI: Specialist Inspections NZS4306 Compliant Residential Property Inspection Specialist

Home Inspection Report

PROPERTY INSPECTION REPORT Property Address:

159 Morningside Avenue, Toronto

Code Enforcement Inspection Manual. City of Virginia Beach Department of Housing and Neighborhood Preservation Code Enforcement Division

Residential Inspection Guidelines

N.S.W. MASTER BUILDING INSPECTORS

Scope of works. Name Job# TBA -1. Project: Bathroom Renovation

PROFESSIONAL ENGINEERING INSPECTIONS, INC.

Simpson Engineering A state licensed engineering firm F-1607

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER

Inspection Agreement

STANDARD VISUAL PROPERTY INSPECTION REPORT Clients Name

Orlando Home Inspection Services

WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME

Home Inspection Report

A.C.E. Home Inspection Service St. Peters, MO (636)

Defining who is responsible for items and areas in a Strata Scheme

Crawford Inspection Services C.C.B. #

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

Pre-Drywall Inspection Report

Inspecting to a higher standard.

Dealing with damp and mould growth

Building Condition Assessment Report

RRIO Checklist. Use of checklist: Definitions: Limitations

EAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST

House Inspection Report

PLEASE REFER TO YOUR INDIVIDUAL QUOTE

Home Warranty Inspection Report

Inspection Item COMMENTS

PUBLIC MINUTES PROPERTY MAINTENANCE APPEALS BOARD. Wednesday, November 25, 2015, 3:46 p.m. Committee Room B, City Hall

Inspection Report. Prepared For: Sampath Sample. Property Address: Waterside Drive. Alpharetta, GA Atlanta Home Inspections

Residential Pre-purchase Inspection Report

I NI NP R Inspected Items

Our repairs and maintenance service

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

Building Condition Assessment Report

TENANT AND LANDLORD REPAIR RESPONSIBILITIES

#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check

BUILDING INSPECTION REPORT In accordance with AS

If there are any further questions with regards to the report or inspection, please call.

SNS Home Inspections LLC

Georgia Home Inspection Services

Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10

Exterior Condition Report

Inspection Tech. (330) Inspected By: Aaron Westerburg

home improvement service

Foundation Evaluation Report for PROPERTY ADDRESS Houston, Texas August 30, Prepared for:

Home Inspection Report

Accurate Home Inspection of Illinois. Property Inspection Report For Steve & Jenny Hynek 210 W.Chicago Ave., Westmont, Illinois

Home Inspection Report

Rehab Inspection Report Page 1

BUILDING INSPECTION REPORT In accordance with AS

Residential Pre-purchase Inspection Report

Owner Cleaning and Maintenance Checklist

Basic Mold Prevention

Home inspectors are not mold inspectors, however they do inspect for defects that

Inspection Report. provided by: Delaware Property Inspection. Inspector: Richard Hiddemen (302)

Home Inspection Report

ELIGIBLE REPAIR PROJECT PARAMETERS

Park View Place. Compass. House. Royal Wharf Gardens Endeavour. House. Thameside. Sienna. House. House. Apartments Townhouses.

GeorgiaHomePros.com Yellow Creek Road Ball Ground, GA Inspected By: Scott Webb

October 28, Re: Raleigh, NC Dear Mr. and Mrs.:

Terry Jenkins, Owner Member, American Society of Home Inspectors Virginia Certified Home Inspector Certificate # , expires 1/2010

Transcription:

Buysafe Home Inspections Ltd Client Name: Mr & Mrs Smith Address of Property Inspected: 123 Sea Road Auckland Date of Inspection: 11.00 am 05 August 2009 Page 1

Buysafe Home Inspections Contents Page Disclaimer...3 Executive Summary...4 Scope of Inspection...4 Moisture Readings...4 General House Condition...5 Pictures & Comments On Key Areas...5 Areas of Concern/Recommended Work to be Carried Out...8 Suggested Maintenance Schedule...8 Appendix One...9 Page 2

Disclaimer Buysafe Property Inspections (a division of A1 Renovation & Design Ltd) agrees to perform a visual inspection and to offer an opinion as to the general condition of various components of the building. The inspection is limited to accessible areas only. Inaccessible areas include, but are not limited to: behind walls, under carpeting, below soil, behind or under furniture or other obstructions, any areas with potential health or safety hazards, areas considered too small and areas where potential damage may result from inspector s activities. Also excluded from the inspection was an assessment of roofing, plumbing, electrical, the level of insulation and ventilation. The purpose and scope of this inspection is to provide you with a better understanding of the property s condition as observed at the time of the inspection. The inspector is limited by this inspection agreement and cannot be expected to find or discover all defects in the building. The client understands that the inspector did not build or perform work on this building and is not responsible or liable for anything other than the completion of the attached checklist and opinion on the areas reviewed. Our inspection may indicate that some reported items may require a specialist, such as a licensed electrician or plumber or other licensed person is needed to determine or repair deficiencies. We only inspect. We do not repair any items reported unless this is agreed separately, in addition to the completion of the inspection. Our inspection only includes those items mentioned above. The following are specifically excluded from this inspection: Pests and termites and insects of any kind, asbestos, lead, mould, fungi, formaldehyde, soil conditions, water filtration systems, wells, phone, cable, Sky satellite, window treatments, septic systems, and others beyond the scope of general visual building inspections. The inspection report is an opinion, and may be different than yours. We are not a home warranty company. This inspection is to reduce the risk of finding a potential problem, not to eliminate them. John Naisbett Buy Safe Home Inspections Ltd Page 3

Executive Summary The house was originally constructed in the 1950 s and in general, appears to be structurally sound and in fair condition for its age. The interior of the home is largely in what can be described as its original state and therefore is in need of extensive renovation and general modernising. Timber (rimu) flooring is carpeted in living areas with lino installed in all wet areas. The exterior of the house is cladded with brick and constructed on concrete and block work foundations. There is a 300mm soffit around the perimeter of the home and the roof consists of concrete tiles, in fair condition. There was no evidence of leaks in the roof and insulation (batts) is present in the ceiling. The aspects of the property that require attention have been explained in more detail in the body of the report. Our checklist (detailed in Appendix One) sets out what aspects of the property were looked at as part of our inspection process. Scope of Inspection Moisture readings were taken around windows and external doors only. In addition to this a visual inspection was carried out on accessible internal areas to offer an opinion as to the general condition of various components of the building including: windows, doorways, lintals, sills, condition of the hot water cylinder, bottom wall plates and general condition of the walls. Moisture Readings The table below shows the results from the moisture readings taken in the property (as noted above these were carried out on the windows and doors only): Window & door readings Reading All windows and doors range from 28 to 43 Readings of below 40 50 are within an acceptable range. Those between 50 to 70 can be of concern and readings over and above 70 require further investigation. Areas with moisture readings over 50 (note usually 40 is the acceptable level) should either be infrared camera tested and/or the Gib removed, areas exposed and the insulation viewed to determine if it is wet and requires replacement. Dampness can rot bottom wall plates and cause a mouldy/mildew smell. Page 4

General House Condition Interior parts of the interior show signs of Gib cracking, especially in the areas situated on the colder aspects of the property. Recommended work includes: Garage Main Garage door does have large gap at top, this will let cold air into the house, and maybe even a little water. Also sighted oil on floor at rear of garage. Bathrooms Tile floors, note no under floor heating has been installed. Also note no ceiling fans to exhaust shower moister out. Sighted minor crack in wall, tested with moister scanner - readings came through acceptable. Bedroom/Office - Wardrobe doors need minor adjustment to roller catch. Bedroom door also needs adjusting. My only concern is in the office outside wall there has been a TV cable drilled right through the wall, we do NOT Recommend this as water can get in and travel inside causing major rot. Should you purchase the property it would be our recommendation to keep a close eye on this - we did carry out a moisture test in the general area and the results appeared reasonable and we did note that it had been siliconed from the outside. There were also signs of minor Gib cracks, this in itself is no concern and can often occur when the house settles over the years. Kitchen - Only real comment is we noted a gap under the kitchen cabinet (between the floor and the skirting) under the sink, however this is of no real concern. Hot water cylinder This is a Rheem system which is classed as a good cylinder. Year of manufacture 1990 Exterior the exterior of the property is Brick Which has a cavity of 60mm this is normal for a brick home On visual inspection there were no signs of cracks, however it was noticed at the rear of the house as per photo above the window will need replacing due to a crack in the corner and timber rot. Also the spouting down pipe connection has rusted away and lastly the gulley trap is blocked. Joists and bearers these were checked and appeared to be in good condition. However one of the concrete beams has a large crack, this will need urgent attention. Pictures & Comments On Key Areas Flashing broken down Garage side door rotting at bottom Page 5

Odd window in aluminium Toilet window glass louvers jammed Office door requires adjusting Bedroom light has no power to it Loose tiles around window area paint flaking Page 6

Spouting pipe Rusted away Garage ceiling is aesbestos Bathroom Lino damp here Copper hot water pipes need lagging Switch board is very old & will Need updating this can be costly. The oven rear elements do not work. Page 7

Areas of Concern/Recommended Work to be Carried Out Further to the points raised in the section above, we have listed below suggestions regarding work to be carried out on the property: Decks: This has been built with a drop of only 40mm from the house floor level with a slight fall to an internal gutter to the outside. A close eye will need to be kept over this as if the internal gutter ever blocks (and if a build up occurred) water could come through to into the house - council used to require a 60mm drop from the house floor level to the top of the tiles (or decking) and have since changed this to be 100mm firm. Bathroom: Fans should be fitted for the shower to remove moisture or keep a window open/or install a skylight. Note was not able to check wall and ceiling insulation is all in place due to NO ceiling access. Roof This needs water blasting and top ridge will need replacing due to a lot of cracks and badly installed, looks like this has been temporally fix up Note missing four main lounge light bulbs. As discussed, we recommend you obtain a LIM report for the property also as this will highlight any information contained on council records that you should be aware of. Suggested Maintenance Schedule Should you go ahead and purchase the property, we have set out below our suggestion regarding ongoing maintenance required to keep the property in reasonable condition: Interior Checks/Work Required Frequency Joinery Paintwork to be kept in good condition Repaint every 3 4 years particularly on the northerly aspects Bathroom Keep tiles clean & free from mould & mildew. Monthly Ensure extraction fans are used & windows are opened regularly to increase airflow. Get any signs of dampness checked asap Laundry Dryers should have extraction fans fitted & Annually these should flow to the exterior of the building. Check connections do not have drips/slow leaks. Hot Water Cylinder Check for signs of leaks Annually Exterior Guttering Clean out all gutters & drains regularly Every 2 3 months Paths & Driveways Keep clear of moss Spray/waterblast annually Brickwork Keep clean & watch for cracking. Ensure Annually washout areas are kept clean & free from soil Roof Check for loose tiles & clean to prevent mould Annually & moss build-ups Garage Keep rollers & tracks greased Annually Foundations Make sure the air vents are kept clear to allow Annually air flow to reach these areas Page 8

Appendix One A-Very Good B-Good C Will Need Attention Soon D Need Attention Now R- Needs Minor Repairs MR- Mayor Repair Required STAIRS No doors Hand Rails No handrails fitted FAMILY ROOM Sliding doors need adjusting GARAGE Garage Door Adjust door gap s Painted (Remove oil) Loft Nil BATHROOM Tiles, no under floor heating Vanity Shower Toilet Bath A-Very Good B-Good C Will Need Attention Soon D Need Attention Now R- Needs Minor Repairs MR- Mayor Repair Required Page 9

LOUNGE Outside door has dropped (as indicated on picture) s Missing 4 light bulbs DINING ENTRANCE Front Door s MASTER Window need repairs ENSUITE Small crack between window and shower Requires an exhaust fan Shower Wardrobe A-Very Good B-Good C Will Need Attention Soon D Need Attention Now R- Needs Minor Repairs MR- Mayor Repair Required Page 10

BEDROOM 2 Door will need adjustment BEDROOM 3 TV wire right through wall KITCHEN s Cabinetry Gap under sink cabinet Bench Tops Hobb/Oven Not tested Very old Wastemaster Not fitted Rangehood Not working LAUNDRY Rot on bottom of window Door HALLWAY Cupboards s A-Very Good B-Good C Will Need Attention Soon D Need Attention Now R- Needs Minor Repairs MR- Mayor Repair Required Page 11

SITE Slope Fencing Paths/Driveways Just side path Surface Water DECKS & Material Tiles Piles Joists Decking Tiles EAVES Soffit Fascia Gutter Downpipes Rusted out ROOF Material Concrete tiles Slope Flashings Penetrations ROOF SPACE Construction ) Unable to access this Dampness ) area as no man-hole Insulation ) in sight Insects & Pests ) Rotting Timbers ) A-Very Good B-Good C Will Need Attention Soon D Need Attention Now R- Needs Minor Repairs MR- Mayor Repair Required Page 12

NORTH Cladding Plaster over hardibacker Joinery Aluminium Base Cladding Block work EAST ELEVATION Cladding Joinery Base Cladding WEST ELEVATION Cladding Joinery Base Cladding SOUTH ELEVATION Cladding Joinery Base Cladding A-Very Good B-Good C Will Need Attention Soon D Need Attention Now R- Needs Minor Repairs MR- Mayor Repair Required Page 13