SPPI: Specialist Inspections NZS4306 Compliant Residential Property Inspection Specialist

Size: px
Start display at page:

Download "SPPI: Specialist Inspections NZS4306 Compliant Residential Property Inspection Specialist 0800 920 009 www.sppi.co.nz"

Transcription

1 Inspection Details: Comprehensive Plaster Cladding Inspection Non-invasive Moisture Testing Infrared Thermal Imaging Weather-tightness Assessment Builders Report Inspection Address: Presale inspections are commissioned by the vendor for prospective Purchasers. The only difference between a Presale and Pre-purchase inspection is that the client details are TBC (to be confirmed). Reference: SAMPLE REPORT Date: SAMPLE REPORT Time of Inspection: 9:30AM Weather: No rain during the 48 hours prior to inspection House Status: Occupied Client: TBC see following page for Pre-Sale Inspection details Client Contact Number: TBC see following page for Pre-Sale Inspection details Report was commissioned by the owner for prospective buyers and is transferable. See for transfer charges. SPPI PO Box Green Bay Waitakere 0643 Auckland Inspector: Mark Drew NZS 4306 Compliant Building Inspectors Member of Master Builders Association Member of Building Officials Institute of NZ ISO Qualified Thermographer Professional Indemnity Insurance: Policy Number: NI/02778/000/12/D Public Liability Insurance: Policy Number: BPS-005 Page 1 of 22

2 Table of Contents: Inspection Information: SPPI have been commissioned to preform a Comprehensive Pre-Sale Builders Report with NonInvasive Moisture Testing and Infrared Thermal Imaging Inspection. SPPI guarantee Full Disclosure of any issues set out under the NZS4306:2005 SPPI agrees to copies of the report to prospective purchasers on request, to ensure the authenticity of the contents of the report. SPPI will be available at a mutually convenient time to discuss by phone any questions prospective purchasers, their legal advisers, financial adviser s or contractors may have. This report is transferable. See our web site for transfer charges. 1. Cover Page: 2. Table of Contents: 3. Summary: 4. Weather-tightness Assessment: 5. Moisture Testing: 6. Ground to Cladding Clearances TCFC Cladding: 7. Deck Boundary Joists Further Investigation/Remedial Work: 8. Roof to Wall Junctions Risk Awareness: 9. Ground to Cladding Clearances Brick Veneer: 10. Internal Deck Further Investigation: 11. Fascia Concealed Internal Gutter System Risk Awareness: 12. Preventative Maintenance Joinery: 13. Infrared Thermal Imaging: 14. Exterior Cladding: 15. Plaster Cladding Maintenance Guidelines: 16. Roof / Roof Space: 17. Site/Services: 18. Internal Inspection: 19. Internal Inspection Wet Areas: 20. Certification: 21. Glossary: 22. Terms and Conditions: General Inspection Details: All properties have cosmetic imperfections and general wear and tear. SPPI's inspections are to NZS4306:2005 Standards: Under NZS4306:2005 guidelines our inspection and reporting are for; Significant Defects Significant Maintenance Gradual Deterioration Particular Attributes Weather-tightness Issues The condition of the property stated in our report is reflective of the age and style of the property. Page 2 of 22

3 Summary: All properties have cosmetic imperfections. SPPI's inspections are to NZS4306:2005 Standards: Under NZS4306:2005 guidelines our inspection and reporting are for; Significant Defects Significant Maintenance Gradual Deterioration Particular Attributes Weather-tightness issues Overall: The property requires some remedial work and/or preventative maintenance to ensure that the property can maintain an acceptable level of weather-tightness.see pages 6-11 for details The property has general wear and tear consistent with its age and style. The property is in an acceptable condition for its age and style. Weather-tightness Risk Assessment: The property requires some remedial work and/or preventative maintenance to ensure that the property can maintain an acceptable level of weather-tightness. Once suitably addressed the property can maintain an acceptable level of weather-tightness on the condition that the property is kept well maintained. Moisture Detection/Remedial work and/or Preventative Maintenance: There were poor ground to cladding clearances at the N/East corner adjacent to the Laundry/Bathroom/Garage. Internal Inspection of the adjacent areas recorded high moisture readings and/or signs of moisture ingress in the Laundry and Garage. The bath was installed against the wall with poor ground to cladding clearances adjacent to the bathroom and was not able to be checked at the time of inspection. See page 6 for details. The Deck Boundary Joist was fixed against the TCFC cladding which can be problematic with moisture ingress. Internal Inspection of the adjacent areas showed signs of moisture ingress under the stairs and high moisture readings adjacent to the rear entrance. See page 7 for details. Preventative Maintenance: The Roof to Wall Junctions require resealing and installing suitable Kick out Flashings where applicable. See page 8 for details. The gardens have been installed above the weep holes on the Brick Veneer cladding adjacent to the Office and Garage. Recommend that the gardens are lowered so that the weep holes are clear and unobstructed. See page 9 for details. The deck parapet wall has the guard-rail top fixed through the parapet which has no suitable camber. To address this particular attribute (risk area) the parapet wall will require suitable camber and cap flashing and the guard-rail to be face fixed on the outside of the parapet wall. See page 10 for details Recommend having the corner windows checked and resealed if required. See page 12 for details. Page 3 of 22

4 Weather-tightness Assessment: Particular Attributes: Particular Attributes (at risk areas) are included in our report under the NZS:4306 regardless of whether they have moisture ingress issues at the time of inspection. This enables you the prospective purchaser through awareness of the risk areas to assess not only the condition of the property on the day of inspection but also take into consideration the particular attributes (at risk areas) associated with the property. It also gives you the purchaser the information to plan risk management of the areas in the form of regular routine checks, regular scheduled maintenance or preventative maintenance. General Building Assessment: Wind Zone: Indications are open wind zone Site Exposure: Exposed Complexity of Design: Medium Complexity of Design Number of Stories: Multiple Story Number of Cladding Types: Multiple cladding types Roof Planes: Multiple Roof Planes Monolithic cladding: Brick Veneer is not a monolithic cladding system TCFC is a monolithic cladding system Cavity System: Brick Veneer has a cavity system TCFC does not have a cavity system Eaves: The property has acceptable eave cover Particular Attributes (Risk Areas): Ground to Cladding Clearances. See pages 6&9 for details. Deck Boundary Joist against the cladding. See page 7 for details. Roof to Wall Junctions. See page 8 for details. Internal Deck. See page 10 for details. Fascia concealed internal gutter system. See page 11 for details. Moisture Testing and Visual Inspection Results: Visual Signs of Moisture Ingress and/or High Moisture Readings: Garage/Laundry. See page 6 for details. Stairwell. See page 7 for details. Summary: The property requires some remedial work and/or preventative maintenance to ensure that the property can maintain an acceptable level of weather-tightness.see pages 6-11 for details The property has general wear and tear consistent with its age and style. The property is in an acceptable condition for its age and style. Page 4 of 22

5 Moisture Testing General Information: Location: Maximum Reading: Meter: Summary: Visual See page 10 for details. Resistance See page 6 for details Ground Floor: Garage Visual Laundry 32% Bathroom Common 37 Bedroom S/West 27 Master Bedroom Office 38 Front Entrance 37 Bedroom N/East 29 Ensuite Stairwell 50% Resistance See page 7 for details First Floor: Toilet 33 Kitchen 38 Family 37 Dining 35 Lounge 36 Moisture Testing Equipment and Moisture Test Result Explanations: SPPI have three different moisture testing meters. We have Capacitance only meter, a Resistance only meter and a dual Capacitance / Resistance combination meter. Capacitance Dielectric Meter Readings Trotec T650 and Extech MO257 of below 50 are within normal industry guidelines for timber framing and gib board lining. Capacitance Dielectric Meter Readings Protimeter Surveymaster of below 150 are within normal industry guidelines for timber framing and gib board lining. Resistance Moisture Meter Readings Trotec T500 & Protimeter Surveymaster of 18% and below are within normal industry guidelines for timber framing and gib board lining. SPPI have a range of meters giving us the equipment to cross reference inspection results helping eliminate false readings and substantiate high moisture readings. Moisture Readings Summary: The property requires some remedial work and/or preventative maintenance to ensure that the property can maintain an acceptable level of weather-tightness.see pages 6-11 for details Page 5 of 22

6 Ground to Cladding Clearances TCFC Cladding: General Information: Ground to Cladding Clearance can be problematic with wicking, which is when moisture migrates up the cladding to the properties framing. TCFC cladding is the most susceptible and problematic with poor ground to cladding clearances and wicking. General Description: There were poor ground to cladding clearances at the N/East corner adjacent to the Laundry/Bathroom/Garage with the cladding in contact with the permanent paving. Internal Inspection: Internal Inspection of the adjacent areas recorded high moisture readings and/or signs of moisture ingress in the Laundry and Garage. The bath was installed against the wall with poor ground to cladding clearances adjacent to the bathroom and was not able to be checked at the time of inspection. Further Investigation: Recommend Further Invasive Investigation which require removing the gib board to determine if there is any moisture damage to the framing and remedial work required if any. Expected Scope of work would include installing a grate and channel drain to address the ground to cladding clearances. General Observations: The gully trap is below ground level which is against council regulations and will need to be addressed during remedial work, General Information: Remedial work needs to be carried out by a suitably qualified licensed tradesman. Remedial work needs photos and documentation of the work carried out including the LBP number of the tradesman for us to be able to amend remedial work into our report. Page 6 of 22

7 Deck Boundary Joists Further Investigation/Remedial Work: General Description: The Deck Boundary Joists/Ribbon Plate are fixed directly against the cladding which can be very problematic with TCFC cladding. The TCFC cladding relies heavily on its plaster and paint for weather-tightness. The issue with the Deck Boundary Joists being fixed against the cladding is that moisture can become trapped between the cladding and Deck Boundary Joists which depending on the paint and plaster condition (which will deteriorate of time) can lead to moisture ingress through the Fibre cement board sheet and/or sheet joins causing moisture ingress and possible gradual deterioration of the Sub-floor and/or properties framing. Internal Inspection: Internal Inspection of the adjacent areas showed signs of moisture ingress under the stairs and high moisture readings adjacent to the rear entrance. Further Investigation/Remedial work: Recommend that the boundary joists/joists are removed from the TCFC cladding and that the plaster cladding is repaired and painted as required. General Information: Remedial work needs to be carried out by a suitably qualified licensed tradesman. Remedial work needs photos and documentation of the work carried out including the LBP number of the tradesman for us to be able to amend remedial work into our report. Page 7 of 22

8 Roof to Wall Junctions Risk Awareness: General Description: Roof to Wall Junctions are risk areas with all cladding types. It is very important that special attention is paid to these areas during scheduled exterior house painting and maintenance to ensure that the junctions remain well sealed. Kick out Flashing: Roof to Wall Junctions on this property did not have suitable Kick out Flashings installed and are relying largely on sealant for there weather-tightness which is against good trade practice. Internal Inspection: Internal Inspection of the adjacent areas using moisture testing, visual and thermal imaging recorded no obvious signs of moisture ingress or high moisture readings. Preventative Maintenance: Recommend installing Kick out Flashings and/or resealing the Roof to Wall Junctions. Scope of work would require that the cladding at the Roof to Wall Junction is removed and reinstated when the Kick out Flashing is installed. Recommend inspection of the framing during this process and if there are any signs of moisture ingress or damage Further Invasive Investigation would be required which would involve removing the gib board at the adjacent areas to check the framing for possible moisture damage. General Information: Remedial work needs to be carried out by a suitably qualified licensed tradesman. Remedial work needs photos and documentation of the work carried out including the LBP number of the tradesman for us to be able to amend remedial work into our report. Page 8 of 22

9 Ground to Cladding Clearances Brick Veneer: General Information: Brick Veneer exterior cladding has weep holes which allow the cavity system to function correctly. The weep hoes need to be kept clear and unobstructed. General Description: The gardens adjacent to the Garage and Office are higher than the internal finished floor level and are covering the weep holes. Internal Inspection: Internal Inspection of the adjacent areas where accessible showed no obvious signs of moisture ingress, damage or high moisture readings. Preventative Maintenance: Recommend there the gardens are lowered to an acceptable level where the weep holes of the Brick Veneer and clear and unobstructed. This should be relatively easy and can be done by a home handyman. No further investigation is required at the time of inspection. Page 9 of 22

10 Internal Deck Further Investigation: Genral Description: Internal Decks are a risk area with all cladding types due to the fact that if they do leak moisture ingress is inside the building line. Water-proofing thresholds were minimal under the joinery but acceptable for the age and style of the property. Deck to cladding clearances were acceptable for the age and style of the property. Guard-rail height was acceptable. Parapet walls had poor Camber Parapet walls had the guard-rail top fixed through the parapet wall. Water proofing membrane was Viking Dec-K-ing PVC vinyl water proofing membrane. Information supplied shows that the water proofing membrane was replaced 12/02/2015. workmanship and manufacturers warranties are available for viewing through the listing agent. Internal Inspection: Internal Inspection of the adjacent areas showed signs of moisture damage to the ceiling in the Garage. Further Investigation: There was signs of moisture damage to the ceiling which require further investigation to determine if moisture damage is current or historic and if there is any remedial work required. Recommendation: The deck parapet wall has the guard-rail top fixed through the parapet which has no suitable camber. To address this particular attribute (risk area) the parapet wall will require suitable camber and cap flashing and the guard-rail to be face fixed on the outside of the parapet wall. Page 10 of 22

11 Fascia Concealed Internal Gutter System Risk Awareness: General Description: Fascia Concealed Internal Gutter System is an internal gutter system. The associated risk with a Fascia Concealed Internal Gutter System is that if they become blocked or leak moisture egress is often into the eave and usually inside the building line which can cause a gradual deterioration if undetected. It is important with internal gutter systems that the gutters are kept clear and unobstructed. Recommend gutters are cleaned at least annually before winter. Overflows: The Fascia Concealed Internal Gutter System on this property have overflows before. Internal Inspection: Internal Inspection of the adjacent areas using moisture testing, visual and thermal imaging recorded no obvious signs of moisture ingress or high moisture readings. Preventative Maintenance: Not Required. Page 11 of 22

12 Preventative Maintenance Joinery: There were signs of moisture ingress to the sills of the corner windows. Recommend that that the joinery is checked by window repair specialist and resealed if required. Trade Link: Window repair specialist. Venture contratcing Page 12 of 22

13 Infrared Thermal Imaging Inspection: Analysis of the Infrared images showed no thermal anomalies which require further investigation which have not already been identified. Page 13 of 22

14 Exterior Cladding: Primary Base Cladding: Brick Veneer is a low maintenance cladding system with a proven history for durability and weather-tightness. Primary First Floor Cladding: Texture Coated Fibre Cement (TCFC) is a fibre cement board approximately 7.5mm thick and fixed directly to the framing over building paper. A texture coating is then applied which is approximately 3mm thick. TCFC relies heavily on its paint and plaster finish for weather-tightness and needs to be kept well maintained. Monolithic Cladding: Brick Veneer is not a monolithic cladding system TCFC is a monolithic cladding system Cavity System: Brick Veneer has a cavity system TCFC does not have a cavity system Cladding Condition: Cladding was in an acceptable condition. Plaster Finish: Plaster was in an acceptable condition. Paint Finish: Paint was in an acceptable condition. Mid-Section Banding: Not applicable Control Joints: Not applicable Ground to Cladding Clearances There were poor ground to cladding clearances at the N/East corner adjacent to the Laundry, Bathroom and Garage which require further investigation. See page 6 for details. The gardens have been installed above the weep holes on the Brick Veneer cladding adjacent to the Office and Garage. Recommend that the gardens are lowered so that the weep holes are clear and unobstructed. See page 9 for details. Joinery: Joinery Description: Aluminium joinery was in an acceptable condition. Joinery to Cladding Junction: Joinery to cladding junctions were acceptable Joinery Head Flashings: Head flashings were acceptable Joinery Sill Detail: Joinery sills had suitable camber and were well sealed where applicable. Foundation: Concrete foundations with a concrete ground floor. Summary: Exterior was structurally sound and had a good overall level of weather-tightness. Page 14 of 22

15 Plaster Cladding Maintenance Guidelines: General Cladding Description Texture Coated Fibre Cement (TCFC) relies heavily on its paint and plaster for weather-tightness. Specialist inspections SPPI recommend that Exterior painting and sealing is done by suitably qualified licenced tradesman experienced in the repair and painting of plaster cladding systems. Key Areas: It is important that the cladding to joinery junctions are kept well sealed, this includes removing the old sealant in conjunction with scheduled exterior house painting. Joinery to cladding sealing is as important as the exterior painting. It is important that any penetrations through the cladding are correctly re-sealed. Paint Details: An Elastromeric paint is required to be used for plaster cladding. Recommended paint: Dulux AcraTex Elastomeric 201 Paint Colour: It is important that the elastromeric paint has a Light Reflective Value (LRV) of over 40 is used.. Texture Coated Fibre Cement is susceptible to cracking when painted with colours with a LRV of under 40 (Dark colours) are used due to the thermal expansion and contraction of the Fibre Cement Board which can cause cracks in the sheet joins and in some cases pop nails. Remedial Work / Maintenance: Specialist Inspections SPPI recommend that maintenance is carried out by suitably qualified licenced tradesman experienced in the maintenance, painting, sealing and remedial work of monolithic cladding. Specialist Inspections (SPPI) recommend that any hairline cracks sighted are professionally repaired. This involves grinding out the cracks and if required re-fixing and installing a fiberglass reinforcing mesh to strengthen the joint in combination with applying Flexi Plast to safe guard against further cracking. Annual Maintenance: Specialist Inspections (SPPI) recommend that the exterior cladding has a low pressure chem wash to ensure that the paint and plaster are kept in good condition. Recommended tradesman Recommended Plaster Cladding Repair and Painting Specialist: Elite Exteriors: Shafraz shafraz@eliteexteriors.co.nz Page 15 of 22

16 Roof / Roof Space Inspected Comments Roof Description: Concrete roof tiles have a proven history as a durable roof system with a good level of weather-tightness. Roof Condition: Roof was in an acceptable condition. Roof Pitch: Indications are roof material is acceptable for the pitch of the roof. Roof Flashing's: Roof flashings were acceptable Penetrations: Penetrations were acceptably sealed Bedding and Pointing: Bedding and pointing was in an acceptable condition. Gutters: Fascia-style (hidden) guttering systems can be problematic of moisture ingress into the building line if they leak or get blocked. The risk with the Fascia concealed internal gutter system is that if they become blocked typically the back of the gutter is the lowest point and the point where moisture would ingress into the soffit. If the soffit has even a slight fall towards the building this is where any moisture will track. It is important that the internal gutters are kept clear and unobstructed. Recommend gutters are cleaned at least annually before winter. Down-pipes: PVC Down-pipes were in an acceptable condition. Soffit's / Eaves: The property had acceptable eave cover Roof Space: Roof Substrate: Insulation: Roof and Ceiling design meant there was no accessible roof space for inspection. It was mandatory to install insulation in the ceiling and walls at the time of construction. There was no evidence to suggest insulation has not been installed HRV: Not present Roofing underlay: Summary: Roof and Roof Space were in an acceptable condition with a good overall level of weathertightness. Page 16 of 22

17 Site: Driveway: Driveway was in an acceptable condition. Permanent Paving / Paths Permanent Paved areas were in safe and stable condition Fences: Fences were in an acceptable condition. Landscaping: Established in an acceptable condition. Storm water: Cesspit installed were clear and unobstructed with no signs of blockages at the time of inspection. The majority of plumbing, drainge and stormwater systems are hidden in wall cavities or under ground therefore we can not give an opinion on there functionality or effectiveness. There were no signs of blockage or discharges sighted to indicate that there are any drainage or stormwater problems. For a specialist drainge and stormwater inspection contact: Drain Surgeons Ltd Services: Power Supply: Underground Power Supply Water supply: Metered town supply Gas: LPG gas bottle supply present not tested. Switchboard: Circuit-breakers Electrical Wiring: TPS wiring was installed where sighted Plumbing / Drainage: Plumbing Waste: PVC waste pipes were in good condition and well sealed with no obvious signs of leaks or damage at the time of inspection. Gully Traps: Gully traps were clear and unobstructed at the time of inspection. Gully trap at the N/West Deck Timber: Substrate: The Deck Boundary Joist at the rear entrance is fixed directly against the cladding. See page 7 for details. Decking: Decking was in an acceptable condition. Stairs: Treads and stringers were structurally sound and were in an acceptable condition. Retaining Walls: Retaining Walls: Timber Retaining walls had acceptable verticality and alignment with no obvious signs of damage or repair recorded. The main structure of retaining walls are under ground therefore we can not make any representations as to the structural integrity of the retaining walls. Page 17 of 22

18 Internal Inspection: With all properties of this age there will be cosmetic imperfections and general wear and tear, our inspection is for significant defects. Internal inspection covers all living, family and bedrooms. Specific rooms will not be mentioned unless there are moisture ingress and/or damage, remedial work or further investigation required Inspected Comments Walls: Painted Gib board or similar walls were in an acceptable condition. Ceilings: Painted Gib board or similar ceilings were in an acceptable condition. Floor Coverings: Floor coverings were suitable for there application and were in an acceptable condition. Doors: Internal doors were in an acceptable condition. Joinery: Joinery was in an acceptable condition. Alarm: Alarm Present not tested Fire Detection: Present not tested Garage Door: Garage was in a working condition at the time of inspection. Kitchen: Kitchen Cabinetry: Kitchen cabinets were in an acceptable condition. Kitchen Bench Top: Kitchen bench top and sink were in an acceptable condition. Oven: Wall oven present not tested. Hobs: Gas hobs were in a working condition at the time of inspection. Waste Disposal: Waste disposal was in a working condition at the time of inspection. Extraction Fan: Extraction fan was in a working condition at the time of inspection. Dishwasher: Dishwasher was Present not tested Summary: Interior was in an acceptable condition for the age and style of the property. Page 18 of 22

19 Internal Inspection Wet Areas: Inspected Comments Bathrooms/En-suites: Flooring: Floor coverings were suitable for there application and were in an acceptable condition. Toilets: Toilets were in an acceptable condition. Showers: Showers were in an acceptable condition. Baths: Bath was in an acceptable condition. Vanities: Vanities were in an acceptable condition. Laundry Moisture Testing: There were high moisture readings in the Laundry which require further investigation to determine the source of moisture ingress damage if any and remedial work required if any. The high moisture readings are adjacent to poor ground to cladding clearances. See page 6 for details. Flooring: Floor coverings were in an acceptable condition. Tubs/Cabinetry: Laundry tub was in an acceptable condition. Hot Water Cylinder: Electric hot water cylinder. Rheem Year of manufacture: 1994 Capacity: 180 litre Pressure: Mains Summary: Wet areas were in good overall condition Page 19 of 22

20 Certification: I hereby certify that I have carried out the inspection of the property at Address: SAMPLE REPORT Reference: SAMPLE REPORT Date: SAMPLE REPORT In accordance with NZS4306:2005 and that I am certified to undertake this inspection. Signature: Inspector: Mark Drew Managing Director SPPI Certified Building Inspector NZS4306:2005 Member Master Builders Association Member Building Officials Institute of NZ ISO Qualified Thermographer Professional Indemnity Insurance Policy #NI/02778/000/12/D Public Liability Insurance Policy # BPS-005 Important Note: Public Liability and Professional Indemnity Insurance are not house insurance or home warranty insurance cover. House and Contents Insurance Cover is recommended if you purchase this or any property. Limitations: The client shall assume all risk, for any conditions or problems that may be concealed at the time of inspection. No item shall be dismantled, moved, or dislodged during the inspection, and there will be no destructive testing undertaken. An investigation of the condition and location of underground drainage and services and of hidden electrical, gas and plumbing is not included. No invasive or destructive inspection methods have been used in the assessment and concealed work can not be inspected, therefore no opinion or warranty can be offered in respect of the said concealed work. An inspection carried out in accordance with NZS4306:2005 is not a statement that a property complies with the requirements of any act, regulation or by-law, nor is the report a warranty against any problems developing after the date of this report. Page 20 of 22

21 Glossary: Particular Attributes Explanation: It has been well publicised that plaster clad properties can have issues. Every issue we find can be directly attributed to an architectural detail fault, an application fault or lack of routine maintenance. Plaster cladding does not fail for no reason. Particular Attributes are areas which have been identified that can be problematic with moisture ingress issues. Regardless of whether these areas have No high moisture readings No signs of moisture ingress No signs of significant damage Under the NZS4306:2005 we have to include these areas in our report. This enables you as a prospective purchaser through awareness of the areas to assess any risk involved. It also gives you the purchaser the information to plan risk management of the areas in the form of regular routine checks and regular scheduled maintenance. Highlighted Text Colour Legend: Red Text: Red text generally indications are that there is remedial work and/or further invasive investigation required. Red text indicates that there is / could be significant damage. Red text content generally has images and further details on a separate page as detailed. Blue Text: Blue text generally indicates that there is maintenace and/or preventative maintenance required. Blue text is generally a Low to Medium Priority. Green Text: Green text is used to bring to your attention details or attributes of the property which significantly increase the weather-tightness or durability of a property. Terms Legend: Good condition: The item is in a condition expected for the age and style of the property Generally good: The item is good overall condition, there could be isolated areas with excessive wear and tear. Average condition: The item described is in standard below that expected for the age and style of the property. The item describes is in a functional condition Poor condition: The condition of the item described is below an acceptable standard. There is damage or excessive wear which requires remedial work or replacement Further invasive investigation: There will areas which will be assumed as having moisture ingress and/or damage which will require further invasive investigation identify if there is significant damage and/or the source of moisture ingress and/or what remedial work is required. SPPI recommend that the invasive investigation is initially done by removing gib board when possible. Gib board is generally easier and cheaper to replace than the exterior cladding. Removing gib board also does not further compromise the exteriors weather-tightness. Remedial Work: Remedial Work is the work required when the property has issues which need to be repaired so that the structural integrity and weather-tightness of the property is to an acceptable standard. Preventative Maintenance: Preventative maintenance are recommendations to address high risk areas which with property. Preventative maintenance are to increase the overall weather-tightness of a property. Page 21 of 22

22 Terms and Conditions: Pricing: As per the Prices and Services page at Booking Inspections: Booking by our online booking facility. Payment: Payment by credit or debit card in our online secure payment facility. Scope of Inspection: SPPI inspections are carried out under the guidelines of the NZS4306:2005. The inspection is a visual non-invasive inspection of the property with the intention of inspecting and reporting on Significant Defects Particular Attributes Gradual Deterioration Significant Maintenance Required Limitations and Liabilities: Our inspections are intended to give the highest standard of assessment of the condition of the property and are carried out under NZS4306:2005 guidelines. With out destructive testing it is not possible to be 100% certain that significant defects have been discovered. Our inspection is confined to the limitations specified by NZS4306:2005 for residential property inspections. Due to these factors it is not possible for us to guarantee that all potential defects have been discovered. Not withstanding anything in this or any other agreement with Specialist Pre-Purchase Inspections, the liability of Specialist Pre-Purchase Inspections, the person carrying out the inspection, and all of Specialist Pre-Purchase Inspections employees, contractors, directors and shareholders ( the protected parties ), for any loss, damage or delay arising from any act, default or omission (whether negligent or otherwise) in relation to the inspection, the report, or any service provided by, or statement made by, or act of, any of the protected parties ( the defects ) is restricted to any bad faith defects; is excluded in the case of all other defects made in good faith, including mistakes, mis-descriptions and omissions whether made negligently or recklessly, and whether they occurred during the course of the inspection, were made verbally, in the written report, or otherwise howsoever; shall be limited to physical damage or injury to any person or property which in any case is the foreseeable result of the defect. Shall be excluded in the case of economic and consequential loss (including loss of rent or enjoyment of the property) In any event is limited to the fee paid to Specialist Pre-Purchase Inspections. The above limitations are sever-able with the intention that if any one of them is unenforceable then the other limitations is still enforceable. This limitation of liability binds the person who requested the report and any other person to who the report is provided to, together with their successors and assigns. The report generated by Specialist Pre-Purchase Inspections is not to be relied upon by any person other than the person to whom the report is addressed to. Page 22 of 22

PRE-PURCHASE INSPECTION REPORT

PRE-PURCHASE INSPECTION REPORT PRE-PURCHASE INSPECTION REPORT PREPARED FOR: PROPERTY ADDRESS: Waiheke Island DATE: 21 November 2012 Page 1 of 13 (a) This is a report of a visual only, non-invasive inspection of the areas of the building

More information

Date of inspection 10/04/2014. Auckland Pre purchase - Condition report. Agent Present: Buyer Present: Weather at time of Inspection

Date of inspection 10/04/2014. Auckland Pre purchase - Condition report. Agent Present: Buyer Present: Weather at time of Inspection House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile: 0274 522 159 Work: 09 5334521 www.fchi.co.nz NZS 4306-2005 Full Indemnity Insurance Date of inspection

More information

Leaky Homes Financial Assistance Package (FAP) Repair plan example

Leaky Homes Financial Assistance Package (FAP) Repair plan example LEAKY HOMES FINANCIAL ASSISTANCE PACKAGE FACT SHEET Repair Plan Example - June 2014 Page 1 Leaky Homes Financial Assistance Package (FAP) Repair plan example Introduction This repair plan example is intended

More information

Residential Inspection Guidelines

Residential Inspection Guidelines Residential Inspection Guidelines 201 Pre-Pour Foundation Dimensions Building Location Certificate - if required in the building consent Construction and Advice Notes Check the building dimensions against

More information

PROPERTY INSPECTION REPORT

PROPERTY INSPECTION REPORT (850) 297-1998 1716 Monticello Dr Tallahassee, Florida 32303 PROPERTY INSPECTION REPORT THIS INSPECTION IS A DETAILED LISTING OF AREAS VISUALLY INSPECTED AT:, Tallahassee FL Client Tallahassee, FL 32304

More information

Internal Dry Area Finishes for Major Defects & Significant Items

Internal Dry Area Finishes for Major Defects & Significant Items THIS IS THE BODY OF A STANDARD TYPE REPORT WHICH HIGHLITES THE DEFECTS THERE IS ALSO A MAINTENANCE & RECOMMENDATION PROGRAMME WHICH IS NOT SHOWN FOR SECURITY REASONS s & Significant Items Note: in accord

More information

Melbourne balcony Assessments

Melbourne balcony Assessments Balcony Assessment Melbourne balcony Assessments Address: SAMPLE Date: Assessor: Luke O Neill Registered Builder DBL-C 31305 Assessment Guidelines This is an assessment of balcony and elements as presented

More information

PLEASE REFER TO YOUR INDIVIDUAL QUOTE

PLEASE REFER TO YOUR INDIVIDUAL QUOTE STANDARD INCLUSIONS AND EXCLUSIONS SECONDARY DWELLING 16/04/2014 PLEASE REFER TO YOUR INDIVIDUAL QUOTE Inclusions Super Structure: Timber Frames including Roof Trussing and Framing, Internal and External

More information

How to report a repair

How to report a repair How to report a repair for repairs to your home? We are committed to making sure your home is in a good state of repair. To meet our legal responsibilities we will: Keep the exterior (eg roof, walls, doors,

More information

Vision Home Inspection

Vision Home Inspection Vision Home Inspection 324 Rams Run Shepherdsville KY 40165-7877 Inspector: James McFadden Property Inspection Report Client(s): Property address: Inspection date: View report summary This report is the

More information

INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas

INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas 5006 Cherry Ridge Road Richmond, Texas 77406 281-342-9944 harris31@sbcglobal.net INSPECTION PROPERTY ADDRESS: INSPECTION PERFORMED FOR: XXXX Drive Fort Bend County, Texas Mr. and Mrs. New Construction

More information

The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri

The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri Determination 2009/103 The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri 1. The matters to be determined 1.1 This is a determination under Part 3 Subpart 1 of the

More information

HomeSpec REPORT SUMMARY

HomeSpec REPORT SUMMARY HomeSpec 04/25/2007 Ms. Rachel Trujeque Re: 13038 West Plum Road Lot #1225 - Peoria, AZ. 85383 - Pre Drywall Inspection Dear Ms. Trujeque, At your request, a visual pre drywall inspection of the above

More information

Bituminous Sheet Flat Roofs: Their repair and maintenance

Bituminous Sheet Flat Roofs: Their repair and maintenance Bituminous Sheet Flat Roofs: Their repair and maintenance Flat roof covered in sheets of bituminous felt Introduction Whilst flat roofs are often regarded as inferior to their pitched counterparts and

More information

COMPREHENSIVE PROPERTY INSPECTIONS

COMPREHENSIVE PROPERTY INSPECTIONS COMPREHENSIVE PROPERTY INSPECTIONS Thank you for selecting CPI for your Deficiency Observation. A full home inspection was not performed on this property at the buyers request. This inspection is a limited

More information

Total Home Inspection Checklist

Total Home Inspection Checklist Total Home Inspection Checklist Use a checklist like this to make sure that you are looking at all parts of the house. Check off those items that are in good condition and make notes about those that are

More information

Pre-Drywall Inspection Report

Pre-Drywall Inspection Report SM MEDALLION INSPECTIONS helping people make informed decisions Pre-Drywall Inspection Report 5657 Garden Valley Place Milton, Georgia 30024 Prepared for Betsy and Paul Dougherty January12, 2015 Medallion

More information

Self-Home Inspection Checklist

Self-Home Inspection Checklist To be used as a first home visit for note taking. Visit www.homeinspectiondirect.com for more tips and information about buying a home and hiring a home inspector. This form in no way replaces a professional

More information

Building Report. John Citizen. 1 Example Street Melbourne. Report Commissioned By: Property Address:

Building Report. John Citizen. 1 Example Street Melbourne. Report Commissioned By: Property Address: Phone: 0413 109 204 Fax: 9786 6492 PO Box 2414 Seaford BC 3198 nigel@completepropertyinspections.com.au Building Report Report Commissioned By: John Citizen Property Address: 1 Example Street Melbourne

More information

Repair Responsibilities A Guide for Sadeh Lok Residents

Repair Responsibilities A Guide for Sadeh Lok Residents Repair Responsibilities A Guide for Sadeh Lok Residents Sadeh Lok is responsible for most of the repairs that may arise in and around your home, but not all. Each repair type is given a likely priority

More information

C, D Only if fitted by Sadeh Lok. A, B, C Category dependent upon impact on residents enjoyment of their home

C, D Only if fitted by Sadeh Lok. A, B, C Category dependent upon impact on residents enjoyment of their home Repair Responsibilities A Guide for Sadeh Lok Residents Sadeh Lok is responsible for most of the repairs that may arise in and around your home, but not all. Each repair type is given a likely priority

More information

A.C.E. Home Inspection Service www.acehomeweb.com St. Peters, MO 63376 (636) 978-9111

A.C.E. Home Inspection Service www.acehomeweb.com St. Peters, MO 63376 (636) 978-9111 A.C.E. Home Inspection Service www.acehomeweb.com St. Peters, MO 63376 (636) 978-9111 Inspector Name: Tim Knight, ASHI Member 202490 Inspection No: 12121212 Inspection Date: 1/1/2012 Client: Address: John

More information

Home Inspection Report

Home Inspection Report Report# 21009 Page 1 of 24 Home Inspection Report Property Address: 123 Maple Lane, St. Augustine, FL 32092 Prepared For: Mr. Smith Prepared By: EDGE Inspections www.edgeinspections.com PO Box 601055 Jacksonville,

More information

Building Condition Assessment Report

Building Condition Assessment Report C2 - Nurses Resident (aka Administration) Building Condition Assessment Report Asset Address Address Construction Year Size (Gross Floor Area) Asset Type Floors Above Ground Inspection Date C2 - Nurses

More information

DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES

DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES WBCA 403 DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES A guide to assist those intending to install or who are involved in installing conservatories. Includes information about: conservatory and component

More information

(02) 6766 1477 266 Peel Street TAMWORTH www.singlebuilders.com.au. STANDARD INCLUSIONS (Residential)

(02) 6766 1477 266 Peel Street TAMWORTH www.singlebuilders.com.au. STANDARD INCLUSIONS (Residential) (02) 6766 1477 266 Peel Street TAMWORTH www.singlebuilders.com.au STANDARD INCLUSIONS (Residential) INCLUSIONS PRE-CONSTRUCTION ~ SITE WORKS ~ FOUNDATIONS Plans: Preparation of building plans and specifications

More information

BUILDING INSPECTION REPORT for: SAMPLE BUILDING INSPECTION REPORT. Inspected Property: 90 Wentworth Street, SAMPLETON

BUILDING INSPECTION REPORT for: SAMPLE BUILDING INSPECTION REPORT. Inspected Property: 90 Wentworth Street, SAMPLETON BUILDING INSPECTION REPORT for: SAMPLE BUILDING INSPECTION REPORT Inspected Property: 90 Wentworth Street, SAMPLETON Reference Number: Sample Building Inspection Report Notable Items - Summary Items observed

More information

Building Inspections Melbourne PH: 042-222-8716 support@buildinginspectionmelbourne.com.au

Building Inspections Melbourne PH: 042-222-8716 support@buildinginspectionmelbourne.com.au Building Inspections Melbourne PH: 042-222-8716 support@buildinginspectionmelbourne.com.au Report: 0003545 Pre Purchase Building & Timber Pest Inspection Report (Address removed for privacy) Prepared for:

More information

KEEP ASBESTOS YOUR QUICK GUIDE DON T BE AN EASY TARGET THIS GUIDE

KEEP ASBESTOS YOUR QUICK GUIDE DON T BE AN EASY TARGET THIS GUIDE KEEP THIS GUIDE ASBESTOS YOUR QUICK GUIDE DON T BE AN EASY TARGET Asbestos could be in the house or building you are working on right now. Left alone, it isn t dangerous. However, once disturbed, tiny

More information

www.citiesinspection.com October 5, 2015 Dear Client,

www.citiesinspection.com October 5, 2015 Dear Client, www.citiesinspection.com October 5, 2015 Dear Client, On 9/14/2015, Cities Inspection Service, Inc. completed a building inspection of the property located at 123 Oak Street, Someplace, Minnesota for you.

More information

Inspection Item COMMENTS

Inspection Item COMMENTS APPENDIX 9 AFFORDABLE HOUSING PROGRAM INSPECTION CHECKLIST Participating Jurisdiction: Homeowner Name: Assisted Property Address: Date of Physical Inspection of Property: Total Square Footage of Property:

More information

Inspection Agreement

Inspection Agreement K A R E N L O G A N Building Inspector Builder Carpenter & Joiner QBSA Lic. 79725 Pool Safety Inspector PSC Lic. 100579 Inspection Agreement Email: karentlogan@bigpond.com www.buildinginspectionreports.com

More information

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES ADDRESS: 123 MAIN ST MIAMI, FL CLIENT: BUYER ID No: 2014193 DATE: 5/13/2014 INSPECTION OR ASSESSMENT BY: GAIA CONSTRUCTION INC. CGC 1516136 FLORIDA HI-2792

More information

Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: 5. 1. Purpose

Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: 5. 1. Purpose Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: 5 1. Purpose The purpose of this practice note is to address the incidence of deck and roof membrane

More information

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C. CLIENT Inspection Report 271 Front St. Alert Bay, B.C. Island Building Inspections 2013 V ANCOUVER I SLAND B. C. Elevation Photos For the Property at 271 Front Street Alert Bay, BC ELEVATION PICTURES Front

More information

Inspection Report. Dream Home Inspections. www.timinspects.com. 415 Second Ave. Frisco CO 80443-1789 (970) 368-2668

Inspection Report. Dream Home Inspections. www.timinspects.com. 415 Second Ave. Frisco CO 80443-1789 (970) 368-2668 Inspection Report Property Address: 123 Dream Home Way Frisco, CO 80443 Prepared for: Inspector: Tim Nixon Tim Nixon Inspection date: 3/28/2014 1 of 9 General Information Property Information Address:

More information

HEDDERMAN ENGINEERING, INC. www.heddermanengineering.com Office 281-355-9911, Fax 281-355-9903 office@heddermanengineering.com

HEDDERMAN ENGINEERING, INC. www.heddermanengineering.com Office 281-355-9911, Fax 281-355-9903 office@heddermanengineering.com HEDDERMAN ENGINEERING, INC. www.heddermanengineering.com Office 281-355-9911, Fax 281-355-9903 office@heddermanengineering.com, 2011 TO: Mr. REF: CONDITION OF PROPERTY SURVEY Dear Mr. : At your request,

More information

Report for. Dick and Jane Homeowner. 1234 Lovers Lane, Houston, Texas 77000

Report for. Dick and Jane Homeowner. 1234 Lovers Lane, Houston, Texas 77000 Report for Dick and Jane Homeowner 1234 Lovers Lane, Houston, Texas 77000 March 17, 2004 I NI NP R Inspection Item I. STRUCTURAL SYSTEMS o o o A. Foundations (If all crawl space areas are not inspected,

More information

Structure Survey Findings:

Structure Survey Findings: Structure Survey Findings: Visible portions of the following were observed: foundations; structure to walls, columns, floors, roofs, overhang posts, and columns; attached or firmly abutting decks, balconies,

More information

Defining who is responsible for items and areas in a Strata Scheme

Defining who is responsible for items and areas in a Strata Scheme www.lpi.nsw.gov.au No: 2011/07 Date: October 2011 Defining who is responsible for items and areas in a Strata Scheme Land and Property Information, a division of the Department of Finance and Services

More information

Inspecting to a higher standard.

Inspecting to a higher standard. Inspecting to a higher standard. Rob Hopkin Silver Spring, MD 20902 Monday, June 2, 2014 ProTec Inspection Services Inc. 19736 Selby Ave Poolesville, MD 20837 301-972-8531 www.protec-inspections.com rob@protec-inspections.com

More information

Exterior Elevated Elements Inspection Guidelines

Exterior Elevated Elements Inspection Guidelines Exterior Elevated Elements Inspection Guidelines Planning and Development 1. Guideline Purpose These guidelines are intended to assist practicing professionals in complying with Berkeley Municipal Code

More information

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207 BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207 SELF EVALUATION CHECKLIST FOR RESIDENTIAL AND MULTI-FAMILY DWELLING INSPECTIONS The attached checklist

More information

Building Condition Assessment Report

Building Condition Assessment Report Building Condition Assessment Report Asset C3c - Oak Terrace Cottage 121 Address Riverview Lands, 2601 Lougheed Highway, Coquitlam, BC. V5C 4J2 Construction Year Size (Gross Floor Area) 1920. 2,553 Sq.Ft.

More information

Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10

Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10 Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10 PROPERTY DESCRIPTION PROPERTY INSPECTED: INSPECTION ADDRESS: 4722 Baltimore Avenue

More information

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: 1860. Inspection Date: Saturday, February XX, XXXX

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: 1860. Inspection Date: Saturday, February XX, XXXX SUMMARY REPORT Report Number: 1860 Inspection Date: Saturday, February XX, XXXX Property Address: XX XXXXX XXX Toronto, ON XXX XZX Client Name: Xxxx Xxxxxxxxxxxxx Prepared by: Andrew Marioselva BSc,CHI

More information

Cost Guide MARKET SUMMARY OVERVIEW REPAIRS AND MAINTENANCE ELECTRICAL ROOFING & ROOF DRAINAGE (UP TO TWO STOREYS; FIXED TO EXISTING ROOF FRAME)

Cost Guide MARKET SUMMARY OVERVIEW REPAIRS AND MAINTENANCE ELECTRICAL ROOFING & ROOF DRAINAGE (UP TO TWO STOREYS; FIXED TO EXISTING ROOF FRAME) Cost Guide < 1 > MARKET SUMMARY OVERVIEW Low interest rates and competitive construction pricing makes now a great time to renovate or build a new home. Interest rates are at historic lows and can be fixed

More information

Pest & Building Report

Pest & Building Report ACN 166 451 476 M.B.A member No 1853699 Builders Lic No 199149C SYDNEY: EMAIL: CANBERRA: EMAIL: MELBOURNE: EMAIL: 1300 552 262 P.O Box 38. GLENFIELD NSW 2167 info@restwell.com.au 1300 552 262 P.O Box 4839,

More information

MULTI-FAMILY, COMMERCIAL, INDUSTRIAL, AS GOVERNED BY THE BC BUILDING CODE PART 3

MULTI-FAMILY, COMMERCIAL, INDUSTRIAL, AS GOVERNED BY THE BC BUILDING CODE PART 3 TOWN OF SIDNEY Multi-Family, Commercial, Industrial and Institutional Building Permit Guide The information provided is intended as a guide only and does not replace current bylaws and regulations. Complete

More information

RRIO Checklist. Use of checklist: Definitions: Limitations

RRIO Checklist. Use of checklist: Definitions: Limitations CITY OF SEATTLE RENTAL REGISTRATION AND INSPECTION ORDINANCE (RRIO) RRIO Checklist Use of checklist: Property owners will use the RRIO Checklist to confirm that their rental housing properties and units

More information

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances. Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org

More information

N.S.W. MASTER BUILDING INSPECTORS

N.S.W. MASTER BUILDING INSPECTORS Members Master Builders Association N.S.W. MASTER BUILDING INSPECTORS ABN 89 098 140 197 www.buildinginspectors.com.au Level 5, 203 New South Head Road, Edgecliff, NSW, 2027 Phone: 9369 2787, Fax: 9388

More information

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

NRG 75 CRF NRG GREENBOARD WALL SYSTEM NRG GREENBOARD WALL SYSTEM NRG Energy Efficient Building Systems is pleased to announce a revolution in lightweight cladding systems. NRG Building Systems is the first and only company to achieve CodeMark

More information

Scope of works. Name Job# TBA -1. Project: Bathroom Renovation

Scope of works. Name Job# TBA -1. Project: Bathroom Renovation Scope of works Name Job# TBA -1 Address Date Suburb P. code Phone H BH 0 Mobile E-mail Project: Bathroom Renovation.01 Demolition Strip out and remove from site: All existing fixtures, fittings and cabinets

More information

SUGGESTED CONSTRUCTION SEQUENCE - Owner Builders

SUGGESTED CONSTRUCTION SEQUENCE - Owner Builders SUGGESTED CONSTRUCTION SEQUENCE - Owner Builders ARRANGE SERVICES Arrange with your electrician a temporary supply of electricity. Also organise with your plumber a water supply for the duration of the

More information

FLASHMAN WINDOW AND DOOR FLASHING SYSTEM. Product. Scope. Appraisal No. 573 [2013]

FLASHMAN WINDOW AND DOOR FLASHING SYSTEM. Product. Scope. Appraisal No. 573 [2013] FLASHMAN WINDOW AND DOOR FLASHING SYSTEM This Appraisal replaces BRANZ Appraisal No. 573 (2007). Amended 05 February 2016. BRANZ Appraisals Technical Assessments of products for building and construction.

More information

WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME

WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME 1 THE BUILDING PROCESS The focus of Woodland Homes building department is Quality, Service and Predictability. Through

More information

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES ADDRESS: Somewhere, FL CLIENT: GAIA GC ID No: 2015000 DATE: 12/31/2015 INSPECTION OR ASSESSMENT BY: GAIA CONSTRUCTION INC. CGC 1516136 FLORIDA HI-2792 FLORIDA

More information

Jagger Enterprises, Inc. dba Buckeye Home Inspections 17204 Dorchester Drive Cleveland OH 44119-1302 (216) 486-4663 Fax (216) 486-9922

Jagger Enterprises, Inc. dba Buckeye Home Inspections 17204 Dorchester Drive Cleveland OH 44119-1302 (216) 486-4663 Fax (216) 486-9922 Jagger Enterprises, Inc. dba Buckeye Home Inspections 17204 Dorchester Drive Cleveland OH 44119-1302 (216) 486-4663 Fax (216) 486-9922 November 09, 2002 Name deleted, Esq. address deleted Your client:

More information

Residential Pre-purchase Inspection Report

Residential Pre-purchase Inspection Report PO Box 540 Coburg VIC 3058 Phone: (03) 9333 8814 Fax: (03) 9308 3341 Mobile: 0414 184 686 E-mail: info@melbournepropertyinspections.com.au ABN: 38129747815 Date of inspection: Residential Pre-purchase

More information

Condition Report SAMPLE. Property address. Client s name. Date of inspection

Condition Report SAMPLE. Property address. Client s name. Date of inspection Client s name Date of inspection Contents 1 A B C D E F G H I J K Introduction to the report About the inspection Summary of the condition ratings About the property Outside the property Inside the property

More information

Inspecton Report. Property Address:

Inspecton Report. Property Address: Inspecton Report Provided by: National Home Inspections Inspector: Bob Smith 456 S Main Denver, CO 46312 (645) 423-3242 bob@nationalhomeinspections.com www.nationalhomeservices.com Property Address: 873

More information

SCHEDULE OF FINISHES AMBLE RIDGE RETIREMENT VILLAGE

SCHEDULE OF FINISHES AMBLE RIDGE RETIREMENT VILLAGE SCHEDULE OF FINISHES AMBLE RIDGE RETIREMENT VILLAGE SITEWORKS FOUNDATIONS & SURFACE BED Site to be cleared and leveled. Builder s rubble to be carted away. As per Engineer s design, with USB green waterproofing.

More information

#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check

#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check #1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check Zoning laws Deed restrictions on home size, foundation style, roof pitch, etc. Suitability (slope, wetland issues, etc.) Accessibility

More information

Burns Home Services SUMMARY REPORT. 7/18/2006 Start: 9:00 am End: 12:30 pm

Burns Home Services SUMMARY REPORT. 7/18/2006 Start: 9:00 am End: 12:30 pm Burns Home Services Service Makes the Difference 2620 W Grovers Ave, Phoenix, AZ 85053 Tel: 602-889-6970 Fax: 602-870-4563 Mobile: 602-291-7138 Garryh@burnshomeservices.com SUMMARY REPORT Client: John

More information

PROPERTY INSPECTION REPORT

PROPERTY INSPECTION REPORT South Coast Home Check Building Consultants. Pre Purchase Building & Pest Reporting - Viability & Condition Reporting - Asset Management. Master Builders Member: 1845299 - HIA Member: 391315. Accredited

More information

Issue of the Guidelines on Prevention of Water Seepage in New Buildings

Issue of the Guidelines on Prevention of Water Seepage in New Buildings graphic: Buildings Department Your REF 來 函 檔 號 :. OUR REF 本 處 檔 號 :.BD GR/1-55/173 FAX 圖 文 傳 真 :..28400451 TEL 電 話 :..2626 1717 www.info.gov.hk/bd To : All Authorized Persons 7 March 2005 Registered Structural

More information

Does Wall Township require an inspection by the building department on resale of a home?

Does Wall Township require an inspection by the building department on resale of a home? Selling your home Does Wall Township require an inspection by the building department on resale of a home? No. We do not require a Certificate of Continued Occupancy on the resale of home. A Smoke Detector,

More information

Plumbing Identification and Damage Assessment Guide

Plumbing Identification and Damage Assessment Guide Plumbing Identification and Damage Assessment Guide *Please note that not all systems will be represented exactly by these diagrams and photos. As a vendor, it is required that you familiar yourself with

More information

Foundation Evaluation Report for PROPERTY ADDRESS Houston, Texas 77089. August 30, 2012. Prepared for:

Foundation Evaluation Report for PROPERTY ADDRESS Houston, Texas 77089. August 30, 2012. Prepared for: A Full Service Real Estate Inspection & Engineering Firm for Houston, Texas 77089 August 30, 2012 Prepared for: CLIENT S NAME MAILING ADDRESS Houston, Texas 77089 Prepared by: Charles J. Jenkins, P.E.

More information

StuccoSpec Moisture Testing Inspection

StuccoSpec Moisture Testing Inspection e-mail - stuccospec@juno.com StuccoSpec Moisture Testing Inspection Property Located At: 265 Elm Street, Anywhere, USA 01/27/02 Ordered by: Mr. & Mrs. John Doe #2 Song Sparrow Place, The Woodlands, T 77381281-364-0012

More information

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION # BLOCK LOT VACANT YES NO CURRENT OWNER NAME ADDRESS TELEPHONE # PROSPECTIVE

More information

Rehab Inspection Report Page 1

Rehab Inspection Report Page 1 Rehab Inspection Report Page 1 Home Address: Construction Style: Number of bedrooms Square footage: Value of offer: Estimated rehab cost: Value of resale: Orientation of house: N S E W Note: orientation

More information

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES Building and Construction Industry A joint industry initiative produced by BSA Supershow logo.indd 1 30/01/2008 9:43:29 AM EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES FAILING WATERPROOFING

More information

EAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST

EAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST DATE TIME EAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST INSPECTOR: LICENSE # ADDRESS: PROPERTY OWNER: SINGLE: DOUBLE: MULTI-UNIT # OF UNITS POINT OF INSPECTION Sanitation IPMC 302.1

More information

House Inspection Report

House Inspection Report 021 786246 House Inspection Report 123 Somewhere St. Page 1 of 27 Summary Landscaping and Gardens 1. Driveway: Concrete - Heavy cracks in surface 2. Gates: Unpainted timber - Some rot noted 3. Garden Sheds:

More information

Stucco Moisture Inspection Report

Stucco Moisture Inspection Report Stucco Moisture Inspection Report For the Property Located At: Sample Inspection St. Report Prepared Ecusively For: Potential Buyer Pace FL. 32571 >< 850.393.6106 >< ofc- 850-941-8600 > Email: pat@moistureconsultantsinc.com

More information

I NI NP R Inspected Items

I NI NP R Inspected Items 6/ /07 The Inspection of the property listed above must be performed in compliance with the rules of TREC. The inspection is of conditions which are present and visible at the time of the inspection, and

More information

Exterior Condition Report

Exterior Condition Report Scope of Work for Property Located at: 3918-20 West Cherry Street Date: 3/10/2014 Property is: Single Family Duplex Below is the minimum requirement to meet health and safety issues. The City of Milwaukee,

More information

Timber Pest Inspection Agreement. Ph: Fax: Mobile: E-mail: Purchaser: Vendor (If Known): Re Property to be Inspection at:

Timber Pest Inspection Agreement. Ph: Fax: Mobile: E-mail: Purchaser: Vendor (If Known): Re Property to be Inspection at: Timber Pest Inspection Agreement Client: Address: State: Post Code: Ph: Fax: Mobile: E-mail: Purchaser: Vendor (If Known): Re Property to be Inspection at: State: Post Code: Date of Proposed Inspection

More information

A home owner s guide to rebuilding after a flood

A home owner s guide to rebuilding after a flood A home owner s guide to rebuilding after a flood March 2015 Steps to repair a house after a flood Below are the recommended steps to repair and restore houses after a flood event: ensure initial safety

More information

Home Inspection Report

Home Inspection Report 4949 Brownsboro Rd Suite 293 Louisville, KY 40223 (502) 414-1440 tripleainspections@gmail.com Inspected By: William Carter, HI-1956 Home Inspection Report Prepared For: Edward Cullen Property Address:

More information

Inspection Report. Prepared For: Sampath Sample. Property Address: 12712 Waterside Drive. Alpharetta, GA 30004. Atlanta Home Inspections

Inspection Report. Prepared For: Sampath Sample. Property Address: 12712 Waterside Drive. Alpharetta, GA 30004. Atlanta Home Inspections Page 1 of 37 Inspection Report Prepared For: Sampath Sample Property Address: Alpharetta, GA 30004 Atlanta Home Inspections Matthew A Thoroman 6625 Hwy. 53 E. Ste. 410-151 Dawsonville Ga 30534 (678)-410-8062

More information

U.S. Department of Housing and Urban Development Office of Public and Indian Housing. A Good Place to Live!

U.S. Department of Housing and Urban Development Office of Public and Indian Housing. A Good Place to Live! U.S. Department of Housing and Urban Development Office of Public and Indian Housing A Good Place to Live! Introduction Having a good place to live is important. Through your Public Housing Agency (or

More information

L&Q new home warranty L&Q new. home warranty

L&Q new home warranty L&Q new. home warranty L&Q new home warranty L&Q new Peace of mind in your new home home warranty Peace of mind in your new home Running in your new home You may not be aware that new homes have a running in period. One of the

More information

Water Damage & Repair

Water Damage & Repair Water Damage & Repair Chinatown Preservation Talks 2015 James Engler, P.A Glenn Mason, AIA Mason Architects Program Outline Terminology & Waterproofing Basics Discussion of why this is important Below

More information

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector Plumbing Helpful Hints Residential Construction Bert Polk Plumbing Inspector Lincoln County 2015 Waste and vent fittings Vent 90 medium 90 long 90 1/16 bend,1/8 bend,1/6 bend, medium 90 san tee combination

More information

TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09

TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09 TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09 PMT GUIDE # 10 Book of Order Section G-10.0102o: "The session is responsible for the mission and government of the particular church. It

More information

COST OF WORK FORM. Abbreviations: ea = each, LF = linear feet, SF = square feet, HSF = square feet of living area (including garage conversion space)

COST OF WORK FORM. Abbreviations: ea = each, LF = linear feet, SF = square feet, HSF = square feet of living area (including garage conversion space) COST OF WORK FORM All costs shown are estimates using base grade materials, taxes, and labor. For houses where a higher quality is indicated, the costs should be increased for work requiring upgraded materials.

More information

MAC-ENC-PRG-004 EDINGLASSIE AND ROUS LENCH HERITAGE MANAGEMENT PROGRAM

MAC-ENC-PRG-004 EDINGLASSIE AND ROUS LENCH HERITAGE MANAGEMENT PROGRAM EDINGLASSIE AND ROUS LENCH HERITAGE MANAGEMENT PROGRAM Document Owner Luke Stevens, Document Approver Rob Hayes, Environment and Community Manager Version Date Details No. Published 1.0 15/08/12 Draft

More information

PETERSONS WATERFRONT CONDOMINIUMS

PETERSONS WATERFRONT CONDOMINIUMS CONSULT DESIGN CONSTRUCT PETERSONS WATERFRONT CONDOMINIUMS 103 Park Street Chelan, Washington Findings Summary Report Prepared for: Petersons Waterfront Condominium Association March 21, 2014 J2 Project

More information

RESPONSIBILITY FOR REPAIRS AND MAINTENANCE FAIR FUNDING: April 2002

RESPONSIBILITY FOR REPAIRS AND MAINTENANCE FAIR FUNDING: April 2002 RESPONSIBILITY FOR REPAIRS AND MAINTENANCE FAIR FUNDING: April 2002 INDEX New Build Flat and Pitched Roofs Rainwater Goods Porches to Existing Buildings / Covered Links etc, Between Buildings Floors /

More information

CHRIS CURLES and ASSOCIATES INSPECTION SERVICES

CHRIS CURLES and ASSOCIATES INSPECTION SERVICES CHRIS CURLES and ASSOCIATES INSPECTION SERVICES Inc. Chris Curles, President www.homeinspectionsatlanta.com chriscurl@comcast.net Office: 770-493-0227 Professional Member Of: GAHI # 93006 ASHI # 211725

More information

How To Prevent Water Damage To A Home

How To Prevent Water Damage To A Home Having inspected about 800 homes in the last four years, I have seen a lot of problems with many homes. Most of these problems are minor; however, there are some problems that are quite serious. One of

More information

PROPOSAL. Prepared for: Craig Mottram & Family, 118 Rangoon Rd. Prepared by: Carlos Andrade, Owner & Operator. Brandon Andrade, Project Coordinator

PROPOSAL. Prepared for: Craig Mottram & Family, 118 Rangoon Rd. Prepared by: Carlos Andrade, Owner & Operator. Brandon Andrade, Project Coordinator PROPOSAL Prepared for: Craig Mottram & Family, 118 Rangoon Rd. Prepared by: Carlos Andrade, Owner & Operator Brandon Andrade, Project Coordinator t. 416.652.6424 f. 416.652.3234 May 1 st, 2012 Craig Mottram

More information

Home Warranty Inspection Report

Home Warranty Inspection Report Scope of the Inspection 1111 Sample Dr. home warranty inspection 2/30/2006 Home Warranty Inspection Report 1111 Sample Dr., Detroit, MI 48223 Inspection Date: February 30, 2006 Client: Alfred E. Neumann

More information

G. Common Defects in Buildings - Leakage

G. Common Defects in Buildings - Leakage F. Common Defects in Buildings - Structural 32. Recently, some concrete chips have fallen from the ceiling in my kitchen. There are rusty steel bars and the area in question measures about 300 x 400mm.

More information

Home Inspection Report

Home Inspection Report Home Inspection Report 555 Wind Way, Fake City, OR 54645 Inspection Date: Monday May 12, 2014 Prepared For: John Doe Prepared By: House to Home 3468 N. Bartlett Ave Milwaukee, WI 53211 262-754-5973 christopher@ahit.com

More information

ELIGIBLE REPAIR PROJECT PARAMETERS

ELIGIBLE REPAIR PROJECT PARAMETERS THE DISTRICT MUNICIPALITY OF MUSKOKA ONTARIO RENOVATES PROGRAM FOR HOMEOWNERS ELIGIBLE REPAIR PROJECT PARAMETERS 1. To have your project considered and payment processed, all projects requiring a Building

More information