Compack c Hea e t building h eat solutions

Similar documents
Overview of Heat Recovery Boiler Systems and Operating Costs Factors Effecting Blowdown Blowdown Heat Recovery The Energy Tank

FLASH TANK ECONOMIZER PRODUCT GUIDE

Commercial Semi-Instantaneous Water Heaters

Steam System Best Practices Condensate System Piping

Defining Quality. Building Comfort. Heating and Cooling Coils

In-Line Air Separators

DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING

EJECTOR AIR REMOVAL SYSTEMS ENGINEERING DATA BULLETIN # PVS ARS PAGE 1 OF 5

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Indirect-fired Steam & Boiler Water Heaters

VAD. Variable Area Desuperheaters

API Flanged Safety Relief Valves Series 526 CATALOG

Heating Water by Direct Steam Injection

Maxi-Therm. Since 2002, throughout North America, Maxi-Therm has been manufacturing innovative packaged solutions for informed specifiers.

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

steam centre of excellence Steam Boiler System Optimization

Sample Coolers. Water Steam Process. The largest selection of models offered by any manufacturer.

Steam System Efficiency. Bill Lumsden Leidos Engineering

IGEMA BOILER LEVEL & TDS CONTROLS

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE

Vogt Valves The Connection Bulletin for Forged Steel Flow Control Valves CB 15

COMMERCIAL HVAC EQUIPMENT. Condensers and Cooling Towers

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

Condensing Economizers Workshop Enbridge Gas, Toronto. MENEX Boiler Plant Heat Recovery Technologies. Prepared by: Jozo Martinovic, M A Sc, P Eng

How To Understand Evaporator

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Commercial Gas Water Heaters

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

VACUUM REFRIGERATION SYSTEMS

MAC-120HE-01 Air-Cooled Chiller

System Solutions for Boiler Air Preheating

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

C. starting positive displacement pumps with the discharge valve closed.

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

Steam Coil Installation, Operation and Maintenance

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

How To Make A Pressure Relief Valve

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

WD600 STEAM TRAPS. Thermodynamic Steam Trap

Type 92S Pilot-Operated Steam Regulator

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

heat transfer solutions Steam to Water Heat Transfer Packages for Domestic Hot Water

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

VAD Variable Area Desuperheaters

Rusty Walker, Corporate Trainer Hill PHOENIX

PLBG/GAS SAFETY Information Bulletin

Increasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas

Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations

Contents and Nomenclature

Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"

BOILER FEED AND CONDENSATE RECOVERY SYSTEMS Extend the life and efficiency of your boiler system

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

TABLE OF CONTENT

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

Commercial Gas Water Heaters

Commercial Storage Tanks

Desuperheater Online Program Sizing Guidance

A Selection Guide for DTL Series Heat Exchangers

Blowdown vessels Meeting the requirements of HSE PM60

NICHOLSON STEAM TRAP Fax: STEAM TRAP

How To Clean Up A Reactor Water Cleanup

High School Graduation years 2013, 2014, Unit/Standard Number

Technical Data Manual Model Nos. and pricing: see Price List

DESIGNER S GUIDE STEAM TRAPS & SPECIALTIES

HS-901(A) BASIC STEAM HEATING SYSTEMS

The Unique Accelabar Flow Meter

Solenoid valves Type EVU

Radiant Panels and Chilled Sails.

Corrugated Tubular Heat Exchangers

SIOUX HYBRID WATER HEATER

G234X-55 Conventional Gas Boiler

REGULATING VALVE APPLICATIONS

PBX Series Quick Fit Connector Bimetallic Steam Traps

MUELLER FALLING FILM CHILLERS

Steam System Design and Best Practices Related to Kiln Drying

LG Electronics AE Company, Commercial Air Conditioning

Automatic Self-Cleaning Strainers

Boiler Blowdown. Boiler Blowdown Benefits. Best Operating Practices for Boiler Blowdown

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

Heat Recovery In Retail Refrigeration

Course available 24/7 for up to six months from the date of purchase or until completion

Industrial Steam System Process Control Schemes

Self-operated Temperature Regulators Type 1 to Type 9. PN 16 to 40 Class 125 to 300 DN 15 to 250 NPS ½ to 10 G ½ to 1 Up to 350 C Up to 660 F

NAVIEN AMERICA INC FITCH AVENUE

Gas Line Sizing. Z Maximum gas demand shall be determined by adding all of the equipment Btu ratings from appliances connected on the system.

Thermostatic valve Type AVTA

REGULATORS 175/153 Series

MC (Multi-Circulation) f o r S A G D a n d I n d u s t r i a l A p p l i c a t i o n s

DRAFT HOOD OUTLET GS6-30-YORT NG Select - Tall - C3 Technology 28 FIRST HOUR RATING BTU INPUT PER HOUR

High efficiency, cast-iron gas boiler

TECHNICAL SERVICE LEADERSHIP

Principals of Condensing Boiler System Design

MFP14, MFP14S and MFP14SS Automatic Pumps

THE ADVANCED DENTAL DRY VAC DENTAL SYSTEMS

Transcription:

CompackHeat building heat solutions

OUR EXPERIENCE - your guarantee Preston Phipps represents the ultimate specialist in steam and industrial products built on over 75 years of loyal customer commitment and trust. Headquartered in Montreal, Quebec, with 10 other offices located across Canada the company markets, distributes and services a broad range of industrial steam, valve, HVAC products and packaged solutions. Preston Phipps' engineering and sales staff possess extensive knowledge and expertise of the industrial systems and applications used by these industries. As such our value proposition relies on our ability to understand and exceed the expectations of our valued customers, providing flexible processes for delivering high quality products and services. COMPACKHEAT - our our solution, your added value Our product and customer focus enables us to respond quickly and efficiently to our customers most stringent requirements. We customize every solution to match the exact requirements of our customers needs. There is no challenge that we can t overcome and there is no substitute for our experience. The CompackHeat is the packaged building heat solution you are looking for. It s compact, simple, precise and provide low ownsership cost. You deal with only one vendor who takes responsibility of the whole system. CANADIAN TRADE-MARKS In 2011, after almost 10 years of providing packed solutions, Preston Phipps has registered CompackHeat with Canadian Intellectual Property Office. We stand behind this brandname and we guarantee that every packaged solution that is manufactured at our facilities ships to our customers with the highest quality that the market offers.

Is a pre-assembled compact heat exchanger package designed specifically for building heating applications. THE PRINCIPAL - FLOODED HEAT EXCHANGER FLOODED HEAT EXCHANGER GREEN APPROACH Based on a proven concept this design utilizes the sensible & latent heat of steam and eliminates the loss of energy through flash. HOW IT WORKS A conventional heat exchanger modulates the steam inlet to control the outlet water temperature. The COMPACKHEAT controls the outlet water temperature by modulating the condensate outlet and flooding the heat exchanger. In summary instead of modulating the differential temperature as a conventional design, the COMPACKHEAT SOLUTION uses the heat transfer surface by varying the condensate level according to the process demand.

key advantages simple - No steam prv - No steam srv (no steam safety relief to roof) - No pump trap - No condensate tank - No stabilizing pump - No steam inlet control valve convenient - Pre-assembled and engineered solution - Compact design requiring less footprint - System can use high, medium or low steam pressure - Two heat exchangers types available - Smaller control valve & steam trap - No high velocity steam noises - Condensate can be lifted without pump trap - Industrial design for HVAC market precise - Final temperature set point stable ±1F energy saving - No flash steam loss (200 F condensate return) - Use of latent and sensible heat of steam - Less steam consumption - Less make-up water at the boiler - Less chemical treatment and blowdown at the boiler - Reduction of greenhouse gas

versus conventional design Below is a job comparison between a CompackHeat and a conventional system. Both systems have been selected and designed for the operating conditions below. - Capacity : 2,500,000 Btu/hr - Heating 425 usgpm of water from 188 F to 200 F, F using saturated steam at 140 psig - Exchanger designed with maximum liquid pressure drop of 5 psi COMPACKHEAT Condensate outlet : 200 f Steam consumption : 2,436 lbs/hr Use of sensible & latent heat footprint : 66 x 27 Overall height : 80 Preston Phipps job # 211268 Quantity : 2, shipped in march 2013 CONVENTIONAL Condensate outlet : 361 F Steam consumption : 2,872 lbs/hr Use of sensible heat only Footprint : 113 x 53 Overall height : 118 Drawing is to scale and made for simulation only

TYPICAL DRAWINGS

specifications 1. FLOODED STEAM HEAT EXCHANGER 1.1. Pre-assembled flooded steam heat exchanger package unit shall be CompackHeat model : [CH-model], designed and manufactured by Preston Phipps Inc. The unit controls the hot liquid outlet temperature by modulating the condensate level into the heat exchanger according to the process demand. The design utilizes the sensible and latent heat of saturated steam by subcooling the condensate. Supply steam pressure to the unit shall be constant. Conventional design with modulating steam pressure supply is not accepted. 1.2. System shall be designed for heating [usgpm] usgpm of water/ethylene glycol/propylene glycol x% from [inlet temp] ºF to [outlet temp] ºF, using [condensate load] lbs/h of saturated steam at [psig] psig. Subcooling at [temp] ºF. Capacity of [Btu/h] Btu/h. 1.3. Package shall be complete with heat exchanger, condensate control valve, steam trap, check valve, strainer, necessary interconnecting piping, fittings, valves and instrumentations, and a complete hydronic package model : [PMP-model], simplex or duplex hot water recirculation pumps, mounted on a steel frame and support base. 1.4. Heat exchanger shall be a Shell & Coil type, complete 316L stainless steel welded construction, helically coiled corrugated tube bundle, angular connections and designed for a compact vertical installation. Design pressure/temperature shall be 300 psi / 422 ºF. The heat exchanger shall be designed, tested and manufactured in accordance with ASME Section VIII Div. 1, comes from an ISO 9001 manufacturing shop and be CRN registered. or Heat exchanger shall be a Plate & Shell type, fully welded carbon steel shell and 316L stainless steel plates with no gaskets, no brazed connections and designed for a compact installation. Design pressure/temperature shall be 150 psi / 400 ºF (or) 300 psi / 400 ºF. The heat exchanger shall be designed, tested and manufactured in accordance with ASME Section VIII Div. 1, comes from an ISO 9001 manufacturing shop and be CRN registered. 1.5. Control valve... Contact us to get your CompackHeat TM specifications!

capacity using shell & coil exchanger heating water from 160 F to 180 F, Subcooling to 200 F, Footprint guidance LxWxH (inches) images shown are typical configuration for reference only

capacity using shell & plate exchanger heating water from 160 F to 180 F, Subcooling to 200 F, Footprint guidance LxWxH (inches) images shown are typical configuration for reference only

data sheets

hydronic data sheets

previous realisations examples

Contact us Preston Phipps has several offices across Canada. Montreal, QC - headquarter 6400 Vanden Abeele, Saint-Laurent, QC, H4S 1R9 T : 514-333-5340 Quebec, QC Q 755 des Rocailles, Québec, QC, G2J 1A2 T : 418-628-6471 Dartmouth, NS 202 Brownlow Avenue, unit E, Building E, Dartmouth, NS, B3B 1T5 T : 902-468-2004 Moncton, NB 874 Bernard Street, Dieppe, NB, E1A 5A4 T : 506-640-1801 Newfoundland, NL 306-100 Elizabeth Avenue, St. John s, NL, A1B 1R9 T : 709-699-2711 Ottawa, ON 200 Tremblay Road, Room 204, Ottawa, ON, K1G 3H5 T : 613-244-6334 Toronto, ON 6685 Millcreek Drive, Unit 2, Mississauga, ON, L5N 5M5 T : 905-363-0104 Sarnia, ON 429 Exmouth St., Suite 202, Sarnia, ON, N7T 5P1 T : 519-344-2824 Edmonton, AB 9357, 45 th Avenue, Edmonton, AB, T6E 5Z7 T : 780-437-5199 Calgary, AB 809 Manning Road N.E., Unit 106, Calgary, AB, T2E 7M9 T : 403-273-5199 Vancouver, BC 4259 Canada Way, Suite 214, Burnaby, BC, V5G 1H1 T : 778-328-9888 Preston Phipps Inc. 6400 Vanden Abeele Saint-Laurent, Qc H4S 1R9 T : 514-333-5340 F : 514-333-6680 E : info@prestonphipps.com www.prestonphipps.com CompackHeat is a registered trademark of Preston Phipps Inc.