I-Dent Marker Communications for ARM CPU Firmware Version 3

Similar documents
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Modbus and ION Technology

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

DSA-1000 / PRT-1000 Device Server / Thermal Printer

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

Multi-Master DF1 Protocol User Guide

Modbus and ION Technology

Master-Touch and ValuMass. Modbus Communications. INSTRUCTION MANUAL (Rev. 2.1)

MATRIX 210. Host Mode Programming

ACCESS 9340 and 9360 Meter Ethernet Communications Card ETHER

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T PIN6 T PIN7 R+ PIN8 R-

Modbus Communications for PanelView Terminals

Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

How to use KEPServerEX OPC Server (Kepware) with iologik 4000 (Modbus TCP/IP NA-4010 and Modbus Serial NA-4020/NA-4021)

EMG Ethernet Modbus Gateway User Manual

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series

Using HyperTerminal with Agilent General Purpose Instruments

1 Serial RS232 to Ethernet Adapter Installation Guide

Process Control and Automation using Modbus Protocol

Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

7.7 Ethernet Communication (AFPX-COM5)

The goal is to program the PLC and HMI to count with the following behaviors:

FINS Gateway For OMRON PLCs

Using IDENT M System T with Modbus/TCP

Arduino Wifi shield And reciever. 5V adapter. Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the shield:

PM1122 INT DIGITAL INTERFACE REMOTE

Operation Manual of EX-9132C-2. Serial to TCP/IP Converter

CENTRONICS interface and Parallel Printer Port LPT

Operation Manual of EX9132C-RS485. Serial to TCP/IP Converter

EZ-View Network Communications Guide

Single channel data transceiver module WIZ2-434

MODBUS TCP to RTU/ASCII Gateway. User s Manual

RN-XV-RD2 Evaluation Board

FBs-CM25/CM55/CBE. Ethernet Module. User s Manual

The Answer to the 14 Most Frequently Asked Modbus Questions

Application/Connection Examples

SenseLink TM. End-Point Controller. Addendum

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

H0/H2/H4 -ECOM100 DHCP & HTML Configuration. H0/H2/H4--ECOM100 DHCP Disabling DHCP and Assigning a Static IP Address Using HTML Configuration

LS-101 LAN to Serial Device server. User s Manual

PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400

eztcp Technical Document Modbus/TCP of eztcp Caution: Specifications of this document may be changed without prior notice for improvement.

PLC training panel (Twido version)

MS830 / MS833 Barcode Reader v1.0 9-December-2014

Operating Instruction MEW01652 Revision -

IP Link Device Interface Communication Sheet

WIZnet S2E (Serial-to-Ethernet) Device s Configuration Tool Programming Guide

Introduction: Implementation of the MVI56-MCM module for modbus communications:

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

Modbus Protocol. PDF format version of the MODBUS Protocol. The original was found at:

Silver Series EM Operator Interface Terminals. Addendum to EZwarePlus Programming Manual

SDN INSTRUCTIONS 07/10, Ver 1.2. Somfy Digital Network (SDN) Installation and Programming

1.1 Connection Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking

Installation & Configuration Manuel. Socket Server. OpenAT application

Follow these steps to prepare the module and evaluation board for testing.

How To Set Up A Modbus Cda On A Pc Or Maca (Powerline) With A Powerline (Powergen) And A Powergen (Powerbee) (Powernet) (Operating System) (Control Microsci

Serial Over IP Ethernet Device Server

IntesisBox KNX Modbus TCP master

Configuring IP to Serial with Auto Answer and Serial to IP

How to use Citect (SCADA) with iologik 4000 (Modbus TCP/IP NA-4010 and Modbus Serial NA-4020/NA-4021)

isco Connecting Routers Back to Back Through the AUX P

Application & Quick-Start Guide

Bluetooth UART/RS232 Module

USR-TCP232-T Hard Version: V2.0 Doc Version: V

Schneider OS-Loader usage via Ethernet or USB.

EZ-ZONE RMA & EtherNet/IP Configuration & Startup Using an Allen-Bradley CompactLogix PLC EtherNet/IP Fundamentals

NVT (Network Virtual Terminal) description

Timeout The Crosspoint Status Request message has a timeout, which means that you need to wait 1 second in between request messages.

Knowledge Base Article. Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

MODBUS TCP to RTU/ASCII Gateway

METROLOGIC INSTRUMENTS, INC. IS4225 ScanGlove USB Addendum for the MetroSelect Single-Line Configuration Guide

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

PFB366 Profibus-DP Gateway User Manual

Liebert IntelliSlot Web Cards

KOYO DIRECT. HMI Setting: PLC Setting: Supported Series: KOYO DirectLogic series PLC DL05, DL06, DL105, DL205, DL305, and DL405 series.

MODFLEX MINI GATEWAY ETHERNET USER S GUIDE

Xi2000 Series Configuration Guide

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

This document explains how to use your Web Browser to configure the 100BaseT IOPRINT+ Print Server models. Connecting to the IOPRINT+ Print Server

This document explains how to use your Web Browser to configure the 100BaseT Print Server models

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

ESPA Nov 1984 PROPOSAL FOR SERIAL DATA INTERFACE FOR PAGING EQUIPMENT CONTENTS 1. INTRODUCTION 2. CHARACTER DESCRIPTION

How to setup the UCW232C Serial WiFi adapter

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

Command Emulator STAR Line Mode Command Specifications

MANUAL FOR RX700 LR and NR

S7 for Windows S7-300/400

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

Internet-bridge XPort

IP SERIAL DEVICE SERVER

Technical Bulletin. Teledyne PDS Clock Synchronization Considerations. Version 1.2

Technical Support Bulletin Nr.18 Modbus Tips

Transcription:

I-Dent Marker Communications for ARM CPU Firmware Version 3 Introduction This document will describe the Extended Protocol Communications as implemented with the InfoSight I-Dent marker software. Extended Protocol is intended to provide secure communications with an intelligent host device. This document assumes familiarity with the ASCII character code as well as fundamental computer programming skills. Note that this document is for InfoSight ARM based CPU cards running firmware version 3.x. If your I-Dent marker uses the older 186 CPU with firmware V2.x or lower, please refer to this document. Disclaimer Note: This document is correct to the best knowledge of InfoSight Corporation. InfoSight Corporation reserves the right to change this document or the system it describes without notice. Communications can be established using either of two methods: serial COM port, or Ethernet TCP/IP sockets. RS232 serial connection with the following parameters: Baud Rate Selectable 1200 to 19200 Data Bits 7 or 8 Parity ODD, EVEN or NONE Start Bits 1 or 2 Stop Bits 1 Three Wire RX, TX and GND XON/XOFF handshaking is not implemented in this marker. Ethernet TCP/IP communications requires the host to open a socket to the IP address of the marker, which must be configured to listen at a specific TCP port number. Communications with the marking controller is accomplished via a Peer-to-Peer arrangement where either side can asynchronously send messages to the other. Standard Message TYPEs The following is a list of message types which are provided with the marking system. 1 through 5 - The DATA TEXT contains a text string which is a message to be placed into the Message Text register in the field specified by the data type for the currently assigned message buffer. Since the string is stored in the Message Text register, a corresponding flag must be placed into the Format text to cause this data to be printed. The response message contains the original text string in the DATA TEXT field if no errors are detected. If an error is detected, an error message will be in the DATA TEXT field. 0 - The DATA TEXT contains a text string which consists of the message file assignment and all lines of text in a single transmission. Each of these fields, the message file name and up to 5 lines of text are separated by the ASCII TAB character. If the message file field is empty (the text begins with a single TAB character, the marker will use the currently assigned message 1

file. If the DATA TEXT field of the message is entirely empty, the marker interprets this as a request for the current message file assignment and data text fields, which will be returned in the reply. Assign a Message File A - The DATA TEXT field contains an ASCII string which is the name of the message file to load for printing. This message file becomes the default used for all further print cycles. The response message contains the message file name in the DATA TEXT field if no errors are detected. If an error is detected in the message the response will contain an error message. If the DATA TEXT field is empty, the marker will reply with the name of the currently assigned message file. Comm Link Check C - This type is used to check the communications link integrity. Any text in the DATA TEXT field will be returned in the response. An ACK response will indicate that the link is functioning properly. Clear Message Queue D - On systems where queueing of downloaded messages is required, this type is used to clear the message queue. Nothing will be returned in the DATA TEXT field of the response. Enqueue Message E - On systems where queuing of downloaded messages is required, this type is used to add one item to the message queue. Nothing will be returned in the DATA TEXT field of the response. The format of the message in the DAT TEXT field is the same as message type 0 (zero) except that the message filename is required. Force Outputs F - This type is used to have the marker force one of its output bits into the specified state. The DATA TEXT field must contain three integers, separated by TAB characters, which represent the I/O bank, the number of the output module and its desired state as follows: # <tab> # <tab> # Each number is a decimal integer. A TAB separates the three numbers. The numbers represent the following: # - Bank (0 or 1) # - Module Number (0-23) # - State (0=Off, 1=On) Note: When forcing an output, it may only stay in its forced state until the next scan of the control program. Unlike forcing an output in a PLC, this does not override the scanning logic. CAUTION: Use of this message can cause damage to the equipment or injury to personnel. Begin Marking Print Cycle (Go) G - This type is used to cause the marker to begin printing. The print cycle will only begin if the marker is On-line. The response message contains no data in the DATA TEXT field. Pulse Jets J - This message type is used to start and stop pulsing of jets on one or more print heads. The DATA TEXT field must contain three integers, separated by TAB characters, which represent the state, the head number, and the nozzle mask as follows: 2

# <tab> # <tab> # Each number is a decimal integer. A TAB separates the three numbers. The numbers represent the following: # - State (0 = stop or 1 = start) # - Head Number (1-5, or 0 for all heads) # - Mask (decimal number) Note that the Mask parameter is sent as a decimal number from 1 through 65535. This number is converted by the marker into a 16-bit binary mask, where each bit represents one nozzle of a print head. Nothing will be returned in the DATA TEXT field of the response. Marker Setup Parameters P - This type is used to send Parameter setup information to the marker. Parameter data is sent down in packets, where each packet uses the P message type. Each packet consists of one or more groups of parameters separated by CR./LF characters. Each group consists of TAB delimited fields where the first field is a three character Group Identifier. The individual parameters within the group contain a two-character field identifier followed by the equal sign and then the parameter value. Parameters are optional, meaning that you only need to send the parameters you wish to change. If a group is empty, meaning that only the group identifier is present, the marker will reply with the settings for that group in the DATA TEXT field of the reply message. The format of the data in the reply is the same as described below when sending to the marker. The message groups are as follows: BAR - This group is used to download the barcode parameters. The DATA TEXT field must formatted as follows: BAR<tab>MW=#<tab>BW=#<tab>CM=#<tab>NC=#<tab>=#<cr><lf> MW BW CM NC - Module Width - Bar Width - Checksum Modulus - Number of Characters CLN - This group is used to download the cleanup parameters. The DATA TEXT field must formatted as follows: CLN<tab>NC=#<tab>IT=#<tab>PT=#<tab>ST=#<tab>BT=#<tab>=#<cr><lf> NC - Number of Cycles (0 - x, 0 = never) IT - Idle Time (Sec) PT - Pulse Time (Sec) 3

ST - Solvent Time (Sec) BT - Blowout Time (Sec) MKR - This sub-type indicates that the DATA TEXT field contains the marker configuration parameters. The DATA TEXT field must formatted as follows: MKR<tab>O1=#<tab>O2=#<tab>PD=#<tab>NH=#<tab>NJ=#<tab>ED=#<tab>PC=#<tab> NA=#<tab>RM=#<tab>DI=#<tab>BD=#<tab>LS=#<tab>CH=#<tab>CW=#<tab>ER=#<tab>JS=#<tab> PO=#<tab>TP=#<tab>HS=#<tab>EM=#<tab>PL=#<tab>=#<cr><lf> O1 - Driver On-Time 1 (ms) O2 - Driver On-Time 2 - High Temp (ms) PD - Pulse Delay (ms) NH - Number of Heads (1-5) NJ - Number of Jets/Head (7,9,11 or 16) ED - Encoder Divider (1 ->...) PC - Pixel Count (1-40) NA - Negative Angle (0=Off, 1=On) RM - Repeat Method (0=None, 1=I/O, 2=Count) DI - Direction (0=Right, 1=Left) BD - Bidirectional (0=Off, 1=On) LS - Limit Spacing (0 ->...) (reserved, send 0) CH - Character Height (mm) CW - Character Width (mm) ER - Encoder Resolution (p / mm) JS - Jet Spacing (mm) PO - Print Offset (mm) TP - Tail End Printing (0=off, 1=on) HS - Head Sensor Spacing (mm) EM - Print End Margin (mm) PL - Product Length (mm) 4

MSG - This group is used to download the message parameters. The DATA TEXT field must formatted as follows: MSG<tab>CS=#<tab>NL=#<tab>CL=#<tab>IP=#<tab>SZ=#<tab>JU=#<tab>FO=#<tab>=#<cr><lf> CS - Character Spacing (1, 2 or 3) NL - Number of Lines (1-5) CL - Characters per Line (1-158) IP - Inverse Print (0=Off, 1=On) SZ - Slash in Zero (0=No Slash, 1=Slash) JU - Justification (0=Bottom, 1=Center, 2=Top) FO - Font (0=5x7, 1=7x9, 2=7x11, 3=11x16) (reserved, send 0) NET - This sub-type is used to download the protocol and related parameters for network communications. The DATA TEXT field must formatted as follows: NET<tab>IP=#<tab>SM=#<tab>DR=#<tab>H1=#<tab>H2=#<tab>PL=#<tab>PP=#<tab>=#<cr><lf> IP SM DR H1 H2 PL PP - IP Address - Subnet Mask - Default Router - Host 1 TCP Listen Port - Host 2 TCP Listen Port - PLC IP Address - PLC TCP Listen Port PSW - This sub-type indicates that the characters in the DATA TEXT field are new password string. The DATA TEXT field must formatted as follows: PSW<tab>PW=#<tab>=#<cr><lf> 5

PW - The new password USR - This sub-type indicates that the DATA TEXT field contains the user table parameters. The DATA TEXT field must formatted as follows: USR<tab>UM=#<tab>UY=#<tab>US=#<tab>S1=#<tab>S2=#<tab>S3<tab>=#<cr><lf> UM User Month Table (12 characters) UY User Year Table (10 characters) US User Shift Table (3 characters) S1 Start time of shift 1 (HH:MM) S2 Start time of shift 2 (HH:MM) S3 Start time of shift 3 (HH:MM) Flags (reserved, send 0) Download Message File M - This type is used to send a message file. This type allows the transmission of more than just printable text strings. The DATA TEXT field must formatted as follows: AS=#<tab>SN=#<tab>SL=#<tab>SU=#<tab>SI=#<tab>RC=#<tab>RP=#<tab>=#<tab>Fx=#<tab>Vx=#<cr><lf> AS - The name of the message file SN - Serial Number SL - Lower Limit SU - Upper Limit SI - Increment RC - Repeat Count RP - Repeat Pitch Fx - Format text for line x (x = 0 to 4) Vx - Variable text for line x (x = 0 to 4) Note that the Fx and Vx parameters, the 'x' is actually a number from 0 to 4 representing the corresponding line number. These fields may each be repeated up to 5 times in the same packet as needed (e.g. F0= F1= etc.) 6

Query for Status S - This type is used to query the marker for its current status. There can be an optional character DATA TEXT field for this type. If you include an ASCII '1' character in the field, this will enable the automatic reporting of status information. The marker will begin sending asynchronous 'S' messages to the host whenever there is a change in the status. An ASCII '0' character in the field will turn off automatic status updates. If the field is empty, then the reply will contain the status. The ACK response message from the marker will contain a DATA TEXT field. This field will contain eight numbers separated by TAB characters. These numbers represent the following values. The numbers must be converted into binary, where each bit will represent the state of an input or output point. #<tab>#<tab>#<tab>#<tab>#<tab>#<tab> STATE Marker State # - The value of the current state of Port 0 # - The value of the current state of Port 1 # - The value of the current state of Port 2 # - The value of the current state of Port 3 Set Time and Date T - This type is used to set the time and date of the marker's built-in clock/calendar. The DATA TEXT field for this message must contain the time and date separated by a TAB character in the following format: HH:MM <tab> MM/DD/YY HH:MM MM/DD/YY - The current time of day in military 24 hour format - The current date There is no data in the DATA TEXT field of the response message. Conclusion This concludes the description of the Extended Protocol for communications with the InfoSight Corporation I-Dent Marking System Software. Please refer all questions to the factory. Specifications are subject to change without notice. I-Dent is a registered trademark of InfoSight Corporation. 2015 InfoSight Corporation 7