SRS-100 Solar Radiation Sensor Installation and Setup Instructions

Similar documents
Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Traditional Sonar and DSI Sonar Installation

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

BBWX1 Satellite Weather Receiver. Installation and Maintenance Guide

16/32 Channel 1U Rack Mount CCTV Power Supply

Universal Vehicle Power Supply 9007AX01. Installation Instructions

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

TS93 EMR T/PT/TDE. Surface applied door closer

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Mounting Plate / Screwdriver. Alignment Stickers Screws / Desiccant Bag / Double-sided Tape / Rubber Seal Plug / Rubber Washer

ECM-D70T / ECM-D70T1.5

IXOLAR TM High Efficiency SolarMD.

Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual

I NTERFACE CABLE ADAPTER MODULE

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

VOYAGER 570G. 744A Sprayer Control

How To Wire Wireline Cable To A Cell Phone (New Zealand)

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

Schneider Automation Modbus Plus Network Installing Clustered Node Devices Version 2.0

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

The Fan-Aspirated ISS includes these components: Metric Rain Adapter. The hardware shown here is provided for assembly and mounting:

WIRELESS STATUS MONITOR

Advantium 2 Plus Alarm

INSTALLATION INSTRUCTIONS

Subminiature Load Cell Model 8417

Wind Direction Smart Sensor (S-WDA-M003)

Installation Guide. GPS vehicle security, recovery and location awareness

Model SRMD Setra Remote Monitoring Display

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

HID H4 BI-XENON FITTING GUIDE. Carefully read the following notes before starting work.

Knob Potentiometer FEATURES. P16NP P16NM Panel Cutout. Thickness nut 2 mm washer 1.5 mm. Panel sealing ring 12 wrench Thread M10 x

TruPower-Portable-500W. Solar Starter kit

SDX Submersible Depth Transmitter User Manual

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

GSD 22 Sounder Module. installation instructions

Active and Passive Sash Replacement

Knob Potentiometer with Switch

IntelliChlor Flow-Temperature Switch Replacement Kit Installation Guide

A99B Series Temperature Sensors

Manual. Solar Fountain Mobile Phone Charger

DirectCommand Installation DirectCommand 3-Channel Spreader Kit

Installation Guide of Sunrise Solartech PV Modules. Term Contents. Purpose of this guide. General. Safety precaution for installing a solar

7 Watt Solar Charger Solar Panel

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Installing the Broadband Global Area Network (BGAN) Fixed Mount Kit

StorTrends 3400 Hardware Guide for Onsite Support

Part I - Installation

PROXIMITY CARD READERS C-10, C-20, C60, C70

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Back-Up Camera Installation Guide

Energy Pathways in Earth s Atmosphere

Vehicle Power Install Kit

DSM155 Digital LED Light Meter User s Manual DSM155

PCS300 Universal IP Reporting Module V1.0

WIRELESS REMOTE ASSEMBLY, 24VDC, 1 TRANS,1 REC

Complete System Shelter

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Expanding a 40-Type Cabinet

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Amplified High Speed Fiber Photodetectors

A-Series Data Loggers PRODUCT MANUAL

Tipping Bucket Rain Gauge Models 6011-A 6011-B

MODEL 2202IQ (1991-MSRP $549.00)

Dual Laser InfraRed (IR) Thermometer with Color Alert

Installer s Guide WARNING: 18-GJ11D1-2. Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

INSTALLATION AND OPERATION MANUAL

Radiant Temperature Sensor TY7321

4 Small Cables Sealing Kit: Wrap Style

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

5800 Temperature Sensor Cable Assembly

Assembly Instructions: Shortwave Radio Kit

Talon and Talon SR User Manual

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Transducer Installation

Global Water Instrumentation, Inc.

LED MOTION ACTIVATED FLOOD LIGHT

12 Volt 30 Amp Digital Solar Charge Controller

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

Scotch-Weld PUR Easy 250 Adhesive Applicator

Part Name/Description Part Number Quantity. Power Cable

Retractable Screen. Replacement Screen Instructions

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

INSTALLATION INSTRUCTIONS

Installing Your 960 or 980 Server into a Rackmount Cabinet

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

By SP Partners, LLC. INSTALLATION GUIDE. Prestige

4.3-inch Back-Up Camera

Peltier Application Note

AutoDome Easy II. VEZ Series. Mounting Manual

ExStik TM ph Waterproof Meters

Dual Laser InfraRed (IR) Thermometer

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Transcription:

SRS-100 Solar Radiation Sensor Installation and Setup Instructions Revision 1.08 Jan 2010 Pace Scientific Inc www.pace-sci.com Tel: 704-799-0688 sales@pace-sci.com 1

Disclaimer The following warranty and liability disclaimer apply to this product. PACE SCIENTIFIC INC ( PACE ) MAKES NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE REGARDING ITS HARDWARE AND SOFTWARE PRODUCTS. PACE DOES NOT WARRANT, GUARANTEE OR MAKE ANY REPRESENTATIONS REGARDING THE USE OR THE RESULTS OF THE USE OF ITS HARDWARE AND SOFTWARE PRODUCTS IN TERMS OF THEIR CORRECTNESS OR OTHERWISE. THE ENTIRE RISK AS TO THE RESULTS AND PERFORMANCE OF ITS HARDWARE AND SOFTWARE PRODUCTS IS ASSUMED BY YOU. THE EXCLUSION OF IMPLIED WARRANTIES IS NOT PERMITTED BY SOME STATES. THE EXCLUSION MAY NOT APPLY TO YOU IN NO EVENT WILL PACE, ITS OFFICERS, EMPLOYEES OR AGENTS BE LIABLE TO YOU FOR ANY CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES (INCLUDING DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION AND THE LIKE) ARISING OUT OF THE USE OR THE INABILITY TO USE ITS HARDWARE AND SOFTWARE PRODUCTS EVEN IF PACE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL DAMAGES, THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU. PACE PROVIDES THIS DOCUMENTATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you. This documentation could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in later editions. Pace Scientific Inc. may make improvements and/or changes in the product(s) and/or program(s) described in this documentation at any time without notice. Copyright 2007-2010 Pace Scientific Inc. All rights reserved. Pace Scientific Inc www.pace-sci.com Tel: 704-799-0688 sales@pace-sci.com 2

The Pace SRS-100 Solar Radiation Sensor measures solar irradiance from 300 to 1100 nanometers. It may be used with the Pace XR5 Data Logger as part of a solar energy data logging system. It is also suitable for agricultural and botanical applications. Some assembly is required, as detailed on the following pages. *** IMPORTANT! *** Do not touch the small white diffuser at the top of the sensor. Any skin oil on the white diffuser will degrade the sensitivity of the sensor. To remove any oil present, clean the diffuser with a clean swab and ethyl (denatured) alcohol. Do not use rubbing alcohol. The SRS-100 Solar Radiation Sensor consists of the following components: Shield The outer shell shields the sensor body from thermal radiation and provides a path for convection cooling of the body, which minimized heat build-up in the sensor interior. The shield provides a cutoff ring for cosine response, a level indicator, and fins to aid in aligning the sensor with the sun's rays. Body The body houses the following components: Diffuser Welded to the body for a weather-tight seal. Provides excellent cosine response. Detector An hermetically sealed silicon photodiode. Amplifier The amplifier converts detector current into a 0-2.5v signal Pace Scientific Inc www.pace-sci.com Tel: 704-799-0688 sales@pace-sci.com 3

Mounting Hardware Please make sure you have all components listed below before continuing. Shield Body with cable attached Mounting hardware: (For installing and leveling the sensor) Three #6-32 x 1-1/2" (38 mm) machine screws Three springs Three #6 flat washers Three #6 screw retainers Three #4 screw retainers Three wood screws TOOLS AND MATERIALS NEEDED Medium Phillips screwdriver Center punch or nail (if mounting on wood) Drill with 7/8" (22 mm) drill bit and if mounting on wood: Softwood: 1/16" (1.6 mm) drill bit Hardwood: 5/64" (2 mm) drill bit Will you install the Sensor level or at an angle? For measurements to monitor the irradiance on a solar voltaic or thermal collection panel the data is probably most relevant if the sensor is tilted to the same angle as the collection panel. For evapotranspiration (ET) or environmental measurements, the sensor can be mounted on any level surface. For measurements where the immediate effect on humans is of interest, we suggest that the sensor be mounted so that its axis is aligned with the sun s rays at solar noon. This will maximize the mid-day readings and provide what is probably a more accurate measure of the solar radiation people are exposed to. Pace Scientific Inc www.pace-sci.com Tel: 704-799-0688 sales@pace-sci.com 4

Mounting the Sensor The Sensor may be mounted on wood or metal. For mounting on wood: 1. Using the drill template on the next page, mark the location of the necessary pilot holes. 2. Using a drill with a 3/32" (2.5 mm) drill bit, drill pilot holes in the marked locations. Bore a 7/8" (22 mm) hole through the mounting surface to provide clearance for the bottom of the sensor. 3. Route the sensor cable through the hole in the wood. 4. Place the shield onto the body as shown. 5. Place a flat washer over the end of each wood screw and insert it into the body. 6. Place a spring over the end of each wood screw and hold the springs in place using a #4 screw retainer. 7. Secure the sensor to the mounting surface by driving the wood screws into the appropriate holes as shown below. 8. For mounting the sensor level, use the bubble level on the sensor as a guide, and adjust the sensor until it is level by tightening or loosening the leveling screws as necessary. 9. Secure the sensor cable. Pace Scientific Inc www.pace-sci.com Tel: 704-799-0688 sales@pace-sci.com 5

Drill template for mounting the SRS-100 Solar Radiation Sensor If mounting on wood, drill pilot holes for three #6 wood screws as shown above. Use 1/16" (1.6 mm) drill for softwood Use 5/64" (2 mm) drill for hardwood If mounting on metal, drill holes for three #6 machine screws using a #27 (0.144", 3.7 mm) or 5/32" (0.156" or 4 mm) drill bit. Pace Scientific Inc www.pace-sci.com Tel: 704-799-0688 sales@pace-sci.com 6

Extending the Sensor Cable The SRS-100 has a 2 ft cable terminated with an RJ11 phone plug. In dry environments, this cable can be extended using a phone line coupler and an additional length of phone cable. For non-dry environments, cut the phone plug off the end of the cable and strip off about 1.5" of the black outer sheath (being careful not to cut into the insulation of the internal wires). The four leads can then be spliced to any four conductor extension cable using crimp lugs or any suitable splicing method. Notes: Since the Red and Black leads are both "ground", they can both be connected together and a three conductor cable used for the extension cable. Pace offers the WE-100 Extension Cable (100 ft / 30 meters) which includes a weatherproof splice kit. Routing the Sensor Cable Secure any extension cable at approximately 4 ft intervals, so that is does not whip about in the wind. Note: Make sure the sensor cable is not taut where it enters the sensor body. Provide some slack for cable contraction due to seasonal temperature variations. Final Adjustments If it is desirable for the sensor to be oriented to solar noon, wait until solar noon time, and then follow the steps below: Pace Scientific Inc www.pace-sci.com Tel: 704-799-0688 sales@pace-sci.com 7

Wiring Connections An earlier version of the SRS-100 had a 40 ft cable and a different wiring color code. All SRS-100 models shipped after April of 2008 have a 2 ft cable and are wired as follows: SRS-100 with 2 ft cable SRS-100 Cable XR5 Terminal Function Green Channel 1-8 Output signal: 1.67 mv per W/m 2 Red C Ground Black C Ground Yellow E Power: +5V DC, 1 ma Discontinued SRS-100 with integral 40 ft cable SRS-100 Cable XR5 Terminal Function Yellow Channel 1-8 Output signal: 1.67 mv per W/m 2 Red C Ground Green C Ground Black E Power: +5V DC, 3 ma Pace Scientific Inc www.pace-sci.com Tel: 704-799-0688 sales@pace-sci.com 8

LogXR Software Setup for all XR5 models. (See page 10 for XR440). Scaling: In the Setup Screen, select channel tab number that the SRS-100 is wired to, and select/enter the following: Type: 0-2.5V For units of W/m 2 Slope: 600 Offset: 0 For units of foot candles in sunlight* Slope: 9170 Offset: 0 * The SRS-100's calibration for foot candles is for sunlight only. Please see "Note on light measurement" (below) for details. Excitation: Sensor excitation is selected in the Main tab of the Setup screen. The SRS-100 requires a minimum of 30ms of excitation. Any XR5 setup meets to this requirement. A Sensor Excitation of 30ms is recommended for best battery life, unless other connected sensors require a longer excitation time (see note below). Note: Sensor Excitation must be set to the longest excitation time required by all the connected sensors. For example, if a P1510-25 Pressure Sensor is also connected to the XR5 data logger (which has an excitation requirement of 150ms), then select a Sensor Excitation of 150ms. Note on light measurement The SRS-100 Solar Radiation Sensor measures solar irradiance, or the instantaneous quantity of sunlight striking a particular surface area. Units of measurement for irradiance include Watts per square meter (W/m 2 ) and lumens per square foot (foot candles). The above slope/offset scaling for foot candles is valid only for sunlight. The SRS-100 is calibrated for solar radiation in watts per square meter. Watts per square meter is a radiometric unit. Radiometric units are based on physical power, and all wavelengths are equally weighted. Foot candle is a photometric unit which takes into account the human eye's response (sensitivity) to the visible light spectrum. Converting the SRS-100's readings from Watts per square meter to Foot Candles must take into account the spectral composition of the light source. For example, the spectral composition of high pressure sodium lamps, low pressure sodium lamps, metal halide lamps, incandescent lamps and florescent lamps compared to sunlight are all significantly different. If the above slope and offset scaling values for foot candles are used for a light source other than sunlight, a significant measurement error (of up to a factor of 2) will result. Pace Scientific Inc www.pace-sci.com Tel: 704-799-0688 sales@pace-sci.com 9

Specifications General Operating Temperature -40 to 150 F (-40 to 65 C) Measurement Range 0 to 1500 W/m 2 Accuracy ±5% Drift Temperature Coefficient up to ±2% per year 0.067 % per degree F (0.12 % per degree C); negative correction above ref. temperature, positive correction below ref. temp. Reference temperature = 77 F (25 C) Resolution with XR5 Data Logger 0.37 W/m 2 (using 0-2.5v input range) Resolution with XR440 Pocket Logger 0.73 W/m 2 Signal Output 0-2.5vdc; 1.67 mv per W/m 2 Power Requirement 5vdc with 1 ma typical current draw Sensor Type Spectral Range (10% points) Cosine Response Percent of Reading Silicon photodiode 400 to 1100 nanometers ±3% (0 to ±70 incident angle); ±10% (±70 to ±85 incident angle) Percent of Full Scale ±2% (0 to ±90 ) Attached Cable Length 22" (55 cm) Cable Type 4-conductor, 26 AWG Recommended Maximum Cable Length 125 FT (38 m) Housing Material UV-resistant plastic Dimensions 2 x 2.75 x 2.25 (51 mm x 70 mm x 57 mm) Weight 12 oz. (340 g) Technical Support For questions or comments regarding this document, please contact Pace Scientific Technical Support: Phone: 704-799-0688 (8-5pm EST) Email: support@pace-sci.com Fax: 704-799-0177 Pace Scientific Inc www.pace-sci.com Tel: 704-799-0688 sales@pace-sci.com 10

Using with the XR440 Data Logger Wiring Connections An earlier version of the SRS-100 had a 40 ft cable and a different wiring color code. All SRS-100 models shipped after April of 2008 have a 2 ft cable and are wired as follows: SRS-100 with 2 ft cable SRS-100 Cable XR5 Terminal Function Green Channel 1-8 Output signal: 1.67 mv per W/m 2 Red C Ground Black C Ground Yellow E Power: +5V DC, 1 ma Discontinued SRS-100 with integral 40 ft cable SRS-100 Cable XR5 Terminal Function Yellow Channel 1-8 Output signal: 1.67 mv per W/m 2 Red C Ground Green C Ground Black E Power: +5V DC, 3 ma Pocket Logger Software Setup Scaling: In the Setup Screen, click the Scaling drop down list for the channel that the SRS-100 is wired to, and select New Linear Scale and then enter the following scaling values: For units of W/m 2 High Value: 3000 Low Value: 0 For units of foot candles in sunlight* High Value: 45,850 Low Value: 0 * The SRS-100's calibration for foot candles is for sunlight only. Please see "Note on light measurement" (page 9) for details. Pace Scientific Inc www.pace-sci.com Tel: 704-799-0688 sales@pace-sci.com 11