Miniature Motors Deliver Big Performance for Medical Analyzers. by Udayan Senapati, Ph.D.

Similar documents
Brush DC Motor Basics. by Simon Pata Business Unit Manager, Brushless DC

BRUSHLESS DC MOTORS. BLDC 22mm. BLDC Gearmotor Size 9. nuvodisc 32BF. BLDC Gearmotor Size 5

Introduction to Linear Actuators: Precision Linear Motion Accomplished Easily and Economically

10 tips for servos and steppers a simple guide

The Emergence of Brushless DC Motors Within Medical Applications

Small Coreless DC Motors

How to Optimize Performance and Minimize Size in High Speed Applications High Performance Brushless DC Motors

Chen. Vibration Motor. Application note

CNC Machine Control Unit

BRUSH DC motors. Brush DC 8mm. Motor Coil Cross Section. Brush DC 16mm. Brush DC 35mm

Motors and Generators

INSTRUMENTATION AND CONTROL TUTORIAL 2 ELECTRIC ACTUATORS

Miniature High-Torque, DC Servomotors and DC Gearmotors

WHITE PAPER. DC Motors Explained. DC Motors Explained: White Paper, Title Page

UNIT II Robots Drive Systems and End Effectors Part-A Questions

Introduction to Linear Actuators: Precision Linear Motion Accomplished Easily and Economically

AUTOMATED, FULL LOAD MOTOR TESTING AT PRODUCTION SPEEDS

D.C. Motors. Products and specifications subject to change without notice.

Borstlösa DC-motorer. Promoco Scandinavia AB

Torque motors. direct drive technology

10. CNC Hardware Basics

Alternative Linear Motion Systems. Iron Core Linear Motors

Motor Selection and Sizing

Application Information

EDUMECH Mechatronic Instructional Systems. Ball on Beam System

Stepper motor I/O. Application Note DK Motion Control. A General information on stepper motors

DIRECT CURRENT GENERATORS

Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA

Thermodynamic efficiency of an actuator that provides the mechanical movement for the driven equipments:

Motors. 13/16 Siemens PM

CHAPTER 4 DESIGN OF INTEGRAL SLOT AND FRACTIONAL SLOT BRUSHLESS DC MOTOR

Permanent Magnet DC Motors

Tips For Selecting DC Motors For Your Mobile Robot

Robot coined by Karel Capek in a 1921 science-fiction Czech play

Motor Fundamentals. DC Motor

CNC HARDWARE & TOOLING BASICS

Lab 8: DC generators: shunt, series, and compounded.

Electric Motors and Drives

Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l

Digital vs. Analogue Control Systems

Synchronous motor. Type. Non-excited motors

CIM Computer Integrated Manufacturing

Principles of Adjustable Frequency Drives

Miniaturized linear motion

Inductance. Motors. Generators

MSc in Autonomous Robotics Engineering University of York

Flow Charts and Servomotors (background to Lab #2) Things to learn about: flow charts for design. MECH Lecture #2 flow charts & servos rev2

How to Turn an AC Induction Motor Into a DC Motor (A Matter of Perspective) Steve Bowling Application Segments Engineer Microchip Technology, Inc.

Field and Service Robotics. Odometry sensors

Application Information Fully Integrated Hall Effect Motor Driver for Brushless DC Vibration Motor Applications

Chapter 11 SERVO VALVES. Fluid Power Circuits and Controls, John S.Cundiff, 2001

hybrid stepper motors

Active Vibration Isolation of an Unbalanced Machine Spindle

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS

Series: IDAM Servo Drive E Digital Motor Drive - DMD

Technical Guide No High Performance Drives -- speed and torque regulation

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.

Simple Analysis for Brushless DC Motors Case Study: Razor Scooter Wheel Motor

Advantages of Auto-tuning for Servo-motors

Six Trends in Robotics in the Life Sciences

BALDOR ELECTRIC COMPANY SERVO CONTROL FACTS A HANDBOOK EXPLAINING THE BASICS OF MOTION

Development of the Induction Motor for Machine Tool Spindles and Servo Amplifier SANMOTION S

X8 Option 2 - Technology

DC Motor control Reversing

Laminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers

MDM-5000 DIRECT DRIVE SETS

Micro-Step Driving for Stepper Motors: A Case Study

Autonomous Mobile Robot-I

MEDICAL APPLICATION SOLUTIONS from Allied Motion Technologies

BMD. Permanent Magnet AC Synchronous Motors

Introduction to Process Control Actuators

How to design an insulin pump

LINEAR MOTOR CONTROL IN ACTIVE SUSPENSION SYSTEMS

Design Aspects of Robot Manipulators

An overview of Computerised Numeric Control (C.N.C.) and Programmable Logic Control (P.L.C.) in machine automation

Design of an Insulin Pump. Purpose of an Insulin Pump:

CE801: Intelligent Systems and Robotics Lecture 3: Actuators and Localisation. Prof. Dr. Hani Hagras

MATHEMATICAL MODELING OF BLDC MOTOR WITH CLOSED LOOP SPEED CONTROL USING PID CONTROLLER UNDER VARIOUS LOADING CONDITIONS

Setting up the DeskCNC controller.

dspace DSP DS-1104 based State Observer Design for Position Control of DC Servo Motor

Speed Control Motors. Speed Control Motors. Brushless Motor's Structure and Principle of Operation H-40. Structure of Brushless Motor

Selection Procedure B-24 ORIENTAL MOTOR GENERAL CATALOGUE

Servo Motor Selection Flow Chart

C Standard AC Motors

NECOCAR. International CATIA Project

Digital to Analog Converter. Raghu Tumati

Lab 14: 3-phase alternator.

Solution: Angular velocity in consistent units (Table 8.1): Velocity of a point on the disk: Rate at which bits pass by the read/write head:

Phase-Control Alternatives for Single-Phase AC Motors Offer Smart, Low-Cost, Solutions Abstract INTRODUCTION

AC Servo Motors and Servo Rated Gearheads

Sensors Collecting Manufacturing Process Data

AC generator theory. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

A descriptive definition of valve actuators

Vehicle Design Summit Electric Hub Motor (V2) Eric Conner Harvey Tang Matthew Peddie

Application and Design of the ebooster from BorgWarner

TOYOTA ELECTRONIC CONTROL TRANSMISSION

The DC Motor/Generator Commutation Mystery. Commutation and Brushes. DC Machine Basics

Discover the power of e-learning! The Quick Guide to AC Variable Frequency

LOW VOLTAGE D.C. MOTORS & GEARBOX UNITS

Transcription:

thinkmotion Miniature Motors Deliver Big Performance for Medical Analyzers by Udayan Senapati, Ph.D.

Miniature Motors Deliver Big Performance For Medical Analyzers Medical analyzers are the workhorse of the medical diagnostics industry. They are versatile tools with multiple functions; from testing human bodily fluids such as blood, and urine, to processing drug-protein interaction studies that deliver key information for the diagnosis, prevention and treatment of disease. Different types of analyzers perform sample movements for analysis with different motorized solutions (motor, encoder) and transmission mechanisms (pulley, belt, gearing). And in the quest to design medical analyzers to deliver better, safer, more personalized and cost efficient healthcare, the most common criteria for analyzer automation are high quality, low noise and long life, at an attractive cost. Numerous motors/gearing/encoders are used to transport fluids, vials or assays within medical analyzers. Stepper motors are ideally suited for low rate sampling analyzers such as blood sugar testers that run 1-10 samples an hour, while state of the art brush and brushless coreless motor technologies function well in high throughput applications (on the order of more than 1000 assays an hour), such as immunochemistry or DNA screening. Some medical analyzers use a turn table-based approach (fig. 1) to stack assays that are identified, marked and serialized to track human fluids, enabling labs to deliver timely and accurate feedback to the health care professionals. Figure 1: Motorized turn table with assays. The quantity of assays would depend on the required throughput. Brush DC Coreless Motor Stepper Motors In the simplest versions of such turn table analyzers where speed is not a primary issue, stepper motors are a Figure 2: An assay being punctured and sample withdrawn for analysis using a brush coreless DC mechanism in a plunger drive.

reliable, cost effective method of meeting the analyzer s functional requirements. A stepper motor is essentially a BLDC motor with many poles; thus, the current in each phase has to be commuted many times per revolution. For instance, a 2-phase stepper with 100 steps / revolution will need 25 current reversions in each phase to make one full revolution. A primary advantage to analyzers that utilize stepper motors is that they have many stable positions (steps) per revolution while providing a high torque for a given size (as an example, a Portescap 16 mm Disc Magnet Motor can offer up to 5-6 mnm of torque). The disadvantage of utilizing a stepper motor is that it is not able to run at high speed (>2000 rpm), due to the inductance combined with the commutation frequency, and iron losses (current reversed so many times). That said, a range of steppers - from permanent magnet to hybrid to linear - are available to satisfy analyzer application needs. Permanent magnet can-stack steppers are suitable for analyzers when space and power demands are critical. Hybrid steppers are small, powerful and cost effective enough to be used in analyzers. Linear stepper systems are also ideally suited for many analyzer applications, offering advantages such as limited maintenance or wear, simplicity of integration and part reduction versus standard rotary systems. Rotary Angular Speed (rpm) 9000 8000 7000 6000 5000 4000 3000 2000 1000 0 0 5 10 15 20 25 30 35 40 45 Time (ms) systems typically need translation mechanisms to transfer rotary motion to linear motion, thus increasing part count and integration complexity. Linear steppers are ideal for analyzers requiring light loads and open-loop performance, and due to the lower inertia associated with fewer components, they can typically accelerate faster than rotary systems. Brushless DC Coreless Motors For high throughput applications - those where over a thousand assays are analyzed in an hour - high efficiency and higher speed motors such as brush DC coreless motors are a suitable choice. Their low rotor inertia (a 22 mm diameter Portescap motor has motor inertia in the range of (10 30) x 10-6 kgm2) along with short mechanical time constant makes them ideally suited for such applications. As an example, a Portescap 22 mm motor brush coreless DC motor offers no-load speed of 8,000 rpm and a mechanical time constant of 6.8 milliseconds. The time required for the motor to attain such speeds is governed by the equation: w = w o (1- exp (-t/t m )) where w o is the no load speed, t m is the mechanical time constant of the motor and w is the speed attained after a certain lapse in time t. Based on the motor characteristics, 90% of the no load speed can be attained in the turn table application in about 15 milliseconds as shown in Graph 1. It should be noted that the load characteristics on the motor, depending on the torque required to turn the assay sample table at a certain speed, would determine the actual time the motor takes to ramp up to a certain speed. Graph 1: The above graph illustrates the amount of time it takes fora brush DC motor to attain no-load operating speeds.

Disc magnet stepper motors and brushless DC motors can also work in variants of this application based on speed, acceleration, performance and cost requirements. Encoder Motor Gear Another analyzer function that plays a vital role in their output is collecting samples from the vials or assays, and serving them up to measurement systems based on photometry, chromatography or other appropriate schemes. Open tube or close tube format samples assays are typically presented to a piercing or plunging mechanism via the turn table for suction of the sample from the vial, with disposition to a measurement system (fig. 2). Figure 3: Portescap Brush DC Coreless Gear Motor with Encoder In some critical applications where the sample size available for analysis is limited, motor characteristics such as speed, torque, efficiency and positioning accuracy play a significant role. Here again a brush DC coreless motor is highly applicable due to the power density it packs in a small frame size. And as mentioned earlier, the low inertia of a brush DC coreless motors aids in efficient fluid transport, especially in cases where the requirements for sample availability are in the micro liter range. Typically an incremental encoder can be used for feedback with a brush DC coreless gearmotor (Figure 3) to gauge motor position and speed. Such incremental encoders can be optical or magnetic, and produce pulses (Figure 4) that are proportional to speed and distance. High encoder resolution of >128 lines is typically desired at lower speeds of <1,000 rpm, such as during the final stages of suctioning fluids from the vials. Figure 4: Pulse sequence in a magnetic encoder Hybrid Stepper Motors An extension of the application uses pumps with stepper motors to dispense certain reagents into the assays in order to aid the analysis process. Such stepper motors can be controlled using open or closed loop feedback. A hybrid motor such as that shown in Figure 5, can be used in different axes to position the test samples under appropriate reagent dispensers, and a closed loop system, although more expensive, might be justifiable in such a case.

If power density, efficiency, speed and value are primarily important criteria, then brush DC coreless might be the technology of choice. If positioning without added electronics and low cost are the primary requirements, as in low rate sampling analyzers, then steppers could be the preferred option. The user has to make a selection based on performance-to-price needs, keeping in perspective the costs associated with control electronics and drives, along with the life span of such analyzers which can run 15 20 years, and the application needs the analyzers serve, in the heath care segment. Figure 5: Portescap Hybrid h3 Step Motor A typical can stack motor has discrete angular positions where the shaft is retained in discrete positions using a holding torque. As an example, a 15 mm can stack motor with an 18 degree step angle can be run in open loop without a feedback sensor, but the positioning would be crude. On the other hand, a hybrid motor with closed loop system can have an encoder for position feedback to the drive electronics, with added encoder costs of $10 - $25, and costs for drive electronics enhancements. Summary The performance-to-price consideration of an appropriate motion solution ultimately depends on the complexity of the analyzer, along with the precision, efficiency and environmental conditions required for the operation. A range of different motor technologies are applicable for different motion requirements and axes of operation in a medical analyzer, as shown in Table 1. Portescap www.portescap.com 2009 Portescap, A Danaher Motion Company. ALL RIGHTS RESERVED.

BONUS! Price to performance of different motor technologies applicable for use in medical Analyzers Attributes Brush DC Corless Motor Technology Comparison Brush DC Iron Core BLDC Slotted BLDC Slotless Stepper Can Stack Stepper Hybrid Performance Power Density High Low High Medium Low Low Speed Medium Low High High Low Low Noise Medium High Low Low Medium Medium Positioning without No No No No Yes Yes Electronics? Starting Voltage Low High High High High High Efficiency High Low Medium Medium Low Low Value in Use Price Medium Low High High Low Medium Cost of ownership Low High High Medium High Medium Ease of integration? Yes Yes No No Yes Yes Design Flexibility Compactness High Low Medium High Medium Low (power to size) Customization Medium Medium High Medium Medium Low *Power density reflects the output power from the motor in a certain frame size *Speed reflects the speed at output shaft of the motor in rpm *Efficiency is a measure of input power that is converted to output power *Cost of ownership is a mix of price, electronics, life of motor, ease of installation and service *Customization reflects application specific needs in product design and, hence, a BLDC slotted will need a high level of customization compared to hybrid stepper thus resulting in significant higher costs Portescap www.portescap.com 2009 Portescap, ALL RIGHTS RESERVED.