ISOLATION AND NOISE FILTRATION IN THE MODERN FACILITY

Similar documents
Power Quality For The Digital Age INVERTING SOLAR POWER A N E N V IRONME N TA L P OT E N T I A L S W HI T E PA PER

Technical Article. EMC filters for medical devices

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

HARMONIC DISTORTION IN THE ELECTRIC SUPPLY SYSTEM

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

Conducted EMI filter design for SMPS

White Paper: Electrical Ground Rules

Video Camera Installation Guide

Line Reactors and AC Drives

Common Mode Filter Inductor Analysis

Grounding Demystified

PWM Motor Drives and EMC in installations and systems

Power surges can also be generated by equipment in your facility such as:

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

Understanding Power Splitters

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

Specifying a Variable Frequency Drive s

Harmonic components: electrical network polluters. LV and MV networks are becoming increasingly polluted by current and voltage harmonics. Harmonics a

EMI in Electric Vehicles

Common Mode and Differential Mode Noise Filtering

Grounding and Shield Termination. Application Note 51204

APPLICATION NOTE How to Deal with Electrical Noise and Interference in the Measuring Chain using a NEXUS

INTRODUCTION TO HARMONIC ASSESSMENT IN POWER SYSTEMS

Application Note. Troubleshooting Communications

DESIGNING MODERN ELECTRICAL SYSTEMS WITH TRANSFORMERS THAT INHERENTLY REDUCE HARMONIC DISTORTION IN A PC-RICH ENVIRONMENT

SELECTING PROPER CONNECTION POINTS FOR Y-CAPACITOR TO REDUCE EMI IN SMPS

POWER LINE FILTERS FOR SWITCHING POWER SUPPLIES

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

Understanding Power Splitters

DRAFT. University of Pennsylvania Moore School of Electrical Engineering ESE319 Electronic Circuits - Modeling and Measurement Techniques

Chapter 4. LLC Resonant Converter

GENERAL POWER SYSTEM WIRING PRACTICES APPLIED TO TECNADYNE DC BRUSHLESS MOTORS

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Application Note AN:005. FPA Printed Circuit Board Layout Guidelines. Introduction Contents. The Importance of Board Layout

Electrical Essentials for HVAC&R Engineers. Wednesday, October 7

MOBILE SYSTEM FOR DIAGNOSIS OF HIGH VOLTAGE CABLES (132KV/220KV) VLF-200 HVCD

The following table shows approximate percentage wise the

Pulsed Power Engineering Diagnostics

Common Mode Choke Filtering Improves CMRR in Ethernet Transformer Applications. Application Note. June 2011

Unified requirements for systems with voltages above 1 kv up to 15 kv

Advantages of 6-Pulse VFD with Lineator AUHF vs Active Front End (AFE) Drives

EMC Filters Guide REO UK LTD

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

Generic - Hearing Loop - (AFILS) U.S. System Specification

Transformers. Special transformers Reactors products

Inductors & Inductance. Electronic Components

Solving VFD-sourced Bearing Current Problems in AC Motors.

Equipment: Power Supply, DAI, Transformer (8341), Variable resistance (8311), Variable inductance (8321), Variable capacitance (8331)

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

MEASUREMENT SET-UP FOR TRAPS

A Practical Guide to Free Energy Devices

AN100. The Elusive Tapped Output Inductor. By Colonel Wm. T. McLyman

Balanced vs. Unbalanced Audio Interconnections

AC Direct Off-Line Power Supplies

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

Triplen Harmonics Mitigation 3 Phase Four-Wire Electrical Distribution System Using Wye- Zig-Zag Transformers

7. Technical Notes Table of Contents

KNX Powerline PL 110. KNX Association

13 common causes of motor failure

5. MINIMIZATION OF CONDUCTED EMI. Chapter Five. switch-mode power supply decrease approximately linearly with the increase of the switching

> Executive summary. The Role of Isolation Transformers in Data Center UPS Systems. White Paper 98 Revision 0. Contents.

Session 10: General Overview of Interconnection Standards & Grid Codes for High Penetration PV October 21, 2015 Santiago, Chile

Modeling of Transmission Lines

WHY DIFFERENTIAL? instruments connected to the circuit under test and results in V COMMON.

Lecture 24. Inductance and Switching Power Supplies (how your solar charger voltage converter works)

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Three phase circuits

TECHNICAL BRIEF. Commercial PV in Australia and New Zealand Using the Enphase Microinverter System

6 ELECTRICAL PARAMETERS

IP PHONE SYSTEM. CooVox Series-U60 For Small and Medium Business. Quick Installation Guide.

74HCU General description. 2. Features and benefits. 3. Ordering information. Hex unbuffered inverter

Case Studies in On-Line Measurement of PD in Motors Fed by Voltage Source PWM Drives

Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques

EMI and t Layout Fundamentals for Switched-Mode Circuits

Application Note SAW-Components

Radiated Emission and Susceptibility

LR Phono Preamps. Pete Millett ETF.13.

The role of grounding in automotive EMC

Fundamentals of Inverter Fed Motors

EET272 Worksheet Week 9

W a d i a D i g i t a l

SIZING THE PRIMARY POWER SYSTEM FOR RESISTANCE WELDERS

Installation Considerations for IGBT AC Drives

Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power

RC NETWORKS SALES GUIDE

Conducted EMI Issues in a Boost PFC Design

Current Ripple Factor of a Buck Converter

Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness

Module Title: Electrotechnology for Mech L7

Circuits with inductors and alternating currents. Chapter 20 #45, 46, 47, 49

How to avoid typical pitfalls when measuring Variable Frequency Drives

Multimeter measurements on variable frequency drives using the new Fluke 289 DMM

DISCRETE SEMICONDUCTORS DATA SHEET. BLF244 VHF power MOS transistor

BSNL TTA Question Paper-Instruments and Measurement Specialization 2007

EMC Installation / Application Guidelines VECTORSTAR (VSA) Series Electronics MVS001H. EMC / CE Guidelines

Harmonics in your electrical system

ElectroMagnetic Induction. AP Physics B

Considering the effects of UPS operation with leading power factor loads

Transcription:

Power Quality For The Digital Age ISOLATION AND NOISE FILTRATION IN THE MODERN FACILITY A N E N V I R O N M E N T A L P O T E N T I A L S W H I T E P A P E R

Introduction An average-sized facility can have upwards of ten electrical panels. Each panel is connected to the main panel. A typical industrial electrical panel can power several motors, VFD s (variable frequency drives), conveyor systems and computers, while a typical office panel can power several computers, phones, printers and copy machines. All electrical equipment is powered by wire fed from a panel. Likewise, the panels are fed wire from the main panel. Most importantly all panels are connected to the facility ground. This means the entire electrical distribution system is interconnected. This interconnectivity poses serious risks to power quality. All electronic, computerized and digital equipment are constantly generating noise and power pollution. This pollution circulates within the facility through the phase, neutral and ground wires. Facilities employ many methods to protect sensitive equipment from this circulating noise and pollution. One of the most common strategies is to isolate equipment with an isolation transformer. Isolation Transformers 101 An isolation transformer is a power quality device used to isolate a load from the main supply. It is made up of two separate windings separated by a metallic shield. This metallic shield is an electro static shield, called a Faraday shield, and is connected to earth ground. Figure 1 shows the structure of an isolation transformer. shielding Fig.1 Structural view of an isolation transformer Capacitance (C) (C) of the of the shielding shielding = Inductance = Inductance (L) of connecting (L) of connecting ground ground wire wire Results Results in resonance in noise amplification and heavy EMD

Typically, isolation transformers are 1:1 transformers, meaning it does not step up or step down voltage or current. Figure 1 shows that an isolation transformer Figure 2 shows the typical application of an isolation transformer connected between the supply and the load. The objective is to isolate the load that generates harmful noise or equipment that is sensitive to harmful noise from the rest of the electrical system. Noise generated on the supply side is diverted towards the ground. Isolation transformers are usually installed before the load. supply load Figure 2: Isolation transformer connected between supply and the load Electrical noise at the primary side The transformer principle is to inductively couple the supply from the primary winding to the secondary windings. However, due to the leakage in the primary windings noise transfers to the secondary winding. This noise can only be removed when the shielding is connected to the ground. The noise is diverted to the ground and the secondary winding will only get inductive reactance. Theoretically, diverting noise to ground protects the load from harmful and destructive noise.

Ground Noise and Ground Loops Facilities connect all grounds together. According to IEC 950 and UL 1950 (standards for computerized electronics under 600v range), an isolation transformer is used to isolate only the phase and neutral, but not the ground. Isolation transformers rely on a Faraday shield, which is grounded to the facility ground. However, both sides of the isolation transformer are connected to the same ground. This indicates that while the load is isolated from the electrical noise generated on the phases and neutral, it is not isolated from noise on the ground. This means an isolation transformer will NOT remove ground loops from the facility but instead will create ground loops. Ground loops can be defined as the loops generated in the facility between multiple ground rods that represent differing potentials and therefore, multiple circulating paths of impedance. Current circulating on the ground will lead to imbalance in the system and thus the electrical noise on the phases. Isolation transformers are usually installed before the load. supply load Figure 3: Electrical noise diverting to all parts of the electrical system through the ground. Electrical noise at the primary side Figure 3 demonstrates the behavior of electrical noise in the system when an isolation transformer is used. Since the electrical system relies on the same ground at both the primary and the secondary, ground noise will circulate at both the supply side and the load side. This means, isolation transformers increase ground noise. The frequency at which the inductive reactance equals the capacitive reactance is called the resonating frequency and at this frequency the electrical noise will be amplified. This means that whenever the inductance of the grounding rod equals the capacitance at the Faraday shield, electrical noise will be amplified. This is extremely harmful for the electrical system since the amplified electrical noise is sufficient to damage the load.

Examine the following measurements taken at Wheeling Corrugating in Fallon, NV. Wheeling Corrugating used an isolation transformer to isolate three VFD s from the rest of the facility. The facility was experiencing constant downtime and constant maintenance. However, the isolation transformer only exacerbated the problem. The voltage noise is at e x t r e m e l y high levels of -2dB at regular intervals. Figure 4: Noise measured at VFD with the isolation transformer installed The current noise is also at extreme levels of greater than -20 db Figure 4 measurements are taken from 3kHz to 100kHz on phase A of a VFD. The isolation transformer is magnifying the noise to extreme levels. Noise at these levels will increase malfunctions, waste energy and cause premature failure of electrical components. Isolation transformer will not reduce ground loops but increase the ground currents and electrical noise on the ground.

The EP Solution Isolating noisy equipment from the rest of the facility will significantly improve power quality. The problem is connected grounds combined with the increased use of improper electrical configurations make this isolation increasingly unattainable. Isolation transformers are not able to isolate equipment from noise in the modern facility. Figure 5 measurements are taken from 3kHz to 100kHz on phase A of a VFD after installing the EP system and removing the isolation transformer. Figure 5: High frequency noise measured at VFD after EP installed Approximately 18dB reduction in current noise Approximately 48dB reduction in voltage noise The voltage noise was attenuated by 48dB while the current noise was attenuated by 18dB. EP not only reduced the electrical noise in this facility, but also protected the sophisticated electrical drives by eliminating ground loops. Environmental Potentials patented waveform correction technology filters and removes noise between 1.5kHz-1MHz. Installing the EP system at the main panel, sub-panels and load centers isolates noisy equipment from the rest of the facility. Environmental Potentials does not shunt energy to ground and this helps eliminate ground loops. Installing EP ground filters will remove any remaining noise on the ground. This provides protection and isolation for equipment generating harmful noise and equipment sensitive to harmful noise.

1-800-996-3762 info@ep2000.com www.ep2000.com 1802 N. Carson Street, Suite 108-2987 Carson City, NV 89701