Guide: Lightning and surge protection for LED lighting Date: 08/2014

Similar documents
Class I surge protection with sparkover gaps

Transient and Lightning Protection for the Water Industries

Coaxial Cable Entry Panels, Coax and Grounding Connectors. Technical Note

Lightning Arresters P KVA P KVA. Description & Installation

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Structured Cabling, Earthing & Equipotential Bonding

Interfacing electrification and system reliability. Earthing of AC and DC railways 4,10,13

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time

SURGE PROTECTIVE DEVICES

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

Installation instructions for mains wire-in protectors ESP D1, D1R, D1/LCD and D1R/LCD variants

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

CONTINUOUS MONITORING AND AVOIDANCE OF RESIDUAL CURRENTS IN DATA CENTRES WITH RCM White paper Revision 2

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F

EMC Engineering Guidelines For Automation Systems PS 4 PS /97 AWB GB

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Video Camera Installation Guide

Protect. Surge Protection for home and small office

Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters

Grounding and Shield Termination. Application Note 51204

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

Low Voltage Switchboards The Best Technical Solution for Your Ship

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Nothing s BetterThan the Original MODAN Power Distribution Systems

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

Distributed Temperature Monitoring of Energy Transmission and Distribution Systems

HERZ-Thermal Actuators

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Voltage Regulator SPAU 341 C. Product Guide

Top Commercial / Residential Electrical Requirements *

Separation of power and information technology cabling

Power Separation Guidelines for SYSTIMAX Installations

Guide to Starters Guide to Starters Page 1 of 17

Physical Specifications (Custom design available.)

Telecommunication Line Protectors

White Paper: Electrical Ground Rules

KATO. LED Lighting High Bay und Low Bay

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

CATALOGUE SURGE PROTECTION LOW VOLTAGE

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

R.C.C.B. s two-pole LEXIC

Welcome to this presentation on LED System Design, part of OSRAM Opto Semiconductors LED 101 series.

Operating instructions IV / 2007

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

DALI RC BASIC SO. Control unit Operating instructions

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

5SV Residual Current Protective Devices

ADM1TE 5/30A DIN rail single phase two wire energy meter

Lightning current simulation in the laboratory - parameters, procedures and test equipment -

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

How can a charging station for electric vehicles be set up simply and safely?

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

Telephone- and leased line modem for industrial applications TD-36

Electrical Grounding. Appendix C

Fusible Disconnect Switch

Operating instructions II / 2004

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

1. Franklin Rod Performance 2. LEC/DAS Performance

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

Introduction to Data Centre Design

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Test Report. Date of test: OBO Bettermann GmbH & Co. Test requirements: Electrical continuity of the EN 61537

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

DuroSite TM High Bay Lighting

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006

Wireless LAN Outdoor Bridge Solution

The power of nature, the control of technology From ABB's experience, OVR PV: surge protection in photovoltaic plants

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

ABB i-bus KNX Switch Actuators SA/S Product Information

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Unified requirements for systems with voltages above 1 kv up to 15 kv

Evaluating Water-Damaged Electrical Equipment

DEHN + SÖHNE. DEHNconductor System No Problems with Proximities

Catalog. Modular DIN rail components Installation contactors

CalMod Design-Build Electrification Services

Type: DILM9 10(24VDC) Article No.:

Operation and Installation Manual

Evaluating Water-Damaged Electrical Equipment

AJ s Technical Tips: Designing a Small Solar PV System Part IV; Selecting Wires for the System

Product Safety Considerations for Insulation Coordination of Low- Voltage Equipment. Scott Aldous, Compliance Engineer

THE LIGHTNING PROTECTION INTERNATIONAL STANDARD

Sample - No Commercial Use

LDG DTS-4/4R Desktop Coaxial Switch / Remote

FIXED CHARGE: This is a cost that goes towards making the service available, including

Transcription:

Guide: Lightning and surge protection for LED lighting Date: 08/2014

Table of contents Chapter 1. Lightning and surge protection for LED lighting....3 Chapter 1.1 Basic principles:...3 Chapter 1.2 Risks:...3 Chapter 2. Street lighting...4 Chapter 2.1 Damage and repair costs...4 Chapter 2.2 Creation of the earthing systems...4 Chapter 2.3 Installation location of the lightning and surge protection...5 Chapter 3. Internal lighting....7 Chapter 4. Connection...8 Chapter 4.1 Parallel connection...8 Chapter 4.2 Serial connection...8 Chapter 5. Conclusion...9 Chapter 6. Literature index:...10 These sheets provide you with information on specific technical subjects. They are based on the currently known and valid rules and regulations and on our experience. The contents of this document are not legally binding and make no claim to completeness.

Lightning and surge protection for LED lighting Chapter 1. Chapter 1.1 Chapter 1.2 Lightning and surge protection for LED lighting Basic principles: Due to their light intensity, their energy efficiency and their robustness, LED luminaires are ideally suitable for street lighting and signal and object lighting in industrial and commercial premises. As LED luminaires consume up to 70 per cent less energy than standard lighting, whilst still producing the same luminous power, they can make a significant contribution to the reduction of energy costs over their lifespan of up to 100,000 hours. By comparison: Metal-halide lamps only have a lifespan of up to 20,000 hours. For this reason, the increased purchasing price of LED luminaires amortises within a short time, if protected against advance failure through direct lightning strikes and switching surge voltages. Risks: In the field of street lighting, LED luminaires are directly exposed to close and distant lightning strikes and surge voltages, on account of their exposed position. When switching fluorescent tubes or HQI luminaires in buildings, there is the risk of damage or premature ageing on account of the high switching surge voltages of up to 5,000 volts. These loads can lead to a reduction in the luminous intensity or to the destruction of the electronic ballasts. There is the risk of failure and of high repair costs, which extend the amortisation time. Accordingly, suitable surge protection should be used as protection against damage from lightning or surge voltages. Lightning strike with destruction through fire and surge voltages. Failure through surge voltages through induction and from the AC network. Wind, sun, snow and temperatures all place loads on the installation. Electrical devices of surge voltage category I, e.g. the electronic ballasts or LED drivers, must, according to VDE 0100-443.4 Table 1, be created with a surge voltage resistance of 1,500 volts and, in the case of surge voltage category II, of 2,500 volts. However, interference from lightning and switching operations cause surge voltages of up to several 10,000s of volts, which are considerably above the named rated surge voltage resistances. Modern LED luminaires require external surge protection against surge voltages. 3

Street lighting Chapter 2. Chapter 2.1 Street lighting Damage and repair costs In the field of street lighting, the replacement of the defective components, alongside the hardware costs, also incurs high costs through the use of elevating platforms and personnel. Upstream surge protection devices reduce the pulses and protect the luminaire. Whole streets are supplied via central distribution boxes, containing the controllers and protection components. The supply voltage is fed in via buried cables in the connection compartment of the mast. The luminaire is supplied from the connection compartment. Chapter 2.2 Creation of the earthing systems In a new installation, the supply cable can be protected against destruction from lightning currents in the earth by an optional earthing line above it. According to the current lightning protection standard DIN EN 62305-3 (German supplementary sheet 2), this earthing line must be located 0.5 metres above the supply cable. The earthing line compensates potential differences and minimises arcing to the supply cable. Image 1 shows the earthing line routed above the supply cable. Image 1: Routing of the earthing lines and the supply cables Legend: 1 Earthing line, uninsulated 2 Supply cable 4

Street lighting Chapter 2.3 Installation location of the lightning and surge protection The use of surge protection is required for safe operation. According to the American ANSI and IEEE standard, a surge voltage resistance of 20 kv is required for outdoor lighting at a surge current load of 10 ka. However, of decisive importance for the protection action is that the protection level of the surge protection device is below the surge voltage resistance of the lights and the LED driver. Surge protection devices must correspond to the testing standard EN 61643-11 and must be able to arrest surge currents of several thousand amps multiple times without destruction. According to the testing standard, each protection device requires thermal monitoring and must be isolated safely if there is a defect. In the luminaire standard "Fpr EN 60598-1: 2012-11 Luminaires Part 1: General Requirements and Tests", Point 4.32 specifies: "Surge protection devices must meet IEC 61643." If there is a direct lightning strike in the mast luminaire (Image 2), a large portion of the lightning current will flow directly into the earth, creating a potential difference to the supply cable. Powerful lightning current / combination arrestors can arrest the energy-rich currents. Image 2: Direct and close lightning strike Legend: 1 Lamp head with LED system, type 2 2 Connection compartment of the mast luminaire, type 1 + 2 3 Control cabinet with electronics, type 1 + 2 4 Earthing line, uninsulated 5 Supply cable Installation location Protection device Description Article no. 1 Lamp head Before the LED driver ÜSM-LED 230 Type 2 surge protection 5092 480 2 Mast Connection compartment V50 1+NPE-280 Type 1+2 combination arrestor 5093 522 3 Control cabinet Supply V50 3+NPE-280 Type 1+2 combination arrestor 5093 526 Table 1: Selection of the protection devices 5

Street lighting A lightning strike within 1.5 km generates a surge voltage which hits the lighting via the supply cable (Image 3). These surge voltages have less energy than the direct lightning strike, but can still destroy electronic components. Image 3: Remote strike and inductive coupling Legend: 1 Lamp head with LED system, type 2 or type 3 2 Connection compartment of the mast luminaire, type 2 3 Control cabinet with electronics, type 1 + 2 4 Earthing line, uninsulated 5 Supply cable Installation location Protection device Description Article no. 1 Lamp head Before the LED driver ÜSM-LED 230 Type 2 surge protection 5092 480 Alternatively: Type 3 protection 2 Mast ÜSM-A 230 Type 2 surge protection 5092 451 Connection compartment ÜSM-LED 230 Type 2 surge protection 5092 480 3 Control cabinet Supply, 3-phase V20 3+NPE-280 Type 2 surge protection 5095 253 Alternative: 1-phase V20 1+NPE-280 Type 2 surge protection 5095 251 Table 2: Selection of the protection devices Inductive couplings are considerably reduced through a metallic mast and a luminaire with a metallic housing. Here too, surge voltage pulses along cables from the supply network need to be considered. In this case, the surge protection in the mast connection compartment is easily accessible and easy to check. 6

Internal lighting Chapter 3. Internal lighting LED lighting systems in industrial plants and administrative buildings are usually destroyed by high voltages, coupled inductively or by switching operations. A risk analysis according to DIN EN 62305 can be used to determine whether an external lightning protection system is required or not. In a lightning protection system, the supply cables at the entrance to the building must be protected using suitable lightning current arrestors. Independently of this, the surge voltage protection should be installed for the entire lighting system. In industrial and sports halls, the luminaires are installed at a great height. After damage, the lights or the LED drivers can only be repaired at a high cost. As the minimum lighting strength required at the workstation can lead to accidents or errors, immediate action is required. The usually very long supply lines have a high potential for inductive coupling of surge voltages. Surge protection devices must be used in the subdistributor to be supplied. However, the luminaires are often 10 m from this distributor. To protect the LED drivers and the light, a protection device is then required directly in front of the electronic components. If the luminaires are, for example, mounted directly beneath the cable support systems, then the surge protection can also be inserted in a junction box in front of the luminaires. To use the shielding function of the metallic cable support systems, these must be included in the equipotential bonding on both sides. 7

Connection Chapter 4. Chapter 4.1 Connection The protection device ÜSM-LED 230 can be installed in series with or parallel to the luminaires. The differing connection can be used to maximise availability (parallel connection) or to switch off the luminaire if there is a defect on the protection device (serial connection). Parallel connection The surge protection device is located upstream of the LED luminaire. Failure behaviour: The display on the ÜSM-LED goes out. The surge protection is disconnected. The LED luminaire remains lit without protection. Chapter 4.2 Serial connection The surge protection is switched in series to the LED luminaire. Failure behaviour: The display on the ÜSM-LED goes out. The surge protection and the circuit (L') are disconnected. The failure is signalled by the luminaire going out. 8

Conclusion Chapter 5. Conclusion A suitable protection device upstream of the electronic LED drivers is a safe barrier against surge voltages. This guarantees the lifespan of the LED luminaires, securing the investment. In the commercial section and in the field of street lighting, with a long lifespan, enormous cost savings are possible, despite the increased procurement price. However, premature failure from surge voltage damage can push the return on investment back into the future. The investments can be protected through suitable protection measures. The OBO ProtectPlus range offers secure system solutions for lighting systems. 9

Literature index Chapter 6. Literature index Lightning protection: VDE 0185-305-1 (DIN EN 62305-1) - General principles VDE 0185-305-2 (DIN EN 62305-2) - Risk management VDE 0185-305-3 (DIN EN 62305-3) - Protection of buildings and humans DIN VDE 0185-305-4 (DIN EN 62305-4) Electrical and electronic systems within structures Earthing: DIN 18014: Foundation earther Low-voltage electrical installations: VDE 0100 (IEC 60634) VDE 0100-534 (IEC 60634-5-534) VDE 0100-410 (IEC 60634-4-41) VDE 0100-443 (IEC 60643-4-44) VDE 0100-714:2014-02 (IEC 60364-7-714) External lighting installations Luminaires: VDE 0711-1 (Fpr EN 60598-1) 10

Notes 11

OBO BETTERMANN GmbH & Co. KG PO Box 1120 58694 Menden Germany Customer Service Germany Tel.: +49 (0)2373 89-0 Fax: +49 (0)2373 89-1238 e-mail: export@obo.de www.obo-bettermann.com OBO BETTERMANN, OPTO 140102, Date 28 August 2014 EN, order no.: 9131942