PumpSmart Commissioning Process

Similar documents
ABB HVAC Drives ACH400 Vertical Electronic Bypass to ACH550 E-Bypass, 208V, 480V (R1... R4 Frame Size Drives)

NX Series Inverters. HVAC Pocket Programming Guide

ACS800. Firmware Manual ACS800 Standard Control Program 7.x

Installation and Start-up Guide. RS485 and RS232 Adapter for product type ACS 140

ACS800. Firmware Manual ACS800 Standard Control Program 7.x

VLT 6000 HVAC. Contents

ACS800. Master/Follower Application Guide Supplement to Firmware Manual for ACS800 Standard Application Program

ACS800. Firmware Manual ACS800 Pump Control Application Program 7.2 (+N687)

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

GPD 506/P5 Start-up Procedure and Checklist

FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3

ACH550 BCR/BDR/VCR/VDR E-Clipse Bypass Drives. User s Manual. ACH550 E-Clipse Bypass User s Manual 2-1

APPENDIX. SureSERVO QUICK START GUIDE. In This Appendix... Quick Start for SureServo Drives...A 2. Tuning Quick Start for SureServo Drives...

CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING

SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings

Softstarters. Type PST/PSTB Fieldbus communication CANopen for PST sw CU SFC132070M0201 February SFC132070M0201 1

Apéndice E Listado de constantes

vacon 100 hvac for indoor climate control

Specifying a Variable Frequency Drive s

Operational Overview and Controls Guide

VARIABLE FREQUENCY DRIVES Revised 4/30/ Mechanical Systems

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM

Phone: Fax: Web: info@clrwtr.com

Display Group Parameters

vacon 100 hvac premium ac drive for indoor climate control

Installation & Operation Manual for Energenics Air-Flow Optimizer

Phone: Fax: Web: info@clrwtr.com

Cat Electronic Technician 2015C v1.0 Product Status Report 2/20/2016 4:34 PM

S4000TH HART. HART Communication Manual

SAFETY INSTRUCTIONS WARNING

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Temperature Transmitter TTX300

SAFETY INSTRUCTIONS WARNING

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

Application Engineering

*.ppt 11/2/ :48 PM 1

SINAMICS BOP-2. Basic Operator Panel 2. Operating Instructions March 2010 SINAMICS

MANUAL FOR MODEL MP30 ELECTRIC MOTOR DRIVEN LIMITED SERVICE CONTROLLER

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

ACS 800. Supplement Traverse Control Application Program 7.x

ABB general machinery drives. User s manual ACS355 drives

Additional Benefits of VFDs In addition to energy savings and better process control, VFDs can provide other benefits:

SJ200 Series Inverter Quick Reference Guide

TABLE OF CONTENTS. Fig. 1 EV Pictorial Wiring Diagram 5. Section 2 Inverter Option Modules 6

Quick start: Panic Watch EU

Technical Information

Water-Source Heat Pump

Frequency Converter Fv

Centrifugal Fans and Pumps are sized to meet the maximum

Controller Automation, Model II+

MP-4000 Alarm List (Software version or later)

ABB machinery drives. User s manual ACS355 drives

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

A1000 Cheat Sheet (Open Loop Vector)

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Electronic Control Devices The European Product Catalogue 2007

7.6.4 Communication via BACnet MS/TP. Logical error. Maximum processing time, p2024[0] Process data monitoring time (setpoint timeout), p2040

GREISINGER electronic GmbH

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

PowerFlex 70 and 700 Packages for Fan and Pump Applications

Unidirectional Transmitter/ Receiver Units Introduction

NXL Series Inverters. HVAC Inverters made simple

BACnet Protocol Implementation Conformance Statement

T-100-R Installation Guide

CPW Current Programmed Winder. Application Handbook. Copyright 2002 by Eurotherm Drives, Inc.

1 Application Description Objective Goals... 3

SAFETY INSTRUCTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring.

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

Panorama. Softstarters The complete range

Installation and Maintenance manual. Softstarters PST / PSTB

ITC-308 Plug and Play Temperature Controller

SMM. Installation Operation Maintenance

Delta Temperature Controller User Manual

Brushless DC Motor Controller Product Specification Assembly 025F0129

ABB general purpose drives. Firmware manual ACS580 standard control program

TECHNICAL BROCHURE BAQUABII. * Available up to 100 GPM systems. Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

Fan Coil EC Motor Control

PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

Heating, air-conditioning, cooling

AC ADJUSTABLE SPEED DRIVES MICRO SERIES INVERTERS

CGC s Hybrid System Loop Control

Options for ABB drives, converters and inverters. User s manual FBIP-21 BACnet/IP adapter module

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Trouble Shooting Guide

City of Dallas 1.5 MGD WWTP

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

Commercial Refrigeration Temperature and Defrost Controls

Speed Control Relays SX2

Electronic, Digital and Mechanical Vibration Switches

B/S/H/ Error codes and service programmes PH

! WARNING. Before using product, read and understand instructions.

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

$SSOLFDWLRQ1RWH*; ³6LQJOHORRSRXWSXWV 6HULHV6&*(1 ', $2 3, $2

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Hydrate Occurrence in Centrifugal Compressor Systems

PARAGON ELECTRIC, INC. LIQUID LEVEL CONTROLLER USER MANUAL MODELS: LLC-I, LLC-II AND TELEMETRY OPTIONS

Transcription:

PumpSmart Commissioning Process 1. Complete the PumpSmart Warranty Registration form The warrantee registration is our method for determining if an installation has been commissioned properly and to identify how an application is configured Completion of the first page is mandatory for the extension of the warranty to 2 years Except for the shaded boxes, all sections must be completed Comments to first page: - Drive Configuration Code: This code may be found on the drive manufacturer nameplate Typical examples are: ACS800-U1-0050-4 (ABB ACS800 50 kva drive) ACH550-UH-023A-4 (ABB ACH550 15hp drive) - Installation Checklist: Refer to the configuration and installation manuals for acceptable qualities of these requirements. - Electrical Checks: All information, except meggar and operation mode, must be competed. Mega-Ohm meter checks are recommended when PumpSmart is being applied upon existing motors or if any drive faults occur during commissioning. The NOTES page is to be used for comments or exceptions that are not captured on the first page Space is included for sketching of the system. This is recommended, however not mandatory Completion of the parameter listing is recommended for later references and submittal to the customer. It is not necessary for PumpSmart certified personnel be present for the initial set-up/configuration of the drive. Inspection and completion of this registration is required within 20 days of initial start-up however 2. Fax or mail to PumpSmart Control Solutions within 20 days of initial start-up: PumpSmart Control Solutions Warranty Registration 240 Fall Street - Main Office Seneca Falls, NY 13148 Fax: 315 568 7145 Email: pumpsmart@ittcom (Subject Line: WARRANTY REGISTRATION) 3. Confirmation of warranty extension may be made by calling the PumpSmart Control Solutions applications group at (315) 568 4776.

MANDATORY PAGE Company Name Address L1 Address L2 City / State / Zip Contact Name Telephone Purchased From Sales Contact Telephone Product PS75 Drive Configuration Code ITT S/N Drive S/N S/W Version: Application: Application Macro Single Pump Process Speed Control Control Communication Discrete I/O - Analog I/O Profibus Modbus/Modbus + Other: Pump Information: Manufacturer: Control Mode (N/A Speed Control Macro) Pressure Flow Level Other Setpoint Control Keypad Analog Input Offset / Multivariable Control System Curve Compensation Protection Pump Protect Limit Torque Based Pump Protection Secondary Protection Protection Alarm Mode Alarm Only Alarm & Control Pump Wear Monitor Activated Not Used Model Number: Installation Checklist Check out of direct sunlight Check proper ambient temperature Check proper grounding Check cable connections Check free flow of cooling air Electrical Checks Motor Data HP FLA RPM VAC Check wire runs & conduit Check all mechanical connections Check I/O - Digital/Analog/Fieldbus Check motor rotation E-Stop/Permissive (DIIL - Jumper) Motor Cable Length Approx: Input Voltage @ base RPM Phase A-B Input Current @ base RPM Phase A Mega-Ohm Meter Reading Phase B-C Phase B Meggar type Phase C-A Phase C 500 V 1000 V Output Voltage @ base RPM Output Current @ base RPM Operation Mode Phase A-B Phase A DTC [Default] Scalar Phase B-C Phase B Phase C-A Phase C Additional Notes Attached (Optional) Parameter Listing Attached (Optional) Performed By Registration Number Customer Signature Date

NOTES PAGE Comments/Notes System Sketch Transmitters & Switches Pump Valves xx PT - Pressure FT - Flow LT - Level TT - Temperature PS - Pressure FS - Flow LS - Level TS - Temperature C - Centrifugal P - Positive Displacement ## - Number Stages Check Valve Valve

PARAMETER RECORDING PAGES PARAMETER DEFAULT CURRENT PARAMETER DEFAULT CURRENT 1001 EXT 1 COMMANDS 8=KEYPAD 1905 BEP_POWER 90% OF MOT NOM POWER 1002 EXT 1 COMMANDS 8=KEYPAD 1906 PWR_OFFSET 05HP / 00KW 1003 DIRECTION 1=FORWARD 1907 BEP_SPEED MOTOR NOM RPM 1004 MOTOR JOG DISABLED 1908 MIN_FLOW_CTL DISABLED 1103 SPD REF 1 SEL 0=KEYPAD 1909 MIN_FLOW_TRQ 0% 1104 SPD REF 1 MIN 0 1910 DRY_RUN_CTL DISABLED 1105 SPD REF 1 MAX MOTOR NOM SPD 1911 DRY_RUN_TRQ 0% 1106 REF 2 SELECT 19-PID 1 OUT 1912 RUNOUT_CTL DISABLED 1107 REF 2 MIN 0 1913 RUNOUT_TRQ 200% 1108 REF 2 MAX 100% 1914 RUNOUT_RAMP 20 SEC 1201 CONST SPEED SEL 9=DI3/DI4 1915 CALC_TEST_TRQ 1202 CONST SPEED 1 MIN SPEED 2001 MINIMUM SPEED 25% MOT NOM SPD 1203 CONST SPEED 2 MIN SPEED 2002 MAXIMUM SPEED MOT NOM SPD 1204 CONST SPEED 3 MIN SPEED 2102 STOP FUNCTION 1=COAST 1301 MINIMUM AI1 20% 2202 ACCELER TIME 1 5 SEC 1304 MINIMUM AI2 20% 2203 DECELER TIME 1 5 SEC 1401 RELAY OUTPUT 1 1=READY 2501 CRIT SPEED SEL 0=OFF 1402 RELAY OUTPUT 2 2=RUN 2502 CRIT SPEED 1 LO 0 1403 RELAY OUTPUT 3 4=FAULT 2503 CRIT SPEED 1 HI 0 1501 AO1 CONFIG 0102 SPEED 2504 CRIT SPEED 2 LO 0 1507 AO2 CONFIG 0104 CURRENT 2505 CRIT SPEED 2 HI 0 1601 RUN ENABLE 0=NOT SEL 3001 SENSOR FAILURE 3=LAST SPEED 1602 PARAMETER LOCK 1=OPEN 3002 KEYPAD FAILURE 3=LAST SPEED 1603 PASSCODE 358 3003 SECONDARY PROT A 0=NOT SEL 1606 LOCAL LOCK 0=NOT SEL 3004 SECONDARY PROT B 0=NOT SEL 1607 PARAM SAVE 0=DONE 3101 ERROR RESET 0 1608 START ENABLE 1 0=NOT SEL 3103 RESET DELAY 60 SEC 1901 CONFIG_SPD_MIN SPD=0 3301 PS75 VERSION 1902 PUMP_PROTECT DISABLED 3302 LP VERSION 1903 PROTECT_LIMIT 97% 3303 TEST DATE 1904 PROTECT_DELAY 0 SEC 3304 DRIVE RATING NOTE Not all parameters may be visible PumpSmart disables parameter groups that are not applicable to the selected operating mode/macro (1) Assumes a flowmeter with full scale range of 0-300 GPM (2) Assumes suction side pressure gauge with full scale range of 0-300 PSIA

PARAMETER DEFAULT CURRENT PARAMETER DEFAULT CURRENT 3401 SIGNAL 1 PARAM SPD(RPM) 4023 PID SLEEP SPEED 0 3408 SIGNAL 2 PARAM EXT SPD REF 4024 PID SLEEP DELAY 2 SEC 3415 SIGNAL 3 PARAM CURRENT 4025 WAKE UP DEV 0 4001 GAIN 1.0 / 25 4026 WAKE-UP DELAY 0.5 SEC 4002 INTEGRATION TIME 0.7 / 150 SEC 9901 LANGUAGE 1=ENG (AM) 4005 REGULATION MODE 0=NORMAL 9905 MOTOR NOM VOLT 4006 UNITS 4=% 9906 MOTOR FL CURR 4008 0% PV SCALE 0 9907 MOTOR NOM FREQ 4009 100% PV SCALE 100 9908 MOTOR NOM SPEED 4010 SETPOINT SEL 0=KEYPAD 9909 MOTOR NOM POWER 4022 SLEEP SELECTION 0=NOT SEL