Medical Imaging Equipment Maintenance Checklist

Similar documents
REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS

Name: Date: Team: Lab Experiment # 3. Focused Grid Positioning Errors. Computed Radiography and Direct Digital Radiography

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

Workspace and storage furnishings

Compliance Guidance for FLUOROSCOPIC QUALITY CONTROL

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

KS-70. Catheterization Table GENERAL

CLINICAL PERFORMANCE OBJECTIVES

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

Global Water Instrumentation, Inc.

EPEX. The Hologic EPEX General. Direct-to-Digital System for General Radiography. Versatility for a complete range of general radiographic exams

Replacing N-300 PCB YZ Systems for use by YZ s distribution network and end-users.

Evaluate, Clean, and Tune Guidance

TOYOTA Tundra BACK-UP CAMERA SYSTEM Preparation

PREVENTATIVE MAINTENANCE

12. Inspection and Maintenance

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT

Owner s Manual Gantry Cranes

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

AU-110 racking guide NBXPN: 023

QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES. (a) Applicability. (b) Definitions

Oregon Fuel Injection

Installation instructions, accessories - Handsfree for cellular phone, system B, entry level

Raritan LCD KVM Console (T1700/T1900)

American College of Radiology Mammography Accreditation Program

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

H Service Data Sheet 1 of 8

Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery

CEILING CASSETTE FAN COIL UNIT

Raritan LCD KVM Console (T1700/T1900)

Digital vs. Analogue Control Systems

MAINTENANCE & TROUBLESHOOTING

PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X

Quality Control and Maintenance Programs

Create a premium DR room like no other

2740 Whitten Rd Bldg 103 Memphis, TN Telephone

Catherine LeCocq, Robert Ruland. February, 2008

QUALITY ASSURANCE IN DENTAL RADIOGRAPHY. Part of the Ionising Radiation Regulations Section 4 (3) IR(ME)R 2000

AstroSystems Digital Setting Circles for Zhumell, GSO, Apertura and Astro-Tech

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids

X-ray Imaging Systems

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Stereoscopic 3D Digital Theater System. Operator Manual (MI-2100)

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

39HQ Airovision Air Handling Units

QUALITY CONTROL RECOMMENDATIONS FOR DIAGNOSTIC RADIOGRAPHY VOLUME 3 RADIOGRAPHIC OR FLUOROSCOPIC MACHINES

Gas Oven Repair Guide

Daily Operator Checks. Monthly Maintenance

SCION tc COIL OVER SUSPENSION Preparation

INTRODUCTION. A. Purpose

FPU SYSTEMS OPERATION MANUAL BOH OFFICE MODULE (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH FPU Field Pack/up Units CHAPTER 5

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Ch. 227 ANALYTICAL X-RAY EQUIPMENT 25

Maintenance Report MEDIUM VOLTAGE POWER STATION 500SC / 630SC / 800SC / 900SC / SC / SC / 1250SC / 1600SC / 1800SC / 2000SC

Back-Up Camera Installation Guide

Laboratory Construction Guidelines Vicon MX Systems

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

HYDRAULIC LIFT TABLE CART 2200-LB.

Installing the Broadband Global Area Network (BGAN) Fixed Mount Kit

Basics to Using the View Camera

HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate

Fading Red Tones on Color LaserJet 2600s

Oil and Coolant Circulating Heating System. Model - OCSM

Hard Disk Drive (HDD)

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abu Bakar School of Medical Imaging KLMUC

QUALITY CONTROL IN DIAGNOSTIC RADIOLOGY

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

4RU High Density Shelf Installation Instructions

DirectCommand Installation DirectCommand 3-Channel Spreader Kit

Understanding Digital Modalities: System Integration and Use

Subminiature Load Cell Model 8417

Operating Instructions Drill rig DRU160

W850. Maintenance Guide

16. APTA PR-IM-S Standard for Pantograph Current Collection Equipment Periodic Inspection and Maintenance

Installation Manual on Continuous ink supply system (CISS) For printer EPSON C82/C80/C70

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Compliance Guidance for QUALITY ASSURANCE MANUAL (2 nd Edition)

1000-LB. TRAILER JACK OWNER S MANUAL

1 HP Ersatzteile für DesignJet 5500

Special Products Sistemleri. Yedek Parça Fiyat Listesi

Dental Radiography collimator Ionising radiation image radiolucent area radiopaque area controlled zone scatter radiation intraoral

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis

Hardware and Software Upgrade for the Solution Measurement and Monitor System at Rokkasho Reprocessing

Quality Assurance Calendar Maintenance Responsible Party Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

StructureScan Installation

ROTOR LOADER OWNER S MANUAL

TONER CARTRIDGE REMANUFACTURING INSTRUCTIONS DELL 3110 CN TONER CARTRIDGE

About the BitStorm 6051 POTS Splitter

DVD-60C The Seven Sins of Wire Harness Assembly

Weatherproof Extension Case (Part # S-EXT-CASE)

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Tool And Material Checklist

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4

Submersion/Insertion Toroidal Sensor

Transcription:

Medical Imaging Equipment Maintenance Checklist The Contractor shall complete the following maintenance checklist during each scheduled preventive maintenance inspection in addition to any other requirements recommended by the manufacturers specifications (reference service manual for proprietary maintenance). Service shall be applicable to equipment as follows: GENERAL RADIOGRAPHY SYSTEM - GENERATOR Open and clean the interior of the control console Reassemble the cover; check the control panel operation Vacuum the power cabinets of dust and dirt Check the integrity of the power relays and contactors Inspect any wire rope for breaks and frays GENERAL RADIOGRAPHY SYSTEM TABLE & BUCKY Check the general conditions of the unit Remove the access cover and clean the interior Check all locks for proper function/operation Check mechanical condition of the bucky and tray Clean the unit of any dirt and dust Perform complete operational check after reassemble GENERAL RADIOGRAPHY SYSTEM TUBE SUSPENSION Check the transverse and horizontal movement Check for excessive bearing noise or vibration Check vertical movement and angulations Insure the cables allow for maximum tube movement Inspect the tube support cable for breaks and frays Check all locks for proper function/operation GENERAL RADIOGRAPHY SYSTEM TUBE & COLLIMATOR

Check and tighten loose hardware, handles and screws Check the electrical cable and connectors for damage Inspect the collimator for complete operational ease Insure the collimator cross-hairs align with shutters The S.I.D. indicator must be functional and accurate Check that angle indicator displays correct angles Is the indicated field aligned to the light field Check light field to x-ray field alignment Is the PBL or auto-collimator connected Yes No If yes, check for accuracy Perform an overall operational check and a tube warm-up GENERAL RADIOGRAPHY SYSTEM AEC CONTROLS Check upright bucky chambers for timing consistency Check table bucky chambers for timing consistency GENERAL RADIOGRAPHY SYSTEM UPRIGHT BUCKY The vertical movement should be free and with ease Check all of the locks and adjust as required Check the electrical cable and connectors for damage Check the cassette holder and tray for proper operation Perform a complete operational check of unit GENERAL RADIOGRAPHY SYSTEM - CONTROL PANEL Clean and check the integrity of the console modules Open the hinged cover and clean the interior GENERAL RADIOGRAPHY SYSTEM - TOMOGRAPHY COMPONENT

Assemble and check the mechanical attachment apparatus Check and tighten loose hardware, handles and screws Inspect any wire rope for breaks or frays Perform a complete operational check of the unit Is the drive smooth and free of vibration? FLUOROSCOPY GENERATOR & TUBE FLUOROSCOPY TOWER - IMAGE INTENSIFIER & CAMERA Check the integrity all Image Intensifier and camera components Perform a complete operational check of the unit PORTABLE XRAY UNITS Vacuum the unit for dust and dirt

PORTABLE C-ARM UNITS Ensure proper performance of camera and monitors Check performance of peripheral devices (printers, etc) MAMMOGRAPHY UNIT GENERATOR Reassemble cover; check the control panel operation MAMMOGRAPHY UNIT COMPRESSION DEVICE Inspect the integrity of the hardware The vertical movement should be free and with ease Perform a complete operational check of compression device MAMMOGRAPHY UNIT CONTROL PANEL Clean and check the integrity of the console modules MAMMOGRAPHY UNIT GRID AND BUCKY

Inspect the integrity of the hardware The movement should be free and with ease Check all of the locks and adjust as required Perform a complete operational check of grid and bucky MAMMOGRAPHY UNIT TUBE AND COLLIMATOR Check and tighten loose hardware, handles and screws Check the electrical cable and connectors for damage Inspect the collimator for complete operational ease Insure the collimator cross-hairs align with shutters Insure that cables allow for maximum tube movement The S.I.D. indicator must be functional and accurate Is the indicated field aligned to the light field Check light field to x-ray field alignment Perform tube with warm-up as indicated in the OEM Service Manual ULTRASOUND UNITS & PRINTERS Check performance of peripheral devices (printers, etc) DIRECT RADIOGRAPHY (DR) UNITS Check integrity of all hardware and moving parts

Check the QA workstation to ensure normal functionality Perform a complete operational check according to the service manual DARK ROOM FILM PROCESSORS Medical Imaging Film Processors replace any parts for optimal performance Inspect and clean all deep (developer/fixer/rinse) roller assembly Inspect and clean all crossover racks, gears, and rollers Conduct complete inspection and cleaning of chemical tanks Refresh chemicals and all filters as necessary Confirm proper replenishment Confirm appropriate developer and dryer temperatures Perform QC testing with sensitometric strip for proper calibration