E2600 DSA E-Series iscsi Disk Arrays. en Quick Install Guide



Similar documents
DE1600 DSA E-Series iscsi Disk Arrays. en Quick Install Guide

DSA E-Series E2600, DE1600, DE6600. en Storage System Site Preparation Guide

DE1600 DSA E-Series iscsi Disk Arrays. Installation Manual

NetApp EF550 Flash Array

NetApp E-Series Storage Systems

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide

Upgrading or Replacing a Host Interface Card in a Xanadu-230 Controller-Drive Tray

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Fiber Optic Ethernet Media Converter Kit

1200/1400 Series as standard iscsi disk array. Quick Installation Guide

Bosch Video Management System High availability with VMware

HP UPS R1500 Generation 3

VMware for Bosch VMS. en Software Manual

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

About the HotWire Slot Standalone Shelf

Rack Installation Instructions

HP StorageWorks 8Gb Simple SAN Connection Kit quick start instructions

SANtricity Storage Manager 11.25

Bosch Video Management System High Availability with Hyper-V

HP Port Switches Quick Setup Guide

Getting Started Guide Cisco Content Delivery Networking Products

How to Set Up Your NSM4000 Appliance

Installation. Basic Rack Power Distribution Unit for Blade Servers

About the BitStorm 6051 POTS Splitter

IBM System Storage. N3300 Installation and Setup Instructions

Refer installation of power supplies to qualified service personnel.

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

BX7000 Multi-Access Gateway Getting Started Guide

Rack installation instructions

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

PS6500 Storage Arrays Rack Mount Instructions

Cisco CWDM GBIC and CWDM SFP Installation Note

Acano solution. Acano Solution Installation Guide. Acano. January B

Removing memory and option cards

P Quick Start Guide. VoIP Analog Telephone Adaptor DEFAULT LOGIN. IP Address Password Version /2007 Edition 1

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

LIEBERT VNSA Installation Sheet

MX5, MX10, MX40, and MX80 3D Universal Edge Router Quick Start

Quick Setup Guide. Tandberg Data DPS1000 Series Model: DPS1100 and DPS1200, Release: 1.3

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide

BRACKET LOCKING SCREW

MCR1900 Media Converter 19-Slot Chassis

Wall-Mounting your HP computer. User Guide

The power module is Feature Number 8800-F2-901.

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

ASKING FOR ASSISTANCE

INSTALLATION INSTRUCTIONS

Setting Up the ZigBee Ethernet Gateway

StorTrends 3400 Hardware Guide for Onsite Support

Replacing the Gateway M675 Keyboard

Service Guide. Gateway M275

A QUICK AND EASY GUIDE TO SETTING UP THE DELL POWEREDGE C8000

Rack Installation Instructions

SANtricity Storage Manager 11.20

HP R12000 and R18000 DirectFlow UPS User Guide

DCF Optimized Rack System

SANtricity ES Storage Manager V Initial Configuration and Software Installation

Contractors Guide Central Inverter System Installation

Quick Start Guide. RV0xx Series Routers

HP Integrity rx2660 Server Installation Guide

3.5 EXTERNAL NETWORK HDD. User s Manual

RSA Security Analytics. S4 Broker Setup Guide

VG4 Fiber Optic Media Converter

HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

Installation Instructions

INSTRUCTIONS: LocknCharge Laptop Carts

Connecting to the Switch

Installing Your 960 or 980 Server into a Rackmount Cabinet

Cabinets 101: Configuring A Network Or Server Cabinet

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

NetApp E-Series Storage Systems

Thank for choosing the Dominion KX III, the industry's highest performance enterprise-class, secure, digital KVM (Keyboard, Video, Mouse) switch.

DIVAR IP U DIP N, DIP HD, DIP HD. en Quick Installation Guide

RM410. Hardware Installation Guide. Quick Start Guide. Rack Mounting Kit. Version 1.00 Edition 1, 12/2012

Adding or replacing a mesh node in an existing mesh network

UPGRADING AND SERVICING GUIDE

connecdim Gateway G1 Ethernet TCP/IP to DALI

HP SATA/SAS hard drive and Solid State Drive installation

Installation Guide Solar Connect-11

Installation Instructions

Using a Fabric Extender with a Cisco Nexus 5000 Series Switch

Bosch Video Management System. VIDOS to Bosch VMS Migration Guide

Quick Start Guide. WAP371 Wireless AC/N Dual Radio Access Point with Single Point Setup Quick Start Guide. Cisco Small Business

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Moxa EtherDevice Switch

HP 16/18-Port Cable Management Kit Installation Guide

Energy Communication Unit (ECU)

Secure your IT equipment with confidence... secure with NetClosure

RC8021 Indoor Camera Installation Guide

DD670, DD860, and DD890 Hardware Overview

FUSION R400 RAID USB 3.0

DIVAR IP 2000 DIP N, DIP HD, DIP HD. en Installation Manual

Job Aid Pre-Installation Information S8500 Media Server

Raritan LCD KVM Console (T1700/T1900)

NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series. Quick Install Guide

Transcription:

E2600 DSA E-Series iscsi Disk Arrays en Quick Install Guide

E2600 DSA E-Series iscsi Disk Arrays Table of Contents en 3 Table of contents 1 Before you begin 4 1.1 Learn about management methods 4 1.2 What you need for assembly 4 2 Device view 6 3 Install the mounting rails 7 4 Install the controller-drive tray 8 5 Secure the controller-drive tray 9 6 Connect the cables 10 7 Turn on the DC power 13 8 Turn on the AC power 15 9 Install and configure the storage array 16 Bosch Sicherheitssysteme GmbH Quick Install Guide 07/2012 V1

4 en Before you begin E2600 DSA E-Series iscsi Disk Arrays 1 1.1 Before you begin For warnings and detailed installation instructions, refer to the E2600 DSA E-Series Installation manual and additional documentation in the Online Product Catalog on http:// www.boschsecurity.com > Video > Digital Recording and Storage > Disk Arrays (Network Attached) > DSA Disk Arrays > DSA E-Series iscsi Disk Arrays. (The navigation path is subject to change). Management methods are specific to the installation steps in Section 6 and Section 9. Learn about management methods In-band management Management using the I/O connections between the host and the storage. The host must still have Ethernet capabilities. Access volume Used to communicate management requests and event information. An access volume is needed for only in-band management. Out-of-band management Management directly through the Ethernet connections on each controller using one of the network configurations from the following list (the command line interface CLI might be required): DHCP server Permits nodes to dynamically acquire network addresses. Ethernet IP address Permits direct connection to controller A or controller B by using an IP address in the form of xxx.xxx.xxx.yyy and xxx.xxx.xxx.yyz. Static IP address Recommended for out-of-band management using IPv4 networks. Router advertisements Recommended for out-of-band management using IPv6 networks. MAC address Associates the media address control (MAC) address (xx:xx:xx:xx:xx:xx) of each controller with an assigned IP address. 1.2 What you need for assembly E2600 controller-drive tray ship group One two-unit (2U) -high E2600 controller-drive tray Two power cords One cabinet mounting hardware kit, including: Two mounting rails (right and left assemblies) Eight M5 x 8 mm screws Use six screws to secure the mounting rails and two screws to secure the front of the controller-drive tray to the cabinet. Two M4 x 8 mm screws Use the screws to secure the rear of the controller-drive tray to the mounting rails. Options Drives (two minimum for each controller-drive tray) DC power cords for the optional 48 VDC power option If you have any questions about the firmware or your configuration, contact your Customer and Technical Support representative. Tools An Internet connection 07/2012 V1 Quick Install Guide Bosch Sicherheitssysteme GmbH

E2600 DSA E-Series iscsi Disk Arrays Before you begin en 5 A cart to hold the controller-drive tray and its components Labels for the cable connections A medium flat-blade screwdriver A No. 2 Phillips screwdriver Anti-static protection A flashlight Bosch Sicherheitssysteme GmbH Quick Install Guide 07/2012 V1

6 en Device view E2600 DSA E-Series iscsi Disk Arrays 2 Device view Controller-Drive Tray (12 Drives) Front View 1 2 3 4 5 6! Figure 2.1: Front View E2600 1 Standby Power LED 4 Service Action Required LED 2 Power LED 5 Locate LED 3 Over-Temperature LED 6 Drive Canister Controller-Drive Tray Rear View 1 2 Figure 2.2: Rear View E2600 1 Controller Canister 2 Power-Fan Canister 07/2012 V1 Quick Install Guide Bosch Sicherheitssysteme GmbH

E2600 DSA E-Series iscsi Disk Arrays Install the mounting rails en 7 3 Install the mounting rails You can install the drive tray into an industry-standard cabinet. There must be a minimum depth of 76 cm (30 in.) between the front EIA support rails and the rear EIA support rails. 1. Position the mounting rails in the cabinet. If you are installing the mounting rails above an existing tray, position the mounting rails directly above the tray. If you are installing the mounting rails below an existing tray, allow 8.9-cm (3.5-in.) vertical clearance for the controller-drive tray. 2. Starting with the left mounting rail, use a flat-blade screwdriver to loosen the two flathead rail adjustment screws. Hold the front of the left mounting rail against the inside of the front cabinet-mounting flange, and then extend the rear of the mounting rail until it makes contact with the rear cabinet-mounting flange. The alignment pins at the rear of the mounting rail should slide into the holes at the rear of the cabinet. 1 1 2 4 3 Figure 3.1: Mounting Rails 1 Mounting Holes on the Industry-Standard Cabinet 2 Adjustment Screws for Locking the Length of the Mounting Rail 3 Mounting Rail 4 Clip for Securing the Rear of the Controller-Drive Tray 3. From the front of the cabinet, with the mounting-rail flanges inside of the cabinet s mounting rail assemblies, use the Phillips screwdriver to loosely tighten only the lower screw. 4. From the rear of the cabinet, use the Phillips screwdriver to loosely tighten the two screws. Do not completely tighten the screws until you have installed the controller-drive tray in the cabinet. 5. Repeat step 1 through step 4 for the right mounting rail. 6. Tighten the fl at-head rail adjustment screws on both mounting rails. Bosch Sicherheitssysteme GmbH Quick Install Guide 07/2012 V1

8 en Install the controller-drive tray E2600 DSA E-Series iscsi Disk Arrays 4 Install the controller-drive tray Warning! Risk of bodily injury!, Two persons are required to safely lift the component. 1. With the help of one other person, remove the controller-drive tray from the shipping box. 2. With the help of one other person, slide the rear of the controller-drive tray onto the mounting rails so that the mounting holes on the front flanges of the controller-drive tray align with the mounting holes on the front of the mounting rails. 07/2012 V1 Quick Install Guide Bosch Sicherheitssysteme GmbH

E2600 DSA E-Series iscsi Disk Arrays Secure the controller-drive tray en 9 5 Secure the controller-drive tray! Warning! Risk of bodily injury Do not use equipment in the cabinet as a shelf or work space. 1. Secure the screws in the top mounting holes and the bottom mounting holes on each side of the controller-drive tray. 2 1 2 Figure 5.1: Controller-Drive Tray (12 Drives) 1 Mounting Holes 2 Screws 2. Secure the rear of the controller-drive tray to the cabinet by using two screws to attach the flanges on each side at the rear of the controller-drive tray to the mounting rails. 3. Install the front end caps on the front of the controller-drive tray by pressing the front end caps into place on the left side and the right side. Note: You will install the DE1600 drive trays below and above the controller-drive tray, keeping the weight in the lower portion of the cabinet. You can install a maximum of 192 drives, including the 12 drives in the E2600 controller-drive tray. If needed, refer to E2600 Controller-Drive Tray Installation manual. 1 Bosch Sicherheitssysteme GmbH Quick Install Guide 07/2012 V1

10 en Connect the cables E2600 DSA E-Series iscsi Disk Arrays 6 Connect the cables! Warning! Risk of exposure to laser radiation Do not disassemble or remove any part of a Small Form-factor Pluggable (SFP) transceiver because you might be exposed to laser radiation. In this step, you will connect the E2600 controller-drive tray to the host or hosts, and then you will connect the DE1600 drive tray to either a E2600 controller-drive tray (which contains the controllers), or to another DE1600 drive tray in the storage array. For more information, refer to these documents: DE1600 Drive Tray Quick Install Guide E2600 Installation manual You can find the E2600 Controller-Drive Tray Installation manual and additional documentation in the Online Product Catalog on http://www.boschsecurity.com > Video > Digital Recording and Storage > Disk Arrays (Network Attached) > DSA Disk Arrays > DSA E-Series iscsi Disk Arrays. (The navigation path is subject to change). Host-to-Controller Cabling 1. Attach the appropriate cables and components for the relevant protocol (Fibre Channel, SAS, or Ethernet). 2. Choose the host connection configuration (examples follow). Direct topology Connect the cable from the host port on the controller to either an HBA port, a SAS port, a host channel adapter (HCA) Fibre Channel port, or an Ethernet adapter (iscsi) on the host. The fi gures on the next page all show the HBA port option on the host. Switch or fabric topology Connect the cable from the host port on the controller to a port on the switch, and make sure that the HBA and the controller are in the same zone on the switch. Mixed topology Use a combination of direct topology and fabric topology. 3. Repeat step 1 through step 2 for each controller and host channel that you intend to use. 4. When you are finished, label each end of the cable with information about its connection. Direct Topology Two Hosts and a Dual Controller-Drive Tray for Maximum Redundancy (For more examples of a switch or fabric topology or of a mixed topology, refer to E2600 Installation manual) 07/2012 V1 Quick Install Guide Bosch Sicherheitssysteme GmbH

E2600 DSA E-Series iscsi Disk Arrays Connect the cables en 11 1 1 2 3 2 3 4 5 4 5 6 7 5. Cable the drive trays as needed. For maximum redundancy and tray loss protection, see the following figure. Refer to Hardware Cabling for detailed information. Note: The number of drive trays may vary as long as the maximum number of drives is not exceeded. You can connect a combination of drive trays for a maximum of 192 drives, including the 12 drives in the E2600 controller-drive tray. Bosch Sicherheitssysteme GmbH Quick Install Guide 07/2012 V1

12 en Connect the cables E2600 DSA E-Series iscsi Disk Arrays Contr Chamonix oller A A Exp Contr Chamonix oller B B Exp SAS IN SAS IN SAS EXP SAS IN SAS IN SAS EXP ESM A ESM B 1A 1B 2A 2B SAS IN SAS IN SAS EXP SAS IN SAS IN SAS EXP ESM A ESM B 1A 1B 2A 2B SAS IN SAS IN SAS EXP SAS IN SAS IN SAS EXP ESM A ESM B 1A 1B 2A 2B SAS IN SAS IN SAS EXP SAS IN SAS IN SAS EXP ESM A ESM B 1A 1B 2A 2B SAS IN SAS IN SAS EXP SAS IN SAS IN SAS EXP ESM A ESM B 1A 1B 2A 2B SAS IN SAS IN SAS EXP SAS IN SAS IN SAS EXP ESM A ESM B 1A 1B 2A 2B SAS IN SAS IN SAS EXP SAS IN SAS IN SAS EXP ESM A ESM B 1A 1B 2A 2B Steps to connect Ethernet cables for out-of-band management only 1. Connect one end of the Ethernet cable to the Ethernet port 1 connector on controller A. 2. Connect the other end of the Ethernet cable to the appropriate Ethernet network connection or directly to your Ethernet ports on your management station. 3. Repeat step 1 through step 2 for controller B. 07/2012 V1 Quick Install Guide Bosch Sicherheitssysteme GmbH

E2600 DSA E-Series iscsi Disk Arrays Turn on the DC power en 13 7 Turn on the DC power i! Notice! DC power is an option that is available for use with your E2600 controller-drive tray and drive trays. If you choose to have 48 VDC power available, you need a qualified service person to install the equipment that provides special DC power connectors to each power-fan canister in your storage array. Warning! Risk of bodily injury A qualified service person is required to make the DC power connection according to NEC and CEC guidelines.! Warning! Risk of electrical shock This unit has more than one power source. To remove all power from the unit, all DC MAINS must be disconnected by removing all power connectors (item 4 below) from the power supplies. + 1-2 3 4 Figure 7.1: Power cable 1 Supply (Negative), Brown Wire, 48 VDC 3 Ground, Green/Yellow Wire 2 Return (Positive), Blue Wire 4 DC Power Connector! Warning! Risk of bodily injury Each tray has more than one power cord. To remove all electrical current from the devices, make sure that all of the power cords are disconnected from the power source and that the two-pole 20-amp circuit breaker for the storage array has been disconnected. Bosch Sicherheitssysteme GmbH Quick Install Guide 07/2012 V1

14 en Turn on the DC power E2600 DSA E-Series iscsi Disk Arrays 2 1 You must follow the power sequence in the order shown. To establish power redundancy for trays with two power supplies, use a separate power source for each power-fan canister. For additional redundancy, you can connect each DC power connector on the same power-fan canister to a different power source. i Notice! You must turn on the power to all connected drive trays before you turn on the power to the E2600 controller-drive tray. Performing this action makes sure that the controllers recognize each attached drive tray. 1. Disconnect the two-pole 20-amp circuit breaker for the storage array 2. Make sure that all of the DC Power switches on the DC-powered controller-drive tray and the DC-powered drive trays are turned off. 3. Connect the DC power connector cables to the DC power connectors on the rear of the controller-drive tray and the drive trays. 4. Have a qualifi ed service person connect the other end of the DC power connector cables to the DC power plant equipment. 5. Turn on the Power switch on each power-fan canister in all of the drive trays. 6. Turn on the Power switch on each power-fan canister in the controller-drive tray. Note: When turning off the power to the storage array, perform the procedure in the reverse order. Turn off the power first to the controller-drive tray, and then turn off the power to the drive trays. 07/2012 V1 Quick Install Guide Bosch Sicherheitssysteme GmbH

E2600 DSA E-Series iscsi Disk Arrays Turn on the AC power en 15 8 Turn on the AC power 2 1 You must follow the power sequence in the order shown for turning on AC power to controller-drive trays and drive trays that use AC power. To establish power redundancy for trays with two power supplies, use at least two different power distribution units (PDUs) in the cabinet. Split the power connections from each tray into the separate PDUs. Then connect the PDUs to external power receptacles that are on different circuits.! Warning! Risk of bodily injury Each tray has more than one power cord. To remove all electrical current from the devices, make sure that all of the power cords are disconnected from the power source. i Notice! You must turn on the power to all connected drive trays before you turn on the power to the E2600 controller-drive tray. Performing this action makes sure that the controllers recognize each attached drive tray. 1. Turn off all of the Power switches from the rear of the storage array, and make sure that all of the power cords are connected. 2. If the main AC circuit breaker switches in the cabinet are not already turned on, turn on the circuit breaker switches. 3. Turn on the Power switch on each power-fan canister in all of the installed drive trays. 4. Turn on the Power switches on each power-fan canister in the E2600 controller-drive tray. Note: When turning off the power to the storage array, perform the procedure in the reverse order. Turn off the power fi rst to the controller-drive tray, and then turn off the power to the drive trays. Bosch Sicherheitssysteme GmbH Quick Install Guide 07/2012 V1

16 en Install and configure the storage array E2600 DSA E-Series iscsi Disk Arrays 9 Install and configure the storage array For the basic setup use the VRM Configuration Manager software. For detailed information refer to the Configuration Manager operating manual. For advanced features refer to the SANtricity configuration and installation manual. All necessary documentation can be found in the Online Product Catalog on http:// www.boschsecurity.com > Video > Digital Recording and Storage > Disk Arrays (Network Attached) > DSA Disk Arrays > DSA E-Series iscsi Disk Arrays. (The navigation path is subject to change). 07/2012 V1 Quick Install Guide Bosch Sicherheitssysteme GmbH

Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com Bosch Sicherheitssysteme GmbH, 2012