Standard Steel Doors and Frames. Modular Masonry Construction

Similar documents
Test Procedure and Acceptance Criteria for Factory Applied Finish Coatings for Steel Doors and Frames

Fact File. Compilation of SDI Technical Documents and ANSI/SDI Standards and Test Methods. Updated August 2016

Standard Steel Doors, Frames, Accessories and Related Components

Installation Troubleshooting Guide for Standard Steel Doors and Frames STEEL DOOR INSTITUTE DETROIT ROAD CLEVELAND, OHIO S D I

Doors and frames. Technical data manual 2015 rev. 8/17/15

Steel Door Institute. Fire Rated Doors and Frames

Dimensioning and Estimating Brick Masonry

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

n Three 4 x 4 butt hinges per door - prevents wracking and assures smooth positive operation n Heavy duty 16 gauge steel frame

Steel Door Frame Installation in Steel Stud Construction

Construction Masonry - Brick

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.

Repair and Remodeling Estimating Methods. 4th Edition. RSMeans

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

HARDWARE LOCATIONS FOR HOLLOW METAL DOORS AND FRAMES

PART 1 GENERAL 1.1 SECTION INCLUDES

ST. MONICA FOOD PANTRY HOUSTON, TEXAS

Technical Data Honeycomb Door Leaf

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

ANSI A250.4 Test Procedure and Acceptance Criteria for Physical Endurance for Steel Doors, Frames and Frame Anchors

Specifications for Standard Steel Doors and Frames (SDI-100)

Design Development Quality Management Phase Checklist Project Phase Checklist Series

LAYING BLOCK AND BRICK

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

ADVANTAGES OF MODULAR LAYOUT

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10

Cost Comparisons for Common Commercial Wall Systems

SECTION TABLE OF CONTENTS. H Proposed Material, Product or Equipment Substitution Request

SAMPLE SCHEDULE OF VALUES APPLICATION & CERTIFICATE FOR PAYMENT

INSTALLATION INSTRUCTIONS

Basic Fire Door Requirements

GUIDELINES FOR REHABILITATION OF TRADITIONAL COMMERCIAL BUILDINGS DESIGN GUIDELINES

REDI-EXIT COMMERCIAL FIRE DOOR AND EXTERIOR DOOR KITS INSTALLATION GUIDELINES

Quality Building Products for over 50 Years

Automatic Door Selection Guide

280+ Mortise Mounted Series Shear Locks Special Application Solution

PUBLIC RESTROOMS, DESIGN INTENT

1. Concrete: T W L / 27 = Concrete C.Y. Multiply Feet Thickness x Feet Width x Feet Length / 27 = Cubic Yards.

Certification: Building Plans Examiner. Exam ID: B3

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

Fire-rated Aluminum Doors

This directive establishes Department of Homeland Security (DHS) policy regarding the physical protection of facilities and real property.

Architectural hardware consulting services

Sub-Bid Contractor Update Statement. Tab A - Invitation for Bids. Tab B - Instructions to Bidders

Classroom Door Security & Locking Hardware

Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art

Eaton Customer Manufacturing Solution Centers (CMSC) Solutions for every industry

DOORS HOLLOW METAL MANUAL NAAMM STANDARD NAAMM HMMA METAL DOORS & FRAMES METAL. A Division of

Installation S D I TECHNICAL DATA SERIES. and Troubleshooting Guide. for Standard Steel Doors and Frames STEEL DOOR INSTITUTE

HOW TO ESTIMATE THE COST OF T-BAR

A Complete Solution CREATING WALLS THAT DEFINE SPACE

How To Find Out What Happened To Slave Housing

Security steel door dw 52-1 Teckentrup DF WK 2 optionally with glazing/ventilation grille

Natural Thin Stone Veneer

BROWACOM PRODUCTS. Our web-pages can be found from:

Guidelines for Earthquake Bracing Residential Water Heaters

Hollow or Cinder Block Wall Mount Job Aid

NOTICE TO CONTRACTORS

Voted. by the National Association of Home Builders Survey and Builder Magazine

BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP"

Architectural Hardware Consulting Services

City of San Diego, CWP Guidelines

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Coursing Tables, Metric Shapes and Sizes

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Autobody/Collision and Repair Technology/Technician CIP Task Grid

Santa Barbara Lounge 24W x 31H x 24D AH22

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

Chapter 3 Pre-Installation, Foundations and Piers

Sample Calculations...V-CR-12. Door and Window Typical Combinations... V-CR-12 Horizontal and Vertical Typical Combinations...

Nomenclature for: Standard Steel Doors and Frames

Understanding BS EN 771-3: Aggregate concrete masonry units

PRODUCT SPECIFICATIONS

Guidelines for Earthquake Bracing of Residential Water Heaters

HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES

Triarch Products Over Various Interior Substrates

Ver. 2. Guide to. Inspecting Residential Brick Veneer

CHAPTER 2 QUANTITY TAKE-OFF

Vestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, , ]

The Building Group First Tuesdays First Saint Paul s Lutheran Church 1301 North LaSalle Street, Chicago, Illinois

How To Build A T7 Rack For Information Technology

C31 Property Damage Appraisal

Technical Notes 3B - Brick Masonry Section Properties May 1993

Slavic Village Building Condition Review

Sun Windows General Information Sun New Construction Window Installation Instructions

17,280 square feet Overview:

Building Condition Assessment: North Howard Street Baltimore, Maryland

International Greenhouse Company

Stainless Steel Continuous Hinges

Installation Detailed installation instructions are provided which should be strictly followed.

Packaged Terminal Air Conditioner Wall Sleeve Installation

Novoferm Interior Doors and Frames Just what you re looking for

White Paper FIRE DOOR INSPECTIONS, REPAIRS AND LABELING

14209-FUMC-DENTON - MONROE CENTER

Transcription:

TECHNICAL DATA SERIES S D I 110-09 Standard Steel Doors and Frames Masonry Construction 2014 Steel Door Institute STEEL DOOR INSTITUTE 30200 DETROIT ROAD CLEVELAND, OHIO 44145

SDI 110-09 Standard Steel Doors and Frames Masonry Construction The Module Definition: The size of any individual part, taken as a unit of measure regular proportion. A basic unit of measure adopted by the uilding Industry as 4 inches. Concept: The use of a standard modular dimension common to building products such as masonry improves finished structure by the following: Increased accuracy, legibility, and simplicity of working drawings and contract documents. Added aesthetic flexibility induced by small unit standardization, allowing freedom of architectural design. masonry construction meets the architectural need blending and continuity of components. Non-modular units interrupt a geometric pattern, or flow, by virtue of the discontinuity of line. As a specific case, the use of a butted frame () is extremely important in stack bonded masonry unit construction. Any interruptions, such as cut units, unit lintels, wrap-arounds, etc, destroy the strong linear function of such details. Increased flexibility of finished structure through lower modification, addition, and renovation costs. Reduced overall material and labor costs by facilitating the use of standard practices and definable operating procedures. Interchangeability of materials is facilitated by the ability to substitute modular components. Estimating and takeoff simplified. Detailing and drawing coordination between trades and specialties simplified by small size standard grid. s: Concrete masonry units (CMU) have been standardized to an 8" high and 16" long module. Also available are half blocks standardized to a 4" high and 16" long module commonly used as a starter course shown on page 4. The availability of loose TEE or wire masonry anchors can be an advantage over fixed masonry anchors since they field adjust to masonry joints. bricks have been standardized to a 2 2/3" high and 8" long module, theree 6 bricks correspond to the modular size of CMU. This relationship is clearly shown on pages 3 and 4. Adjustments have been made in actual sizes to allow common size mortar joints 2

SDI 110-09 Wrap Around Frame 6' 8" Door or 8' 0" Door Note: The masonry opening an 8 0 modular dimension opening and door opening height requires 12 courses of block or 36 courses of brick. Available in: X Standard Door Width 1 1* Single Swing 2 0 2 0 2 8 2 8 3 4 3 4 Double Swing 4 8 4 8 5 4 5 4 6 0 6 0 6 8 6 8 7 4 7 4 8 0 8 0 * May Vary ** opening = block width 0 +1/8 & Door Height 6' 8" A ** Detail Lintel as required Finish Floor Grid Masonry ** Notch masonry hardware provisions if required. SECTION A SECTION 3

SDI 110-09 Wrap Around Frame 7' 0" Door X Available in: Standard Door Width 1 1* Single Swing 2 0 2 0 2 8 2 8 3 4 3 4 Double Swing 4 8 4 8 5 4 5 4 6 0 6 0 6 8 6 8 7 4 7 4 8 0 8 0 * May Vary ** opening = block width 0 +1/8 & Door Height 7' 0" A ** Detail Lintel as required 4" Starter Course Finish Floor Grid Masonry ** Notch masonry hardware provisions if required. SECTION A SECTION 4

utt Type Frame SDI 110-09 7' 2" and 7' 10" Doors or 7' 0" Door (X) 4" Header Available in: X Standard Door Width Masonry 7' 4" Door Height 7' 0" A' Single Swing 2 8 2 4 3 4 3 0 4 0 3 8 Double Swing 5 4 5 0 7 4 7 0 Masonry 7' 4" and 8' 0" Door Height 7'-2" and 7' 10" A Finish Floor Grid 4" Sec. A' 7' 0" 7'2" and 7' 10" 2" Sec. A lock * SECTION A Detail Lintel as required *Single Rabbeted Frame Acceptable 2" * Masonry SECTION 2" 5

AVAILALE PULICATIONS MEMERS OF THE STEEL DOOR INSTITUTE Specifications ANSI/SDI A250.6 ANSI/SDI A250.8 SDI-108 SDI-118 SDI-128 SDI-129 Test Procedures Recommended Practice Hardware Reincings on Standard Steel Doors and Frames SDI 100 Specifications Standard Steel Doors & Frames Recommended Selection & Usage Guide Standard Steel Doors asic Fire Door, Fire Door Frame, Transom/Sidelight Frame, and Window Frame Requirements Guidelines Acoustical Permance of Standard Steel Doors & Frames Hinge & Strike Spacing ANSI/SDI A250.3 Test Procedure & Acceptance Criteria Factory Applied Finish Coatings Steel Doors & Frames ANSI/SDI A250.4 Test Procedure & Acceptance Criteria Physical Endurance Steel Doors, Frames and Frame Anchors ANSI/SDI A250.10 Test Procedure & Acceptance Criteria Prime Painted Steel Surfaces Steel Doors & Frames ANSI/SDI A250.13 Testing and Rating of Severe Windstorm Resistant Components Swinging Door Assemblies Protection of uilding Envelopes (Not applicable FEMA 320/361 or ICC-500 Shelters) SDI-113 Standard Practice Determining the Steady State Thermal Transmittance of Steel Door & Frame Assemblies SDI-131 Accelerated Physical Endurance Test Procedure Steel Doors, Frames and Frame Anchors Construction Details ANSI/SDI A250.11 Recommended Erection Instructions Steel Frames SDI-110 Standard Steel Doors & Frames Masonry Construction SDI-111 Recommended Details Standard Details Steel Doors, Frames, Accessories and Related Components SDI-122 Installation Troubleshooting Guide Standard Steel Doors & Frames Miscellaneous Documents SDI-112 SDI-117 SDI-124 SDI-127 SDI-130 SDI-134 Zinc-Coated (Galvanized/Galvannealed) Standard Steel Doors & Frames Manufacturing Tolerances Standard Steel Doors & Frames Maintenance of Standard Steel Doors & Frames Industry Alert Series (A-L) Electrified Hinge Preparations Nomenclature Standard Steel Doors & Steel Frames AUDIO-VISUAL PROGRAMS ALSO AVAILALE Ceco Door 9159 Telecom Drive Milan, TN 38358 (731) 686-8345 www.cecodoor.com Curries P.O. ox 1648 Mason City, IA 50402-1648 (641) 423-1334 www.curries.com Deansteel Manufacturing Co. 931 S. Flores Street San Antonio, TX 78204-1406 (210) 226-8271 www.deansteel.com DOOR COMPONENTS INC. 7980 Redwood Avenue Fontana, CA 92336-1638 (909) 770-5700 www.doorcomponents.com HOLLOW METAL XPRESS 602 S. 65th Avenue Phoenix, AZ 85043 623-936-7000 www.hmxpress.com Mesker Door, Inc. 3440 Stanwood oulevard Huntsville, AL 35811-9021 (256) 851-6670 www.meskerdoor.com MPI 319 North Hills Road Corbin, KY 40701 (606) 523-0173 www.metalproductsinc.com Pioneer Industries, Inc. 171 South Newman Street Hackensack, NJ 07601 (201) 933-1900 www.pioneerindustries.com Republic Doors & Frames 155 Republic Drive McKenzie, TN 38201-0580 (731) 352-3383 www.republicdoor.com Security Metal Products 5700 Hannum Avenue, Suite 250 Culver City, CA 90230 (310) 641-6690 www.secmet.com Steelcraft 9017 lue Ash Road Cincinnati, OH 45242 (513) 745-6400 www.steelcraft.com STEEL DOOR INSTITUTE 12/4/2014 30200 DETROIT ROAD CLEVELAND, OHIO 44145 440.899.0010 FAX 440.892.1404 www.steeldoor.org