Keysight U1253B True RMS OLED Multimeter

Similar documents
Agilent U1610/20A Handheld Digital Oscilloscope Quick Start Guide

AutoRanging Digital MultiMeter

Manual Ranging MultiMeter

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

User's Guide. True RMS Industrial Multimeter

Model UT201/202: OPERATING MANUAL. Table of Contents

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)

Model UT33A: OPERATING MANUAL Table of Contents (1)

UT202A Operating Manual. Contents

User Guide. Model Insulation Tester / Megohmmeter

Intelligent Digital Multimeters

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

Model UT58A/B/C: OPERATING MANUAL

10 Multimeter. Users Manual

Model UT60A: OPERATING MANUAL. Table of Contents. Page

i410/i1010 AC/DC Current Clamp

Table of Contents. Page

Model UT71A/B OPERATING MANUAL

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

DIGITAL MULTIMETER OPERATION MANUAL ITEM DIGITAL MULTIMETER CONTENTS

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL. Table of Contents

What is a multimeter?

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Current Monitoring Kit QUICK START GUIDE

Current Monitoring Kit

RS DIGITAL THERMOMETER

ABCs of DMMs Multimeter features and functions explained Application Note

Loop Calibration and Maintenance

HVAC Clamp Meter. Users Manual

Essential Electrical Concepts

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

12-Volt 10-Amp Regulated Power Supply

Owner s Manual & Safety Instructions

RADIANT PLASMA 4700 Plasma Spark Generator

7 FUNCTION DIGITAL MULTIMETER

Multimeter measurements on variable frequency drives using the new Fluke 289 DMM

AC Direct Off-Line Power Supplies

5000V Graphical Megohmmeter Model 5070

The Basics of Digital Multimeters

User Guide. 4 wire Earth Resistance Tester Model GRT300

Modular I/O System Analog and Digital Interface Modules

Instructions A Amp AC/DC Current Probe

Seven function digital multimeter

Diode Applications. As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off.

Kit Watt Audio Amplifier

How To Use A Cdm250 Digital Multimeter

No.1. Digital Multimeter RIGOL TECHNOLOGIES, INC.

1587/1577. Insulation Multimeters. Users Manual

AMP-210 AMP-210-EUR AMP-220 AMP-220-EUR AMP-310 AMP-310-EUR AMP-320 AMP-320-EUR. 600A AC TRMS Clamp Multimeter. 600A AC / DC TRMS Clamp Multimeter

RC Circuits and The Oscilloscope Physics Lab X

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW

3000W Power Inverter

Drayton Digistat +2RF/+3RF

TIG INVERTER INSTRUCTION MANUAL

Model UT713 OPERATING MANUAL

Digital Clamp-on DMMs with uncompromising performance

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Ground Resistance Clamp On Tester

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Experiment 2 Diode Applications: Rectifiers

323/324/325. Calibration Manual. Clamp Meter

User Manual for CH-PFC76810

The full wave rectifier consists of two diodes and a resister as shown in Figure

Fluke 3000 FC Series Test Tools Technical Data

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

Online UPS. PowerWalker VFI 1000R/1U

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Model 187 & 189. Users Manual. True RMS Multimeter

Properties of electrical signals

M 140i. Multifunction Calibrator. Operation Manual

MEGGER Insulation & Low Resistance Tester

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

Instruction Manual IDM 71/72/73 Digital Multimeter EN FR IT DE

DC POWER SUPPLY ALIMENTATION C.C.

Top Microsystems Proprietary Specification P/N: W090015HK-XP RB V.A0 SPECIFICATION

Agilent U1230 Series Handheld Digital Multimeters (DMMs)

Phoenixtech Brushless Motor Speed Controller Programming Guide

Lab E1: Introduction to Circuits

TROUBLESHOOTING, REPAIR, AND REPLACEMENT GUIDE FOR MODEL #19300 BATTERY CHARGER PLEASE SAVE THESE IMPORTANT SAFETY INSTRUCTIONS

ST Series POWER SUPPLIES USER INSTRUCTIONS

OUTPUT CABLE CONNECTIONS:

ECEN 1400, Introduction to Analog and Digital Electronics

4-Channel Thermometer / Datalogger

DC Electronic Loads 8500 series

Technical Update TAA.TU Rev. 1

INSTRUCTION MANUAL IPM Phase Power Analyser EN FR IT DE ES

Part No. IA Feb USER S MANUAL INSULATION RESISTANCE TESTER TOS7200

SX460. Generator Automatic Voltage Regulator Operation Manual

Fluke 1650B Series Multifunction Installation Testers

Transmitter Interface Program

Transcription:

Keysight U1253B True RMS OLED Multimeter Quick Start Guide

Keysight U1253B True RMS OLED Multimeter Quick Start Guide The following items are included with your multimeter: Silicone test leads 4 mm probes Alligator clips Printed Quick Start Guide Rechargeable 8.4 V battery Power cord and AC adapter Certificate of Calibration If anything is missing or damaged, please contact the nearest Keysight Sales Office. For more detailed information, please refer to the Keysight U1253B True RMS OLED Multimeter User s and Service Guide on Keysight Web site (www.keysight.com/find/handheld-tools). WARNING Ensure the terminal connections are correct for that particular measurement selection before starting any measurement. To avoid damage to the device, do not exceed the input limit.

Charging the Battery It is strongly recommended that you use the specified 24-volt DC adapter included as an accessory to charge the rechargeable battery. 1 Remove the test leads from the multimeter and turn the rotary switch to. 2 Plug the DC adapter into a power outlet. 3 Insert the red (+) and black ( ) banana plugs (4 mm plugs) of the DC adapter to the and terminals respectively. Ensure that the polarity of the connection is correct. 4 The display will show a countdown timer of 10 seconds for the self-test to start. The multimeter will output short single-tone sounds to remind you to charge the battery. Press to start charging the battery, or the multimeter will automatically start charging after 10 seconds. It is recommended not to charge the battery if the battery capacity is over 90%. NOTE For the battery charger, the main supply voltage fluctuations must not exceed ±10%. CAUTION Do not rotate the rotary switch from position when charging the battery. Perform battery charging only with 7.2 V or 8.4 V NiMH rechargeable battery, 9 V size. Disconnect test leads from all the terminals when charging the battery. Ensure proper insertion of battery in the multimeter, and follow the correct polarity. A new rechargeable battery comes in a discharged condition and must be charged before use (refer to the U1253B User's and Service Guide for charging instructions).

CAUTION Upon initial use (or after a prolonged storage period), the rechargeable battery may require three to four charge/discharge cycles before achieving maximum capacity. To discharge, simply run the multimeter under the rechargeable battery's power until it shuts down or the low battery warning appears. The multimeter may indicate that charging is complete after ten minutes when charging a new rechargeable battery. This is a normal phenomenon with rechargeable batteries. Remove the rechargeable battery from the device, reinsert it, and repeat the charging procedure. Functions and Features Action Steps Changes the OLED brightness Press. Freezes the measured value Press. Starts MIN MAX AVG NOW recording Offsets the measured value Press. Changes the measurement range Press. Press and hold for > 1 s. Turns on auto range Press and hold for > 1 s. Turns on dual display Press. Starts manual data logging Press and hold for > 1 s. Views the logged data Press for > 1 s, press or to scroll through the logged data. Clears the logged data Press for > 1 s, press for > 1 s. NOTE Your multimeter is capable of remote data logging. To use this feature, you will need an IR-USB cable (U1173A, purchased separately) and the Keysight GUI Data Logger Software (downloadable from www.keysight.com/find/hhtechlib).

Input Terminals and Overload Protection Measurement Functions Input Terminal Overload Protection Voltage COM 1000 Vrms Diode 1000 Vrms Resistance Capacitance Temperature Current (μa and ma) µa.ma COM < 0.3 A short circuit current 440 ma/1000 V 30 ka/fast-acting fuse Current (A) A COM 11 A/1000 V 30 ka/fast-acting fuse

Performing Voltage Measurements Measuring AC voltage 1 Set the rotary switch to. For and mode, press to ensure is shown on the display. 2 Connect the red and black test leads to input terminals V. mv (red) and COM (black) respectively. 3 Probe the test points and read the display. 4 Press to display dual measurements. Parameter can be switched consecutively. Measuring DC voltage For measuring DC voltage from a NOTE mixed signal in DC measurement mode, ensure that the Filter is enabled 1 Set the rotary switch to or. Ensure that is shown on the display. 2 Connect the red and black test leads to input terminals V. mv (red) and COM (black) respectively. 3 Probe the test points and read the display. 4 Press to display dual measurements. Parameter can be switched consecutively.

Using the Filter 1 Press and hold for more than 1 second to enter the multimeter s Setup menu. 2 Press or to scroll to menu 6. 3 Press or to browse to the DC Filter option. 4 Press to enter the Edit mode. 5 Press or to enable the DC Filter. 6 Press for more than 1 second to save your changes and exit the Edit mode. 7 Press and hold until the meter restarts and returns to its normal operating mode. CAUTION To avoid possible electric shock or personal injury, enable the Filter to verify the presence of hazardous DC voltages. Displayed DC voltages can be influenced by high frequency AC components and must be filtered to assure an accurate reading.

Performing Current Measurements To perform current measurements, set up your multimeter as shown in the figure below. For measuring DC current from a mixed signal in DC measurement mode, ensure that the Filter is enabled. Measuring AC current 1 Set the rotary switch to or. Press to ensure is shown on the display. 2 Connect the red and black test leads to input terminals µa.ma (red) and COM (black) or A (red) and COM (black) respectively. 3 Probe the test points in series with the circuit and read the display. Measuring DC current 1 Set the rotary switch to or. Ensure that is shown on the display. 2 Connect the red and black test leads to input terminals µa.ma (red) and COM (black) or A (red) and COM (black) respectively. 3 Probe the test points in series with the circuit and read the display. CAUTION If the current is 440 ma, connect the red and black test leads to input terminals µa.ma (red) and COM (black). If the current is > 440 ma, connect the red and black test leads to input terminals A (red) and COM (black).

Performing Resistance, Conductance, and Continuity Measurements PRESS SHIFT Audible continuity PRESS SHIFT 1 Set the rotary switch to. 2 Connect the red and black test leads to input terminals Ω (red) and COM (black) respectively. 3 Probe the test points (by shunting the resistor) and read the display. 4 Press to scroll through audible continuity ( / ), conductance ( ), and resistance tests (,, or ) as shown.

Performing Capacitance and Temperature Measurements Capacitance 1 Set the rotary switch to. 2 Connect the red and black test leads to input terminals (red) and COM (black) respectively. 3 Connect the red test lead to the positive terminal of the capacitor, and the black test lead to the negative terminal. 4 Read the display. Temperature 1 Set the rotary switch to. Press to select temperature measurement. 2 Connect the red and black test leads to input terminals (red) and COM (black) respectively. 3 Plug the thermocouple adapter (with the thermocouple probe connected to it) into input terminals (red) and COM (black). 4 Touch the measurement surface with the thermocouple probe. 5 Read the display.

Frequency and Frequency Counter Measurements Frequency Measurement During AC/DC voltage or AC/DC current measurements, you can measure the signal frequency by pressing at any time. Frequency Counter Measurement 1 Set the rotary switch to. 2 Press to select the frequency counter ( ) function. The default input signal frequency is divided by 1. This allows signals up to a maximum frequency of 985 khz to be measured. 3 Connect the red and black test leads to input terminals V (red) and COM (black) respectively. 4 Probe the test points and read the display. 5 If the reading is unstable or zero, press to select division of input signal frequency by 100 ( will be shown on the display). This accommodates a higher frequency range of up to 20 MHz. 6 The signal is out of the U1253B frequency measurement range of 20 MHz if the reading is still unstable after step 5. WARNING Use the frequency counter for low voltage applications. Never use the frequency counter on AC power line systems. For input more than 30 Vpp, you are required to use frequency measurement mode available under the current or voltage measurement instead of frequency counter.

Square Wave Output 1 Turn the rotary switch to. 2 Press to select duty cycle (%) on the primary display. 3 The default square wave frequency is 600 Hz as shown by the secondary display, with a 50% duty cycle as shown by the primary display. 4 Press or to scroll through the available frequencies (there are 28 frequencies to choose from). 5 Press or to adjust the duty cycle. The duty cycle can be set from 0.390625% to 99.609375%, in steps of 0.390625%. The displayed duty cycle has a resolution of 0.001%.

Safety Notices Safety Symbols CAUTION WARNING A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met. CAT III 1000 V CAT IV 600 V Earth (ground) terminal Equipment protected throughout by double insulation or reinforced insulation Caution, risk of electric shock Caution, risk of danger (refer to the instrument manual for specific Warning or Caution information) Category III 1000 V overvoltage protection Category IV 600 V overvoltage protection Safety Information This meter is safety-certified in compliance with EN/IEC 61010-1:2001, UL 61010-1 Second Edition and CAN/CSA 22.2 61010-1 Second Edition, CAT III 1000 V/Category IV 600 V, Pollution Degree II. Use with standard or compatible test probes. For further safety information details, refer to the Keysight U1253B True RMS OLED Multimeter User s and Service Guide.

This information is subject to change without notice. Keysight Technologies 2009-2014 Edition 5, August 2014 *U1253-90045* U1253-90045 www.keysight.com