O5: Lenses and the refractor telescope

Similar documents
EXPERIMENT 6 OPTICS: FOCAL LENGTH OF A LENS

Geometric Optics Converging Lenses and Mirrors Physics Lab IV

Solution Derivations for Capa #14

9/16 Optics 1 /11 GEOMETRIC OPTICS

Thin Lenses Drawing Ray Diagrams

2) A convex lens is known as a diverging lens and a concave lens is known as a converging lens. Answer: FALSE Diff: 1 Var: 1 Page Ref: Sec.

Chapter 17: Light and Image Formation

RAY OPTICS II 7.1 INTRODUCTION

Chapter 27 Optical Instruments The Human Eye and the Camera 27.2 Lenses in Combination and Corrective Optics 27.3 The Magnifying Glass

Experiment 3 Lenses and Images

Procedure: Geometrical Optics. Theory Refer to your Lab Manual, pages Equipment Needed

Convex Mirrors. Ray Diagram for Convex Mirror

Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002

Basic Optics System OS-8515C

1. You stand two feet away from a plane mirror. How far is it from you to your image? a. 2.0 ft c. 4.0 ft b. 3.0 ft d. 5.0 ft

How to make a Galileian Telescope

Lenses and Telescopes

Lesson 29: Lenses. Double Concave. Double Convex. Planoconcave. Planoconvex. Convex meniscus. Concave meniscus

Lecture 17. Image formation Ray tracing Calculation. Lenses Convex Concave. Mirrors Convex Concave. Optical instruments

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

waves rays Consider rays of light from an object being reflected by a plane mirror (the rays are diverging): mirror object

LIGHT SECTION 6-REFRACTION-BENDING LIGHT From Hands on Science by Linda Poore, 2003.

Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure

C) D) As object AB is moved from its present position toward the left, the size of the image produced A) decreases B) increases C) remains the same

Lesson 26: Reflection & Mirror Diagrams

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

Chapter 36 - Lenses. A PowerPoint Presentation by Paul E. Tippens, Professor of Physics Southern Polytechnic State University

1 of 9 2/9/2010 3:38 PM

EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab

OPTICAL IMAGES DUE TO LENSES AND MIRRORS *

Chapter 22: Mirrors and Lenses

Care and Use of the Compound Microscope

Geometrical Optics - Grade 11

Physics 116. Nov 4, Session 22 Review: ray optics. R. J. Wilkes

7.2. Focusing devices: Unit 7.2. context. Lenses and curved mirrors. Lenses. The language of optics

Light and its effects

Science In Action 8 Unit C - Light and Optical Systems. 1.1 The Challenge of light

Torque and Rotary Motion

Microscope Lab Introduction to the Microscope Lab Activity

Physics, Chapter 38: Mirrors and Lenses

Light and Sound. Pupil Booklet

THE BOHR QUANTUM MODEL

LIGHT REFLECTION AND REFRACTION

Magnification Devices

FirstView 3 Reflector Telescope Owner s Manual

Interference. Physics 102 Workshop #3. General Instructions

Making a reflector telescope

Calculating Astronomical Unit from Venus Transit

UNIVERSITY OF SASKATCHEWAN Department of Physics and Engineering Physics

Reflection and Refraction

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

Light Telescopes. Grade Level: class periods (more if in-depth research occurs)

Instruction Manual Genesis 200 EQ

The light. Light (normally spreads out straight and into all directions. Refraction of light

Rutgers Analytical Physics 750:228, Spring 2016 ( RUPHY228S16 )

Acceleration of Gravity Lab Basic Version

Smart Cam, CC-Smart-Cam, and Smart Cam Packages Installation and Quick Start Operating Instructions

Measuring the Diameter of the Sun

HOMEWORK 4 with Solutions

E/M Experiment: Electrons in a Magnetic Field.

CALIBRATION FOR LAL20X & LAL24X

Protocol for Microscope Calibration

Study Guide for Exam on Light

Handy Pinhole Camera (Latin Camera Obscura) to observe the transit of Venus, eclipses and other phenomena occurring on the Sun

Rotational Motion: Moment of Inertia

Buying Your First Telescope By Mike Usher

Solar Observing in Schools

Diffraction of Laser Light

Lab 9: The Acousto-Optic Effect

Ampere's Law. Introduction. times the current enclosed in that loop: Ampere's Law states that the line integral of B and dl over a closed path is 0

Optics. Kepler's telescope and Galileo's telescope. f 1. f 2. LD Physics Leaflets P Geometrical optics Optical instruments

Your first. Buying a scope for the first time can be daunting. We reveal what you shoud look for and how to get up and running.

Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012

GENERAL SCIENCE LABORATORY 1110L Lab Experiment 3: PROJECTILE MOTION

SolidWorks Tutorial 4 CANDLESTICK

MACRO PHOTO LENS. MP-E 65mm f/ ENG. Instruction

Lab 3 - DC Circuits and Ohm s Law

Magnetic Fields and Their Effects

M A R C O. CP-670 AUTOMATIC CHART PROJECTOR Instruction Manual

Paper 1. Calculator not allowed. Mathematics test. First name. Last name. School. Remember KEY STAGE 3 TIER 4 6

Understanding astigmatism Spring 2003

FRICTION, WORK, AND THE INCLINED PLANE

FORCE ON A CURRENT IN A MAGNETIC FIELD

Physics 25 Exam 3 November 3, 2009

VISM Evolution Scope Series

Physics 41, Winter 1998 Lab 1 - The Current Balance. Theory

PROFESSIONAL REFRACTOR MODEL

In this project, you will be observing at least three objects with a telescope or binoculars, and drawing what you see.

PlaneWave CDK Telescope Instructions CDK12.5, 17, 20 and 24

Vision Correction in Camera Viewfinders

Observing the Sun NEVER LOOK DIRECTLY AT THE SUN!!! Image taken from the SOHO web-site

ACCELERATION DUE TO GRAVITY

VISM CQB Scope Series

First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between

FIFTH GRADE WORKBOOK

Polarization of Light

Lenses and Apertures of A TEM

Build Your Own Solar Car Teach build learn renewable Energy! Page 1 of 1

1 Laboratory #5: Grating Spectrometer

Transcription:

O5. 1 O5: Lenses and the refractor telescope Introduction In this experiment, you will study converging lenses and the lens equation. You will make several measurements of the focal length of lenses and you will construct a simple astronomical telescope. The components you will use are a kit from Learning Technologies, Inc. (www.starlab.com). At the end of the experiment the telescope is yours to keep. Theory When a bundle of parallel light rays, called a collimated light beam, enters a converging lens, the rays are focused to a point in space a distance f, the focal length, from the surface of the lens. A converging lens is convex in shape, that is, thick in the middle and thin at the edges. A diverging lens is concave in shape, i.e. thin in the middle and thicker near the edges. Note that the diverging lens has a virtual image to the left of the lens, where the light rays never actually cross. The converging lens produces a real image where the rays do cross. Figure 1: Basic Lenses A converging lens can be used to form an image on a screen for an object. The lens equation relates the focal length f of a lens, the object distance d o, and the image distance d! : (1)!! =!!! +!!! (This equation can be used for both converging and diverging lenses; the only difference is that the focal length is positive for converging lenses, negative for diverging lenses.) Figure 2: Simple Ray-Tracing Diagram

O5. 2 In the diagram above, the points labeled f are the focal points of the lens. The lateral magnification m of the image is defined as: m = h! h!. From the diagram above, one can show that m can also be written as: m = d! d!. Experimental Methods In this lab, you will use two different techniques to measure focal lengths. Method I: You will take a collimated beam of light (parallel rays) and focus this to a point using each of the converging lenses used for your telescope. The distance from the center of the lens to the screen, when the optimal focus is achieved, tells us the focal distance of the lens. Equation [1] can also be applied to this situation. Since the incoming rays are parallel, the distance to the object is: d o =, or 1/d o = 0. In this case it is clear that d i = f. Figure 3: Converging Lens used to focus a collimated beam To do this in the experiment you will first need to produce a collimated beam to measure the focal distances of your telescope lenses. This will be produced by the complementary collimating lens that is used to convert a point source of light (the LED at the center of the light source) into a parallel beam of light, as shown below: Figure 4: Lens used to collimate a beam The point source is the object and the object distance d o is the focal length f. With d o = f, equation [1] predicts that d! =. The rays from the lens converge "at infinity". Method II: This method uses a lens to form the real image of an object where the distances d i and d o are measured, whereupon equation [1] is used to compute f. In the last part of this lab, you will construct a simple astronomical telescope. The

O5. 3 astronomical telescope consists of two lenses: an objective lens with a long focal length f o, and an eyepiece lens with a short focal length f e. The objective lens forms the image of a distant object "at infinity". The lens equation tells us if the object distance is: d! =, then the image distance is d! = f!. This image, which appears a distance f o behind the objective lens, is called an intermediate image, because it is intermediate between the objective and eyepiece lens. The observer views this image through the eyepiece lens, which acts as a magnifying glass. Note that a magnifying glass produces the largest magnification when the magnified object (i.e. the intermediate image in this case) is held a distance f e from the magnifying glass. The angular magnification of the telescope is defined as the ratio: M = θ θ, where (as shown in figure [5]) θ is the angular size of the image as viewed by the observer through the telescope and θ is the angular size of the distant object as viewed without the telescope. θ θ Figure 5: Objective and eyepiece lens ray-tracing diagram Notice that the distance between the two lenses is: l = f! + f!. From the diagram above, one can show that the angular magnification can also be written as: M = f! f!, the ratio of the focal lengths of the objective and eyepiece lenses. Experimental Procedure Part 0 Equipment Considerations (The Most Important Part) In this lab, you will use an optics bench, which is simply a rail on which lenses are placed with a meter stick mounted on the side for measuring distances. The optics (light source, lenses, and screen) are mounted on carts that slide along the rail. The carts have markers on the side to help measure distances using the two-meter stick. Each station has a variable intensity LED light source fixed at one end of the optics bench. There will be no need for you to slide the light source along the bench. Handle this component with care, and only make adjustments when necessary! If you need to adjust the height of the light source, turn off the power, loosen the thumbscrew on the post holder, gently slide the post attached to the LED mount up or down, and secure the thumbscrew. In addition to the light source there are four carts with post holders that can slide along the bench. These carts should remain on the bench throughout the experiment. If the cart comes off the rail or seizes and cannot move, contact the T.A. or an 1140 staff member for assistance. Each station has the optics mounted on posts. The lenses are mounted in lens holders along with the arrow, and the screen is a piece of paper. Place the lens and post assembly into the cart and post holder assembly by loosening the thumbscrew on the post holder (if necessary), place the lens and post into the post holder, adjust it to the necessary height, and tighten the

O5. 4 thumbscrew. DO NOT remove the lens from the lens holder. Be sure not to loosen the thumbscrews too much as they are easily lost when removed from the post holder. All the optics are labeled on the posts. When you are finished making measurements, place all of the optics back into the bin near the bench. If you are missing any components before you start the lab, contact your T.A. or 1140 staff member. DO NOT go hunting for optics at other stations. Once finished making measurements with the main apparatus, you will construct your own telescope consisting of two cardboard telescoping tubes, a small eyepiece lens in grey foam, and a large objective lens in a red plastic holder. These components are found in the folder room. Find your T.A. or 1140 staff member to help you construct your telescope. Part I Use of a collimated beam In this part you will use Method I to measure the focal length of each of your telescope lenses. On the LED power supply make sure the switch is on its left most position, then turn the dial clockwise until you have adequate brightness, approximately 2/3-3/4 of a turn. The actual LED is small enough that we can consider it to be a point source. Use the lens labeled Collimating Lens to form a parallel beam of light by positioning the lens so that its focus coincides with the filament of the light bulb. You can do this by studying the image of the lens on a piece of paper and moving the paper away from the lens in the direction of the beam. When the lens is positioned properly, the size of the light spot on the paper should not change with the paper position, and it should be the size of the lens. If the lens is too low, loosen the thumbscrew on the post holder, adjust the height and retighten, but try not to rotate the lens. Use the pointer on the cart and meter stick mounted beside the track to measure distances. Note that depending upon whether the paper is very close or far from the lens you may see a blue or a red halo around the beam spot, which has to do with chromatic aberration of the lens (different colors are focused slightly differently since they have different effective indexes of refraction in the lens). You should be working far from the lens where the halo is red. Once a collimated beam is formed, the focal length of the objective and eyepiece lenses can be measured. These lenses are labeled Objective Lens and Eyepiece Lens. You can do this by placing one of the lenses in the collimated beam and focusing it on the screen so that a single point of light is observed. Measure the focal distance using the pointers and meter stick. Adjust the height of the lenses or screen if necessary. Make a few measurements (3-4) of the focal distance for each lens and estimate the uncertianty. For each new trial, readjust the collimation of the parallel beam of light so that any errors from this step of the measurement are averaged. Part II Images and Magnification. In this part, you will use Method II to measure the focal length the two telescope lenses. The procedure for this is as follows: (1) Place the arrow in front of the light source. Record the position of the arrow using the meter stick and marker. (2) Arrange the eyepiece lens and the screen so that a sharp image of the arrow appears on the screen (the situation will be similar to the bottom figure on page 1). Measure the distances d i and d o, as well as the image height h! and object height h!. The heights are measured with a set of plastic calipers. If you make pen/pencil marks on the image screen to

O5. 5 measure the heights, let your T.A. or 1140 staff member know, so it can be replaced when you are finished. Compute the lateral magnification m = h! h! and compare d! d!. Do the same, but for a different set of distances: d i and d o, again measuring height h i and height h o. Check how close equation [1] works for each of these cases using your measurement for the focal length from the previous part. (Hint: the overall spacing between the object, lens, and image screen is small.) (3) Repeat step (2), but replace the eyepiece lens with the objective lens. (Hint: make sure there is ample spacing between the object, lens, and image screen.) (4) At this point place all of the optics back in the bin, since you will not need this apparatus for Part III. Be sure to turn off the light source by turning the knob on the power supply until a click is heard. Part III The Astronomical Telescope In this part you will construct the telescope and estimate its magnification. In the folder room you will find all the necessary components to make your telescope. DO NOT use the lenses from the bins at the optics bench. Choose the lens with the longest focal length. This will be the objective lens with focal length f o. Also choose the lens with the shortest focal length. This will be the eyepiece with focal length f e. Place the eyepiece at one of the tube in a foam mount and place the objective lens in a red plastic mount a distance l = f! + f! from the eyepiece, aka. the length of the tube. Place the telescope on the rail near the two torsional pendulum stations. Aim the telescope towards the far end of the room, where there is an arrow and a graduated scale mounted on the wall, and adjust the telescope position until you can see the arrow through the telescope. It may be difficult to find the image since your telescope has a narrow field of view. Also, you may need to adjust the position of the eyepiece lens to get a sharp image. Is the final image you are looking at upright or inverted? Is it real or virtual? Explain your answers with words and diagrams. Once you have found a clear image looking through the telescope, open your other eye so that you can look simultaneously at the enlarged image with one eye and the un-enlarged image with the other eye. If you position the telescope just right, you can see the two scales side by side and estimate the angular magnification M of your telescope. It may be helpful to compare the full height of the piece of paper to the distance between each of the markings (which are 1/10 of the height of the paper). Compare your answer with the theoretical value of M. Keep in mind this is a very subjective measurement. The telescope is yours to keep! Guiding Questions. 1. What is the definition of the focal length of a converging lens? Illustrate your answer with a diagram. 2. Consider a lens with a focal length of f = 20.0 cm which is used to image an object of height h o = 4.0 cm, a distance d o = 40.0 cm away. On graph paper, draw a diagram showing the size (h i ) and position (d i ) of the image formed by this lens. Check that the value of d i obtained from your graph agrees with a calculation of d i made by equation [1].

O5. 6 3. Using figure [1] show that: d i d o = h i h o.s 4. Redo problem (2) but with the distance d o = 30.0 cm. What is the image distance d i? What will the image height h i be? 5. What is a collimated beam? Draw a sketch showing how you could produce one. Could you make a collimated beam using only a point source and a diverging lens? 6. An astronomical telescope has an objective lens with a focal length of 600mm and an eyepiece lens with a focal length of 30mm. What is the angular magnification of this telescope? 7. The Earth s moon as seen from the surface of the Earth has an angular size of roughly 0.5 degrees. We say that it subtends an angle of 0.5 degrees. What is this angle in radians? The radian angular measurement is convenient because (by definition) the angle in radians is the ratio of the length of arc subtended to the radius of the circle. 8. If the Moon is roughly 385,000 km from the Earth, what must the Moon s diameter be to subtend this angle? How does that diameter compare to the Earth s diameter? How does the angle subtended by the Moon compare with the angle subtended by your thumbnail when you hold your arm straight out? 9. During a full solar eclipse, the Moon almost exactly covers the disk of the Sun. In other words, they subtend the same angle. If the distance from the Earth to the Sun is roughly 150 million kilometers, what is the diameter of the Sun? 10. If you were to look at the moon with the telescope described in problem 6, what effective angle would the moon subtend as viewed through the telescope?

O5. 7 Pre-lab assignment for O5: Lenses and the Refractor Telescope. This prelab is designed to focus your attention on what is important in the lab before you start the experiment and give you a leg up on writing your report. Use this template when you write your report. 1. Carefully read the lab instructions for O5 2. Using Mathematica, set up a template for your lab report. This will include: I. Header information such as title, author, lab partner, and lab section: (to do this, In Mathematica, go to File, Print Settings, Header and Footer from this dialog box you can enter all of the required information.) Mathematica automatically enters the file name in the right side of the header. Leave this alone. II. Section Headings including Title, Summary of Experiment, Data and Calculations, Discussion of Uncertainty, and specific section headings for each part of the experiment. (All of the Physics 1140 lab manuals include multiple parts.) 3. Write a Summary of the experiment. What are you going to measure and what data will you collect to make the measurement? (For example, in part one of M1, you will measure the length of a pendulum along with the period of the pendulum to determine the acceleration due to gravity.) 4. For each part of the lab do the following: A.) For Part 1, Describe the process of creating a collimated beam of light and how it will help us to determine the focal lengths of our objective and eyepiece lenses. (Specifically talk about what is happening with the light rays through this process.) B.) For Part 2, Are the images you observe real images or virtual images? How do you know? C.) For Part 3, Calculate the magnification of an image given the following focal lengths: f objective = 2.3cm, f eyepiece = 0.4cm Remember every graph in 1140 should have the following: (There are no graphs for this Prelab) I. Plot your theory or expectation as a line. (In Mathematica, you should define a function and plot it using the command Plot ) Reference the Mathematica tutorial to do this.

O5. 8 II. Label your axes, in English (not just symbols) and with units. III. Include a brief caption (namely, a text statement of what the plot shows.) IV. Set the x and y range of the plot to be close to what you expect for your data. For example: in M1 your longest length pendulum should be no more than 130 cm in length. 5. Write a Discussion of Uncertainty. What are the major sources of uncertainty in the experiment and how will you account for them? 6. Turn in a printout of your Mathematica document that includes 2-5 above. This document should be no more than 2 pages long.