AC OUTPUT 430XAC 460XAC Power rating 1Ø2W 3000VA 6000VA 1Ø3W Total 2000VA Total 4000VA (1000VA per ) (2000VA per ) 3Ø4W Total 3000VA Total 6000VA (100

Similar documents
1.44 kw Programmable DC Power Supplies XLN Series

Connecting instruments serially to your computer

OZW30. Central Unit SYNERGYR

UNLOCK YOUR IEC TESTING EXCELLENCE

NC-12 Modbus Application

Installation manual. Generator Paralleling Controller GPC multi-line C

DC Electronic Loads 8500 series

Electrical Safety Tester Verification

PCS0100en Persy Control Services B.V. Netherlands

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

TECHNICAL BULLETIN. Wiring Diagrams. TPI Wiring. TB Rev. March 4, 2013 Page 1 of 5. Switch Settings 3 PHASE POWER SUPPLY 3 PHASE POWER SUPPLY

Disturbance Recoder SPCR 8C27. Product Guide

Product Information Sheet UH36 Hi Pot Tester

Definition AC Power Distribution

Telefon (+45) Telefax (+45) Installation and operating manual

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Thyristor-controlled power supplies and battery chargers

SELF-POWERED VOLTAGE DETECTING & PROTECTING RELAY

High Power Programmable DC Power Supplies PVS Series

Using installed Fieldbus Wiring to carry Ethernet Communications

How to read this guide

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

VLT 6000 HVAC. Contents

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Multi-Range Programmable DC Power Supplies 9115 Series

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Figure. 1 - Split Phase 240/120V circuit (180 phase shift)

Centro-Matic Automatic Lubrication Systems System Controls

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

SL Series AC and DC Electronic Loads

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

APPLICATION NOTE USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS. Abstract.

Application/Connection Examples

Permissible ambient temperature Operation Storage, transport

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

Considerations When Specifying a DC Power Supply

HVDP. High Voltage Dynamic Power supply/source. 1, 2.5 and 5kW Output DC + Sine Wave Family

SYSTEM 45. C R H Electronics Design

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

CVA Range. Control and Monitoring Facilities. Established Leaders in Valve Actuation. Electric Actuators and Control Systems

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Connecting your Victron product to a computer with VE Configure

ATS Communication Overview

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

Tool Turrets and Tool Discs

Speed Control Relays SX2

Temperature & Humidity SMS Alert Controller

PowerGem Pro Uninterruptible Power Supply

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

VOICE RECORDING SYSTEM ISDN PRI / BRI

Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide

HI/ICMI UVR-1 Universal Voltage Regulator Control

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

Multi-Range Programmable DC Power Supplies 9115 Series

Supplemental User Guide

RX-6 Six In - One Out All in One Receive Antenna Switch Local and Remote Control System RX6ACI User Manual Version 2.1

MINIMAT-EC-Servo Screwdriver Spindles

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

CMP-102U. Quick Installation Guide

Operation and Installation Manual

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

Digital multimeters DMG

STIM202 Evaluation Kit

Telephone- and leased line modem for industrial applications TD-36

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

MANUAL PC1000R

Step Voltage Regulators

Cesar RF Power Supplies: 2, 4, 13.56, 27.12, and MHz; 300 W to 5 kw

Series Six Plus Programmable Controller

Using MCC GPIB Products with LabVIEW

SNMP Web Management. User s Manual For SNMP Web Card/Box

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Lab 3: Introduction to Data Acquisition Cards

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

CRE Monitor Instructions Manual

Solid State Timers Type F

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Communication with BushingGard using computer USB port

Dash 8Xe / Dash 8X Data Acquisition Recorder

Quick Start Guide for High Voltage Solar Inverter DC-AC Board EVM. Version 1.3

Configure Inverter output for two utility settings, (1)120V/60Hz, (2)220V/50Hz

Cisco Unified IP Phone Power Injector

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

Config software for D2 systems USER S MANUAL

Analog Servo Drive 25A8

SX460. Generator Automatic Voltage Regulator Operation Manual

DCS Series 1 kw, 1.2 kw, & 3 kw

4 Port full HD multiviewer real-time USB/KVM switch

Transcription:

The 400XAC Series: Two Major Advantages that Simplify Functional Testing Associated Power Technologies The Hurdles of Functional Testing One of the most difficult aspects of product testing is finding a power source that can cover a multitude of functional testing capabilities. Often times, test engineers and production managers end up having to purchase multiple power sources to cover all of their testing needs. This presents a couple problems. First, different pieces of equipment may not be compatible with one another forcing the end user to alter their lab or production line setup in order to compensate for this lack of flexibility. Second, if the power sources need to be placed in an automated station, the user is forced to program multiple sources to setup sequences and gather test data. This can be a long and tedious process, especially if a company does not have programming engineers in house. Associated Power Technologies 400XAC series 3Ø power sources were designed to address these problems. This paper will outline the various output modes of the 400XAC series as well as its automation capabilities. This product family can address the common problems of functional testing by providing flexible output modes with the ability to fully remotely program the instrument from a PC bus. Versatile Output The 400XAC product family was designed as a versatile, three power source with two standard models: the 430XAC (3kVA source) and the 460XAC (6kVA source). Their standard configuration is a three four wire output; however, these sources can also be configured for single (1Ø2 wire), split (1Ø3 wire) and DC output. One of the biggest benefits of these sources is that switching between output modes is made simple. This is due to the fact that the source internally changes the configuration based on user driven menu selections; no internal hardware modification is required to interchange output modes. The output specifications for each operation mode are listed in Table 1. (Note: Only one output mode can be activated at any given time. All voltages, including 3Ø4W, are listed as voltages Phase to Neutral. All voltage settings through the menu are also set as the voltage)

AC OUTPUT 430XAC 460XAC Power rating 1Ø2W 3000VA 6000VA 1Ø3W Total 2000VA Total 4000VA (1000VA per ) (2000VA per ) 3Ø4W Total 3000VA Total 6000VA (1000VA per ) (2000VA per ) DC 3000VA 6000VA Frequency Range 40-1000Hz Full Range Adjustable Max.Current (r.m.s) 1Ø2W 0~150V 27.6A at <110V 55.2A at <110V 0~300V 13.8A at <220V 27.6A at <220V 1Ø3W 0~150V 9.2A at <110V for per 18.4A at <110V for per 0~300V 4.6A at <220V for per 9.2A at <220V for per 3Ø4W 0~150V 9.2A at <110V for per 18.4A at <110V for per 0~300V 4.6A at <220V for per 9.2A at <220V for per DC 5~210V 14.4A 28.8A 5~420V 7.2A 14.4A Table 1: 400XAC AC Output Specifications This type of flexible output configuration is made possible because of the 400XAC s flexible design. Internal relays controlled by the instrument allow the user to change the output mode through the front panel menus. Based on the selected mode, the 400XAC s internal relays will automatically configure the necessary output. Due to this type of design, the instruments also have the capability to measure (voltage, current, power, power factor) on each individual (A,B or C) as well as the total measurement ( ). This allows the user to monitor the characteristic of the load by changing the parameters through the menu. Remote Control and Automated Capability While the configurable output allows the 400XAC series to cover a wide range of applications, its automation capabilities set this series apart. The 400XAC series instruments come standard with USB and RS-232 ports but can also be controlled via GPIB and Ethernet. The instruments can be remotely controlled via these communication types with an ASCII-based command set. Any available user driven menu selection can also be controlled remotely by sending commands from a PC. This allows the user to create test suites for various setups and applications. With 50 memories and 9 steps per memory, the user can remotely configure up to 450 total tests. The next section outlines a series of test application examples for which a user would remotely program the instrument. In the examples, the user has purchased a 430XAC for functional testing on various types of motors. Each row of the tables show the command sent to the unit as well as the command

description. The corresponding figure outlines the connection diagram for each test scenario. (Note: For the full command set and syntax description for the 400XAC instruments, please refer to Chapter 9 in the 400XAC product manual: Bus Remote Interface). Figure 1 shows the output terminal and connection description for each type of output mode. Figures 2-6 illustrate possible connections to a load for each output mode. Tables 2-6 outline the commands remotely sent to the 430XAC for each testing scenario. Figure 1: Output Terminal Block and Output Connection Description Application Setup 1 The user would like to power a three motor and monitor the motor s metrics. The motor is a 5 horse power 208VAC motor with a Wye connection. The current draw must stay within 10% of its rated value (18A with a 5HP motor at 208VAC): Figure 2: 3Ø4W Configuration (Wye Load)

FUNCTION 1 Set power source to 3Ø4W mode. MEMORY 1 Set unit to memory slot 1 STEP 1 Set unit to step 1 of memory 1 VOLT 120 Set output voltage to 208VAC (voltage setting is Phase voltage i.e. to neutral) RAMPUP 0.5 Set the ramp up timer to 0.5sec DELAY 5.0 Set the delay timer to 5 seconds DWELL 180.0 Set the dwell timer to 180 seconds RAMPDOWN 0.5 Set the ramp down timer to 0.5sec PS 3 Monitor total 3 power (instead of individual ) AHI 19.8 Current high limit set to 19.8A (+10% of 18A) ALO 16.2 Current low limit set to 16.2A (-10% of 18A) Query unit for total 3 data. Queried data will be returned in the following format: TDE? Memory,Step,Status,Frequency,Volt,Current,Power, Peak Current,Power Factor,Reactive Power,Crest Factor,VA,Timer TDA? TDB? TDC? Query unit for A measurements Query unit for B measurements Query unit for C measurements Table 2: 3Ø4W Program Setup Application Setup 2 Next, the user needs to change the configuration to test a motor with a delta connection. The motor has the same specifications as the motor from application setup 1. In this case, all the user needs to do is connect the motor as shown in Figure 3 and disconnect the neutral. The user s parameters will not change so all that would need to be sent to the instrument is the command to start the test and query for data.

Figure 3: 3Ø3W Configuration (Delta Load) TDE? TDA? TDB? TDC? Query unit for total 3 data. Query unit for A measurements Query unit for B measurements Query unit for C measurements Table 3: 3Ø3W Program Setup Application Setup 3 The user now needs to test a standard single load. The load is a single 3/4HP motor used in a garbage disposal. This motor runs from a standard 120VAC supply and the max output must stay within 5% of its value (max 4.7A at 120VAC). First, the user needs to connect the supply as shown in Figure 4. The user then sends the commands shown in Table 3 to program and control the source. Figure 4: 1Ø2W Configuration

FUNCTION 0 Set power source to 1Ø2W mode. MEMORY 2 Set unit to memory slot 2 STEP 1 Set unit to step 1 of memory 2 VOLT 120 Set output voltage to 120VAC RAMPUP 0.5 Set the ramp up timer to 0.5sec DELAY 5.0 Set the delay timer to 5 seconds DWELL 120.0 Set the dwell timer to 120 seconds RAMPDOWN 0.5 Set the ramp down timer to 0.5sec AHI 4.94 Current high limit set to 4.94A (+5% of 4.7A) ALO 4.47 Current low limit set to 4.47A (-5% of 4.7A) TD? Query unit for test data. Table 4: 1Ø2W Program Setup Application Setup 4 The user needs to test a split motor used in clothes washers. The load is a split 1HP motor. This motor runs from a 240VAC supply and the max output must stay within 10% of its value (max 3.1A at 240VAC). First, the user needs to connect the supply as shown in Figure 5. The user then sends the commands shown in Table 4. Figure 5: 1Ø3W Configuration

FUNCTION 2 Set power source to 1Ø3W mode. MEMORY 3 Set unit to memory slot 3 STEP 1 Set unit to step 1 of memory 3 VOLT 120 Set output voltage to 240VAC (voltage setting is the line to neutral voltage) RAMPUP 0.5 Set the ramp up timer to 0.5sec DELAY 5.0 Set the delay timer to 5 seconds DWELL 120.0 Set the dwell timer to 120 seconds RAMPDOWN 0.5 Set the ramp down timer to 0.5sec AHI 4.94 Current high limit set to 3.41A (+10% of 3.41A) ALO 2.79 Current low limit set to 2.79A (-10% of 3.1A) TD? Query unit for test data. Table 5: 1Ø3W Program Setup Application Setup 5 Finally, the user needs to test a small DC motor. The motor is a 1/4HP, 90VDC 2.5A max load motor. The current draw cannot exceed 2.5A and the voltage output cannot dip below 80VDC. The user connects the motor as shown in Figure 6 and sends the commands shown in Table 5. Figure 6: DC Output Configuration

FUNCTION 0 Set power source to 1Ø2W mode (for DC, must use 1Ø2W mode). OM 1 Set power source to DC output. Default is AC output. MEMORY 4 Set unit to memory slot 4 STEP 1 Set unit to step 1 of memory 4 VOLT 90 Set output voltage to 90VDC RAMPUP 0.5 Set the ramp up timer to 0.5sec DELAY 5.0 Set the delay timer to 5 seconds DWELL 120.0 Set the dwell timer to 120 seconds RAMPDOWN 0.5 Set the ramp down timer to 0.5sec VHI 100.0 Voltage high limit set to 100.0V VLO 80.0 Voltage low limit set to 80.0V AHI 2.5 Current high limit set to 2.5A ALO 0.0 Current low limit set to 0.0A (no low limit) Query unit for test data. For a DC test, queried data will be returned in the following format: TD? Memory,Step,Status,Voltage,Current,Power,Timer Table 6: DC Output Program Setup These examples illustrate how the 400XAC can be fully programmed for an automated test setup. Note that all the user was required to adjust in each setup was the connection to the motor and sending a command to change the output function. The 400XAC: An All in One Solution Whether the 400XAC will be used in a laboratory or on a full scale production line for functional testing, its versatile design meets a variety of application requirements. The ability to remotely program multiple test suites, each with multiple output configurations, allows for functional testing of both domestic and international products with one power source. Additionally, the IVI drivers available for the 400XAC series are multi-platform drivers for programming in a multitude of languages (for more information on the IVI platform, visit the IVI Foundation website: http://www.ivifoundation.org/).