Split, Multi and VRF systems. Air conditioning. Residential and Light Commercial

Similar documents
york air-conditioning products Residential & VRF News 2015

Air Conditioning. Light Commercial, Commercial and Industrial

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

systemair Smoke Extract Fans Keep Your Cool: Smoke Extraction with Systemair

FULL DC INVERTER SYSTEMS

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Inverter Air Conditioning for Light Commercial Use

LG Electronics AE Company, Commercial Air Conditioning

FTQ. Daikin Inverter Ducted Heat Pump

ECO-AIR AIR CONDITIONING

HVAC Systems: Overview

ECOCIAT. Domestic hot water heat recovery unit

MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

utopia Split Systems DC Inverter 7kW-14kW G8 5kW-25kW

Cooling kw Heating kw

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

2015 / 16. price list. Airconditioning systems

The Benefits Really Add Up

DUCTED AIR CONDITIONING SOLUTIONS

UDSA - UDSBD unit heater

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

CRAC Precision climate control units for data centres

RPV - RP - RA air handling units

Contents. Part 1 General Information Part 2 Outdoor Units Part 3 Installation Part 4 Troubleshooting 73

Unico Inverter. Unique and efficient.

FTXS. Wall Mount Heat Pump or Cooling Only

Combi Unit Genius. The energy efficient Building Service Centre

Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

-~ available. Power consumption during operation is substantially less than that of lower rated

Shaping the future. For room air conditioners of up to 12 kw (Lot 10) Information brochure for specialists, decision-makers and operators

LG Air Conditioning Solutions COMFORT MADE EASY. COMFORT MADE BEAUTIFUL.

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

technology innovation, comfort for your home. The perfect blend of

Air conditioners Heating & Cooling

Pioneer in sustainability

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Chiller/Heat pumps 30AWH. Reversible. Monobloc inverter

TWE+TTA TWE+TWA T.R.

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

SASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

elcome to the era of the SEER seasonal efficiency Product range

HP switch LP switch Discharge thermo Comp. Surface thermo

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

NEW 3-PIPE ECOi MF2 SERIES

PRODUCT CATALOG. Indoor Units

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Innovent LASER Packaged Fresh Air Conditioning Units

We have been working in an ideal climate for thirty years.

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

- White Paper - Data Centre Cooling. Best Practice

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

SECTION HEAT PUMPS

AIR CONDITIONERS ROOF TOP & UNDERBUNK INSPIRED BY COMFORT NEW RELEASE DOMETIC FRESHJET

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

Introduction To VRF: System Overview, Applications, & Savings Opportunities

ASTACEA4 Inspect complex/central air conditioning systems

Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4)

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

Direct Fresh Air Free Cooling of Data Centres

Ductless Heat Pumps. Gary Nordeen January

Lesson 36 Selection Of Air Conditioning Systems

ZUBA-CENTRALTM. Heating & Cooling. Evolved. HEATING AND AIR CONDITIONING FOR WHOLE-HOME, YEAR-ROUND COMFORT

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Daikin Altherma hybrid heat pump. The natural combination

U-MATCH Air Conditioners. Service Manual. T1/R410a/50Hz

FBQ. DC Duct Heat Pump or Cooling Only

FCQ. Roundflow Cassette Heat Pump or Cooling Only

Company Presentation

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

USER S MANUAL HSC-24A

The compact unit series

Appendix - Controllers 179

LG AIR CONDITIONING SYSTEMS

IR410AI. The flexible solution. Simple, one touch control

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

FHQ. Ceiling Suspended Heat Pump or Cooling Only

Screw Compressors 11-22kW

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Models Utopia ES Utopia IVX Utopia DC Inverter Utopia Fixed Speed Utopia Centrifugal

High-efficient gas boiler CompactGas

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

Fan Coil Units. Fan coil units with brushless DC motor with inverter. your comfort. our world. » Up to 70% energy saving with BLDC motor technology

Modular Data Center Cooling. Ultra High Efficiency. Oasis Optimum DCIE

Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort

Residential and Light Commercial Air Conditioning Systems

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Transcription:

Split, Multi and VRF systems ir conditioning Residential and Light Commercial

Systemair Trust We consider your trust in us as a supplier an important goal. It is always included in our work on all levels and in all areas whether it is a question of cooperation, quality, deliveries or documentation. This catalogue is of course a part of this work. With this catalogue, which features products of air conditioning, we want to give you as a customer a general overview of what Systemair can offer within this field. More detailed information is available in our Online catalogue at www.systemair.com and as downloadable software. Systemair s range of fans, air distribution products and accessories also appears in our printed main catalogue. Our product development leads the field - latest technologies in unitdesign, fans, motors, heat recovery, chillers, fan coils,... interact to give high efficiency and with that low power consumption. Systemair has grown each year since the start and we aim to continue with this trend. Systemair strives to be a reliable supplier of quality products. We help our customers to focus on their own business. Reliable deliveres give the customers greater possibilities to quickly complete a job, and move on to the next project. t Systemair we call this Trust. Systemair 2013. Systemair reserves the right to make technical changes. For updated documentation, please refer to www.systemair.com

Content 3 Content Systemair 4 Product range 6 pplication 8 SPLIT systems 10 Introduction to SYSPLIT systems 12 SYSPLIT WLL EVO 14 SYSPLIT WLL INV 16 SYSPLIT MULTI EVO 18 SYSPLIT CSSETTE EVO 22 SYSPLIT CEILING EVO 24 SYSPLIT DUCT EVO 26 SYSPLIT DUCT BIG 28 VRF systems 30 Introduction to SYSVRF systems 32 SYSVRF Mini Heat Pump outdoor units 34 SYSVRF 2Pipe/Heat Pump outdoor units 36 SYSVRF 3Pipe/Heat Recovery outdoor units 40 SYSVRF WLL indoor units 46 SYSVRF CSSETTE MINI indoor units 48 SYSVRF CSSETTE indoor units 50 SYSVRF CEILING indoor units 52 SYSVRF DUCT indoor units 54 SYSVRF DUCT HP indoor units 56 SYSVRF HRV ventilation units 58 SYSCONTROL HU connection kits 60 SYSVRF selection software 61 SYSCONTROL local and centralized controllers 62 piping joints 64

4 Systemair Systemair worldwide Skinnskatteberg, Sweden: Systemair B, the Systemair group head office is in Skinnskatteberg, Sweden. The production is virtually fully automated with modern machinery featuring advanced computer support. lso located here is the company s most advanced test installation for measuring technical data. Klockgården, Sweden: Systemair s small air handling units are manufactured at Klockgården in Skinnskatteberg. Frico s central warehouse of approximately 8000 m 2 is also located here. Windischbuch, Germany: Production facility for fans and modular air handling units, specialized on engineered products (e.g. tunnel and jet fans). Distribution center. Langenfeld, Germany: Production of air curtains. Hässleholm, Sweden: VEB is the leading European manufacturer of electric duct heaters. Production of heating and cooling coils, electric and water based. Ukmerge, Lithuania: Production of smaller air handling units with energy recovery systems. Maribor, Slovenia: Specialized in centrifugal smoke extract fans, EN certified. Hasselager, Denmark: Production of modular air handling units. Dal Eidsvoll, Norway: Production of air handling units.

Systemair 5 Quality: Systemair is certified in accordance with ISO 9001; ISO 14001 and TEX. Our research and development laboratories are one of the most modern in Europe; measurements are made in accordance with international standards like MC and ISO. Save energy, lower running cost! Our label Green Ventilation features products with a high energy saving potential. ll products labelled with Green Ventilation combine energy economy with energy efficiency. Kansas City, US Bouctouche, Canada Dal, Eidsvoll, Norway Hasselager, Denmark Waalwijk, Netherlands Windischbuch, Germany Barlassina, Italy Madrid, Spain Skinnskatteberg, Sweden Hässleholm, Sweden Ukmerge, Lithuania Langenfeld, Germany Bratislava, Slovakia Maribor, Slovenia Istanbul, Turkey New Delhi, India Hyderabad, India Kuala Lumpur, Malaysia Bratislava, Slovakia: The factory in Bratislava manufactures air distribution products and EN certified fire and smoke dampers. Kuala Lumpur, Malaysia: Production and marketing of products for Tunnel and garage ventilation. Madrid, Spain: Production of air handling units for the southern European market. Hyderabad, India: Production if air distribution products. New Delhi, India: The factories in New Delhi and Noida manufacture grilles and diffusers. Barlassina, Italy: Our factory in Italy, Systemair, develops and manufactures a wide range of air conditioner. Bouctouche, Canada: Our main North merican production facility of air handling units and inline fans for commercial and residential applications is located in Bouctouche. Kansas City, US: Production of fans for the US market. Istanbul, Turkey: Systemair-HSK is Turkey s leading manufacturer of air handling units. Waalwijk, Netherlands: Holland Heating is Netherlands leading manufacturer of air handling units.

6 Product range Product range Systemair has an extensive range of ventilation products: fans including smoke extract, tunnel and car park fans, explosion proof fans, air handling units from large central units to small residential units with energy recovery, air distribution products and fire dampers. These products are installed in a variety of locations, including homes, offices, healthcare premises, shops, industrial buildings, tunnels, parking garages, training facilities, sports centres etc. Fans Systemair has the wider range of fans for use in different applications. Our range includes any type of fans, from circular ducts hystorical product boxed up to those of extraction, axial, and explosion-proof for the extraction of fumes. ll products listed above are made in different dimensions from 100 mm in diameter to fans of large size for tunnel. ll our fans are designed to meet the strict requirements, easy to use, high quality and durability. Duct fans Duct fans for circular duct installation. Centrifugal fans Centrifugal supply single fans. Rectangular duct fans Duct fans with rectangular connection. Square duct fans For different applications, there are models for ambient with high temperature. xial fans xial fans for duct or wall application. Roof fans Roof fans with circular or square connection. Explosion proof fans Explosion proof fans in duct, roof or wall design. Jet xial Fans Jet xial Fans for car park, tunnels and air overpression. High temperature fans Systemair provides high fire resistance fans till 600 C/2 hours.

Product range 7 ir handling units Systemair produces a wide range of air handling units for several applications, from small office to large industrial building. ll range is been developped to satisfy strict needs of low energy consumption. Fire and smoke dampers Smoke extract fans High efficient fans to extract the combustion smoke. Fire & smoke dampers Dampers that reduce the spread of smoke and fire. Residential ventilation Complete energy-efficient air handling units with heat recovery and built in control systems. Designed to be mounted over the cooker, on walls or horizontally in attics. Residential units For homes with living areas of 60-320 m 2. Cooker hoods Ideal for capturing odours even at low airflows. ir distribution products The range also includes a wide selection of air distribution products and accessories. Supply, extract & transfer devices For mounting in ceilings or walls. Nozzle diffusers Optimum flexibility and comfort in air distribution for rooms. ir Conditioning The strengh point of Systemair ir Conditioning products is a wide range with several options and accessories: chiller, water terminals, close control etc.

pplications Schools In buildings for school, the load to be disposed is variable during the day due to the presence of people only for some periods, thus it is mandatory to control the users requirements during daily plant use. Systemair offers a wide range of equipment suitable for this purpose, the fan coils with EC motors allow to obtain the required flexibility. Offices In buildings for tertiary application, the air conditioning and the ventilation are necessary during the day. The heat loads to be removed are generally generated by people present, from the lighting system, from solar radiation and by machines. Normally it is necessary the use of chillers, Heat Pump to produce cold and/or hot water to be sent to hydronic (fan coils, cassettes, ducted) to obtain an optimum air conditioning of offices.

Commercial buildings Normally the number of people varies continuously; the optimal solution would be to use machinery for the conditioning with variable flow and with constant monitoring of concentration of pollutants (VOC and CO 2 ). Systemair products can easily meet the plantʼs requirement. Industry Industrial plants generate a large amount of heat that must be dissipated in the appropriate way. Systemair offers a wide range of products (chillers from 20 kw to 1.680 kw) that can be readily integrated industrial installation. The chiller can be used both for air conditioning and for the cooling equipment process (production of chilled water up to -10 C). Hotels In the hotel rooms, it is needed a high level of comfort with the minimum impact with respect to the noise level. Systemair ducted products equipped with EC motors fully comply with requirements efficiency, cooling capacity and sound impact, required by this type of installations.

SYSPLIT

Split and Multi systems 11 SYSPLIT air conditioners Systemair: residential and light commercial split systems The SYSPLIT air conditioner range are specifically designed for small to medium sized areas, offering the end user improved comfort and reducing drastically the power consumption. The expanded range of SYSPLIT air conditioners is of superior performance and quality, providing more choice for customers. Our innovative products offer the ideal solution when you need quiet and efficient room air conditioning to create a comfortable environment. In addition to Single Split systems, Systemair also offers the SYSPLIT MULTI an advanced range of inverter Heat Pump Multi Split Systems with up to 5 indoor units of different types that can be connected. ll SYSPLIT inverter systems utilise the non-ozone depleting R410 refrigerant, which gives increased system performance, increased energy-efficiency and improved heat transfer, which results in smaller pipe sizes and more compact indoor units. The latest generation of SYSPLIT air conditioners are among the most technically advanced and energyefficient systems available today. SYSPLIT Single and Multi systems SYSPLIT WLL EVO 14 SYSPLIT CSSETTE EVO 22 SYSPLIT WLL INV 16 SYSPLIT CEILING EVO 24 SYSPLIT MULTI EVO 18 SYSPLIT DUCT EVO 26 SYSPLIT MULTI combination 20 SYSPLIT DUCT HT 28

12 Split and Multi systems Ecodesign regulation ErP Directive 2009/125 The new regulation have been adopted by the European Parliament to achieve the goals to reduce the power consumption in Europe related to air conditioning business and other home appliance as well as air-to-water heat pump, air handling, ventilation etc. With its strategic plan called 20/20/20, Europe aims to reduce the CO 2 emissions by 20%, using 20% more renewable energy and consuming 20% less primary energy by 2020. In order to facilitate the achievement of these objectives, EU issued the ErP Directive that specifies the eco-design requirements for placing on the market the energy-using products. For split air conditioners with power less than 12 kw, the minimum requirements are based on a new index of seasonal efficiency and on the sound power level as shown in the table below: /C <6 kw /C 6-12 kw SEER SCOP SEER SCOP SEER/SCOP min. 4,6 3,8 4,3 3,8 L w indoor max. 60 db() 65 db() L w outdoor max. 65 db() 70 db() 20% less emissions of CO 2 gas 20% more use of renewable energy 20% less use of primary energy Measuring the performance in real conditions The European Union requires the application of objective metrics for measuring performance in order to establish the minimum requirements and provide customers with information regarding the performance of air conditioning useful for their purchase. The methodology used up to 2012 and based on the efficiency rating (EER) presents a significant difference between the predicted and actual performance. For this reason a more accurate method has beed designed: the seasonal efficiency ratio (SEER). mong the most significant changes it includes the introduction of different operating temperatures for cooling and heating, the possibility of use of energy both at partial load and full load and power usage in standby and off mode. Considering that most systems operate mostly in partload conditions, the new methodology will allow to assess better the performance of a unit in real conditions.

Split and Multi systems 13 New energy classification New energy classification in force from 1 January 2013 The transition to the concept of seasonal efficiency involves the development of a completely new energy label which shows the energy class based on the values of SEER and SCOP and the main characteristics of the product such as the sound power level of the indoor and outdoor units. Energy efficiency in heating is presented with three different values according to the climate where the product is installed. For the manufacturer of the product is mandatory to indicate the values for the Temperate climate ( verge heating value), those of the other two climates are optional. The data and energy efficiency classes are declared in accordance with EN14825. The energy class shown in the new label, both in cooling and in heating, can not be compared to the energy class that had the old energy label as the latter was based on specific indices (EER and COP) and not on seasonal indices SEER and SCOP. The energy efficiency classes for split air conditioners are shown in the table below: Energy Efficiency Class SEER SCOP +++ SEER 8,50 SCOP 5,10 ++ 6,10 SEER < 8,50 4,60 SCOP < 5,10 + 5,60 SEER < 6,10 4,00 SCOP < 4,60 5,10 SEER < 5,60 3,40 SCOP < 4,00 B 4,60 SEER < 5,10 3,10 SCOP < 3,40 C 4,10 SEER < 4,60 2,80 SCOP < 3,10 D 3,60 SEER < 4,10 2,50 SCOP < 2,80 E 3,10 SEER < 3,60 2,20 SCOP < 2,50 F 2,60 SEER < 3,10 1,90 SCOP < 2,20 G SEER < 2,60 SCOP < 1,90

14 Hi-wall Inverter High efficiency Split Hi-wall Inverter High efficiency Split SYSPLIT WLL EVO HP Features SYSPLIT WLL EVO combines cutting-edge technology with elegant and smooth shapes which can fit any interior decor, providing seasonal performance up to 7,0 (SEER). dvanced DC inverter control for the compressor, outdoor fan motor and indoor fan motor. Cooling and heating operation down to -15 C outdoor temperature assures an operation all year round. Self-diagnosis function continuosly monitors the operation of the air conditioner and protects the system. Refrigerant leakage detection can prevent the compressor being damaged by refrigerant leakage or compressor overload. The cold catalyst filter effectively decomposes volatile compounds and it has anti-bacteria effect. It is washable and maintains the effect for long time. With Turbo mode the unit will run with the ultra-high speed for 20 minutes, reaching more quickly the setpoint temperature. Hydrophylic aluminium fins of the indoor units improve the heat exchange efficiency in cooling and heating mode. Power factor capacitors included in the outdoor unit allow an active PF around 97%. Infrared remote control SYSCONTROL RM 52 (standard) With the uto-restart function the unit resumes with the same settings before the electric power failure. Environment friendly R410 refrigerant. Infrared remote control SYSCONTROL RM 52 included. Dimensions SYSPLIT WLL IN SYSPLIT WLL OUT B D ir inlet C B ir inlet C E ir outlet Model 09 12 18 24 835 835 990 1.186 B 198 198 218 258 C 280 280 315 340 Model 09 12 18 24 780 810 810 845 B 540 558 558 700 C 250 310 310 320 D 549 549 549 560 E 276 325 325 335

Hi-wall Inverter High efficiency Split 15 Technical features Model Indoor unit SYSPLIT WLL IN 09 EVO HP Q IN 12 EVO HP Q IN 18 EVO HP Q IN 24 EVO HP Q Model Outdoor unit SYSPLIT WLL OUT 09 EVO HP Q OUT 12 EVO HP Q OUT 18 EVO HP Q OUT 24 EVO HP Q rt. no. Indoor unit 314017 314018 314019 314167 rt. no. Outdoor unit 314004 314005 314006 314007 Refrigerant R410 Power supply V/Ph/Hz 220-240/1/50 Cooling capacity kw 2,78 (1,28~3,54) 3,66 (1,31~4,76) 5,28 (1,93~6,23) 6,45 (2,22~7,42) Power consumption W 803 (113~1.360) 1.071 (99~1.830) 1.670 (147~2.390) 2.147 (195~2.850) Operating current 3,49 (0,49~5,91) 4,66 (0,43~7,96) 7,26 (0,64~10,41) 9,45 (0,85~12,4) EER 3,47 3,42 3,16 2,97 SEER 6,5 7,0 6,4 6,2 Energy label cooling ++ ++ ++ ++ Heating capacity kw 2,88 (1,27~3,56) 3,75 (1,03~4,95) 5,57 (1,20~6,76) 7,33 (1,57~9,09) Power consumption W 627 (160~1.270) 991 (162~1.770) 1.495 (231~2.490) 2.232 (284~3.240) Operating current 2,73 (0,7~5,53) 4,31 (0,7~7,69) 6,50 (1,0~10,81) 9,70 (1,23~14,11) COP 4,59 3,78 3,73 3,28 SCOP (verage) 4,0 4,1 4,0 4,0 Energy label heating + + + + Indoor Unit ir flow rate (H/M/L) m 3 /h 650/530/400 700/580/500 1.250/980/820 1.450/1.300/1.200 Sound pressure level (H/M/L) db() 43/38/28 43/37/31 48/41/35 49/46/42 Sound power level (H) db() 56 57 60 63 Dimensions LxWxH mm 835x198x280 835x198x280 990x218x315 1.186x258x340 Packing LxWxH mm 910x270x355 910x270x335 1.065x300x400 1.265x420x340 Net/gross weight kg 8/10 9/11,5 12/15 17/22 Outdoor Unit Compressor Type Rotary Twin-rotary Sound pressure level (H) db() 45 45 47 52 Sound power level (H) db() 62 62 64 69 Dimensions LxWxH mm 780x250x540 810x310x558 810x310x558 845x320x700 Packing LxWxH mm 910x335x585 930x400x615 930x400x615 965x395x755 Net/gross weight kg 28/30 30,5/33 37/39 47/50,5 Liquid mm (inch) 6,35 (1/4 ) 6,35 (1/4 ) 6,35 (1/4 ) 9,52 (3/8 ) Piping diameters Gas mm (inch) 9,52 (3/8 ) 9,52 (3/8 ) 12,7 (1/2 ) 15,9 (5/8 ) Drainage mm 16 16 16 16 Max. input corrent 9,0 11,5 11,5 13,5 Maximum lenght of the line m 25 25 30 30 Maximum height difference m 10 10 20 20 Indoor temperature C +17 +32 cooling / heating 0 +30 Outdoor temperature C -15... +50 cooling / heating -15... +30 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27 C DB, 19 C WB 35 C DB 5 m 0 m Heating mode 20 C DB, 19 C WB 7 C DB, 6 C WB 5 m 0 m Seasonal efficiency according to EN 14825. The sound pressure value may vary depending on ambient conditions.

16 Hi-wall Inverter Split Hi-wall Inverter Split SYSPLIT WLL INV HP Features SYSPLIT WLL INV are the most affordable and reliable solution for small offices and residential premises. High efficient DC inverter control provides accurate regulation of the room temperature. Stylish appearance with big LCD showing all main settings of the air conditioner. Outdoor units are equipped with valve protection cover. Self-diagnosis function continuosly monitors the operation of the air conditioner and protect the system. Refrigerante leakage detection can prevent the compressor being damaged by refrigerant leakage or compressor overload. The cold catalyst filter effectively decomposes volatile compounds and it has anti-bacteria effect. It is washable and maintains the effect for long time. With Turbo mode the unit will run with the ultra-high speed for 20 minutes to reach more quickly the set-point temperature. Hydrophylic aluminium fins of the indoor units improve the heat exchange efficiency in cooling and heating mode. Infrared remote control SYSCONTROL RM 52 (standard) Power factor capacitors included in the outdoor unit allow an active PF around 97%. With the uto-restart function the unit resumes with the same settings before the electric power failure. Environment friendly refrigerant R410. Infrared remote control SYSCONTROL RM 52 included. Dimensions SYSPLIT WLL IN SYSPLIT WLL OUT B D ir inlet C B ir inlet C E ir outlet Model 09 12 18 24 800 800 940 1.045 B 188 188 205 235 C 275 275 275 315 Model 09 12 18 24 780 810 810 845 B 540 558 558 700 C 250 310 310 320 D 549 549 549 560 E 276 325 325 335

Hi-wall Inverter Split 17 Technical features Model Indoor unit SYSPLIT WLL IN 09 INV HP Q IN 12 INV HP Q IN 18 INV HP Q IN 24 INV HP Q Model Outdoor unit SYSPLIT WLL OUT 09 INV HP Q OUT 12 INV HP Q OUT 18 INV HP Q OUT 24 INV HP Q rt. no. Indoor unit 314163 314164 314165 314166 rt. no. Outdoor unit 314000 314001 314002 314003 Refrigerant R410 Power supply V/Ph/Hz 220-240/1/50 Cooling capacity kw 2,64 (1,30~3,22) 3,22 (1,41~4,29) 4,98 (1,91~5,90) 6,45 (2,18~7,09) Power consumption W 790 (144~1.240) 1.000 (139~1.650) 1.550 (157~2.270) 2.000 (204~2.730) Operating current 3,4 (0,63~5,39) 4,4 (0,60~7,17) 6,7 (0,68~9,87) 8,7 (0,89~11,87) EER 3,34 3,22 3,21 3,23 SEER 5,6 5,6 6,1 5,9 Energy label cooling + + ++ + Heating capacity kw 2,93 (1,01~3,45) 3,66 (0,98~4,54) 5,28 (1,27~6,23) 6,74 (1,60~8,65) Power consumption W 730 (175~1.230) 1.010 (177~1.620) 1.420 (191~2.220) 1.810 (293~3.090) Operating current 3,2 (0,76~5,35) 4,4 (0,77~7,04) 6,2 (0,83~9,65) 7,9 (1,27~13,43) COP 4,01 3,63 3,71 3,72 SCOP (verage) 3,8 3,8 3,8 3,8 Energy label heating Indoor Unit ir flow rate (H/M/L) m 3 /h 620/540/440 630/550/430 730/480/400 1.150/1.050/900 Sound pressure level (H/M/L) db() 41/38/31 43/40/31 41/33/31 49/47/41 Sound power level (H) db() 57 57 57 63 Dimensions LxWxH mm 800x188x275 800x188x275 940x205x275 1.045x235x315 Packing LxWxH mm 865x265x350 865x265x350 1.015x265x350 1.135x395x350 Net/gross weight kg 7,5/9,5 7,5/9,5 9/12,5 12,5/15,5 Outdoor Unit Compressor Type Rotary Twin-rotary Sound pressure level (H) db() 46 46 48 51 Sound power level (H) db() 63 63 65 68 Dimensions LxWxH mm 780x250x540 780x250x540 760x285x590 845x320x700 Packing LxWxH mm 910x335x585 910x335x585 887x355x645 965x395x755 Net/gross weight kg 28/30 28/30 34,5/37 47/50 Liquid mm (inch) 6,35 (1/4 ) 6,35 (1/4 ) 6,35 (1/4 ) 9,52 (3/8 ) Piping diameters Gas mm (inch) 9,52 (3/8 ) 9,52 (3/8 ) 12,7 (1/2 ) 15,9 (5/8 ) Drainage mm 16 16 16 16 Max. input current 9,0 11,5 12,5 13,5 Maximum lenght of the line m 20 20 20 25 Maximum height difference m 8 8 8 10 Indoor temperature C +17 +32 cooling / heating 0 +30 Outdoor temperature C 0... +50 cooling / heating -15... +30 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27 C DB, 19 C WB 35 C DB 5 m 0 m Heating mode 20 C DB, 19 C WB 7 C DB, 6 C WB 5 m 0 m Seasonal efficiency according to EN 14825. The sound pressure value may vary depending on ambient conditions.

18 Multi-split Inverter High efficiency Multi-split Inverter High efficiency SYSPLIT MULTI EVO HP Features SYSPLIT MULTI EVO are ideal and flexible solution for providing quiet and efficient air conditioning for 2 to 5 areas from a single outdoor unit. SYSPLIT MULTI outdoor units are compatible with SYSPLIT WLL EVO, CSSETTE EVO and DUCT EVO indoor units. DC inverter technology for precise temperature control and a low start-up current. Robust and reliable structure, cabinet made of zinc steel sheet. Outdoor units are equipped with valve protection cover. Twin-rotary compressors assure high efficient operation, minimal vibration and low noise level. ll indoor units are equipped with DC Inverter fan motor. Hydrophylic aluminium fins improve the heat exchange efficiency reducing the defrosting cycle time. Cooling and heating operation down to -15 C outdoor temperature assures an operation all year round. Power factor capacitors included in the unit allow an active PF around 97%. With the uto-restart function the unit resumes with the same settings before the electric power failure. Environment friendly refrigerant R410. Dimensions SYSPLIT MULTI B E C D Model 14 18 21 28 36 845 845 845 900 990 B 700 700 700 860 965 C 320 320 320 315 345 D 560 560 560 590 624 E 335 335 335 333 366

Multi-split Inverter High efficiency 19 Technical features Model SYSPLIT MULTI2 14 EVO HP Q MULTI2 18 EVO HP Q MULTI3 21 EVO HP Q MULTI4 28 EVO HP Q MULTI5 36 EVO HP Q rt. no. Outdoor unit 314011 314012 314013 314014 314015 Refrigerant R410 Power supply V/Ph/Hz 220-240/1/50 Cooling capacity kw 4,11 5,26 6,16 8,20 10,56 Power consumption W 1.260 1.600 1.900 2.470 3.280 Operating current 5,7 7,0 8,3 11,2 14,6 EER 3,26 3,29 3,24 3,32 3,22 SEER 6,1 6,3 6,4 6,4 5,7 Energy label cooling ++ ++ ++ ++ + Heating capacity kw 4,68 6,15 6,74 9,08 12,31 Power consumption W 1.450 1.700 1.750 2.440 3.400 Operating current 6,5 7,4 7,6 11,1 15,3 COP 3,23 3,62 3,85 3,72 3,62 SCOP (verage) 4,0 4,2 4,1 3,8 3,8 Energy label heating + + + Outdoor Unit Compressor Type Rotary Twin-rotary Twin-rotary Twin-rotary Twin-rotary Sound pressure level (H) db() 45 46 47 53 51 Sound power level (H) db() 62 63 64 70 68 Dimensions LxWxH mm 845x320x700 845x320x700 845x320x700 900x315x860 990x345x965 Packing LxWxH mm 965x395x755 965x375x755 965x395x755 1.043x395x915 1.120x435x1.100 Net/gross weight kg 44/47 48/52 50/54 65/69 80/91 Piping diameters Liquid inch 2x 6,35 (1/4 ) 2x 6,35 (1/4 ) 3x 6,35 (1/4 ) 4x 6,35 (1/4 ) 5x 6,35 (1/4 ) Gas inch 2x 9,52 (3/8 ) 2x 9,52 (3/8 ) 3x 9,52 (3/8 ) 4x 9,52 (3/8 ) 5x 9,52 (3/8 ) Max. input current 11,0 14,5 15,0 17,0 22,0 Maximum lenght all lines m 30 30 45 60 75 Maximum lenght of the line m 20 20 25 30 30 Maximum height difference OU higher than IU/ OU lower than IU m 10/15 10/15 10/15 10/15 10/15 Outdoor temperature C -15... +50 cooling / heating -15... +24 Rated performance at 100% of combination. For combination exceeding 100% the cooling and heating capacities of the indoor units will be proportionally reduced. Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27 C DB, 19 C WB 35 C DB 5 m 0 m Heating mode 20 C DB, 19 C WB 7 C DB, 6 C WB 5 m 0 m Seasonal efficiency according to EN 14825. The sound pressure value may vary depending on ambient conditions.

20 Multi-split indoor units Indoor units for SYSPLIT MULTI EVO Wall mounted indoor unit SYSPLIT WLL IN EVO HP Q Infrared remote control SYSCONTROL RM 52 (standard) Model indoor unit SYSPLIT WLL IN 07 EVO HP Q IN 09 EVO HP Q IN 12 EVO HP Q IN 18 EVO HP Q rt. no. Indoor unit 314016 314017 314018 314019 Cooling capacity kw 2,02 2,60 3,47 4,91 Heating capacity kw 2,31 2,89 3,76 5,20 Power consumption W 24 24 24 62 Operating current 0,11 0,11 0,11 0,28 ir flow rate (H/M/L) m 3 /h 650/530/400 650/530/400 700/580/500 1.250/980/820 Sound pressure level (H/M/L) db() 43/38/28 43/38/28 43/37/31 48/41/35 Liquid inch 6,35 (1/4 ) 6,35 (1/4 ) 6,35 (1/4 ) 6,35 (1/4 ) Piping diameters Gas inch 9,52 (3/8 ) 9,52 (3/8 ) 9,52 (3/8 ) 12,7 (1/2 ) Drainage mm 16 16 16 16 Dimensions LxWxH mm 835x198x280 835x198x280 835x198x280 990x218x315 Unit weight kg 8 8 9 12 Cassette indoor unit SYSPLIT CSSETTE IN EVO HP Q Infrared remote control SYSCONTROL RM 52 (standard) Model indoor unit SYSPLIT CSSETTE 07 EVO HP Q 09 EVO HP Q 12 EVO HP Q M 18 EVO HP Q Model panel unit SYSPNEL CSSETTE MINI SPLIT MINI SPLIT MINI SPLIT MINI SPLIT rt. no. Indoor unit 314020 314021 314028 314171 rt. no. Panel unit 314032 314032 314032 314032 Cooling capacity kw 2,02 2,60 3,47 5,20 Heating capacity kw 2,31 2,89 3,76 5,20 Power consumption W 40 40 102 102 Operating current 0,18 0,18 0,44 0,44 ir flow rate (H/M/L) m 3 /h 580 580 800 800 Sound pressure level (H) db() 32 32 37 42 Liquid inch 6,35 (1/4 ) 6,35 (1/4 ) 6,35 (1/4 ) 6,35 (1/4 ) Piping diameters Gas inch 9,52 (3/8 ) 9,52 (3/8 ) 9,52 (3/8 ) 12,7 (1/2 ) Drainage mm 25 25 25 25 Dimensions LxWxH mm 570(647)x570(647)x260(50) Unit weight kg 16(2,5) 16(2,5) 16(2,5) 18(2,5) Duct indoor unit SYSPLIT DUCT IN EVO HP Q Wired controller SYSCONTROL WC 90 (standard) Model indoor unit SYSPLIT DUCT 07 EVO HP Q 09 EVO HP Q 12 EVO HP Q M 18 EVO HP Q rt. no. Indoor unit 314024 314025 314026 314172 Cooling capacity kw 2,02 2,60 3,47 5,20 Heating capacity kw 2,31 2,89 3,76 5,78 Power consumption W 30 30 40 107 Operating current 0,13 0,13 0,17 0,48 ir flow rate (H/M/L) m 3 /h 600 600 680 1.000 External static pressure (H) Pa 40 40 40 70 Sound pressure level (H) db() 38 38 40 42 Liquid inch 6,35 (1/4 ) 6,35 (1/4 ) 6,35 (1/4 ) 6,35 (1/4 ) Piping diameters Gas inch 9,52 (3/8 ) 9,52 (3/8 ) 9,52 (3/8 ) 12,7 (1/2 ) Drainage mm 25 25 25 25 Dimensions LxWxH mm 700x635x210 700x635x210 700x635x210 920x635x210 Unit weight kg 19,5 19,5 18 23

Multi-split combination 21 Multi combination table SYSPLIT MULTI EVO SYSPLIT MULTI2 14 EVO HP Q One Unit Two Unit 7 7+7 9 7+9 12 7+12 18 9+9 SYSPLIT MULTI2 18 EVO HP Q One Unit Two Unit 7 7+7 9 7+9 12 7+12 18 7+18 9+9 9+12 12+12 SYSPLIT MULTI3 21 EVO HP Q One Unit Two Unit Three Unit 7 7+7 7+7+7 9 7+9 7+7+9 12 7+12 7+7+12 18 7+18 7+9+9 9+9 7+9+12 9+12 9+9+9 12+12 SYSPLIT MULTI4 28 EVO HP Q One Unit Two Unit Three Unit Four Unit 7 7+7 7+7+7 7+7+7+7 9 7+9 7+7+9 7+7+7+9 12 7+12 7+7+12 7+7+7+12 18 7+18 7+9+9 12+12+12 9+9 7+9+12 7+7+9+12 9+12 7+9+18 7+9+9+9 9+18 7+7+18 9+9+9+9 12+12 9+9+9 7+7+9+9 12+18 9+9+12 18+18 9+12+12 7+12+12 SYSPLIT MULTI5 36 EVO HP Q One Unit Two Unit Three Unit Four Unit Five Unit 7 7+7 7+7+7 7+7+7+7 7+7+7+7+7 9 7+9 7+7+9 7+7+7+9 7+7+7+7+9 12 7+12 7+7+12 7+7+7+12 7+7+7+7+12 18 7+18 7+7+18 7+7+7+18 7+7+7+7+18 9+9 7+9+9 7+7+9+9 7+7+7+9+9 9+12 7+9+12 7+7+9+12 7+7+7+9+12 9+18 7+9+18 7+7+9+18 7+7+7+12+12 12+12 7+12+12 7+7+12+12 7+7+9+9+9 12+18 7+12+18 7+7+12+18 7+7+9+9+12 18+18 7+18+18 7+9+9+9 7+9+9+9+9 9+9+9 7+9+9+12 7+9+9+9+12 9+9+12 7+9+9+18 9+9+9+9+9 9+9+18 7+9+12+12 9+12+12 7+9+12+18 9+12+18 7+12+12+12 12+12+12 9+9+9+9 12+12+18 9+9+9+12 9+9+9+18 9+9+12+12 9+12+12+12 * In case combination of indoor units exceeds the nominal capacity of outdoor unit the capacity of each indoor units is smaller.

Cassette Inverter High efficiency Split Cassette Inverter High efficiency Split SYSPLIT CSSETTE EVO HP Features SYSPLIT CSSETTE EVO air conditioners are ideal solution for creating a comfortable climate in the office and shopping centers in all rooms designed with false ceilings. Dimensions SYSPLIT CSSETTE size 12-18 840 (Body) Infrared remote controller SYSCONTROL RM 52 included; Wired remote SYSCONTROL WC 90 available as accessory. SYSPLIT OUTDOOR size 12 to 24 24 to 60 size 36 to 60 H H E E C C D D 647(Panel) F F 570(Body) Model Hook 50 Ceiling 600 Outlet Inlet Outlet B Panel B 12 18 24 36 48 60 760 845 900 938 938 938 530 560 634 634 634 335 333 404 404 404 590 C 290 E C D Nut B D 315 360 355 448 448 448 368 F H Body H BB BB 780 (Hook-location) 840 (Body) 950 (Panel) 545(Hook-location) H 840 (Body) 950 (Panel) 680 (Hook-location) 570(Body) 647(Panel) 523(Hook-location) H H 780 (Hook-location) 840 (Body) size 950 (Panel) Wired controller SYSCONTROL WC 90 rt. no. 314139 (optional) Infrared remote control SYSCONTROL RM 52 (standard) 950 (Panel) 680 (Hook-location) dvanced DC inverter control for the compressor, outdoor fan motor and indoor fan motor. vailable with 2 different sizes: 57x57 for models 12 and 18, 84x84 for models 24 to 60. The 360 round flow panel assures an optimal air distribution and comfort in the room. Special aerodynamic shape of the fan and the geometry of the blades ensure low noise from the air conditioner. Washable air filter included in the panel greatly simplifies the maintenance. The panel is equipped with an interactive LCD. Built-in drain pump with lift height up to 500 mm for models 12-18, and up to 750 mm for models 24 to 60. Fresh air intake can fufill air quality requirements and enhance occupants comfort. uto-restart after electric power failure. Environment friendly refrigerant R410. 260mm >2500 Model 12 18 24 36 48 60 E 270 312 302 368 368 260 260 245 245 287 287 F 285 320 315 392 392 392 H >280 >280 >260 >260 >330 >330 H 590 700 860 1.369 1.369 1.369 >2500 mm H 22 Outlet Inlet Outlet

Cassette Inverter High efficiency Split 23 Technical features Model Indoor unit Model Outdoor unit Model Panel unit SYSPLIT CSSETTE SYSPLIT OUTDOOR SYSPNEL 12 EVO HP Q 12 EVO HP Q CSSETTE MINI SPLIT 18 EVO HP Q 18 EVO HP Q CSSETTE MINI SPLIT 24 EVO HP Q 24 EVO HP Q CSSETTE EVO 36 EVO HP Q 36 EVO HP Q CSSETTE EVO 36 EVO HP Q 36 EVO HP R CSSETTE EVO 48 EVO HP Q 48 EVO HP R CSSETTE EVO 60 EVO HP Q 60 EVO HP R CSSETTE EVO rt. no. Indoor unit 314028 314029 314030 314031 314031 314033 314035 rt. no. Outdoor unit 314056 314057 314058 314059 314060 314062 314063 rt. no. Panel 314032 314032 314034 314034 314034 314034 314034 Refrigerant R410 Power supply V/Ph/Hz 220-240/1/50 380-420/3/50 Cooling capacity kw 3,52 5,28 7,04 10,54 10,56 14,06 16,11 Power consumption W 1.090 1.640 2.100 3.100 3.200 4.380 5.020 Operating current 4,7 7,1 9,1 13,5 5,5 7,6 8,7 EER 3,23 3,22 3,35 3,40 3,30 3,21 3,21 SEER 5,6 5,6 6,5 6,0 5,6 - - Energy label cooling + + ++ + + - - Heating capacity kw 4,10 5,86 7,61 11,73 11,74 16,40 19,06 Power consumption W 1.070 1.580 2.030 3.250 3.130 4.420 5.280 Operating current 4,6 6,9 8,8 14,1 5,4 7,6 9,1 COP 3,83 3,71 3,75 3,61 3,75 3,71 3,61 SCOP (verage) 3,8 3,8 3,8 3,8 3,8 - - Energy label heating - - Indoor Unit ir flow rate (H/M/L) m 3 /h 800/710/560 1580/1.200 /1.000 1.950/1.650/1.400 2.250/1.850/1.650 Sound pressure level (H) db() 37 42 45 48 48 50 50 Sound power level (H) db() 54 59 62 65 65 67 67 Dimensions (Panel) LxWxH Packing (Panel) LxWxH Net/gross (Panel) weight mm mm kg 570(647)x570(647) x260(50) 655(715)x655(715) x290(123) 16(2,5)/ 19(4,5) 18(2,5)/ 21(4,5) 840(950)x840(950)x245(55) 900(1.035)x900(1.035)x265(90) 24(5)/ 28(8) 840(950)x840(950) x287(55) 900(1.035)x900(1.035) x292(90) 26,5(5)/30,5(8) 29(5)/33(8) 31(5)/34(8) Outdoor Unit Compressor Type Rotary Rotary Twin-rotary Twin-rotary Twin-rotary Twin-rotary Twin-rotary Sound pressure level (H) db() 44 48 52 52 52 52 53 Sound power level (H) db() 61 65 69 69 69 69 70 Dimensions LxWxH Packing LxWxH mm mm 760x285 x590 887x355 x645 845x320 x700 965x395 x755 900x315 x860 1.043x395 x915 938x392x1.369 1.095x495x1.505 Net/gross weight kg 35,4/37,9 46/50 59/63 100/114 102/116 102/118 107/120 Liquid inch 6,35 (1/4 ) 6,35 (1/4 ) 9,52 (3/8 ) 9,52 (3/8 ) 9,52 (3/8 ) 9,52 (3/8 ) 9,52 (3/8 ) Piping diameters Gas inch 9,52 (3/8 ) 12,7 (1/2 ) 15,9 (5/8 ) 15,9 (5/8 ) 15,9 (5/8 ) 15,9 (5/8 ) 15,9 (5/8 ) Drainage mm 25 25 32 32 32 32 32 Max. input current 9,5 10 13 25 11 13 15 Maximum lenght of the line m 20 30 50 65 65 65 65 Maximum height difference m 10 20 25 30 30 30 30 Outdoor temperature C -15... +50 cooling / heating -15... +24 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27 C DB, 19 C WB 35 C DB 5 m 0 m Heating mode 20 C DB, 19 C WB 7 C DB, 6 C WB 5 m 0 m Seasonal efficiency according to EN 14825. Seasonal efficiency and energy lebelling is not applicable to split systems with cooling capacity exceeding 12 kw. The sound pressure value may vary depending on ambient conditions.

Ceiling/Floor Inverter High efficiency Split Ceiling/Floor Inverter High efficiency Split SYSPLIT CEILING EVO HP Features SYSPLIT CEILING EVO air conditioners are perfectly combined with any interior and are stylish with modern design. dvanced DC inverter control for the compressor, outdoor fan motor and indoor fan motor. Flexible installation, the unit can be installed hanged on the wall or ceiling suspended. High efficient and washable air filter included. utomatic distribution of the treated air in the horizontal and vertical directions. Compact, easy to install and maintain, can be even installed in a corner. Low noise level thanks to the improved shape of the impeller blades. The fresh air intake can fulfill air quality requirements and enhance occupants comfort. With the uto-restart function the unit resume with the same settings before the electric power failure. Environment friendly R410 refrigerant. Infrared remote controller SYSCONTROL RM 52 included; Wired remote SYSCONTROL WC 90 available as accessory. B Dimensions Wired controller SYSCONTROL WC 90 rt. no. 314139 (optional) Infrared remote control SYSCONTROL RM 52 (standard) SYSPLIT OUTDOOR size 12 to 24 C D H H size 36 to 60 H H SYSPLIT CEILING H E B E E C C D D D 24 36 48 60 Model 1.068 1.068 1.650 1.650 1.650 18 24 36 48 60 845 900 938 938 938 B 675 675 675 675 675 B C 235 235 235 235 235 C 560 335 590 634 634 634 333 404 404 D 983 983 1.565 1.565 1.565 D 404 360 355 448 448 E 220 220 220 220 220 448 E 312 302 368 368 368 F 320 315 392 392 392 H 700 860 1.369 1.369 1.369 B B E C D 18 F Model F F C H BB BB E 24

Ceiling/Floor Inverter High efficiency Split 25 Technical features Model Indoor unit SYSPLIT CEILING 18 EVO HP Q 24 EVO HP Q 36 EVO HP Q 36 EVO HP Q 48 EVO HP Q 60 EVO HP Q Model Outdoor unit SYSPLIT OUTDOOR 18 EVO HP Q 24 EVO HP Q 36 EVO HP Q 36 EVO HP R 48 EVO HP R 60 EVO HP R rt. no. Indoor unit 314042 314043 314044 314044 314046 314048 rt. no. Outdoor unit 314057 314058 314059 314060 314062 314063 Refrigerant Power supply V/Ph/Hz 220-240/1/50 380-420/3/50 380-420/3/50 Cooling capacity kw 5,29 7,04 10,56 10,55 - - Power consumption W 1.450 2.070 3.080 2.770 4.380 5.110 Operating current 6,3 9,0 13,4 4,8 7,6 8,8 EER 3,65 3,40 3,43 3,81 3,21 3,21 SEER 6,2 6,6 6,0 6,5 - - Energy label cooling ++ ++ + ++ - - Heating capacity kw 5,85 7,60 11,71 11,72 - - Power consumption W 1.410 1.900 3.140 2.930 4.420 5.280 Operating current 6,1 8,3 13,7 5,1 7,6 9,1 COP 4,15 4,00 3,73 4,00 3,71 3,61 SCOP (verage) 3,8 3,8 3,8 3,8 - - Energy label heating - - Indoor Unit ir flow rate (H/M/L) m 3 /h 900/ 750/600 1.400/ 1.250/1.100 R410 2.200/1.850/1.500 2.300/1.900/1.700 Sound pressure level (H) db() 43 46 47 48 50 50 Sound power level (H) db() 60 63 64 65 67 67 Dimensions LxWxH mm 1.068x675x235 1.650x675x235 Packing LxWxH mm 1.145x755x313 1.725x755x313 Net/gross weight kg 25/31,5 25/30 40/46 40/46 40/46 40/46 Outdoor Unit Compressor Type Rotary Twin-rotary Twin-rotary Twin-rotary Twin-rotary Twin-rotary Sound pressure level (H) db() 48 52 52 52 52 53 Sound power level (H) db() 65 69 69 69 69 70 Dimensions LxWxH mm 845x320x700 900x315x860 938x392x1.369 Packing LxWxH mm 965x395 x755 1.043x395 x915 1.095x495x1.505 Net/gross weight kg 46/50 59/63 100/114 102/116 102/118 107/120 Liquid inch 6,35 (1/4") 9,52 (3/8") 9,52 (3/8") 9,52 (3/8") 9,52 (3/8") 9,52 (3/8") Piping diameters Gas inch 12,7 (1/2") 15,9 (5/8") 15,9 (5/8") 15,9 (5/8") 15,9 (5/8") 15,9 (5/8") Drainage mm 32 32 32 32 32 32 Max. input current 10 13 25 11 13 15 Maximum lenght of the line m 30 50 65 65 65 65 Maximum height difference m 20 25 30 30 30 30 Outdoor temperature C -15... +50 cooling / heating -15... +24 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27 C DB, 19 C WB 35 C DB 5 m 0 m Heating mode 20 C DB, 19 C WB 7 C DB, 6 C WB 5 m 0 m Seasonal efficiency according to EN 14825. Seasonal efficiency and energy lebelling is not applicable to split systems with cooling capacity exceeding 12 kw. The sound pressure value may vary depending on ambient conditions.

Duct Inverter High efficiency Split Duct Inverter High efficiency Split SYSPLIT DUCT EVO HP Features SYSPLIT DUCT EVO air conditioners are designed using the latest engineering solutions and allow their installation with a minimum ceiling height. dvanced DC inverter control for the compressor, outdoor fan motor and indoor fan motor. One indoor unit can serve several facilities through a network of ducts to the high external static pressure. ir conditioners are equipped with washable air filter. Flexible air intake from the rear (factory standard), it can be easily changed to bottom air intake using the same flange plate. The fresh air hole on the side of the unit makes easy the connection to the external air intake. Built-in drain pump can lift the condensate water up to 750 mm. With the uto-restart function the unit resumes with the same settings before the electric power failure. Environment friendly R410 refrigerant. Wired remote controller SYSCONTROL WC 90 included; Infrared remote control SYSCONTROL RM 52 rt. no. 314137 (optional) Wired controller SYSCONTROL WC 90 (standard) Infrared remote controller SYSCONTROL RM 52 available as accessory. G Dimensions H E E C C D D 12 18 24 36 48 60 760 845 900 938 938 938 530 E C D 18 24 36 48 60 Model 560 590 634 634 634 290 335 333 404 404 404 D 315 360 355 448 448 448 80 E 270 312 302 368 368 368 968 968 F 285 320 315 392 392 392 40 40 40 H 590 700 860 1.369 1.369 1.369 204 204 204 700 920 920 1.200 1.200 1.200 B 210 270 270 300 300 300 B C 635 635 635 865 865 865 C D 570 570 570 800 800 800 E 65 65 65 80 80 F 493 716 716 968 G 35 35 35 H 119 179 179 B B F D 12 C F F D C H BB BB Model H H F E size 36 to 60 B F E Outdoor unit size 12 to 24 H H G B H SYSPLIT DUCT H 26

Duct Inverter High efficiency Split 27 Technical features Model Indoor unit Model Outdoor unit SYSPLIT DUCT SYSPLIT OUTDOOR 12 EVO HP Q 12 EVO HP Q 18 EVO HP Q 18 EVO HP Q 24 EVO HP Q 24 EVO HP Q 36 EVO HP Q 36 EVO HP Q 36 EVO HP Q 36 EVO HP R 48 EVO HP Q 48 EVO HP R 60 EVO HP Q 60 EVO HP R rt. no. Indoor unit 314026 314027 314022 314023 314023 314045 314047 rt. no. Outdoor unit 314056 314057 314058 314059 314060 314062 314063 Refrigerant R410 Power supply V/Ph/Hz 220-240/1/50 380-420/3/50 380-420/3/50 Cooling capacity kw 3,51 5,27 7,02 10,56 10,56 14,06 16,69 Power consumption W 1.080 1.460 2.060 3.290 2.780 4.380 5.200 Operating current 4,7 6,3 9,0 14,3 4,8 7,6 9,0 EER 3,25 3,61 3,41 3,21 3,80 3,21 3,21 SEER 5,3 6,4 6,7 6,0 6,1 - - Energy label cooling ++ ++ + ++ - - Heating capacity kw 4,11 5,87 7,61 11,72 11,72 17,01 19,05 Power consumption W 1.080 1.450 1.950 3.160 2.790 4.560 5.220 Operating current 4,7 6,3 8,5 13,7 4,8 7,9 9,0 COP 3,81 4,05 3,90 3,71 4,20 3,73 3,65 SCOP (verage) 3,8 3,8 3,8 3,8 3,8 - - Energy label heating - - Indoor Unit ir flow rate (H/M/L) m 3 /h 800/ 610/520 1.400/ 1.100/1.000 1.700/ 1.400/1.250 2.270/1.890/1.650 3.010/2.410/1.940 External static pressure (H) Pa 40 70 70 80 80 100 100 Sound pressure level (H/M/L) db() 40 42 46 45 44 46 46 Sound power level (H) db() 57 59 63 62 61 63 63 Dimensions LxWxH mm 700x 635x210 920x635x270 1.200x865x300 Packing LxWxH mm 915x 655x290 1.135x655x350 1.385x920x373 Net/gross weight kg 18,1/22,8 28/31,5 28/31,5 44/52,5 44/52,5 44/55 45/53 Outdoor Unit Compressor Type Rotary Rotary Twin-rotary Twin-rotary Twin-rotary Twin-rotary Twin-rotary Sound pressure level (H) db() 44 48 52 52 52 52 53 Sound power level (H) db() 61 65 69 69 67 69 70 Dimensions LxWxH Packing LxWxH mm mm 760x 285x590 887x 355x645 845x 320x700 965x 395x755 900x 315x860 1.043x 395x915 938x392x1369 1.095x495x1.505 Unit weight kg 35,4/37,9 46/50 59/63 100/114 102/116 102/118 107/120 Liquid inch 6,35 (1/4 ) 6,35 (1/4 ) 9,52 (3/8 ) 9,52 (3/8 ) 9,52 (3/8 ) 9,52 (3/8 ) 9,52 (3/8 ) Piping diameters Gas inch 9,52 (3/8 ) 12,7 (1/2 ) 15,9 (5/8 ) 15,9 (5/8 ) 15,9 (5/8 ) 15,9 (5/8 ) 15,9 (5/8 ) Drainage mm 25 25 25 25 25 25 25 Max. input current 9,5 10 13 25 11 13 15 Maximum lenght of the line m 20 30 50 65 65 65 65 Maximum height difference m 10 20 25 30 30 30 30 Outdoor temperature C -15... +50 cooling / heating -15... +24 Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27 C DB, 19 C WB 35 C DB 5 m 0 m Heating mode 20 C DB, 19 C WB 7 C DB, 6 C WB 5 m 0 m Seasonal efficiency according to EN 14825. Seasonal efficiency and energy lebelling is not applicable to split systems with cooling capacity exceeding 12 kw. The sound pressure value may vary depending on ambient conditions.

28 Duct On/Off Split Duct On/Off Split SYSPLIT DUCT HT Features SYSPLIT DUCT HT air conditioners are suitable for large commercial spaces providing highest cooling/heating capacity and powerfull air flow. One indoor unit can serve several facilities through a network of ducts. High external static pressure up to 200 Pa. ir conditioners are equipped with washable air filter. Environment friendly R410 refrigerant. Cooling operation with outdoor temperature up to +52 C. With the uto-restart function the unit resumes with the same settings before the electric power failure Environment friendly R410 refrigerant. Wired remote controller SYSCONTROL WC 90 included; Infrared remote controller SYSCONTROL RM 52 available as accessory. Infrared remote control SYSCONTROL RM 52 rt. no. 314137 (optional) SYSPLIT OUTDOOR 76/96 HT R Wired controller SYSCONTROL WC 90 (standard) SYSPLIT OUTDOOR 120 HT R Dimensions SYSPLIT DUCT 76/96 HT Q SYSPLIT OUTDOOR 76/96 HT R 1350 760 656 469 45 1260 654 762 5 330 1205 330 450 5 231 132 26 507 800 840 180 908 179 700 57 676 SYSPLIT DUCT 120 HT Q SYSPLIT OUTDOOR 120 HTR 1828 858 106 120 45 1260 654 762 638 330 330 1895 330 30 24 677 750 180 15 908 519 737 700 676

Duct On/Off Split 29 Technical features Model Indoor unit SYSPLIT DUCT 76 HT Q 96 HT Q 120 HT Q Model Outdoor unit SYSPLIT OUTDOOR 76 HT R 96 HT R 120 HT R rt. no. Indoor unit 314070 314071 314072 rt. no. Outdoor unit 314179 314180 314181 Refrigerant R410 Power supply V/Ph/Hz 380-415/3/50 Cooling capacity kw 22,0 28,0 35,0 Power consumption W 7.500 9.600 12.000 Rated current 19,3 23,7 28,6 EER 2,93 2,92 2,92 Heating capacity kw 25,0 31,0 38,0 Power consumption W 8.300 10.300 12.600 Rated current 21,3 26,5 31,5 COP 3,01 3,01 3,02 Indoor Unit Power supply V/Ph/Hz 220-240/1/50 ir flow rate (H/M/L) m 3 /h 4.250/3.760/3.220 5.100/4.410/3.760 6.375/5.920/5.430 External static pressure (Hi) Pa 200 150 Sound pressure level (H) db() 53 54 56 Dimensions (LxWxH) mm 1.350x760x450 1.828x858x638 Packing LxWxH mm 1.549x917x476 2.095x929x689 Net/gross weight kg 105/120 188/220 Outdoor Unit Power supply V/Ph/Hz 380-415/3/50 Compressor Type Scroll Scroll Scroll ir flow rate m 3 /h 7.200 10.400 12.000 Sound pressure level (Hi) db() 65 67 69 Dimensions (LxWxH) mm 1.260x908x700 Packing LxWxH mm 1.320x1.060x730 Net/gross weight kg 174/193 187/204 201/217 Liquid inch 9,52 (3/8 ) 12,7 (1/2 ) Piping diameters Gas inch 22,2 (7/8 ) 25,4 (1 ) 28,6 (1 1/8 ) Drainage mm 41 Locked rotor amp 110 110 147 Maximum lenght of the line m 50 Maximum height difference m 30 Outdoor temperature C +21... +52 cooling / heating -10... +24 Fan performance SYSPLIT DUCT 76 HT Q SYSPLIT DUCT 96 HT Q SYSPLIT DUCT 120 HT Q Static Pressure(Pa) 260 240 220 Lo Med Hi 200 180 160 140 120 100 80 60 40 20 0 2750 3000 3250 3500 3750 4000 4250 4500 4750 5000 5250 ir Flow(m 3 /h) Static Pressure (Pa) 260 240 220 Lo Med Hi 200 180 160 140 120 100 80 60 40 20 0 3500 3750 4000 4250 4500 4750 5000 5250 5500 5750 6000 ir Flow (m 3 /h) Static Pressure (Pa) 200 180 Lo Med Hi 160 140 120 100 80 60 40 20 0 4250 4750 5250 5750 6250 6750 7250 7750 ir Flow (m 3 /h) Nominal conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27 C DB, 19 C WB 35 C DB 5 m 0 m Heating mode 20 C DB, 19 C WB 7 C DB, 6 C WB 5 m 0 m The sound pressure value may vary depending on ambient conditions.

30 VRF systems SYSVRF

VRF systems 31 SYSVRF multi-zone solutions: light commercial and commercial VRF systems The SYSVRF modular systems are most valuable for room space from 100 to 1000 sq.m. with large independence of climatic zones - hotels, restaurants, retail, office buildings, etc. Up to 4 modular outdoor units can be combined in one single refrigerant system thus reaching up to 200kW of cooling capacity and connecting up to 64 indoor units. In the same system they are able to fulfill the increasing demands of air comfort still having low operating costs. ll SYSVRF systems are equipped with DC Inverter compressors and DC Inverter fans which gives enhanced system performance and very low operating noise. The new generation of 3-pipe systems are equipped with all DC Inverter compressor which delivers outstanding comfort pleasure and reduces tremendously the electricity consumption. SYSVRF of Systemair are available with different configurations: the typical heat pump Mini and Modular 2-pipe outdoor units or the superior Modular heat recovery 3-pipe units. SYSVRF Mini and SYSVRF Modular systems SYSVRF IR EVO HP Mini 34 SYSVRF DUCT 54 SYSVRF IR EVO HP 36 SYSVRF DUCT HP 56 SYSVRF IR EVO HR 40 SYSVRF HRV 58 SYSVRF WLL 46 SYSCONTROL HU 60 SYSVRF CSSETTE MINI 48 SYSVRF selection software 61 SYSVRF CSSETTE 50 SYSCONTROL systems 62 SYSVRF CEILING 52 accessories 64

32 VRF systems VRF Systemair- SYSVRF Multi-zone air conditioning system VRF systems are most beneficial for space up to 1500-2000 sq.m. with large independence of climatic zones hotels, restaurants, retail space, office buildings, etc. In the same system they are able to fulfill the increasing demands of the parameters of air in each room and still have low operating costs. balanced lineup The lineup of multizone VRF series are continuously optimized. In response to market demands Systemair offers several types and sizes of indoor units: wallmounted, cassette, floor-ceiling and duct. Outdoor units Mini, despite the compact dimensions, solve different tasks of air conditioning on small objects. Six modular outdoor units can be combined in one refrigerant system thus reaching a total cooling capacity of up to 200 kw. Separately, to highlight the 3 Pipe heat recovery system for indipendent and simultaneous cooling and heating operation. The most comfortable temperature n important advantage of the multi-zone air-conditioning is a smooth and rapid achievement of a comfortable temperature, as well as maintaining the specified parameters accurate to ± 0,5 C. Such high performance was achieved thanks to an accurate control of the refrigerant flow and the mechanism of redistribution of refrigerant between the several units, implemented with the help of electronic expansion valves. High energy efficiency The efficiency of multi-zone systems is very high, because each time the electric power is consumed as much as necessary to carry out user requirements. If the indoor units work only in a few areas of the building, then the power consumption is reduced proportionally by changing the refrigerant flow. Continuous development in the field of management In modern air-conditioning systems the demand for automation and control systems integrated with other infrastructure building systems is continuously increasing. These are exactly the principles on the basic of the development of the control systems of Systemair. In addition to the traditional control systems of air conditioning, the user deals with different possibilities of control that can solve the various needs of the building management such as the possibility of control via personal computer and Internet network connection. Simplicity of design Systemair provides full integration and coordination of all elements of a multizone system, greatly simplifies the task of the designer. The selection process can be performed in maximum short period of time by using a simple and complete selection and designing software. Low noise Low noise of both outdoor and indoor units makes the job a multizone system virtually inconspicuous.