DISTRIBUTION SWITCHBOARDS

Similar documents
Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Secondary Unit Substations

How To Test A Power Switch On A Power Supply

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

Engineers Edge, LLC PDH & Professional Training

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Applications. Remote Display Mounting Kits

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Introduction. Upon completion of Basics of Switchboards you should be able to: Explain the role of switchboards in a distribution system

Mini Power-Zone Unit Substation

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Unit substation solutions with type SIMOSEC primary switches quick reference guide E50001-F710-A389-X-4A00. Answers for energy.

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

MCC Ratings. Voltage Rating

Medium Voltage Motor Control Assemblies

Sample - No Commercial Use

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B

CPS Y S K CPS Y S C

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

Section 10 Electric Switchboards: 0 Through 600 Volts

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

LVA Take Offs in Bid Manager

Switchgear Capabilities. NexGear is a Division of PowerSecure NASDAQ: POWR

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

8146/5 Series Breaker Panelboards

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

IRRIGATION PUMPING Table of Contents - Section 900

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Distribution Dry Type Transformers

GE Power Controls. MiniFORM Switchboards

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Bolted contact switches. Pringle switches

Cable/Conduit Conversion

SECTION 16426C ARC RESISTANT DRAWOUT SWITCHGEAR (MAGNUM DS) LOW VOLTAGE

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

ASCO SERIES 185 Power Transfer Switches

SECTION 16346A METAL-CLAD MEDIUM VOLTAGE ARC RESISTANT SWITCHGEAR

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600

Modan 3000 ADVANCED TECHNOLOGY, INDUSTRIAL GRADE MOTOR CONTROL CENTER. Systems Products and Services. Motor Control Centers Modan 3000

Primary and Secondary Electrical Distribution Systems

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

101 BASICS SERIES LEARNING MODULE 3: FUNDAMENTALS OF ELECTRICAL DISTRIBUTION. Cutler-Hammer

SWITCHGEAR. EGP Switchgear

Mission Critical Data Center Systems

Power Management Module 2. Installation

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

DATA CENTER UNIQUE CHARACTERISTICS AND THE ROLE OF MEDIUM VOLTAGE VACUUM CIRCUIT BREAKERS

Top Commercial / Residential Electrical Requirements *

Decision-Maker Paralleling System. Power Distribution Switchboards and Circuit Breakers. Standard Features

MidNite Solar E-Panels Explained

MOBILE HOME SERVICE REQUIREMENTS GAS

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services

SURGELOGIC TVSS Surge Protective Devices Enhance System Protection and Reduce Equipment Damage

Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

A Comparison of Contemporary Electrical Distribution Equipment Standards. San Francisco IEEE Industry Applications Society May 26, 2009

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

Contents. Clean Control Center Harmonic Correction Unit. Selection Dimensions Specifications. Description

Siemens STEP 2000 Course Basics of Electrical Products

SECTION VARIABLE FREQUENCY DRIVES

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Eaton Automatic Transfer Switches

The following components are common to most cubicles; this example is an ABB HK cubicle.

UL 508A Industrial Control Panels Power Distribution and Control. Lunch & Learn Training Eaton Corporation. All rights reserved.

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Fusible Disconnect Switch

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

Short Circuit Current Calculations

Mains. Assembly SCCRs. Voltage ratings. Bus amperages. Branch circuits. Panels. Through-lugs & loadside disconnect. Neutrals. Grounds.

PowerChain Management solutions. PowerChain Management Solutions for Data Centers

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

SECTION SWITCHBOARDS

Continuous Power... Continuous Protection

Instructions for Magnum DS T

APC 3Phase Power Distribution

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

Transcription:

DISTRIBUTION SWITCHBOARDS

CUTLER-HAMMER DISTRIBUTION SWITCHBOARDS Group Mounted Distribution Switchboards Pow-R-Line C Pow-R-Line C Switchboards Cutler-Hammer Distribution Switchboards combine a space-saving design with modular construction and increased systems ratings to provide economical and dependable electrical system distribution and protection. Features 6000A maximum main bus rating. 600V AC and below. Front or rear accessible. Type 1 or Type 3R enclosures. ANSI-61 gray powder coat paint finish. The IQ family of microprocessor-based metering and monitoring devices. Utility metering provisions. Transient Voltage Surge Suppression (TVSS). Ground fault protection on mains and distribution devices. Busway and transformer connections. Complete protective device accessory capability. 65 kaic standard bus bracing. Optional 100 or 200 kaic. Standard tin-plated aluminum bus. Optional copper or silver-plated copper bus. Meet NEMA Standard PB-2 and UL 891. Seismically qualified. Main Devices DS/DSL Power Circuit Breakers, 800-4000A, fixed or drawout. SPB Insulated Case Circuit Breakers, 800-5000A fixed, 800-4000A drawout. Magnum DS Power Circuit Breakers, 800-5000A, fixed or drawout. Molded case circuit breakers, 400-2500A, fixed mounted. Bolted pressure switches, 800-5000A. FDPW Fusible Switches, 400-1200A. Series C Molded Case Circuit Breakers Utility metering compartments are available to meet standard or specific requirements. Units can be arranged for hot or cold sequence. Group Mounted Distribution Devices Molded case circuit breakers, 15-1200A. FDPW Fusible Switches, 30-1200A. Magnum DS Power Circuit Breakers IQ Metering and Monitoring Devices These microprocessor-based devices provide more usable information with greater accuracy than is usually obtainable with conventional meters and switches. IQ devices monitor and display electrical data from basic amperes and volts to complete system parameters including detailed power quality information. The single chassis design provides device flexibility, accommodating both circuit breaker and fusible switches. IQ Analyzer IQ Data IQ 200 2 Distribution Switchboards

Advanced Technology Options Offer Superior Protection, Energy Management and Communications Digitrip OPTIM Trip Unit System Programmable Trip Unit System Provides enhanced accuracy and reliability for protection, and optimum system coordination. Digitrip OPTIM has advanced system early warning features, as well as system diagnostics, load, power and energy, power monitoring capability, and communications. It will help reduce system downtime which will add to increased productivity. Programming and trip unit monitoring can be completed at the trip unit with the hand-held OPTIMizer while the Breaker Interface Module provides programming and monitoring at the assembly. With a Cutler-Hammer communications system, programming and monitoring can be accomplished remotely from a personal computer. Clipper Power System Transient Voltage Surge Suppression The Clipper Power System (CPS) consists of Transient Voltage Surge Suppression (TVSS) and active hybrid filtering. The CPS protects sensitive electronic equipment from the damaging effects of high and low energy transients, as well as high frequency noise. The CPS, combined with our innovative direct bus bar connection, yields the industry s lowest let-through voltage. Wide Range of Surge Ratings Surge current ratings from 100 to 400 ka per phase provide a range of cost-effective facility-wide protection solutions. Products are third party tested to verify published surge current ratings. TVSS mounted within the enclosure, eliminating extra wiring and outboard wall space: UL 1449 and UL 1283 listed high performance suppression system and parallel hybrid filter technology. Integral 200 kaic fusing system. TRI-Monitor diagnostic system. Integral circuit breaker disconnect. Direct bus bar connection. IQ Analyzer The Premier Electronic Meter A powerful analyzer and accurate meter that provides extensive system information on an easy-to-read display. It measures an extensive list of electrical parameters including power and energy. With its ANSI C12.16 Class 10 accuracy specification for revenue meters, the IQ Analyzer is the ideal meter for utility bill verification at the utility point of coupling. It also provides detailed power quality information. IQ Energy Sentinels Cost-Effective Submetering Throughout the Electrical System These devices monitor power and energy readings down to the smaller loads. They measure watts, peak demand, and watthours within a one-percent accuracy level. The device mounts directly on F-, J- or K-Frame feeder breakers without requiring additional panel height. A Universal Sentinel is available where breaker mounting is not feasible and for the larger frame breakers. Monitoring and diagnostics for all internal components are provided by our patented TRI-Monitor system. Power and energy information from IQ Sentinels can be communicated to a PC, a panel mounted Central Energy Display (CED), or even existing building management or distribution control systems. Distribution Switchboards 3

CUTLER-HAMMER DISTRIBUTION SWITCHBOARDS Compartmentalized Design for Increased Device Isolation Pow-R-Line Switchboards Pow-R-Line Pow-R-Line Distribution Switchboards are engineered in a compartmentalized design for applications where a greater degree of component isolation is required. A wide variety of configurations is possible including utility metering, customer metering, main devices, branch devices, accessories, and enclosures. Significant Safety Features Individual compartments for branch devices glass polyester for breakers and steel for fusible switches. Compartments help eliminate possible contact with the main bus and reduce fault propagation. Three-section construction with each barriered from the other: Device section. Each device is mounted in its own compartment. Bus bar section. Contains both horizontal and vertical busses. Rear cable compartment. Completely isolated from the bus bars. Insulated copper runbacks. Power is taken from the protective device by the runback through a standard full height glass-polyester barrier to the rear cable compartment, virtually eliminating the possibility of accidental contact with the main busses during installation or maintenance. A Wide Selection of Branch Devices Circuit Breakers Branch circuit breakers range from 150 to 1200 ampere frames. They are available in standard and high interrupting ratings for increased performance. Devices are tandem mounted through 400 amperes and single mounted for ratings above 400 amperes. Fusible Switches Branch fusible switches are available from 100 to 1200 ampere frames. The units are horizontally mounted in single unit steel enclosure construction. Branch fusible switches in single unit construction. Utility metering compartments are available to meet standard or specific requirements. Units can be arranged for hot or cold sequence. Branch circuit breakers in single and tandem mounted construction. Branch circuit breaker ground fault protection can be provided integral to the device or with separate relay and test panel mounted in compartments similar to the circuit breakers for convenience and space savings. Digitrip OPTIM Trip Units are wired at the factory to customer specifications and are shipped ready for customer programming. Provisions for future include line side connectors, load side runbacks, terminals, and glass-polyester compartments and covers for circuit breakers. Space only for both circuit breakers and fusible switches is also available. 4 Distribution Switchboards

Barriered Construction for Rear Connection Distribution Section 1 Available zero sequence ground fault. 7 Angled neutral connections. 2 3 4 5 6 Tandem mounted circuit breakers through 400 amperes. Glass-polyester circuit breaker compartment. Insulated copper load side runbacks. Isolated bus compartment. Horizontal cross bus. 8 9 10 11 Anti-turn lugs. A-, B-, and C-phase labeling. Full length barrier isolating the cable compartment. Movable cable brace. 12 Generous conduit space. Load side runbacks in the barriered rear cable compartment provide for easy termination plus ample room for cable bending. 4 7 9 8 1 5 2 6 6 10 3 11 12 Front View Rear View Construction Features Full family of IQ metering and protective devices available. Utility metering compartments built to specific utility requirements. Individually mounted main devices. Compartmentalized feeder devices. Meets NEMA Standard PB-2 and UL 891. Rear accessible. 6000 ampere main bus. 65 kaic standard bus bracing. Optional 100 and 200 kaic. Standard aluminum bus. Optional copper- or silver-plated bus bar. A full range of device modifications. ANSI-61 gray powder coat paint finish. Type 1 or Type 3R enclosures. Seismically qualified. Distribution Switchboards 5

CUTLER-HAMMER DISTRIBUTION SWITCHBOARDS Reliable Multiple Circuit Distribution and Metering for Commercial Applications COMMERCIAL METERING Pow-R-Line C Commercial Metering Switchboards Cutler-Hammer commercial metering switchboards provide electrical system distribution and metering for shopping centers, office buildings, and other commercial multimetering applications. Features Freestanding rugged Pow-R-Line C Switchboard construction. Factory-assembled sections come ready for connection of tenant cables and installation of utility-provided watthour meters. Reduced field wiring and installation costs. Front-accessible design provides for mounting against a wall. Tamper-proof enclosed assembly provides safety and convenience. Utility-approved incoming service terminations and sealable covers over unmetered sections. Meet NEMA Standard PB-2 and UL 891. Seismically qualified. 120/240V, single-phase, three-wire. 240/120, 208Y/120 or 480Y/277V, three-phase, four-wire. Type 1 or Type 3R enclosures. Tenant Metering Sections Tenant metering sections provide arrangements for grouping individual tenant feeder circuits rated 200 amperes or less. Each circuit consists of a utility-approved meter socket and an appropriate disconnect device. Requirements for tenant-metered circuits over 200 amperes can be met using separate sections with appropriate disconnect devices installed in combination with a current transformer/metering compartment. Type WWCMS for EUSERC Service Areas Tenant Metering Section Type WCMS Tenant Metering Section Type WCMS WWCMS Construction Assembly includes meter socket and test block per EUSERC requirements, prewired to tenant disconnect. Type WWCMS The meter socket is a ring-type device rated 200 amperes continuous for self-contained metering applications. The assembly includes a bypass test block in a fully bussed combination to meet EUSERC standard requirements. Sealable covers are provided to comply with utility standard requirements. The meter socket is a ringless-type device rated 200 amperes continuous for self-contained metering applications. All sockets include a manual lever bypass device. Each meter socket is provided with an individual screwless cover that includes a sealing bracket with provisions for barrel locks, sealing wire, or sealing bands. Individual internal barriers are provided around each socket. WCMS Construction Typical 200 ampere sevenjaw sockets with manual lever bypass connected to circuit breaker disconnects in hot sequence arrangement. 6 Distribution Switchboards

Preassembled and Available from Stock Pow-R-Line C Instant Switchboards Instant Switchboards are suitable for use as service entrance equipment. They include EUSERC utility metering provisions and a fused main switch with optional distribution panelboard in a single compact section for easy installation with or without underground pull sections. Construction Features Completely enclosed with front, rear, and side covers. Manufactured of code-gauge steel with ANSI-61 gray powder coat paint finish. Available in Type 1 and Type 3R enclosures. Outdoor units include front hinged padlockable door. UL listed and meets EUSERC, NEC, and NEMA standards. Seismically qualified. Service Ratings 120/240V AC (Singe-phase, three-wire). 208Y/120 or 240/120V AC (Three-phase, four-wire). 480Y/277V AC (Three-phase, four-wire). Metering Compartment Meets EUSERC standards. Barriered hot sequence CT provisions. Provisions for meter socket with test block provision. Hinged sealable compartment doors. Standard section includes two 15-inch high doors (one for socket, one blank). Main Switch 400 or 600 ampere ratings. Factory installed Class T Fuses. Load lugs or connection to panelboard. Padlocking provisions for switch. Hinged cover with interlock. Distribution Panelboard Factory installed. Provisions for bolt-on circuit breakers. INSTANT Cutler-Hammer Switchboards Best Service in the Industry Quality Construction All Cutler-Hammer Switchboards are assembled using superior components. Parts are manufactured by robotic equipment to exacting specifications to assure precision construction of stable, rigid structures. Seismic Qualification SEISMIC QUALIFIED U.B.C. and C.B.C. Pow-R-Line C Switchboards are seismically Cutler-Hammer tested and qualified to Must Be Installed Per Applicable Code and Maintenance Recommendations exceed requirements of both the Uniform Building Code (UBC) and California Building Code (CBC). Contact Cutler-Hammer for details. Quality Assurance Final testing helps assure that each switchboard performs in accordance with UL standards and customer specifications. Each assembly is shipped with a Switchboard Verification Report that documents completion of every inspection and test. All switchboards are backed by the Cutler-Hammer commitment to quality, safety, and reliability. Cutler-Hammer Switchboards are custombuilt to your requirements utilizing worldclass manufacturing techniques at our plants in Sumter, SC and Grand Prairie, TX. In addition, Cutler-Hammer has an extensive network of regional Satellite Plants located across the country that are specifically oriented to providing Pow-R-Line C Panelboards and Switchboards to meet your fast service needs. Highly trained and experienced personnel will manage your order and assure that you receive on-time delivery of high quality equipment that meets your specifications. SEATTLE SAN FRANCISCO LOS ANGELES PHOENIX DENVER DALLAS HOUSTON CHICAGO ST. LOUIS GRAND PRAIRIE CLEVELAND BALTIMORE ATLANTA ORLANDO RALEIGH SUMTER WINDSOR For More Information For more information, contact your Cutler- Hammer representative or authorized distributor. Copyright Cutler-Hammer Inc., 1999. All Rights Reserved Distribution Switchboards 7

Cutler-Hammer, a part of Eaton Corporation, is a worldwide leader providing customer-driven solutions. From power distribution and electrical control products to industrial automation, Cutler-Hammer utilizes advanced product development, world-class manufacturing, and offers global engineering services and support. For more information on Cutler-Hammer products, call 1-800-525-2000 or 1-616-982-1059, for engineering services call 1-800-498-2678 or visit our website at www.cutlerhammer.eaton.com B3901SE Pittsburgh, Pennsylvania U.S.A. Publication No. B.39.01.S.E February 1999 Printed in U.S.A. / CMS 3036