DP Series. Differential Pressure Sensor. Installation and Operating Manual

Similar documents
BLUE RIBBON CORP. BC001 Birdcage Installation Manual

Models SFP33 & SFP32 Pressure Transmitters

SEMICONDUCTOR TECHNICAL DATA

Subminiature Load Cell Model 8417

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

Model SRMD Setra Remote Monitoring Display

Part I - Installation

Series 510 Submersible Level Transmitters

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

ENCODER TEST MODULE APPLICATION GUIDE

SDX Submersible Depth Transmitter User Manual

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Talon and Talon SR User Manual

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Digital inductive conductivity transmitter

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

O C M III. Open Channel Flow Monitor

Reaction Torque Sensor

Typical Aluminum GFM Mass Flow Meter

TYPE 65UV CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

NEXUS FX04 and FX04-1 Servo Motor Installation. Fireye DESCRIPTION SAFETY INFORMATION. FX04-1 Shown

Submersion/Insertion Toroidal Sensor

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Combustible Gas Transmitter RK-05

2 & 5-Wire Overfill Sensors

ViZion Installation Guide

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

K-Type Thermocouple Sensor User s Guide

Freescale Semiconductor. Integrated Silicon Pressure Sensor. On-Chip Signal Conditioned, Temperature Compensated and Calibrated MPX4080D.

Universal Vehicle Power Supply 9007AX01. Installation Instructions

Y7230A CO 2 Alarm System

The Unique Accelabar Flow Meter

Sanitary Type Electronic Flow Switches

Freescale Semiconductor. Integrated Silicon Pressure Sensor. On-Chip Signal Conditioned, Temperature Compensated and Calibrated MPX5500.

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

PTU Series Ultrahigh-Purity Pressure Transducers

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

Combustion Dynamics Instrumentation

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

QR12 (1.22 ) Diameter Optical Encoder

In-Line Electronic Flow Switches

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

289 SERIES FLOW METER TRANSMITTERS

OEM-EP Pressure Controllers

APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer

Electronic Flow Switches

Contents. Document information

The Do s and Don ts of Pressure Transducers

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

FAQ s on Siemens Magmeters

Adjustment functions for both span and shift have been incorporated

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

DIESEL FUEL CONDITIONING

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Instruction Manual Differential Pressure Transmitter

STX2100. Differential Pressure (Flow) Transmitter. GE Measurement & Control. Models FKC...5. Features

PRODUCT PROFILE FEATURES

Submersion/Insertion Toroidal Sensor

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

OPERATING INSTRUCTIONS

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Electronic Pressure Switch EDS 3000

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Integrated Silicon Pressure Sensor On-Chip Signal Conditioned, Temperature Compensated and Calibrated

PROXIMITY CARD READERS C-10, C-20, C60, C70

SELECTION, APPLICATION AND MAINTENANCE

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

PART 1 - INTRODUCTION...

Mono-Block II Installation & Operation Manual

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Inductive sensor NI10-M18-Y1X-H1141

RADIANT PLASMA 4700 Plasma Spark Generator

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

Vehicle Power Install Kit

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

PTU Series Transducer Digital Display Indicator User s Manual

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

How To Use A Flowmeter

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

ATL Fuel Level Sender Probes

Trace Dissolved Oxygen Sensor

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

DeltaSpan Submersible Pressure Level Transmitter Manual LD31 Series 22 AUG 08 Rev A

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Plastic tube flowmeters Series PT/PS

Dynamax Inc Copyright

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Transcription:

DP Series Differential Pressure Sensor Installation and Operating Manual For assistance with the operation of this product, contact Dylix Phone: 716-773-2985 Fax: 716-773-2786 E-mail: sales@dylixcorp.com Web:

Installation and Operating Manual: DP Series 1.0 Introduction Dylix DP Series Differential Pressure Sensors are designed for general pressure applications within the range and environmental conditions as specified within the Model DP Series data sheet. This information is provided as a general guide for the installation and use of this series. For non standard options or features the factory may be contacted directly. 2.0 Description This series is manufactured with 316 SS and its use is suitable for medias compatible with that material. The sensor element is designed around a central diaphragm with a silicon oil fill transferring pressure from the passive high (H) and low (L) side diaphragms. Standard pressure port connections are ¼ NPT (F). The electronic are contained within the housing section located under the electrical termination. The sensor is self contained and not designed for field repair or service. Dylix

Installation and Operating Manual: DP Series 3.0 Installation 3.1 Mechanical For best performance locate the sensor so that the lengths of tubing to both sides high (H) and low (L) are equal and on the same level. If there is a potential of condensate collecting against the diaphragm it is suggested to mount the sensor above the pressure source so that the condensate drains back to the source. The sensor can be supported by connection to a rigid metal tubing. Thread ¼ (M) threaded connection into both ports taking care to wrench on the Male connection while holding the sensor in place. Do not over torque so as to avoid damage Dylix

to the threads. Do not introduce foreign objects into the ports as this may cause damage. Install high (H) side to upstream or high line pressure and low (L) side to downstream or low line pressure. 3.2 Electrical Units must see the proper excitation to perform within specifications, insufficient power may prevent the unit from providing the full rated output at the full rated pressure. Standard excitation for the DP Series is as follows: DP1-2 to 15 Vdc (regulated), DP2 & DP3 8 to 38 Vdc (unregulated). Electrical connections as per below: Model DP1 DP2 DP3 Output mv/vdc 4 wire 0-5(10)Vdc 3 wire 4-20 madc 2 wire + Power/excit Red, Pin1, Pin A Red, Pin1, Pin A Red, Pin1, Pin A - Power/excit Black, Pin2, Pin B Black, Pin2, Pin B + Signal Green, Pin3 PinC Green, Pin3 PinC Black, Pin2, Pin B - Signal White, Pin4 Pin D Common w/black (- Power) Note that electronics can be damaged by electric surges. Surge arresters are suggested for applications where surges are possible. Unit may also need to be mechanically isolated. Electronics should not be exposed to temperatures above 250 deg F. Electrical terminations should be made in a NEMA 4 (or better) enclosure. Care must be taken to prevent migration of fluid into the cable jacket. Dylix

Installation and Operating Manual: DP Series 4.0 Operation After proper electrical and mechanical connections have been made check for proper output prior to applying pressure. When output is verified apply pressure to both sides slowly to avoid pressure spikes or exceeding the 3x FSO pressure rating of the unit. Output will increase with increase in differential pressure from high (H) side to low (L) side with the output proportional to that differential. Refer to calibration sheet provided with the unit for specific values. For units with Zero and Span adjustments field adjustments can be made. Remove zero and span cover screws, adjust zero as needed, against a known pressure source adjust span as needed, verify zero and span re-adjusting as needed, replace cover screws. 5.0 Calibration To verify performance sensor should be periodically calibrated against a known source. Pressure can be applied either via a pressure regulated supply or a dead weight tester. Calibration cycles are left to the users quality system requirements. Annual calibration cycles are common but may need to be adjusted depending on servility of application frequency of use or non standard occurrences such as being exposed to out of range conditions (ex over pressure, temperature or mechanical impact). 6.0 Maintenance All Dylix pressure sensors are engineered to be maintenance free. To ensure performance contact the factory for any non-conforming condition. Do not attempt to open the unit in the field. Dylix

7.0 Return Contact the factory for a Return Authorization Number prior to sending the units in for calibration or repair. Dylix