HAST (Highly Accelerated Stress Test)

Similar documents
How do I measure the amount of water vapor in the air?

Humidity, Condensation, Clouds, and Fog. Water in the Atmosphere

Temperature and Humidity

CONDENSATION. Section Break (Next Page)

THE HUMIDITY/MOISTURE HANDBOOK

Super Heated Steam Drying of Wood on Industrial Scale

Soil Suction. Total Suction

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

JEDEC SOLID STATE TECHNOLOGY ASSOCIATION

Psychrometrics - The Study Of Air-Water Vapor Mixtures

Principles of Rice Drying How does rice dry?

We will study the temperature-pressure diagram of nitrogen, in particular the triple point.

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

HAY MOISTURE & WEATHER:

Humid Air. Water vapor in air. Trace Glasses 1% Argon (A) Water vapor (H 2

Research on the Air Conditioning Water Heater System

Understanding Insulation Resistance Testing

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

THE PSYCHROMETRIC CHART AND ITS USE

FXA Candidates should be able to : Define and apply the concept of specific heat capacity. Select and apply the equation : E = mcδθ

Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal

Name Date Class STATES OF MATTER. SECTION 13.1 THE NATURE OF GASES (pages )

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

JEDEC SOLID STATE TECHNOLOGY ASSOCIATION

Influence of Belt Furnace on Glass-to-Metal Seal Process

Fog and Cloud Development. Bows and Flows of Angel Hair

Humidity the story for teachers

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

Advice to consumer Reference 50.1 May Condensation. Some causes, some advice.

THE PSYCHROMETRIC CHART: Theory and Application. Perry Peralta NC State University

Kiln Drying Basics for the Small Producer

The following document contains information on Cypress products.

Chapter 12 - Liquids and Solids

Materials 10-mL graduated cylinder l or 2-L beaker, preferably tall-form Thermometer

Failure code manual. content

Greenhouse Glazing Effects on Heat Transfer for Winter Heating and Summer Cooling

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

SFxxx-S PID Test Report (Potential Induced Degradation) TUV Rheinland Japan. ARC Product Management Ver. 1

Molar Mass of Butane

Phys222 W11 Quiz 1: Chapters Keys. Name:

Because here you can see a simple an elementary direct evaporative cooling system this is called as a single stage system you can see from the

ENERGY CARRIERS AND CONVERSION SYSTEMS Vol. II - Transportation of Hydrogen by Pipeline - Kunihiro Takahashi TRANSPORTATION OF HYDROGEN BY PIPELINE

3mm Photodiode,T-1 PD204-6C/L3

E. INTERNAL PACKAGING

Housing Fact Sheets. Moisture Condensation at the Windows

Distillation vaporization sublimation. vapor pressure normal boiling point.

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

ES 106 Laboratory # 6 MOISTURE IN THE ATMOSPHERE

Axial and Radial Leaded Multilayer Ceramic Capacitors for Automotive Applications Class 1 and Class 2, 50 V DC, 100 V DC and 200 V DC

InvestSmart Business Energy Upgrades Refrigeration Solutions Equipment Catalog 01/01/2015

Chapter 17: Change of Phase

Vapor Chambers. Figure 1: Example of vapor chamber. Benefits of Using Vapor Chambers

62 Max/62 Max + Infrared Thermometer

Experiment 12E LIQUID-VAPOR EQUILIBRIUM OF WATER 1

Moisture Control. It s The Dew Point. Stupid! Its not the humidity.

COURSE TITLE : REFRIGERATION AND AIR CONDITIONING COURSE CODE : 4029 COURSECATEGORY : A PERIODS/WEEK : 5 PERIODS/SEMESTER : 90 CREDITS : 4 OBJECTIVES

MP-4000 Alarm List (Software version or later)

Vapor Pressure Curves

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Troubleshooting an Air Conditioning system. R D Holder Eng. Roger D Holder MSME

Humidification Strategies for Data Centers and Network Rooms

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Chemistry 13: States of Matter

SunGuard IS 20 Technical Information

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

VTS³ and VCS³ Stress Screening Systems. More Power for Maximum Quality Assurance

VI Chip Environmental Qualification Testing Standards

Air Water Vapor Mixtures: Psychrometrics. Leon R. Glicksman c 1996, 2010

2A.1 Features of Chiller Control Components A.3 Chilled-Water Supply Temperature Control A.4 Cooling-Water Supply Control...

Purpose: To determine the dew and point and relative humidity in the classroom, and find the current relative humidity outside.

Frost Damage of Roof Tiles in Relatively Warm Areas in Japan

Online Infrared Flue Gas Analyzer Gasboard 3000

Thermal environments. Tel

Chapter 14. At temperatures below the critical temperature, the gas GAS VAPOR MIXTURES AND AIR-CONDITIONING. Objectives

Lecture 35: Atmosphere in Furnaces

Surface Tension. the surface tension of a liquid is the energy required to increase the surface area a given amount

Characteristics of Evaporators

Chapter 18 Temperature, Heat, and the First Law of Thermodynamics. Problems: 8, 11, 13, 17, 21, 27, 29, 37, 39, 41, 47, 51, 57

Partnerships Implementing Engineering Education Worcester Polytechnic Institute Worcester Public Schools

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

How To Clean Water From An Ammonia Refrigeration System

Generation of Vapor-Phase Hydrogen Peroxide Test Atmospheres for the Evaluation of Respirator Cartridges and Air Samplers

Absolute and Relative Gas Concentration: Understanding Oxygen in Air

MOLECULAR WEIGHT BY BOILING POINT ELEVATION

Environment-Laboratory Ambient Conditions

Fully Automated Distillation of Petroleum Products including Biofuels OptiDist - the Optimal Solution

13.1 The Nature of Gases. What is Kinetic Theory? Kinetic Theory and a Model for Gases. Chapter 13: States of Matter. Principles of Kinetic Theory

Calculating Creepage and Clearance Early Avoids Design Problems Later Homi Ahmadi

CONDENSATION IN REFRIDGERATED BUILDINGS

Glossary of Heating, Ventilation and Air Conditioning Terms

The Rotronic Humidity Handbook

KINETIC MOLECULAR THEORY OF MATTER

5 Answers and Solutions to Text Problems

Wet Dry Ice Lab Phase Changes and Phase Diagrams

The Second Law of Thermodynamics

2.1 The performance of bus air conditioning system is evaluated in the following operating conditions

MECHANICAL LOSS REDUCTION OF A 100 W CLASS STIRLING ENGINE. Koichi HIRATA National Maritime Research Institute, Japan

ELECTRIC HEATER COMPANY Operating and Maintenance Manual For Immersion Heating Elements

Peasouper Operator s Manual

Transcription:

HAST (Highly Accelerated Stress Test) Definition and Test Standards HAST The highly accelerated temperature and humidity stress test (HAST) is a highly accelerated method of electronic component reliability testing using temperature and humidity as the environmental parameters. HAST is also known as the pressure cooker test (PCT) or unsaturated pressure cooker test (SPCT). Its purpose is to evaluate a test sample s humidity resistance by increasing the water vapor pressure in a test chamber to an extremely high level above the partial water vapor pressure inside the test sample. This process temporally accelerates the infiltration of moisture into the sample. HAST test standards HAST is a more accelerated version of accelerated humidity-resistance testing. Compared to high-temperature/high-humidity testing (at 85 C/85% RH), HAST causes more component contact due to moisture-driven corrosion and more insulation deterioration. HAST is done mainly on plastic sealed components. The table that follows shows the most common HAST-related test standards. The test is performed at a specified temperature and relative humidity, or pressure. The atmosphere normally has a temperature of at least 100 C, in a state of water vapor pressurization. HAST is sometimes classified as a combined test when pressure is also considered as an environmental parameter. There are saturated and unsaturated varieties of HAST. The former is typically done at conditions of 121 C and 100% RH, and the latter at conditions of 110, 120 or 130 C and 85% RH. Tests done with the electronic component s power on are usually the unsaturated type. HAST is a fairly extreme test, with an acceleration factor of anywhere from tens to hundreds of times under conditions of 85 C and 85% RH. This extreme acceleration makes it important to check failure modes. 1

Table 1 Common HAST-related standards (Note that standard conditions may be revised, so should be confirmed individually.) Name No. (Year/month of inception) Type* Mainly used for: Temp ( C) RH (%) Example test conditions Test duration (hours) IEC (International 60068-2-66 (1994/06) 60749-4 (2002/4) Compact electric/electronic components (mainly non-hermetically sealed components) Semiconductors I II III 110 85 96 192 408 120 85 48 96 192 130 85 24 48 96 130 85 96 110 85 264 22-A102-C (2008/6) S Evaluating humidity resistance of non-hermetically sealed semiconductor devices A B C D E F 121 100 24 48 96 168 240 336 JESD (JEDE S industrial 22-A110C (2009/1) Evaluating reliability of non-hermetically sealed semiconductor devices (with voltage application) 130 85 96 110 85 264 22-A118 (2008/6) Evaluating reliability of non-hermetically sealed semiconductor devices (without voltage application) 130 85 96 A 110 85 264 B I II III JIS (Japanese industrial C60068-2-66 (2001/11) Compact electronic components (mainly non-hermetically sealed components) 110 85 96 192 408 120 85 48 96 192 130 85 24 48 96 JEITA (Japanese domestic industrial ED-4701/100 Method 103 (2001/8) Evaluating durability of semiconductor devices used or stored in high-temperature/ high-humidity atmospheres 110 85 192 120 85 96 130 85 48 *: unsaturated; S: saturated 2

HAST ((Hiighlly Accelleratted Sttress Testt)) HAST Control Methods Espec s HAST control methods are wet-and-dry bulb temperature control, unsaturated control and wetting saturation control. Wet-and-dry bulb temperature control measures and controls the test chamber temperature and humidity directly with a wet-and-dry bulb temperature sensor. Wetting saturation control and unsaturated control are used for testing under a condition of 100% relative humidity. The mechanism by which condensation forms on the test sample varies according to the control method. When using wetting saturation control for testing under a condition of 100% relative humidity, the test chamber heater is turned off, and only the humidifying heater is controlled. The environment resembles water being boiled in an airless atmosphere. When using unsaturated control, the test chamber heater being on causes a slight inclination toward unsaturation. The figure verified by ESPEC is about 98% (with no test sample in the chamber). Whether condensation forms on the test sample surface will be determined by the type of test sample, and the humidity during the temperature/humidity rise and fall. For this reason, common standards besides JEDEC (such as IEC and JIS) specify only relative humidity of 85%. We therefore recommend using test chambers only with full-condensation wetting saturation control, or wet-and-dry bulb temperature control. Pressure vessel Inner cylinder Test chamber heater Temperature sensor in chamber Door Air flow direction Cross-wick (provided on M (multitype) models) Agitating fan Test sample Humidifying water Agitating fan motor Humidifying heater Wet bulb temperature sensor (provided on M (multitype) models) Humidifying temperature sensor Figure 1 HAST test chamber structure 3

HAST ((Hiighlly Accelleratted Sttress Testt)) For 25 C/60% RH Environment Below is a conceptual diagram of a constant temperature/humidity chamber. The relative humidity in a constant temperature/humidity chamber is defined by the formula below. The water vapor pressure in the chamber is measured by a wet-and-dry bulb thermometer. This instrument works on the principle that the evaporation rate of water varies according to the quantity of water vapor in the surrounding gas. It measures the wet bulb temperature, a different measurement of humidity from dew point (except when the humidity is 100%). Relative humidity in a constant temperature/humidity chamber (25 C/60% RH) 25 C/60% RH 25 C/100% RH Water molecule Air Temperature in chamber: 25 C Water vapor pressure: 1.9 kpa Dry bulb 25 C Wet bulb 19.5 C (When air flow speed is 2.5 m/s.) Temperature in chamber: 25 C saturated moist air: About 3.2 kpa RH (%) = Mole fraction of water in moist air Mole fraction of water in saturated moist air 100 = moist air saturated moist air 100 moist air Saturated water vapor pressure of water 100 = 1.9 kpa 3.2 kpa 100 = 60% Strictly speaking, a coefficient should be inserted to compensate for interactions between molecules of gaseous water and air, but since the total pressure is about 1 atmosphere, the interactions can be ignored. Figure 2 Constant temperature/humidity chamber relative humidity schematic diagram A 4

Conceptt off Rellattiive Humiidiitty iin a Consttantt Temperatture//Humiidiitty Chamber For 85 C/85% RH Environment In an 85 C/85% RH environment, the water vapor partial pressure and air partial pressure are each about 50 kpa. Relative humidity in a constant temperature/humidity chamber (85 C/85% RH) 85 C/85% RH 85 C/100% RH Water molecule Air Temperature in chamber: 85 C Water vapor pressure: 49.1 kpa Dry bulb 85 C Wet bulb 81 C (When air flow speed is 2.5 m/s.) Temperature in chamber: 85 C saturated moist air: About 57.8 kpa RH (%) = Mole fraction of water in moist air Mole fraction of water in saturated moist air 100 = moist air saturated moist air 100 moist air Saturated water vapor pressure of water 100 = 49.1 kpa 57.8 kpa 100 = 85% Strictly speaking, a coefficient should be inserted to compensate for interactions between molecules of gaseous water and air, but since the total pressure is about 1 atmosphere, the interactions can be ignored. Figure 3 Constant temperature/humidity chamber relative humidity schematic diagram B 5

HAST Rellattiive Humiidiitty Conceptt For 120 C/85% RH Environment nder these conditions, the HAST environment resembles water being boiled in an airtight space. The HAST relative humidity is defined by the formula below in IEC 60068-2-66. The water vapor pressure in the chamber is calculated by measuring the humidifying water temperature or wet bulb temperature, and considering that temperature to be the same as the dew point. This method assumes that the test space is filled only with water vapor. It has been shown experimentally that the humidifying water temperature, wet bulb temperature and dew point are roughly the same in a stable-period HAST environment of high temperature, humidity and pressure. HAST relative humidity (120 C/85% RH) Water molecule 120 C/85% RH Temperature in chamber: 120 C Water vapor pressure: 168.7 kpa Dry bulb 120 C 120 C/100% RH Temperature in chamber: 120 C Saturated water vapor pressure: 198.5 kpa Humidifying water 115 C Wet bulb 115 C Humidifying water 120 C Heating Heating RH (%) = Water vapor pressure of moist air Saturated water vapor pressure of water 100 = 168.7 kpa 198.5 kpa 100 = 85% Figure 4 HAST relative humidity schematic diagram 6