Technichal Description

Similar documents
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Preset Counter signo 721

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Combi switchbox with integrated 3/2 way pilot valve

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

RY2 miniature industrial relays

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Modular I/O System Analog and Digital Interface Modules

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Cable Plug acc. to DIN EN , Form A

Electronic Pressure Switch EDS 300

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Combi B Alarm box. Mounting instructions

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Safety technique. Emergency stop module BO 5988 safemaster

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

SKR - industry relay

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

How To Read A Pipe From A Sensor

Units PSENmag. PSEN 2.2p Unit features. Function description

Install the DeviceNet Module using the following procedure:

Busch-Watchdog Presence EIB Type:

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

RS - SPM. Serial parallel translator module

Actuator-Sensor-Interface

Push button 3gang standard flush-mounted xx

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Smart DeviceNet Remote I/O Terminals

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

IMR 6000/10../20../30

FP2 Relay. The Best Relaytion

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

BATRON. Specification for BTHQ 21605V-FSTF-I2C-COG

LCM Design Engineering SPECIFICATION FOR LCD MODULE TYPE ITEM NO.: MDLS MDLS16265-LV-G-LED04G (BB) (DOC. REVISION 1.0)

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

Disturbance Recoder SPCR 8C27. Product Guide

Monitor and control the sensors through network. supported OPTEX FA CO., LTD. Remote controlling of fiber sensors. Reduces wires and saves space

HYDRUS ULTRASONIC METER

Technical Data. Dimensions

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Original instructions Tina 3A/Aps Adaptor unit

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

LUT Luminescence scanners: Seeing what no-one else can

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

ABB i-bus EIB Logic Module LM/S 1.1

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Repeaters and Mimics Data Sheet

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

PLUTO Safety-PLC. Manual Absolute Encoders

Telephone- and leased line modem for industrial applications TD-36

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

FOR MORE INFORMATION or from a non-telstra phone and say pre-paid telstra.com/ppmbb visit a telstra store or partner

Pluggable interface relays CR-P Pcb relays

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

3-phase, bidirectional energy meter

E-STOP relays, safety gate monitors

AC3200 INTELLIGENT BROADBAND AMPLIFIER

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Solid-State Timer H3G

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Thermal-Magnetic Circuit Breaker M1-..

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

NC-12 Modbus Application

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Contact expansion modules

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G USB + WI-FI

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

Capacitive Prox E2K-X

Digital Pressure Measuring Instrument MDR480

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Transcription:

Technichal Description Content 1. General...1 2. Block Diagram...2 3. Use of the Z Plug...2 4. Technical Data...4 4.1 AS-Interface...4 4.2 M12 pin out...5 4.3 Undervoltage detection...5 4.4 Mechanical and Environmental Data...5 5. Standards...6 1. General The AS-Interface Z Plug AI010 is a slave of the fieldbus system AS-Interface. It serves as network extension utility for networks with up to 200m length without repeaters. Previously only 100m network lengths were possible. Its profile is S-B.A.*.E (2 inputs and 2 outputs). The AS-Interface Z Plug AI010 can furthermore be used as indicator for undervoltage detection. If the AS-Interface supply voltage is within the specified level both inputs D2 and D3 are set. If the supply voltage drops below the lower limit of the specified voltage range the inputs are reset accordingly. Thus a reliable undervoltage detection for the network can be established. Rev. 2, 25.10.2006 Page 1 of 6

Technical Description AS-Interface Z Plug 2. Block Diagram Block Diagram of the AS-Interface Z Plug 3. Use of the Z Plug The AS-Interface Z Plug AI010 can be utilised to extend AS-Interface networks beyond the limit of 100m. With it's help it is possible to double network length to up to 200m without repeaters. In standard networks, where signal quality is below average due to full load or use of non standard network cable it may be possible to reduce telegram error rates with the insertion of the Z Plug. Furthermore the Z Plug has an integrated undervoltage detection circuit that signals a voltage within the specification or below specification via 2 input bits of an AS-Interface slave that is integrated in the Z Plug. Use to extend network length If the AS-Interface Z Plug AI010 is to be used to extend network length, the following installation rule has to be observed: The Z Plug is to be installed at the point in the network that has the longest distance to the AS-Interface power supply unit. It is not necessary to hit this point exactly, a deviation of ±10m is tolerable. Only one Z Plug per network shall be installed. Page 2 of 6 Rev. 2, 25.10.2006

Technichal Description If repeaters are used, one Z Plug per network segment is needed, if it is longer than 100m. Due to longer signal delay times in networks with more than 100m length it is not possible to install two repeaters in series. The possibility to extend AS-Interface networks as described above also exists for networks where AS-Interface Safety at Work products are installed. The properties of AS-Interface networks without and with Z Plug are summarised in the following table: criterion without Z Plug with Z Plug max. number of slaves 62 62 possible network structures max. distance Master-Slave without (with) repeaters max. distance Slave-Slave without (with) repeaters star, ring, line, line with taps, tree 100m (300m with two repeaters in series) 100m (500m) star, ring, line, line with taps, tree 200m (400m with one repeater) 200m (600m) use for AS-Interface signal quality improvement If in networks with up to 100m length the telegram error rate is higher than tolerable and if this high telegram error rate is due to a high load of the network and/or a non standard cable in use then the installation of a Z Plug may improve the network communication significantly. This is also true for networks where Safety at Work products are connected. The same installation rules as above apply. use for undervoltage detection At the most distant point in the network the probability is highest that the voltage drop along the line is such that the supply voltage level drops below the lower specified limit. This is particularly the case in networks with a length of up to 200m. The AS-Interface Z Plug AI010, therefore, is equipped with an undervoltage detection circuit that signals a supply voltage below the specified limit by resetting the slave inputs D2 and D3. The detection circuit is designed in such a way that even short undervoltage dips (e.g. in case a high power actuator changes it's state or slip rings have intermittent contact problems) are detected and indicated clearly. Two undervoltage detection voltages are selectable: 26,0V and 22,5V. They are selected via the slave output D1. Input D3 is reset in case the undervoltage dip detected has a duration of more than 5ms. Additionally the input D2 is reset if the duration of the undervoltage situation is Rev. 2, 25.10.2006 Page 3 of 6

Technical Description longer than 50ms. If an input has been resetted it will stay in that state for at least 100ms even if the undervoltage dip was shorter. If the voltage drops below 20V for a longer period of time the integrated AS-Interface IC will perform a reset; in this case the undervoltage signalisation cannot longer be maintained. 4. Technical Data 4.1 AS-Interface AS-Interface Profile: S-B.A.*.E (2 inputs and 2 outputs) reverse voltage protection: yes Display "Power": --- Display "Fault": --- AS-Interface operating voltage range: approx. 20...31,6 V 1) max. current consumption: 18 ma power on delay time: < 1 s AS-Interface Specification: V2.11, V3.0 AS-Interface IC ASI-SW AS-Interface certificate: will be applied for 1) Readdressing the unit is possible in the voltage range 26.5... 31.6V only. The use of the data bits is shown in the following table: Input Data Image (IDI): Info (Interface 3) Bit 4 (DI3) Bit 3 (DI2) Bit 2 (DI1) Bit 1 (DI0) 0 U-voltg. >5ms U-voltg. >50ms --- --- 1 voltage ok voltage ok --- --- Output Data Image (ODI): Info (Interface 3) Bit 4 (DO3) Bit 3 (DO2) Bit 2 (DO1) Bit 1 (DO0) 0 --- --- Uswitch < 26,0V --- 1 --- --- Uswitch < 22,5V --- Page 4 of 6 Rev. 2, 25.10.2006

Technichal Description 4.2 M12 pin out Pin 1: A+ Pin 3: A- For the installation of the Z-Plug on the AS-Interface flat cable an accessory flat cable connector (ICS Art. No. ZS006) is available. 4.3 Undervoltage detection switching point: switching point over temperature range: minimum duration of undervoltage dip: 26,0V ±0,2V or 22,5 ±0,3V (selectable) 26,0V ±0,5V oder 22,5V ±0,5V 5ms or 50ms resp. minimum duration of undervoltage signal: 100ms 4.4 Mechanical and Environmental Data ambient operating temperature range: -25... 70 C protection rating: IP67 max. vibration level (temporarily): 1,5mm Amplitude (10..55Hz) max. shock: 10g All dimensions in mm Rev. 2, 25.10.2006 Page 5 of 6

Technical Description M12 plug according to type JM (IEC 61076-2-101) 5. Standards IEC 62026-2:2000 This product is designed and manufactured for industrial applications and is not suitable for sale to the general public. Page 6 of 6 Rev. 2, 25.10.2006