G657 fibres and how to splice them

Similar documents
SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Transmission media and optical systems characteristics Optical fibre cables

Explanation of Reflection Features in Optical Fiber as Sometimes Observed in OTDR Measurement Traces

Fiber Optic Specifications

OFS AllWave Zero Water Peak (ZWP) single-mode

Fiber Optics: Fiber Basics

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Transmission media and optical systems characteristics Optical fibre cables

Next Generation Optical Fibre: Making Your Broadband Network Go Further

Splicing and Fiber Assembly Compatibility for Non-Zero Dispersion-Shifted Fiber and Standard Single-Mode Fiber

BOTDR Measurement Techniques and Brillouin Backscatter Characteristics of Corning Single-Mode Optical Fibers

Module 13 : Measurements on Fiber Optic Systems

Lecture 3: Fibre Optics

Properties and Potential Applications of a Bend Optimised Singlemode Optical Fibre

ITU-T G.652. Characteristics of a single-mode optical fibre cable

Optical Fibers Fiber Optic Cables Indoor/Outdoor

200-Micron Single-Mode Fiber Enables New Cable Designs Copyright 2014 OFS FITEL, LLC

Compatibility of Bend Optimized Multimode Fibers White Paper. Issued September 2009

Fundamentals of Optical Communications

SPLICE LOSS IN NON-ZERO DISPERSION-SHIFTED FIBERS

GOSN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection. Ordering Information. Applications. Features & Benefits

Field Measurements of Deployed Fiber

Optical Fiber. Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network

GOWN. Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection. Ordering Information.

Fiber Selection and Standards Guide for Premises Networks

FIBRA OPTICA INTERIOR/EXTERIOR TIGHT BUFFER

Service Description blizznetdarkfiber

Attenuation: Bending Loss

Single or Dual Fiber for 100 Mbps over SMF?

Designing Fiber Optic Systems David Strachan

Measuring of optical output and attenuation

Corning Specialty Fiber. Product Information Sheets

GOSB. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection. Ordering Information. Applications. Features & Benefits

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)

Cisco - Calculating the Maximum Attenuation for Optical Fiber Links

Fibre Channel Fiber Cabling

What are Fibre Optics?

Microbend evaluation of selected G652D & G657 fibers and ribbons before cabling

An Overview of Macrobending and Microbending of Optical Fibers

Wavelength Division Multiplexing

Fiber Optic Cordage. Interconnect A Furukawa Company. Product Description. Why OFS Interconnect Cordage?

The Conversion Technology Experts. Fiber Optics Basics

Simulation of Gaussian Pulses Propagation Through Single Mode Optical Fiber Using MATLAB . MATLAB

MTS/T-BERD Platforms Very Long Range (VLR) OTDR Module

Industry solutions: Broad cast

ESPECIFICACIÓN DE PRODUCTO

Introduction to Optical Link Design

Radiation-Resistant Single-Mode Optical Fibers

Next Breakthrough Technologies: Trends in Datacenter for 100G and Beyond. Durgesh S Vaidya May 9, 2014

OPTICAL FIBER CABLES

SECTION 680 FIBER OPTIC CABLE DESCRIPTION

Standard attenuation and extra low loss POF cables are identical except for attenuation specifications.

The following terms are defined within the context of the fiber optic industry

New Direct Core Monitoring Fusion Splicer TYPE-71C+

INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet.

FIBER-OPTIC CABLES LWL-KABEL

Understanding and Optimizing MDU Optical Cabling Systems

Fiber Optic Training Guide By Sarkis Abrahamian

Removing the Mystery from OTDR Measurements. Keith Foord Product Manager Greenlee Communications

Enabling 21 st Century Connectivity

Attaching the PA-A1-ATM Interface Cables

An advanced Dark Fiber Monitoring System for Next Generation Optical Access Networks

SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS

Data Storage (Splicing result) Storage Condition

MINIMIZING PMD IN CABLED FIBERS. Critical for Current and Future Network Applications

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

Fibre Optic Indoor/Outdoor Cable

Different Types of Dispersions in an Optical Fiber

Design of Ultra-High-Density 2000-Optical Fiber Cable with Pliable 8-fiber Ribbons for Underground Deployment

SINGLE MODE OPTICAL FIBER FTTH CABLE

Discontinued. Volition. Fiber Optic Cable. 3Innovation

home site map help ECMS Project: Standard / Federal Oversight Advertised

EE4367 Telecom. Switching & Transmission. Prof. Murat Torlak

FIBER OPTIC COMMUNICATIONS. Optical Fibers

Table of Contents. Introduction...3 Fiber Advantages...3 Fiber Cable Structure...4 Multi-Mode Fiber...4 Single-Mode Fiber...5 Wavelengths...

Infrared Optical Fiber. Datasheets and Price list. JTIngram Sales and Marketing

Low loss fiber to chip connection system for telecommunication devices

Smart Cabling: Constructing a cost effective reliable and upgradeable cable infrastructure for your data centre/enterprise network

Optical fiber basics in a nutshell

LIEKKI. Optical Fibers. Features. Applications

Accurately Testing fibre Optic Cables

288 Fiber Ultra-High Fiber Density Micro-Duct Cable with Extreme Operating Performance

Procedure for Cutting and Respooling Fiber Optic Cable

Addendum #1. RFP No Fiber Maintenance RFP 11/18/2011

Attenuator Integrated With Input Tap (voltage control)

Optical transmission systems over Plastic Optical Fiber (POF) at high bit rate

Plastic Optical Fiber for In-Home communication systems

Effect of ageing conditions on performance properties of selected commercial fibers

TransPacket white paper. CWDM and DWDM networking. Increasing fibre-optical network utilization and saving on switches/routers

Data Sheet. HFBR-RXXYYYZ Series (POF) HFBR-EXXYYYZ Series (POF) Plastic Optical Fiber Cable and Accessories for Versatile Link.

FIBER OPTIC SYSTEM TEST PROCEDURES

Direct Attach Cable with Micro Coaxial Wire for Data Center

Cabling & Test Considerations for 10 Gigabit Ethernet LAN

How To Read A Fiber Optic Sensor

How To Get A Better Signal From A Fiber To A Coax Cable

Ethernet/IEEE evolution

Photonic components for signal routing in optical networks on chip

Technical Bulletin. Guidelines For Testing And Troubleshooting Fiber Optic Installations

OPTICAL CABLES FIG8 OPTICAL CABLE ADSS OPTICAL CABLE. Environmental performance. Environmental performance AVAILABLE MODELS. Temperature Performance

As today s evolving data centers

7.4 3M No Polish Connector

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

Transcription:

G657 fibres and how to splice them Sumitomo Electric Europe PureAccess, ClearCurve, AllWave, CasaLight, EZ-Bend, BendBright and their derived product names are acknowledged trademarks of their respective manufacturers. Author of the lecture - David Randall Issue 2.0 Sumitomo Electric 2011 1

What is a G657 fibre? G657 is a new class of single mode fibre which can be bent more severely than normal G652 fibre without losing the signal. The ITU defines 4 classes of G657 fibre as below... G657A1 10mm minimum bend radius, other specs as G652 G657A2 7.5mm minimum bend radius, other specs as G652 G657B2 7.5mm minimum bend radius, other specs may deviate from G652 G657B3 5mm minimum bend radius, other specs may deviate from G652 Issue 2.0 Sumitomo Electric 2011 2

Compatibility to G652.D Parameter G657.A G657.B MFD 8.6-9.5 um 6.3-9.5 um attenuation coefficient at 1310nm 0.4dB/km 0.5dB/km attenuation coefficient at 1550nm 0.3dB/km 0.3dB/km wavelength limit (cable cut-off) 1260 nm 1260 nm chromatic dispersion G652.D TBD PMD G652.D TBD Issue 2.0 Sumitomo Electric 2011 3

G 657 bend insensitivity comparison Fibre class A1 A2 B2 A1 A2 B2 B3 A2 B2 B3 B3 Bending radius [mm] 15 10 7,5 5 Number of loops 10 10 10 1 1 1 10 1 1 1 1 Max. attenuation at 1550 nm [db] 0,25 0,03 0,03 0,75 0,1 0,1 0,03 0,5 0,5 0,08 0,15 Max. attenuation at 1625 nm [db] 1 0,1 0,1 1,5 0,2 0,2 0,1 1,0 1,0 0,25 0,45 Issue 2.0 Sumitomo Electric 2011 4

What are the G657 fibres required to withstand? Issue 2.0 Sumitomo Electric 2011 5

How does a G657 fibre work? G657A fibres often have a design similar to G652D may have a slightly taller, thinner core some A2 types have a trench around the core Sumitomo s PureAccess[A2] has no trench G657B fibres adopt different designs to G652 Trench around the core Trench and ring around the core Voids around the core The structure around the core changes the power distribution and more strongly guides the light Issue 2.0 Sumitomo Electric 2011 6

G652 refractive index profile G652 refractive index profile n -100-50 0 50 100 um Issue 2.0 Sumitomo Electric 2011 7

G657 - taller thinner core design G657 Tall / Thin type n -100-50 0 50 100 um Issue 2.0 Sumitomo Electric 2011 8

G657 trench around the core design G657 Trench type n -100-50 0 50 100 um Issue 2.0 Sumitomo Electric 2011 9

G657 ring + trench around the core design G657 Trench / Ring type n -100-50 0 50 100 um Issue 2.0 Sumitomo Electric 2011 10

G657 voids around the core design G657 Void Assisted type n -100-50 0 50 100 um Issue 2.0 Sumitomo Electric 2011 11

Who makes these fibres? Sumitomo PureAccess Ultra released 2004 Pioneering design with a tall, very thin core 7.5mm allowable bend radius Released before ITU defined G657 Poor G652 compatibility due to MFD mismatch No longer in production Sumitomo PureAccess released 2004 10mm allowable bend radius Released before ITU defined G657 Now classed as G657A1 More than 7M km delivered Issue 2.0 Sumitomo Electric 2011 12

Designs, manufacturers, classes Design Producer G657A1 G657A2 G657B2 G657B3 Tall/thin core Sumitomo PureAccess PureAccessA2 Tall/thin core Corning ClearCurve XB Tall/thin core OFS AllWave Flex Tall/thin core Prysmian CasaLight Trench Sumitomo PureAccess R5 Trench Draka BendBright BendBright XS BendBright Elite Trench + ring OFS EZ-Bend Trench Corning ClearCurve LBL ClearCurve ZBL Voids Prysmian CasaLight Plus CasaLight Xtreme Issue 2.0 Sumitomo Electric 2011 13

Corning ClearCurve has changed The original ClearCurve was a G657.B3 fibre using a Void Assisted Fibre (VAF) design. It had a ring of tiny holes or nano-structures around the core to achieve B3 level bending performance. Sumitomo developed a T-39 splice program for VAF type ClearCurve This program collapsed the voids, to make the core visible for alignment It s available from software versions 1.29, 1.49 and 1.69 onwards In 2010 Corning withdrew the original design of ClearCurve from the market. Their present G657 product line up includes... G657.A1 ClearCurve XB Tall/thin core type G657.A2 ClearCurve LBL Trench type G657.B3 ClearCurve ZBL Trench type Issue 2.0 Sumitomo Electric 2011 14

New ClearCurve x Original ClearCurve New ClearCurve ZBL on the left, original type on the right Issue 2.0 Sumitomo Electric 2011 15

What are the issues in splicing these fibres? MFD mismatch with G652 Increased loss when MFD is not the same as G652D Mode profile mismatch with G652 Non-Gaussian mode profiles (power distribution) Different melting point to G652 Extra dopants may alter the melting point Evolving designs Manufacturers are still improving their G657 fibre designs. Changes to their design can affect splice-ability Issue 2.0 Sumitomo Electric 2011 16

Using a fixed v-groove splicer Fixed v-groove splicers cannot image the core They don t care the core differs from a G652 The only consideration is the correct melting point How to splice using T-25e or T-66? Choose SMF Standard program Make an Arc Test Start splicing Issue 2.0 Sumitomo Electric 2011 17

Using a core aligning splicer Core aligning splicers must process the core image to make a core alignment Extra structure around the core can distort or shield the core image G657B, and some G657.A2 core images differ from a G652 core and may need a special processing algorithm. Issue 2.0 Sumitomo Electric 2011 18

Using a Sumitomo T-39 splicer Sumitomo has worked with other fibre manufacturers to create & test splice programs for commonly available G657 fibres T-39 has Core Alignment splice programs for current G657 fibres made by Prysmian, Corning, OFS & Draka- Comteq and of course, Sumitomo fibres T-39 s AUTO and BIF Adaptive programs can also be used for G657 splicing. They attempt a Core Alignment splice, if this isn t possible, they revert to Diameter Alignment. Issue 2.0 Sumitomo Electric 2011 19

Examples of Core Alignment splices The following slides show T-39 Core Alignment splices of various G657 fibres Issue 2.0 Sumitomo Electric 2011 20

ClearCurve ZBL x ClearCurve ZBL on T-39 Issue 2.0 Sumitomo Electric 2011 21

ClearCurve ZBL x G652 on T-39 Issue 2.0 Sumitomo Electric 2011 22

EZ-Bend x G652 on T-39 Issue 2.0 Sumitomo Electric 2011 23

BendBright XS x G652 on T-39 Issue 2.0 Sumitomo Electric 2011 24

BendBright-Elite x G652 on T-39 Issue 2.0 Sumitomo Electric 2011 25

BendBright XS x BendBright-Elite on T-39 Issue 2.0 Sumitomo Electric 2011 26

CasaLight-Plus x CasaLight-Plus on T-39 Initially the core image is shielded by the cladding voids Issue 2.0 Sumitomo Electric 2011 27

CasaLight-Plus x CasaLight-Plus on T-39 T-39 collapses the voids so it can see the core Issue 2.0 Sumitomo Electric 2011 28

CasaLight-Plus x CasaLight-Plus on T-39 Finished splice Issue 2.0 Sumitomo Electric 2011 29

CasaLight-Plus x G652 on T-39 CasaLight-Plus on the left, G652 on the right Issue 2.0 Sumitomo Electric 2011 30

CasaLight-Plus x G652 on T-39 T-39 collapses the voids to image the core of the CasaLight Issue 2.0 Sumitomo Electric 2011 31

CasaLight-Plus x G652 on T-39 Finished splice Issue 2.0 Sumitomo Electric 2011 32

PureAccess[R5] x PureAccess[R5] on T-39 Issue 2.0 Sumitomo Electric 2011 33

PureAccess[R5] x G652 on T-39 Issue 2.0 Sumitomo Electric 2011 34

PureAccess[A2] x PureAccess[A2] on T-39 Issue 2.0 Sumitomo Electric 2011 35

PureAccess[A2] x G652 on T-39 Issue 2.0 Sumitomo Electric 2011 36

Let s go ahead with G657! Thank you for your attention. Issue 2.0 Sumitomo Electric 2011 37