Introduction to Hospital accelerators

Similar documents
Tom Wilson Product Marketing Manager Delivery Systems Varian Medical Systems International AG. CERN Accelerator School, May 2015

Introduction to Hospital accelerators. Lars Hjorth Præstegaard, Ph.D. Technical manager Medical physicist Aarhus University Hospital

Overview of Proton Beam Cancer Therapy with Basic Economic Considerations

Feasibility Study of Neutron Dose for Real Time Image Guided. Proton Therapy: A Monte Carlo Study

ACCELERATORS AND MEDICAL PHYSICS 2

Advanced variance reduction techniques applied to Monte Carlo simulation of linacs

Chapter 5 TREATMENT MACHINES FOR EXTERNAL BEAM RADIOTHERAPY

Digital vs. Analogue Control Systems

Medical Applications of radiation physics. Riccardo Faccini Universita di Roma La Sapienza

Clinical Photon Beams

World-first Proton Pencil Beam Scanning System with FDA Clearance

MLC Characteristics. Treatment Delivery Systems 2 Field Shaping; Design Characteristics and Dosimetry Issues. Presentation Outline

In room Magnetic Resonance Imaging guided Radiotherapy (MRIgRT( MRIgRT) Jan Lagendijk and Bas Raaymakers

HITACHI Proton Beam Therapy System

Development of on line monitor detectors used for clinical routine in proton and ion therapy

Scripps Proton Therapy Center: Configuration and Implementation

Proton Radiotherapy. Cynthia Keppel Scientific and Technical Director Hampton University Proton Therapy Institute. Lead Virginia.

Secondary Neutrons in Proton and Ion Therapy

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

IBA Proton Therapy. Biomed days Vincent Bossier. System Architect Protect, Enhance and Save Lives

Cathode Ray Tube. Introduction. Functional principle

Proton therapy, yesterday, today and tomorrow

1. Orthovoltage vs. megavoltage x-rays. (AL) External beam radiation sources: Orthovoltage radiotherapy: kv range

Proton Therapy - Frequently Asked Questions For Clinicians

Results: Low current ( ) Worst case: 800 MHz, GeV, 4 turns Energy oscillation amplitude 154 MeV, where

A new extraction system for the upgraded AIC-144 cyclotron

Gamma Knife and Axesse Radiosurgery

Radiation Strip Thickness Measurement Systems

Variance reduction techniques used in BEAMnrc

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS

Chapter 27 Magnetic Field and Magnetic Forces

Current Status and Future Direction of Proton Beam Therapy

HADRON THERAPY FOR CANCER TREATMENT

Precise Treatment System Clinically Flexible Digital Linear Accelerator. Personalized radiotherapy solutions for everyday treatment care

Charged Particle in a Magnetic Field

Status of Radiation Safety System at

MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM

Seminar 7. Medical application of radioisotopes - radiotherapy

Radiation therapy involves using many terms you may have never heard before. Below is a list of words you could hear during your treatment.

Proton beam. Medical Technical Complex Joint Institute for Nuclear Research, Dubna, Russia

Clinical Physics. Dr/Aida Radwan Assistant Professor of Medical Physics Umm El-Qura University

View of ΣIGMA TM (Ref. 1)

The accurate calibration of all detectors is crucial for the subsequent data

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

3D SCANNER. 3D Scanning Comes Full Circle. Your Most Valuable QA and Dosimetry Tools

Post Treatment Log File Based QA Varian. Krishni Wijesooriya, PhD University of Virginia. D e p a r t m e n t of R a d i a t i o n O n c o l o g y

THE DOSIMETRIC EFFECTS OF

Atomic and Nuclear Physics Laboratory (Physics 4780)

CHAPTER 10. ACCEPTANCE TESTS AND COMMISSIONING MEASUREMENTS

Potential Benefits of Proton Therapy in Clinic

QA of intensity-modulated beams using dynamic MLC log files

Cyclotron Centre in Poland and 2D thermoluminescence dosimetry

1. Units of a magnetic field might be: A. C m/s B. C s/m C. C/kg D. kg/c s E. N/C m ans: D

Chapter 8 ELECTRON BEAMS: PHYSICAL AND CLINICAL ASPECTS

ADROTERAPIA A MEDAUSTRON

RapidArc QA Program in Prince of Wales Hospital. Michael L. M. Cheung, Physicist Prince of Wales Hospital Hong Kong

Zero Degree Extraction using an Electrostatic Separator

Principles of radiation therapy

HIGH CURRENT OPERATION OF THE ACSI TR30 CYCLOTRON

Therapy with protons and ion beams

NIA RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

Mission: Cure, Research and Teaching. Marco Pullia Cnao design and commissioning

Dose delivery and treatment planning methods for efficient radiation therapy with laser-driven particle beams

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission

Institute of Accelerator Technologies of Ankara University and TARLA Facility

Magnetic Field and Magnetic Forces

4D Scanning. Image Guided Radiation Therapy. Outline. A Simplified View of the RT Process. Outline. Steve B. Jiang, Ph.D.

Coupling Impedance of SIS18 and SIS100 beampipe CERN-GSI-Webmeeting

Principles of Ion Implant

Proton Therapy Center at the Institute of Nuclear Physics in Kraków - from the Eye Treatment to the Scanning Gantry

RF SYSTEM FOR VEPP-5 DAMPING RING

Contents. X-ray and Computed Tomography. Characterization of X-rays. Production of X-rays

K O M A C. Beam Commissioning of 100-MeV KOMAC Linac. Korea Multi-purpose Accelerator Complex 양 성 자 가 속 기 연 구 센 터

Dosimetric impact of the 160 MLC on head and neck IMRT treatments

CHAPTER D1 ION OPTICS OF MAGNETIC/ELECTRIC SECTOR MS

Reliability and Availability Aspects of. the IPHI Project

How To Understand Light And Color

Information about the T9 beam line and experimental facilities

OBJECTIVE OUTLINE PHOTONEUTRON PRODUCTION

First Three Years After Project Proton Therapy Facility:

How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer

2. Orbits. FER-Zagreb, Satellite communication systems 2011/12

Evolution of Head and Neck Treatment Using Protons. Mayank Amin, M.Sc,CMD

2015 ASTRO INVESTOR MEETING. October 20, 2015

IMPT Intensity Modulated Proton Therapy

The Science behind Proton Beam Therapy

Horizon Blue Cross Blue Shield of New Jersey 2012 Radiation Therapy Payment Rules

Activities at the University of Frankfurt (IAP)

Total Solutions. Best NOMOS One Best Drive, Pittsburgh, PA USA phone NOMOS

An octave bandwidth dipole antenna

Force on Moving Charges in a Magnetic Field

Intensity-Modulated Radiation Therapy (IMRT)

How To Use A Proton For Radiation Therapy

Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies

Cancer Therapy with Particle Beams

Radiation Oncology Centers Participating in MassHealth. Daniel Tsai, Assistant Secretary and Director of MassHealth

Corporate Medical Policy

Transcription:

Introduction to Hospital accelerators Lars Hjorth Præstegaard Aarhus University Hospital Outline Electron linacs for radiotherapy: Overview Beam transport How to change the energy? Treatment head design Medical cyclotrons: Basic principles Applications 1

Overview of electron linacs for radiotherapy Main components Acceleration structure Bending magnet Microwave amplifier Electron gun Gantry Treatment head Couch Waveguide 2

Gantry and couch degrees of freedom Gantry Collimator Isocenter: Intersection of gantry rotational axis and collimator rotational axis Couch Main manufacturers of medical linacs Elekta Varian 4-22 MeV TW accelerator 4-22 MeV SW accelerator X-ray treatment: Fast electrons + target Intense bremsstrahlung (x-rays) Electron treatment: Fast electrons + scattering foil Spray of fast electrons 3

Beam transport Beam transport in electron medical linac Goals: 1. Transport of beam from linac to target/foil 2. Small beam spot at target/foil Linac Target Bending magnet Solenoid x-rays 4

Bending magnet: Concepts Chromatic deflection Achromatic deflection Large beam spot Varian / Siemens HE Provides a small isocenter height Achromatic deflection Elekta Varian (low energy) Bending magnet: Varian Clinac HE Coil Magnet poles 5

Bending magnet: Varian Clinac HE Energy slit: Slit at position with nonzero dispersion Target How to change beam energy of linac for radiotherapy? 6

Frenkvens Frekvens Change of RF input power Change of RF input power Change of the electric field Change of the energy, capture efficiency, and energy spread Only optimum capture efficiency and energy spread for a particular RF input power (beam energy) Problem for multi-energy linac Design compromise 0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 Siemens SW linac: 6 MeV Large energy spread Capture efficiency: 36% Small percentage of electrons reach the target Low dose rate + stray rad. 0.00 0.0 0.2 0.4 0.6 0.8 1.0 Accelerations-effektivitet 0.10 0.08 0.06 0.04 0.02 Siemens linac SW : 18 MeV Small energy spread Capture efficiency: 44% Large percentage of electron reach the target 0.00 0.0 0.2 0.4 0.6 0.8 1.0 Accelerations-effektivitet Change of RF frequency t 2 Buncher t 1 Elekta Synergy TW accelerator RF frequency shift Change of phase velocity Desynchronization of wave and particle Particle energy decrease Only small change of effective electric field in the buncher section Design of optimum capture efficiency and energy spread for a wide range of beam energies. High dose rate for all treatment energies Used for Elekta TW accelerator 7

Change of number of active cells Motorized energy switch: Modification of cavity coupling Varian Clinac Buncher +RF input Reduced electric field Same electric field in buncher for all beam energies Design of optimum capture efficiency and energy spread for wide range of beam energies Efficient transfer of electrons from gun to target for all energies High dose rate for all energies Change of input beam current Change of input beam current Change of beam loading Change of the electric field: SW accelerator: TW accelerator: Change of energy Change of capture efficiency and energy spread Change of energy No change of capture efficiency and energy spread Input beam current used for energy feedback loop for Elekta TW accelerator 8

Treatment head design Varian Clinac treatment head Flattening filters Target Dual monitor chamber Secondary collimators 120 leaf multi-leaf collimator 9

X-ray target Varian Clinac x-ray target: X-ray target: Located inside vacuum Conversion of electron beam to bremsstrahlung (x-ray treatment) Target materials: Target materials affects x-ray yield and spectrum Copper/water for cooling 6 MeV bremsstrahlung spectrum: Primary collimator Primary collimator: Large tungsten block defining the maximum treatment field size Effective shielding of leakage radiation Usually opening with a conical shape Round maximum field size 10

X-ray flattening filter 1. Bremsstrahlung is forward-peaked 2. Convenient with flat dose profile Use flattening filter: Cancellation of off-axis intensity variation Reduction in dose rate Off-axis photon energy spectrum variation High energy Varian flattening filters: Low energy Monitor chamber Dual transmission ionization chamber: Determination of treatment beam dose Two chambers: Redundant dose determination TrueBeam dual transmission monitor chamber 11

Light field Light field = Extend of treatment field Secondary collimators (jaws) Varian secondary collimators (tungsten): Secondary collimators: 12

Multi-leaf collimator (MLC) MLC: 2 rows of thin tungsten blades Detailed shaping of the treatment field Typical leaf width: 5 mm MLC Varian 120 leaf MLC (leaf width: 5 mm) Photon cascade Water Compton scattering Low ionization (dose) at water surface = Dose buildup e - Pair production e - Photoelectric effect e + Bremsstrahlung e - e - Annihilation e + Photoelectric effect e - Photoelectric effect = Ionization 13

Relative dose X-ray depth dose curves 100 80 60 40 20 Dose buildup Depth of max. dose increases with energy Surface dose 25 % 6 MV 15 MV Decreasing dose: Attenuation + inverse square law 0 0 100 200 300 Depth (mm) Dose buildup provides skin sparing Electron treatment Detailed field shaping: Lead end-frame cut-out Elekta electron applicator 14

Relative dose Electron dose versus depth Ionization tracks (20 MeV electrons): Dose High ionization (dose) at surface Water Electron range depends on electron energy Depth Bremsstrahlung tail Electron depth dose curves 100 80 60 40 20 0 High dose at surface 0 20 40 60 80 100 120 Depth (mm) 6 MeV 9 MeV 12 MeV 15 MeV 18 MeV Peak for low energy: 1. Increase of electron fluence with depth (scattering ~ 1/E kin2 ) 2. Reduced radiation loss (less smear out of Bragg peak) Bremsstrahlung tail Electrons are used for treatment close to the skin (only 1 treatment field) 15

Example: 5 field prostate x-ray treatment Transverse view of patient pelvis Field 2 Field 1 Field 3 Prostate target Field 5 Field 4 Overlap of all fields at cancer target Large dose in cancer target relative to dose in healthy tissue Example: Intensity-modulated RT (IMRT) IMRT: Modulation of each field with MLC Dose distribution fits better to the cancer target 16

Imaging systems on-board accelerator Imaging systems Verification of patient position kv source on robotic arm MV radiation head MV detector on robotic arm KV detector on robotic arm Imaging systems: 2D MV imaging 2D KV imaging (good contrast) 2D KV imaging + gantry rotation: CT scanning of pt. in treatment position Medical cyclotrons for proton therapy and isotope production 17

The classical cyclotron Magnetic field Circular orbit Circular orbit: Centrifugal force = Magnetic Lorentz force mv r 2 evb z m: Mass of ion. q: Number of charges e: Elementary charge v: Speed of ion r: Radial position of ion B z : Magnetic field strength in the z direction z Angular frequency: rev v r eb m z eb z m 0 Gyro frequency or cyclotron frequency Typically 10-30 MHz 18

Isochronous cyclotron CW high intensity proton beam Simultaneous acceleration of low/high energy protons Revolution period should be energy independent (isochronous cyclotron) Isochronous cyclotron: eb z rev Constant m 0 c B z (r) = (r)b(0), r R rev Field increases versus r + r is limited Problem: Reduced orbit separation More difficult extraction Isochronous cyclotron Methods for increasing the field versus r: 1. Decreasing pole gab versus r 2. Trimming coils 3. Increase hill/valley ratio IBA C235 Isochronism: The magnet poles must be machined and shimmed with very high accuracy (relative field error below 10-4 ) 19

Transverse focusing Betatron tune: Number of oscillation periods per revolution Weak focusing: Less than one oscillation per revolution Strong focusing: More than one oscillation per revolution Cylindrical symmetric magnet pole: Radial betatron tune: r2 =1-n Vertical betatron tune: z2 =n n r B z B r z Both radial and vertical focusing r2 =1-n > 0 and z2 =n > 0 0<n<1 (weak focusing) Small field decrease versus r B r F B z Vertical focusing Problem: Isochronous cyclotron: B z (r) = (r)b(0) Vertical focusing: Magnetic field versus r Vertical Lorentz force: F z e v B v r rb Not compatible! Solution: Increasing field versus r + additional vertical focusing Vertical defocusing for isochronous cyclotron =0 for field with no dependence on 0 for field with dependence on Additional vertical focusing: Non-cylindrical magnet pole 20

Vertical focusing: Azimuthally varying Field Azimuthally-varying field (AVF): AVF B 0: AVF + spiral pole geometry: Additional vertical focusing Isochronous cyclotron with strong transverse focusing Vertical focusing: IBA medical cyclotron 21

Applications of medical cyclotrons Cyclotron for radionuclide production GE PETtrace 700 RF input Targets for radionuclide production RF cavity RF cavity Spiral sectors RF input 22

Cyclotron-produced PET radionuclides Acceleration of protons or deuterium by a cyclotron Medical cyclotron at PET center in Aarhus IBA Cyclone 18 Twin: Particles: Protons Beam energi:18 MeV (protons) Number of targets: 8 Shielding:1.8 m concrete 23

Positron emission tomography (PET) 511 kev 511 kev Cyclotron-based proton therapy facility Danish Center for Proton Therapy (DCPT): Beam line Energy selection system (ESS) Degrader: Energy adjustment Research room Gantry (100-200 tons) Gantry (100-200 tons) Gantry (100-200 tons) Cyclotron Time line: March 2015: Equipment contract July 2017: Installation of equipment October 2018: First patient 24

Cyclotron: Energy change Courtesy by PSI Apertures Apertures Dipole Energy slit Energy slit: Selection of treatment energy Cyclotron Degrader Dipole Degrader + ESS transmission: Degrader: Beam energy Beam size, divergence, and energy spread Dose deposition in the patient Dose distribution of raw beam: Passive scattering: Pencil beam scanning (PBS): Simple Straight forward treatment of moving organs Excess dose to normal tissue Significant neutron dose Patient-specific collimators and compensators No requirement of patientspecific collimators and compensators Interplay effect for moving organs 25

Gantry Varian gantry in Munich Proton gantry: Weight: 100-200 t Diameter: ~10 m Speed: 360/min Treatment center accuracy: < 1 mm Treatment room Varian ProBeam: Gantry nozzle Imaging system Patient couch 26

Literature Medical Electron Accelerators, C. J. Karzmark, C. S. Numan, and E. Tanabe, McGraw-Hill, 1993. T. Stammbach, Introduction to cyclotrons, CERN Accelerator School: Cyclotrons, linacs and their applications, La Hulpe, Belgium, 28 Apr - 5 May, 1994 (http://cas.web.cern.ch/cas/) P. Heikkinen, Cyclotrons, CERN Accelerator School: 5 th general accelerator physics course, Jyväskylä, Finland, 7-18th September, 1992 (http://cas.web.cern.ch/cas/) http://www.youtube.com/watch?v=jsgnwfbex1a&goback=%2egde_ 885057_member_242088270 27