MT4-024/MT4-230 MT8-024/MT8-230

Similar documents
MT4-024/MT4-230 MT8-024/MT8-230

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

T7560A,B,C Digital Wall Module

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

HERZ-Thermal Actuators

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

HCE80/HCC80/HCE80R/HCC80R

T6580 FAN COIL CONTROLLER

Automatic control equipment for HVAC systems

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

T5000 T000 LCD Digital Fan Coil Thermostat

Electronic Control Devices The European Product Catalogue 2007

evohome Wireless Radiator Zoning Kit Installation & User Guide

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

User Manual THR840DUK Digital Thermostat

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

RF 1. Contents: Connecting diagram. Detailed information:

Data sheet Thermostatic sensors type RA 2000

Adjustable room thermostat for heating only or cooling only systems

Electro-Pneumatic Bus Door Control Mechanism

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Floor Heating Warehouse.co.uk

Actuator for modulating control AME 435

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

ELECTRIC CENTRAL HEATING FLOW BOILER

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Product and Application Description

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

Flush-mounted room thermostats

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

TAC Erie VT/VS PopTop Series Two Position Spring Return Valves

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Industrial infrared heater IR For premises with large volumes and high ceilings

ABB i-bus KNX Fan Coil Controller FC/S 1.1

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

V1810. Alwa-Kombi-4 Circulation throttle valve. Product data

HMI Components. Series. Indicator Pushbutton Illuminated pushbutton. Machinery and Automation Building technology Panel building.

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

RRV934. Multi-controller. Synco living

COMITÉ EUROPÉEN DES ASSURANCES

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Operating Instructions. Room temperature controller

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

Cable Plug acc. to DIN EN , Form A

Heating Controller. Building Technologies HVAC Products

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

Electric Rotary Actuator - On/Off or programmable control actuator

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

DC DC CONVERTER 1000W VDC Input / 12VDC Output

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

V5001S. Kombi-S Shutoff Valve. Product specification sheet

S & P COIL PRODUCTS LTD SPC HOUSE, EVINGTON VALLEY ROAD, LEICESTER. LE5 5LU. Electrical layouts for EC Motors in Fan Convector units

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R.

ACS-30-EU-EMDR-10-MOD

Messko. Messko. MTraB - Maintenance Free Dehydrating Breather Ordering specifications XX - XX - XXX - XX

Inwall Room Temperature Unit

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

RY2 miniature industrial relays

VIESMANN. Installation and service instructions VITOTROL 100. for contractors

8146/5 Series Breaker Panelboards

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Proximity Switches RS (Reed Switch)

Pluggable interface relays CR-P Pcb relays

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

INSTALLATION AND OPERATION MANUAL

T-100-R Installation Guide

Cooling system components, removing and installing

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

Electronic Pressure Switch EDS 300

HVAC Processes. Lecture 7

Transmitter Actuator 230V wave UP 560. Operation

T6861 Series Large LCD Digital Thermostat 110/220 VAC 2-pipe/4-pipe fan coil control

49 Series - Relay interface modules A. Features

HEAVY DUTY STORAGE GAS

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Failure code manual. content

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

Installation Guide for Hive Active Heating

Charge Controller CC611/CC612 Preliminary datasheet

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

SLIM LINE FUME HOOD MONITOR

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

GENERAL PRODUCT OVERVIEW

Transcription:

Smart-T MT4-024/MT4-230 MT8-024/MT8-230 SMLL LINER THERMOELECTRIC CTUTORS PRODUCT DT FETURES No mounting tools required (easily mounted using valve adapter) Water-protected housing design in all mounting positions Pluggable cable for easy installation and servicing uxiliary switch models for driving pumps or fans Low power models Normally-open and normally-closed models Compact design allows installation in limited space Visual indicator showing valve position and type of action (NO or NC) Noiseless operation Reliable long-term operation Overload protection (4 kv) for 230 V models PPLICTION Smart-T small linear actuators are used in room and zone applications for -controlled two-point and pulse-widthmodulated (PWM*) regulation of heating and cooling systems such as fan coil units, radiators, floor heating systems, chilled ceilings, and convectors. Fit on standard M30 x 1.5 heating/cooling valves, thermostatic radiator valves, and valve inserts for manifolds and compact radiators. Special valve adapters on request. *Recommended controllers: Excel 10 and Excel 12 controllers (use with other, non-honeywell controllers may adversely influence PWM-operation). SPECIFICTIONS Max. stroke MT4: 4 mm MT8: 8 mm Power supply MTx-024: 24 Vac/dc ± 20% MTx-230: 230 Vac +10%... -15% Stem force 90 N Opening/closing dependent on ambient temperature (see Table 3) mbient temperature max. 50 C Electrical See Table 3 on page 3. specifications Protection standard IP44 in all mounting positions Cable length 1 m, other cable lengths upon request Cable wires MTx-xxx: 2 x 0.5 mm 2 MTx-xxxS: 4 x 0.35 mm 2 Max. permissible MTx-xxxS: 5 (3) auxiliary switch current Medium temperature max. 120 C U.S. Registered Trademark EN0-0490GE51 R0709 Copyright 2009 Honeywell Inc. ll rights reserved

MT SMLL LINER THERMOELECTRIC CTUTORS ORDERING INFORMTION Table 1. ctuators order number action* additional features voltage stroke MT4-024-NC MT4-024-NO MT4-024-NC-2.5M MT4-024-NO-2.5M MT4-024LC-NC MT4-024LC-NO MT4-024S-NC MT4-024S-NO MT4-230-NC MT4-230-NO MT4-230-NC-2.5M MT4-230-NO-2.5M MT4-230LC-NC MT4-230LC-NO MT4-230S-NC MT4-230S-NO MT8-024-NC MT8-024-NO MT8-024-NC-2.5M MT8-024-NO-2.5M MT8-024LC-NC MT8-024LC-NO MT8-024S-NC MT8-024S-NO MT8-230-NC MT8-230-NO MT8-230-NC-2.5M MT8-230-NO-2.5M MT8-230LC-NC MT8-230LC-NO MT8-230S-NC MT8-230S-NO 24 Vac/dc 230 Vac/dc 24 Vac/dc 230 Vac/dc *Without power, in combination with standard 2-way valve; "" = stem extends, "" = stem retracts 4 mm 8 mm MT-CLIP MT-DPT-HW MT-DPT-HP MT-CLE-1.5M MT-CLE-2.5M MT-CLE-5M MT-CLE-10M EV10R HC1VEL order number Table 2. ccessories mounting clip, 10 units mounting adapter M30 x 1.5, 10 units description mounting adapter for Herz/Polytherm valves, 10 units cable suitable for MT4-024/-230/-024LC/-0230LC and MT8-024/-230/- 024LC/-0230LC, 10 units Danfoss-R adapters, 10 units Mounting adapter for Velta compact manifold EN0-0490GE51 R0709 2

MT SMLL LINER THERMOELECTRIC CTUTORS ELECTRICL SPECIFICTIONS order number initial current* Table 3. Electrical specifications permanent current* power min. run for full nominal valve stroke * 4 mm models 8 mm models MTx-024-xx, MTx-024S-xx ~0.7 < 0.1 < 3 W 4.0 min 6.0 min MTx-024LC-xx ~0.2 < 0.05 < 2 W 6.0 min 7.5 min MTx-230-xx, MTx-230S-xx ~0.6 ** 0.014 3 W 2.5 min 3.5 min MTx-230LC-xx ~0.4 ** 0.010 2 W 3.5 min 5.5 min *ll values at nominal voltage. **verage during first 500 msec. MOUNTING NOTE: Connection leads must not touch piping (heat transfer). Fig. 1. Mounting / installation positions Fig. 2. Dismounting FUNCTION When the operating current is applied, a PTC resistor heats up a wax element. fter a delay, this wax element expands, causing stroke movement. 3 EN0-0490GE51 R0709

MT SMLL LINER THERMOELECTRIC CTUTORS Position Indicator The position indicator (the red indicator behind the window on the face of the actuator) shows the model's type of action (NO or NC) as well as the current stroke position. NC NO Fig. 3. Position indicator WIRING grün, vert, verde, green, zielony grün, vert, verde, green, zielony 230 Vac / 24 V MTx-xxxS 5 (3) braun, brun, marrone, brown, brazowy blau, bleu, blu, blue, niebieski R-T 230 Vac / 24 V Ω 3 W braun, brun, marrone, brown, brazowy blau, bleu, blu, blue, niebieski R-T 230 Vac / 24 V Ω Fig. 4. Wiring diagrams Opening and Closing Time MTx-xxx, MTx-xxxLC 3 W (MTx-xxxLC: 2 W) stroke NO NC power on off dead opening dead closing Fig. 5. Opening and closing NOTE: Opening and closing s depend upon ambient temperature and model. EN0-0490GE51 R0709 4

MT SMLL LINER THERMOELECTRIC CTUTORS Valve ction DIMENSIONS NC (normally-closed) version NO (normally-open) version NC NO NC NO H X L dimension MT4-xxx MT8-xxx W W H L X 59 42 45 6 67 Fig. 7. Dimensions (in mm) Fig. 6. Valve action Normally open: 2-way valve, - open without power; Normally closed: 2-way valve, - shut without power; NOTE: Fig. 6 is a schematic diagram showing typical valve action. ctual function can vary depending upon the individual type of valve. Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z.. La Pièce 16, Switzerland by its uthorized Representative: utomation and Control Solutions Honeywell GmbH öblinger Strasse 17 71101 Schönaich Germany Phone: (49) 7031 63701 Fax: (49) 7031 637493 http://ecc.emea.honeywell.com Subject to change without notice. Printed in Germany EN0-0490GE51 R0709