REV: Liquid Rubber Asbestos Cement Specification

Similar documents
Wecryl Waterproofing System under surfacing supplied by others

Your guide to home maintenance. Flat Roofs

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION

Construction. Pre-Bagged Structural Waterproofing System. Product Description. Product Data. Tests. Form

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

WATERPROOFING FOR CONCRETE STRUCTURES

Seamless Waterproofing. Systems

BLACK JACK ALL WEATHER ROOF COATING

Epdm Flat Roofing Systems

How to repair your existing low slope flat roof.

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Elastic, 1-part-polyurethane, liquid waterproofing membrane

Triflex system: Triflex ProDetail. Solution type: Roof detail and repair waterproofing. Application: Overlay of existing substrate

Third Party Inspection Guidelines For Inspectors As Part of the dryvitcare EIFS Repair/Restoration

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

WATERPROOFING OF WET ROOMS

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER POLYSOCYANURATE SYSTEM DESCRIPTION TORCH SYSTEM OVER POLYISO (15,17,19 YR) TH/BS-TH/CS

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM

SEAMS SEAMING USING SEAM TAPE

THERMOTEK SELF ADHESIVE MEMBRANE +G2 OVER WOOD SYSTEM DESCRIPTION SELF ADHESIVE OVER WOOD (8YR) BS-SA/CS

USER GUIDE Easier, Safer, Betta! WATERPROOFING

bout your HOUSE before you start Repairing And Replacing Materials Exterior Walls

MASONRY RESTORATION Lime Putty Mortar Repointing Guide

K2 STONE NATURAL VENEER

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

HEB 38 BLANCO AND WEST AVENUE FLUID APPLIED EPDM RUBBER ROOF RECOVERY SYSTEM APPLICATION

GigaCrete Specification PlasterMax

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER

Section EXTERIOR STONE VENEER Full Mortar

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES

BITUMINOUS ROOF COATINGS, CEMENTS, PRIMERS AND ADHESIVES

METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES

High Performance Solutions and Compounds for Roofing and Structural Waterproofing

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Colorado State University. Durrell Center Roof Repair

SIKA BRIDGE DECK WATERPROOFING SYSTEM SIKALASTIC -851 BRIDGE DECK WATERPROOFING SYSTEM

Chapter. Restoration of Damaged Structures

RIW SHEETSEAL 226 BENEFITS APPLICATIONS APPLIED TO. CI/SfB TN6 L6813. November l Water and water vapour barrier. l Factory controlled thickness

INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS

The existing roof angle change terminations and flashings when sound and intact can be reused.

Rooflight INSTALLATION INSTRUCTIONS

Ubiflex. Non-lead flashing system

Baumit Renders for Porotherm Masonry. Application Guidelines. n Light and easy application n Tried and tested

Resurfacing Concrete. Page 1 of 5

Mineral waterproof coating PCI Dichtschlämme

Site Inspection Report

BDA Agrément BAR /02/A

SECTION FLUID APPLIED ROOFING (LIGHT TRAFFIC DECKS OVER CONCRETE)

Commercial Roof Management

Bituminous Sheet Flat Roofs: Their repair and maintenance

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

Solvent Cementing Instructions For Plastic Pipe & Fittings

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

T R A N S F E R A B L E F U L LY

LAYING BLOCK AND BRICK

DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.

ITEM THERMOPLASTIC MEMBRANE ROOFING

Construction. Sikalastic -560 Economical and eco-friendly liquid applied roof waterproofing solution. Product Description.

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

The Minnesota Lath and Plaster Bureau Repairing Cracks in Stucco

SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING General Materials Equipment...

Backstop NT. Backstop NT Specifications DS180. A High Performance, Polymer-Based, Noncementitious Water-Resistive Membrane and Air Barrier

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

Avoiding Air Barrier Pitfalls

12.1 Schlüter -KERDI-BOARD

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

ROOF FLASHING SPRINGLOK FLASHING SYSTEM FEATURES & BENEFITS PRODUCT DESCRIPTION

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

Maintenance & repair Solutions

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

GUIDE SPECIFICATION COMBINATION SURFACE SYSTEM FOR NEW HOT MIX ASPHALT TENNIS COURTS I. PART 1 - GENERAL

Building Owners Guide to a Duro-Last System!

High Performance Building Materials SCREEDS REPAIR MORTARS LEVELLING & SMOOTHING WATERPROOFING TILE ADHESIVES & GROUTS PRIMERS & ADDITIVES

DENSO WATERPROOFING SYSTEMS

USER GUIDE Easier, Safer, Betta! gripsetbetta.com WATERPROOFING

BENTLEY ELEMENTS COLLECTION LVT

Peel & Seal Self-Stick Roofing Solutions

dryvitcare EIFS Repair Procedures

Shower Walls and Tub Surrounds

TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09

CLEANING ASBESTOS ROOFING? REMOVE THE THREAT OF DANGEROUS ASBESTOS FIBRES ENCAPSULATE WITH

Concrete Resurfacing. System Guide. by Parchem Construction Supplies

How to build a Pizza Oven in 4 days

Division 9. SignaFlor Pad and Pour Flooring System

Installation System. Existing Resilient Sheet Floors

NEOGARD. Preventive Maintenance Manual

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

Acrylic Coatings: The Perfect Stucco Finish

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

Concrete Waterproofing Systems

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

Manufactured Stone and Thin Brick Installation Systems

Transcription:

REV:2 14.06.13 Liquid Rubber

Preparation: Prior to application of the system the substrate must be suitably prepared: Option 1. A specialist surface preparation company can be employed to remove heavy build-up of moss and other friable materials utilising HSE approved systems. (For more information on asbestos cleaning contact our technical desk) Option 2. When the roof is reasonably clean (little moss build-up or other growth) it is possible to treat the roof using bio-cide and Liquid Rubber Flood Coat to give a well balanced/stable surface. (For more information on asbestos cleaning contact our technical desk) Liquid Rubber Flood Coat if required, flood coat can be applied by brush, roller or airless spray at an application rate of approx. 4-5 sq/m per litre. and should be applied to all surfaces requiring waterproofing. Liquid Rubber System Substrate Cleaned surface ready to accept flood coat. Flood Coat Flood coat is used to seal in the porous surface if required. Liquid Rubber Membrane The main waterproofing membrane applied in 2 x 1mm coatings. Upstands to existing services, flashings, parapets etc. should be covered with High Build and GeoTextile reinforcing membrane. Existing fixings brush apply Liquid Rubber Trowel Grade around the heads and washers of all exposed fixings Existing repairs loose or unstable repairs to be removed and new repairs carried out using GeoTextile reinforcing membrane bedded into Liquid Rubber High Build. Detailing Joints Substrate Cleaned surface pre coated in flood coat. Liquid Rubber Membrane Generous coating of High Build applied to surface. Trowel Grade is used to fill any gaps Geo Textile Geo Textile embedded into High Build and brushed flat.

Preparation: Applying LRS High Build and GeoTextile reinforcement to upstands. etc Apply a liberal first coat of High Build to the areas concerned. Pre-cut the Geo Textile reinforcing tape to size and bed into the High Build, shiny side up. Using a clean brush smooth the geotextile out forcing High Build through the GeoTextile. Apply extra High Build as required to fully coat the GeoTextile, spread any surplus High Build onto the next upstands to be coated. Try to avoid creating creases or blisters in the GeoTextile. Where the membrane is required to be dressed into a mortar course it should be raked out and re-pointed with Liquid Rubber Trowel Grade. When applying the Liquid Rubber onto brickwork without dressing into the mortar course the membrane should be finished in the middle of the brick course. When applying to services, vents etc. the GeoTextile reinforcing membrane should be pre-cut to closely follow the profile of the upstand. The reinforcing membrane should be fully bedded into the High Build, care should be taken to avoid any bridging or creases in the membrane. Cracks in existing roof sheets Liquid Rubber High Build should be applied by brush along the full length of the crack. GeoTextile reinforcing membrane should then bedded into the High Build while the solution is still wet. A second coat of High Build must be applied after the first coat has dried. Detailing Angles Substrate/Wall Cleaned surface pre coated in flood coat. Liquid Rubber Membrane Generous coating of High Build applied to surface. Geo Textile Geo Textile embedded into Liquid Rubber and brushed flat. Please ensure that when applying Geo Textile that it is completely flat and free of gaps or fish mouths. The perfect finish for Geo Textile leaves it flat to the surface and free of gaps fully embedded into the High Build below.

Preparation: End Laps. Only If deemed necessary a single coat of High Build can be brush applied across the end laps to roof sheets, large gaps should be filled with Liquid Rubber Trowel Grade. Similarly any damaged corners or exposed mitres should be filled with Liquid Rubber Trowel Grade. Side Laps Liquid Rubber High Build with GEO Textile reinforcing membrane should be applied as previously described to any suspect side laps in the fibrous cement sheets and roof lights. Bolt Heads/Fixings Care should be taken to ensure all bolt heads and fixings and the surrounding surface extending 15mm are coated with a combination of Liquid Rubber Trowel Grade and Liquid Rubber High Build. It is the responsibility of the contractor to choose the appropriate materials to be used depending on the precise nature of the fixings, what is essential is that the finished coating is not penetrated by any of the bolt heads or fixings. End/Edge Laps Substrate Cleaned Asbestos sheet. Edge Lap Cleaned edge lap free of dirt and debris. Liquid Rubber High Build Generous coating of High Build overlapping joints by 100mm. Use Geo Textile if required. Bolt Head/Fixing exposed bolt head Liquid Rubber High Build applied to the exposed bolt head and the surrounding area.

Detailing Please leave between 1-2 hours for detailing to be fully cured before application of main membrane. Coverage Rate When using Liquid Rubber High Build an application rate of 1ltr per sq/m per coat is to be maintained. This can be achieved by measuring the area to be covered and by weighing or decanting the necessary volume, 1Kg = 1Ltr. Surface Area When calculating areas be sure to include the surface area to avoid a shortfall in product. Liquid Rubber Approved Contractor Training LRS host regular training programmes to provide contractors with the necessary skills and product knowledge to become a fully certified Liquid Rubber Approved Contractor. For more information please call our technical help desk or email one of our team. Application: Liquid Rubber High Build is a two coat system applied by brush, roller or airless spray. The contractor is to determine the most suitable method of application. L.R. High Build should be applied at an average rate of 1.0Lt per sq/m per coat. Allow the first coat to dry before applying the second coat. Use area to volume calculations to ensure the correct coverage. Plan your application method working towards your exit point. Liquid Rubber Instant Set Spray Grade is a specialist single coat application normally used on larger contracts and can be applied at a rate of approx. 800 sq/m per day. Instant Set Spray Grade has to be applied by an approved/ trained spray team using bespoke spray equipment. Please consult our specific manual for coverage, methodology, advice and training. Arrangements can be made to hire a spray machine to apply the main membrane with all preparation work being carried out by the contractor. Contact our technical help desk for further information.

Limitations Liquid Rubber should not be applied when the ambient temperature is below 5 o c. The uncured membrane may be damaged if frozen. Do not apply to wet or frozen surfaces or directly prior to rain. Caution Avoid storage below 5 O c, keep out of direct sunlight. Please consult data sheets before using Liquid Rubber. Additional Information: Liquid Rubber Top Coat (Optional). Liquid rubber is UV resistant and is not significantly affected by solar gain. Grey Top Coat can be applied to the Liquid Rubber membrane to provide a solar reflective finish. Liquid Rubber Top Coat should be applied at a coverage rate of 5 sq/m per Litre. Handling Keep containers upright and tightly closed when not in use and keep from freezing. Maintenance In accordance with good roofing practice it is the clients responsibility to ensure that the roof is regularly inspected and maintained to ensure the membrane is at its optimum performance. This includes removal of foreign materials and dirt and the repair of any damage by tradesmen, falling debris etc. For further information please consult our separate data sheet for maintenance and repair of Liquid Rubber membranes.