Triflex system: Triflex ProDetail. Solution type: Roof detail and repair waterproofing. Application: Overlay of existing substrate
|
|
- Randall Higgins
- 8 years ago
- Views:
Transcription
1 CAD details Triflex ProDetail Triflex system: Triflex ProDetail Solution type: Roof detail and repair waterproofing Application: Overlay of existing substrate CAD details CAD S:
2 CAD details Triflex ProDetail Contents Detail waterproofing >>> Detail waterproofing termination to chase >>> Upstand >>> Upstand with chase >>> Upstand with flashing / chase >>> Upstand with mechanically fixed flashing Variant A >>> Upstand with mechanically fixed flashing Variant B >>> Upstand to raised cill >>> Upstand to coping >>> Upstand with coping encapsulated >>> Upstand to coping waterproofing beneath coping >>> Upstand to secret fixed capping >>> Upstand with secret fixed capping encapsulated >>> Upstand to secret fixed capping waterproofing beneath capping >>> Upstand to rooflight >>> Upstand to access hatch >>> Upstand to pitched adjacent roof >>> Penetration >>> Surface mounted detail >>> High temperature (>90 C) flue pipe / penetration >>> Flush outlet >>> Outlet with leaf / debris guard >>> Drainage channel / gutter >>> Mechanically fixed edge trim with drip >>> Insitu kerb with mechanically fixed edge trim with drip >>> Plinth >>> Plinth with free standing load >>> Plinth with surface mounted detail >>> Loop expansion joint >>> Overbanding crack / day joint greater than mm >>> Change in level >>> System build-up Build-up element Consumption 2 Primer - if required (refer to specification) (i) Triflex Cryl Primer 222 / Kg/m² min. (ii) Triflex Primer L/m² min. (iii) Triflex Metal Primer L/m² (iv) Other specialist primers are available 2 Reinforced waterproofing membrane (single process) Triflex ProDetail 2.00Kg/m² min. (below reinforcement) Triflex 0g Reinforcement Fleece.05m²/m² min. Triflex ProDetail.00Kg/m² min. (above reinforcement) Triflex (UK) Ltd Whitebridge Way Stone Staffordshire ST5 8JS Tel: info@triflex.co.uk 07/205
3 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE WATERPROOFING PRO_00_ WATERPROOFING 28/07/205 ST5 8JS Tel:
4 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE SEAL CHASE USING TRIFLEX CRYL PASTE WATERPROOFING TERMINATION TO CHASE PRO_002_ WATERPROOFING TERMINATION TO CHASE 28/07/205 ST5 8JS Tel:
5 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE 50mm MIN. UPSTAND PRO_005_UPSTAND 00mm MIN. 30/07/205 ST5 8JS Tel:
6 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE SEAL CHASE USING PROPRIETARY SOLVENT FREE MASTIC OR TRIFLEX CRYL PASTE 50mm MIN. UPSTAND WITH CHASE PRO_006_UPSTAND WITH CHASE 00mm MIN. 30/07/205 ST5 8JS Tel:
7 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE 2 2 PROPRIETARY FLASHING SEAL CHASE USING PROPRIETARY SOLVENT FREE MASTIC OR TRIFLEX CRYL PASTE 50mm MIN. UPSTAND WITH FLASHING / CHASE PRO_007_UPSTAND WITH FLASHING_CHASE 00mm MIN. 30/07/205 ST5 8JS Tel:
8 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE 2 2 PROPRIETARY FLASHING MECHANICALLY FIXED SEAL INTERFACE USING PROPRIETARY SOLVENT FREE MASTIC 50mm MIN. UPSTAND WITH MECHANICALLY FIXED FLASHING - VARIANT A PRO_008_UPSTAND WITH MECHANICALLY FIXED FLASHING_VARIANT A 00mm MIN. 30/07/205 ST5 8JS Tel:
9 WATERPROOFING 50mm MIN. TRIFLEX 0g REINFORCEMENT FLEECE PROPRIETARY FLASHING MECHANICALLY FIXED 50mm MIN. UPSTAND WITH MECHANICALLY FIXED FLASHING - VARIANT B PRO_009_UPSTAND WITH MECHANICALLY FIXED FLASHING_VARIANT B 00mm MIN. 30/07/205 ST5 8JS Tel:
10 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE SEAL USING PROPRIETARY SOLVENT FREE MASTIC UPSTAND TO RAISED CILL 50mm MIN. PRO_00_UPSTAND TO RAISED CILL 00mm MIN. 30/07/205 ST5 8JS Tel:
11 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE SEAL USING PROPRIETARY SOLVENT FREE MASTIC 50mm MIN. UPSTAND TO COPING PRO_0_UPSTAND TO COPING 00mm MIN. 30/07/205 ST5 8JS Tel:
12 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE TRIFLEX CRYL PASTE 50mm MIN. UPSTAND WITH COPING ENCAPSULATED PRO_02_UPSTAND WITH COPING ENCAPSULATED 00mm MIN. 30/07/205 ST5 8JS Tel:
13 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE Kg/m² MIN. WITH TRIFLEX QUARTZ ( Kg/m² APPROX. TO CREATE AN IMPACT RESISTANT. ALLOW TO CURE AND REMOVE EXCESS QUARTZ. COPING BEDDED ON QUARTZ FILLED LAYER WITH SUITABLE MORTAR 2 50mm MIN. UPSTAND TO COPING WATERPROOFING BENEATH COPING PRO_03_UPSTAND TO COPING WATERPROOFING BENEATH COPING 00mm MIN. 30/07/205 ST5 8JS Tel:
14 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE 50mm MIN. UPSTAND TO SECRET FIXED CAPPING PRO_04_UPSTAND TO SECRET FIXED CAPPING 00mm MIN. 30/07/205 ST5 8JS Tel:
15 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE TRIFLEX CRYL PASTE 50mm MIN. UPSTAND WITH SECRET FIXED CAPPING ENCAPSULATED PRO_05_UPSTAND WITH SECRET FIXED CAPPING ENCAPSULATED 00mm MIN. 30/07/205 ST5 8JS Tel:
16 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE 2 50mm MIN. 50mm MIN. CAPPING INSTALLED / REINSTATED AFTER WATERPROOFING APPLICATION 2 TRIFLEX 3.00 Kg/m² MIN. TO ENCAPSULATE FIXING HEADS 50mm MIN. UPSTAND TO SECRET FIXED CAPPING WATERPROOFING BENEATH CAPPING PRO_06_UPSTAND TO SECRET FIXED CAPPING WATERPROOFING BENEATH CAPPING 00mm MIN. 30/07/205 ST5 8JS Tel:
17 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE ROOFLIGHT SEAL USING PROPRIETARY SOLVENT FREE MASTIC 50mm MIN. UPSTAND TO ROOFLIGHT PRO_07_UPSTAND TO ROOFLIGHT 00mm MIN. 30/07/205 ST5 8JS Tel:
18 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE SEAL USING PROPRIETARY SOLVENT FREE MASTIC UPSTAND TO ACCESS HATCH 50mm MIN. PRO_08_UPSTAND TO ACCESS HATCH 00mm MIN. 30/07/205 ST5 8JS Tel:
19 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE TO SPECIFICATION) EXTERIOR GRADE PLYWOOD OR SIMILAR COMPATIBLE WATER RESISTANT BOARD TRIFLEX CRYL PASTE 2 COUNTERSUNK FIXING 3 EXISTING FELT OR MEMBRANE 4 EXTERIOR GRADE PLYWOOD OR SIMILAR COMPATIBLE WATER RESISTANT BOARD, MECHANICALLY FIXED TO RAFTERS TO PROVIDE A STABLE / SOUND SUBSTRATE FOR 50mm MIN. UPSTAND TO ADJACENT PITCHED ROOF 4 3 PRO_09_UPSTAND TO PITCHED ADJACENT ROOF 00mm MIN. 2 30/07/205 ST5 8JS Tel:
20 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE PENETRATION 50mm MIN. PRO_055_ PENETRATION 00mm MIN. 00mm MIN. 03/08/205 ST5 8JS Tel:
21 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE STAR CUT REINFORCEMENT FLEECE AROUND BOLT HEADS AND MAKE GOOD WITH TRIFLEX CRYL PASTE 2 TRIFLEX 3.00 Kg/m² MIN. TO ENCAPSULATE FIXING HEADS 50mm MIN. SURFACE MOUNTED 50mm MIN. 2 PRO_056_SURFACE MOUNTED 00mm MIN. 30/07/205 ST5 8JS Tel:
22 AREA WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE 50mm MIN. 2 METAL SLEEVE TRIM MECHANICALLY FIXED TO SUBSTRATE ALLOWING FOR VENTED AIR GAP OR HEAT RESISTANT INSULATION ADJACENT TO FLUE / PIPE METAL APRON FLASHING MECHANICALLY FIXED TO FLUE / PIPE ALLOWING FOR VENTED AIR GAP 50mm MIN. 2 50mm MIN. HIGH TEMPERATURE (GREATER THAN 90 C) FLUE PIPE / PENETRATION 00mm MIN. PRO_057_HIGH TEMPERATURE_GREATER THAN 90_C_FLUE PIPE_ PENETRATION 03/08/205 ST5 8JS Tel:
23 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE OUTLET LINER / SPIGOT (PREPARED) GENERIC SUBSTRATE LIFT OUTLET COVER / GUARD TO ALLOW FOR PREPARATION, PRIMING AND WATERPROOFING INSTALLATION AND REINSTATE FLUSH OUTLET 00mm MIN. PRO_0_FLUSH OUTLET 50mm MIN. 30/07/205 ST5 8JS Tel:
24 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE OUTLET LINER / SPIGOT (PREPARED) GENERIC SUBSTRATE LIFT OUTLET COVER / GUARD TO ALLOW FOR PREPARATION, PRIMING AND WATERPROOFING INSTALLATION AND REINSTATE OUTLET WITH LEAF / DEBRIS GUARD 00mm MIN. PRO_02_OUTLET WITH LEAF_DEBRIS GUARD 50mm MIN. 30/07/205 ST5 8JS Tel:
25 MAIN AREA WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE MAIN AREA WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE DEPENDING UPON THE SIZE / PROFILE OF THE DRAINAGE CHANNEL / GUTTER, APPLY THE REINFORCED MEMBRANE IN TRANSVERSE STRIPS ACROSS THE WIDTH OF THE DRAINAGE CHANNEL / GUTTER, OR COMPLETE THE ING TO THE SIDES, LAPPING ONTO THE UPPER LEVEL AND SOLE / BASE, ALLOW TO CURE AND THEN APPLY A SEPARATE REINFORCED STRIP TO THE SOLE / BASE 00mm MIN. DRAINAGE CHANNEL / GUTTER PRO_5_DRAINAGE CHANNEL_GUTTER 06/08/205 50mm MIN. 00mm IF LEFT > 2 HOURS ST5 8JS Tel:
26 AREA WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE SUPPORT BATTEN MECHANICALLY FIXED MECHANICALLY FIXED EDGE TRIM WITH DRIP 00mm MIN. PRO_20_ MECHANICALLY FIXED EDGE TRIM WITH DRIP 03/08/205 ST5 8JS Tel:
27 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE PROPRIETARY MECHANICALLY FIXED EDGE TRIM SUPPORT BATTEN MECHANICALLY FIXED INSITU KERB WITH MECHANICALLY FIXED EDGE TRIM WITH DRIP 00mm MIN. PRO_202_INSITU KERB WITH MECHANICALLY FIXED EDGE TRIM WITH DRIP 30/07/205 ST5 8JS Tel:
28 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE 50mm MIN. 00mm IF LEFT > 2 HOURS PLINTH PRO_25_PLINTH 00mm MIN. 30/07/205 ST5 8JS Tel:
29 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE RUBBER CRUMB PROTECTION MAT 50mm MIN. 00mm IF LEFT > 2 HOURS 0mm MIN. PLINTH WITH FREE STANDING LOAD PRO_252_PLINTH WITH FREE STANDING LOAD 00mm MIN. 30/07/205 ST5 8JS Tel:
30 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE STAR CUT REINFORCEMENT FLEECE AROUND BOLT HEADS AND MAKE GOOD WITH TRIFLEX CRYL PASTE 2 TRIFLEX 3.00 Kg/m² MIN. TO ENCAPSULATE FIXING HEADS 2 50mm MIN. 50mm MIN. 50mm MIN. OR TO EXTENT PLINTH WITH SURFACE MOUNTED PRO_253_PLINTH WITH SURFACE MOUNTED 00mm MIN. 30/07/205 ST5 8JS Tel:
31 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE GENERAL NOTES WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE TRIFLEX FLEXFILLER LOOP EXPANSION JOINT 2 CLOSED CELL POLYETHYLENE FOAM FILLER ROD 3 TRIFLEX EXPANSION JOINT LINER BEDDED IN TRIFLEX CRYL PASTE 00mm MIN. 00mm MIN. 50mm MIN. 5mm MAX. 2 3 PRO_30_LOOP EXPANSION JOINT 35mm MIN. 30/07/205 35mm MIN. ST5 8JS Tel:
32 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE GENERAL NOTES AREA WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE TRIFLEX CRYL PASTE OR TRIFLEX FLEXFILLER OVERBANDING CRACK / DAY JOINT GREATER THAN mm 2 OVERBAND TO EXTEND A MINIMUM 75mm EITHER SIDE OF CRACK / DAY JOINT 2 75mm MIN. 75mm MIN. 75mm MIN. 75mm MIN. PRO_32_ OVERBANDING CRACK_DAY JOINT GREATER THAN mm 03/08/205 ST5 8JS Tel:
33 WATERPROOFING TRIFLEX 0g REINFORCEMENT FLEECE 00mm MIN. ENSURE NOSING IS RIGID / DIMENSIONALLY STABLE CHANGE IN LEVEL PRO_35_CHANGE IN LEVEL 00mm MIN. 30/07/205 ST5 8JS Tel:
!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035
Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí
More informationThe formation of roof waterproofing details calls for
3.5 BUILT-UP ROOFING DETAIL DESIGN INTRODUCTION The formation of roof details calls for a combination of the skills of the designer and the roofer. There are many different approaches to detail design
More informationMemtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems
Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology Modern Efficient Performance Cost Effective Flat Roofing Systems Introduction A complete range of Memtec Roofing and Waterproofing Single
More informationUbiflex. Non-lead flashing system
Ubiflex Non-lead flashing system Ubiflex non-lead flashing Ubiflex is a non-lead waterproof flashing material which can be used in most applications where lead is traditionally used to provide a weatherproof
More informationSite Inspection Report
Site Inspection Report Project Title: 1 Canada Square Location: 1 Canada Square, Canary Wharf, London Date of Inspection: 16/05/12 System / Products: TBA (suggested flame free application) Attendees: G
More informationCHESTERFLEX ROOF WATERPROOFING MEMBRANES
CI/SfB (47) Ln2 Chesterfelt Ltd CHESTERFLEX ROOF WATERPROOFING MEMBRANES Certificate No 94/3062 DETAIL SHEET 2 Product THIS DETAIL SHEET RELATES TO CHESTERFLEX ROOF WATERPROOFING MEMBRANES, POLYESTER REINFORCED
More informationwww.pitchmasticpmb.com PmB Expansion Joints World leaders in expansion joint technology
www.pitchmasticpmb.com Expansion Joints World leaders in expansion joint technology High performance expansion joint solutions Pitchmastic offers a comprehensive range of specialist services to the civil
More informationRooflight INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Rooflight These instructions should be used for: Installing Permanent Trickle Ventilation: Constructing & Waterproofing a Timber Upstand Curb: Installing & Waterproofing Proprietary
More informationEpdm Flat Roofing Systems
Epdm Flat Roofing Systems EDPM can be fully bonded, loose laid and ballasted or mechanically attached depending on the existing roof and its proposed usage. This applies to roofs to be refurbished and
More informationBituminous Sheet Flat Roofs: Their repair and maintenance
Bituminous Sheet Flat Roofs: Their repair and maintenance Flat roof covered in sheets of bituminous felt Introduction Whilst flat roofs are often regarded as inferior to their pitched counterparts and
More informationRead and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS
AC TOPSEAL SELF-ADHERED, GRANULAR SURFACED, SINGLE PLY, LOW SLOPE ROLLED ROOFING 3 X 33.3 = 100 SQ. FT. 10 YEAR MATERIAL LIMITED WARRANTY For Use on Porches / Sheds / Utility Buildings / Accessory Buildings
More informationHow To Repair A Boat Landing Deck With A Boat Bed
RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS Table of Contents Slab-on-grade-to Above Grade Wall...1 Foundation Wall at Footing
More informationINSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
More informationINTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.
INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS Multi-Layer Technology provides increased strength. Specifically designed for interior applications. Compatible with most internal
More informationEDW + FS, VS, VSE, GGL, GGU, GHL. EDW Deck Mounted Skylight and Roof Window Flashing Installation Instructions VAS 452259-0509
EDW + FS, VS, VSE, GGL, GGU, GHL EDW Deck Mounted Skylight and Roof Window Flashing Installation Instructions VAS 4559-0509 a FS, VS, VSE For proper installation, remove cladding as shown b GGL, GGU, GHL
More informationWATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced
More informationLinea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1
Top plate Stud Soffit lining 45mm min nog Fix scotia bead Building underlay/james Hardie rigid air barrier Soffit Detail Building underlay/james Hardie rigid air barrier Bottom plate 25mm wide cant strip.
More informationSystem 5000 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY
CI/SfB Oct 12 (47) Ln Uniclass L524 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY Bailey Flame-free felt roofing Bailey
More informationAsphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
More informationCERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
More informationWATERPROOFING FOR CONCRETE STRUCTURES
MANUAL OF CONTRACT DOCUMENTS FOR ROAD WORKS VOLUME 1 SPECIFICATION FOR ROAD WORKS SERIES 2000 WATERPROOFING FOR CONCRETE STRUCTURES Contents Clause Title Page 2001 General 2 2002 Protection of Bridge Deck
More informationEXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES
Building and Construction Industry A joint industry initiative produced by BSA Supershow logo.indd 1 30/01/2008 9:43:29 AM EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES FAILING WATERPROOFING
More informationTARRANT COUNTY DETAIL STANDARDS
TARRANT COUNTY DETAIL STANDARDS 1. Standard Coping 2. Coping at End Wall 3. Standard Sheet Metal Engagement Details 4. Gravel Guard 5. Gravel Guard Wall Termination 6. Gravel Guard, Gutter, and Downspout
More informationIncluding. Rubershield-Pro. Breather Membrane
Including RubershieldPro Breather Membrane 2 Ruberoid produces a wide range of underslating membranes, primarily to be installed below tiles, slates or metal roofing providing a secondary barrier against
More informationFOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING insulation installed on foundation walls must be separated from the building interior with a code approved thermal barrier. Foam
More informationWindow Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
More informationCITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the
More informationIssue of the Guidelines on Prevention of Water Seepage in New Buildings
graphic: Buildings Department Your REF 來 函 檔 號 :. OUR REF 本 處 檔 號 :.BD GR/1-55/173 FAX 圖 文 傳 真 :..28400451 TEL 電 話 :..2626 1717 www.info.gov.hk/bd To : All Authorized Persons 7 March 2005 Registered Structural
More informationCast iron swing grate in cast iron frame. 300x300 ID concrete chamber. Available chamber depths 400mm or 600mm deep. K&C Roadway SITE PLAN
Cast iron swing grate in cast iron frame Nominal 90 mm inlet SECTION x ID concrete chamber. vailable chamber depths 400mm or 600mm deep CHMBER PLN Stormwater pipe House Chamber location in vehicle cutdown
More informationSikaProof A Technology
SikaProof A Technology The fully bonded waterproofing system Keep your basements durably and securely watertight What is SikaProof A? How does it work? Where can it be used? What are the advantages of
More informationInstallation Guide the Conservation Rooflight
Installation Guide the Conservation Rooflight > a roof window range suitable for pitched roofs between 17.5o and 65o > details for use with flashing kit January 2014 Version: CR_001INST Rev B 1 SECTION
More informationAir-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association
Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-
More informationTITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09
TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09 PMT GUIDE # 10 Book of Order Section G-10.0102o: "The session is responsible for the mission and government of the particular church. It
More informationWhen considering Roof drainage design the following should be taken into account:
Roof Drainage Design The primary objective of a gutter or spouting system is to remove water from the roof catchment area and channel that water to the ground drainage. Water ingress can have detrimental
More informationTFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING
6.CW.1A TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS wood or gas standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING The Fireplace Ltd is able to design and fabricate custom brick open masonry
More informationBUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.
Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS. Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance
More informationAdditions and Alterations
Additions and Alterations Addition and alteration construction is a miscellaneous grouping of home improvement and renovation projects that are generally geared toward the enhancement of an existing principal
More informationSeptember 3, 2009. Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901
September 3, 2009 Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901 RE: Ketchikan Gateway Borough Gateway Recreation Center Roof Observations and Intrusive Inspections
More informationRecord of Work Experiences Trade Qualifier or Pre-Apprenticeship Credits ROOFER
Department of Advanced Education and Skills Apprenticeship and Trades Certification Division Record of Work Experiences Trade Qualifier or Pre-Apprenticeship Credits ROOFER Note to Apprenticeship Applicants
More information1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.
SECTION 075416 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system. 1.2 PERFORMANCE REQUIREMENTS A. Solar Reflectance
More informationGREEN ROOF SYSTEMS ADVANCED LIQUID ROOFING SYSTEMS GREEN ROOF INFORMATION AND DESIGN GUIDE GREEN ROOF SYSTEMS
Sfb () Ln 0/ ADVANCED LIQUID ROOFING SYSTEMS GREEN ROOF INFORMATION AND DESIGN GUIDE ADVANCED SEAMLESS ROOFING SYSTEMS CONTENTS INTRODUCTION TO GREEN ROOFS TYPES OF GREEN ROOF POLYROOF SYSTEMS & SERVICES
More informationSheet A-1 KEY SHEET A-1. Football Roof Plan SHEET A-2 SHEET A-3 SHEET A-4. LaCross Roof Plan. Soccor 2 Roof Plan 88' 45' 87' 46' 45' 45' 10' 3' 25'
Sheet A-1 SHEET A-1 Football Roof Plan 5 LaCross Roof Plan 5 88' 87' SHEET A- 1 DRIP EDGE WITH STANDING SEAM PANEL 2 RAKEWALL SHEET A- RIDGE HIP HEAD WALL 11700 Pierson Rd. Wellington, FL. 1 Soccor 2 Roof
More informationCommercial Roof Inspection Form
Inspection Date: Inspector: Building Information Building ID: No.: Used For: Year Roof Applied: Building Description: Permanent Temporary Building Type: Retail Industrial Residential Building Name: Building
More informationCURRENT PRACTICE SHEET
CURRENT PRACTICE SHEET INTRODUCTION An expansion joint can be defined as a device to support the surfacing, or to provide a running surface, across the expansion gap, ie the area between adjacent spans
More informationRoofers Guide to Underslating Membranes
Roofers Guide to Underslating Membranes IKO is a worldwide enterprise, with more than 3000 employees, and manufacturing plants in Canada, the United States, United Kingdom, Belgium, Holland, France and
More informationBLACK JACK ALL WEATHER ROOF COATING
PAGE: 1 of 6 PRINT DATE: 16/09/2004 BLACK JACK ALL WEATHER ROOF COATING DESCRIPTION BLACK JACK ALL WEATHER ROOF COATING is a solvent based, full bodied black brushable compound with added fibres for reinforcement.
More informationThe better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs
The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................
More informationWecryl Waterproofing System under surfacing supplied by others
Brief description The Wecryl waterproofing system allows a high-quality, seamless and crack-bridging waterproofing layer to be installed under loose-laid or bonded surfacing supplied by others (stone slabs,
More informationSECTION 07530 SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.
SECTION 07530 PART 1 - GENERAL 1.01 DESCRIPTION A. This Section includes the flowing: 1. Removal of existing roofing membrane. Existing bur roof has one overlay and penetration mastic is asbestos containing.
More informationSmooth cap sheet - 0-10 SQ $ 139.00. Smooth cap sheet - 11-50 SQ $ 63.00. Smooth cap sheet - 51-100 SQ $ 36.00 Smooth cap sheet - 101-200 SQ $ 36.
Demolition/Removal of Work 4-ply built up roofing to the insulation (smooth cap sheet) Smooth cap sheet - 0-10 SQ $ 63.00 Smooth cap sheet - 11-50 SQ $ 63.00 Smooth cap sheet - 51-100 SQ $ 35.00 Smooth
More informationCHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
More informationPeel & Seal Self-Stick Roofing Solutions
Peel & Seal Self-Stick Roofing Solutions Ideal for Low Slope Applications Waterproof and Weatherproof Energy Efficient Tough and Durable Versatile, Effective Sealing Around Protrusions Perfect for Vents,
More informationVM ZINC : standing seam Guidelines for specification and installation
VM ZINC : standing seam Guidelines for specification and installation Junglim Architecture - QUARTZ-ZINC Roofing and cladding system in VM ZINC Roofs from a 3 pitch and facades Freedom with shape and appearance
More informationNEW ELECTRICAL SUBSTATION Building 300 SECTION 07 53 23 ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK
ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within
More informationTR21. I n s u l a t i o n. Low Energy Low Carbon Buildings
I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Fourth Issue March 2011 TR21 INSULATION FOR FLAT ROOFS WATERPROOFED WITH PARTIALLY BONDED BUILT UP FELT AND MASTIC ASPHALT High performance rigid thermoset insulation
More informationChimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko
INSTALLATION MANUAL Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko Ventilated Notified entity Building Technical and Research Institute Prague notification no. 1020 This instruction refers to double-layer
More informationUB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
More informationMulti-layer Insulation Blanket for Roofs
Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof
More informationNCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
More informationSECTION 07320 ROOFING TILE
SECTION 07320 ROOFING TILE PART 1 - GENERAL 1.1 SUMMARY: A. Section Includes: 1. Vitrified clay roofing tiles. 2. Tile accessories. 3. Felt underlayment. 4. Self-adhering sheet underlayment. 5. Snow guards.
More informationTHIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150
THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150 SECTION ONE A. Objective The objective of this guide is to provide Owners and General Contractors/Construction
More informationPREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS
Application Instructions for THESE ARE THE MANUFACTURER S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
More informationWATERPROOFING OF WET ROOMS
WATERPROOFING OF WET ROOMS Waterproofing under tiles For longterm enjoyment of a wetroom area a complete and resistant waterproofing system is an important precondition. Most tiles are by themselves waterproof
More informationLeaky Homes Financial Assistance Package (FAP) Repair plan example
LEAKY HOMES FINANCIAL ASSISTANCE PACKAGE FACT SHEET Repair Plan Example - June 2014 Page 1 Leaky Homes Financial Assistance Package (FAP) Repair plan example Introduction This repair plan example is intended
More informationSEAMS SEAMING USING SEAM TAPE
SEAMING USING SEAM TAPE SEAMS The membrane should be positioned so that the width of the seam is 3. Remove excess chalk from a chalk line by snapping the line into the air and then chalk a line one-quarter
More informationRESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
More informationapplication instructions
application instructions ARCHITECTURAL COLLECTION PRIMED BOLD PROFILE 120 SERIES LAP SIDING (D5, T4, D8, T5, Q4) General At the time of manufacture, siding meets or exceeds the performance standards set
More informationFireSmart IRS Insulating Roof Screed
Insulating Roof Screed CI/SfB January 2004 CI/SfB January 2004 M2 P M2 P Icopal Ltd Barton Dock Road Stretford, Manchester M32 0YL Telephone: 0161 865 4444 Fax: 0161 866 9859 Technical Fax: 0161 865 8433
More information!!! !!!! !!! !!! !!! !!! !!!!!!!!! Table of Contents! Section 1: Most Common Types of Flat Roofing! Section 2: Better Understand Your Flat Roof!
Table of Contents Section 1: Most Common Types of Flat Roofing Section 2: Better Understand Your Flat Roof Section 3: Flat Roofing Cost in 2015: Four Factors that Dictate Section 4: Planning A Flat Roofing
More informationTHERMOTEK SELF ADHESIVE MEMBRANE +G2 OVER WOOD SYSTEM DESCRIPTION SELF ADHESIVE OVER WOOD (8YR) BS-SA/CS
THERMOTEK SELF ADHESIVE MEMBRANE +G OVER DESCRIPTION SELF ADHESIVE OVER (8YR) BS-SA/CS 1 0 No 0. SUBSTRATE 1. BASE SHEET G FIBER GLASS BASE. THERMOTEK SELF ADHESIVE 3.0 FP GRANULE COMPONENTS AND WEIGHTS
More informationYour guide to home maintenance. Flat Roofs
Your guide to home maintenance Flat Roofs Your guide to home maintenance is a series of information leaflets that gives you all the information you need to keep your home in tiptop condition. Flat Roofs
More informationPlease read the entire document before purchasing and installing any of these products
Please read the entire document before purchasing and installing any of these products USA SBS UNDERLAYMENT ROOFING UNDERLAYMENT SBS Mineral Surfaced MINERAL SURFACE CAP SHEET Ice and Water Protection
More informationThe existing roof angle change terminations and flashings when sound and intact can be reused.
January 2, 2015 Summary Specification Re-Skinning an Existing Roof Maintenance and Repair Warranty Upgrade for Up to 30 Years Re-Skinning Over an Existing Roof with a New C-EPDM Membrane Using The Existing
More informationConcrete Waterproofing Systems. Integral Protection. www.tritonsystems.co.uk
Concrete Waterproofing Systems Integral Protection n Type B Integral Protection in accordance with BS 8102 (2009) n Unique chemical admix for waterproofing and protection of concrete n A complete and permanent
More informationTechnology at its best. Benefits
Protecting what s under your roof from the elements is simplicity itself with Ruberoid Roofing Shingles. Roofing Shingles make ideal roofing; they are attractive, easy to install and are perfect for use
More informationShingle Roofing: What s below the surface is important
What s below the surface is important The roof is leaking, the shingles look old, and the downspouts are dripping. It must be time to replace the roof or is it? Shingle roofs may seem simple, but a roof
More informationChapter 9: INSTALLING ROOFING
9.1 LEAK BARRIER (ICE AND WATER SHIELD) 9.2 SHINGLE UNDERLAYMENT 9.3 INSTALLING GUTTER APRON AND GABLE D-EDGE 9.4 INSTALLING SHINGLES 9.5 RIDGE VENT AND CAP Tools needed by each volunteer: Hammer (16 oz.
More informationSELF-INSPECTION CHECKLIST Maintain Your Roof and Identify Potential Issues With Bloom s Comprehensive Self-Inspection Guide
SELF-INSPECTION CHECKLIST Maintain Your Roof and Identify Potential Issues With Bloom s Comprehensive Self-Inspection Guide Inspection Questions? Call Bloom At 800-483-9932 www.bloomroofing.com DISCLAIMER
More informationSuperform Products Ltd.
TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000
More informationCI/SfB (47) Ln2 FLAT ROOF SOLUTIONS
CI/SfB (47) Ln2 FLAT ROOF SOLUTIONS HOT MELT STRUCTURAL WATERPROOFING ENVIRONMENTAL & TECHNICAL The 790-11 rubberised asphalt is formulated with a percentage of post-consumer recycled materials. With no
More informationLow Energy Low Carbon Buildings
I n s u l a t i o n CI/Sfb (27.9) Rn7 M2 Eighth Issue March 2011 TR27 LPC/FM INSULATION FOR FLAT ROOFS WATERPROOFED WITH FULLY ADHERED SINGLE PLY, PARTIALLY BONDED BUILT UP FELT, MASTIC ASPHALT AND COLD
More informationBITUMEN-POLYMER WATERPROOFING MEMBRANE, MADE FROM SELECT APP AND DISTILLED BITUMEN, REINFORCED WITH SPUNBOND POLYESTER FABRIC.
93-106 Revised March 2007 BITUMEN-POLYMER WATERPROOFING MEMBRANE, MADE FROM SELECT APP AND DISTILLED BITUMEN, REINFORCED WITH SPUNBOND POLYESTER FABRIC. BITEC APM-4.5T is a torch applied, mineral surfaced,
More informationInterior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM
P r o d u c t a p p l i c a t i o n s a n d t e c h n i c a l i n f o r m a t i o n 2 below and above ground V OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM V The flexible, fast and cost-effective answer
More informationHEB 38 BLANCO AND WEST AVENUE FLUID APPLIED EPDM RUBBER ROOF RECOVERY SYSTEM APPLICATION
HEB 38 BLANCO AND WEST AVENUE FLUID APPLIED EPDM RUBBER ROOF RECOVERY SYSTEM APPLICATION David Marut TEST CASE REPORT July 1, 2014 Case Study Pro Guard EPDM Super Coat Liquid Rubber Membrane Roof System
More informationDocument type: Practice Note Title: External and internal membranes Document number: AC2234 Version: 5. 1. Purpose
Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: 5 1. Purpose The purpose of this practice note is to address the incidence of deck and roof membrane
More informationITEM 599.06060008 THERMOPLASTIC MEMBRANE ROOFING
DESCRIPTION Construct adhered membrane roofing system, roof insulation, and vapor retarder in accordance with these specifications. MATERIALS: General: Provide installed roofing membrane and base flashings
More informationSHINGLE APPLICATION GUIDE
SHINGLE APPLICATION GUIDE CONTENTS 01. General conditions 01. Material requirements 02. Terms 07. Estimating shingle requirements 08. Roof preparation 10.Shingle application E version 2006 GENERAL CONDITIONS
More informationTHERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER
THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER DESCRIPTION TORCH OVER (15,17,19 YR) TH/BS-TH/CS 2 1 0 No 0. SUBSTRATE 1. THERMOTEK USA 2.0 FV TORCH SMOOTH 2. THERMOTEK USA PRO FP TORCH GRANULE COMPONENTS
More informationInstallation Manual for STANDING SEAM ROOFING
Installation Manual for STANDING SEAM ROOFING Absolute Steel Toll Free 877-833-3237 / Phone 480-768-1618 / Fax 480-768-1514 www.metalroofingsource.com Standing Seam features approximately one-inch high
More informationRegulations Detail Sheet 1
Designated by Government to issue European Technical Approvals Esha (UK) Ltd Esha House St Mary s Business Park Albany Road Market Harborough Leicestershire LE16 7EB Tel: 01858 410372 Fax: 01858 410572
More informationFig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION
SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.
More informationLONDON BOROUGH OF HACKNEY BUILDING SERVICES ENGINEER REPORT GAS HOUSE, SPRINGFIELD PARK, HACKNEY
LONDON BOROUGH OF HACKNEY BUILDING SERVICES ENGINEER REPORT GAS HOUSE, SPRINGFIELD PARK, HACKNEY 10 TH JUNE 2011 London Borough of Hackney Page 1 of 6 Brief Description of the Proposed Works The existing
More informationTHERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER POLYSOCYANURATE SYSTEM DESCRIPTION TORCH SYSTEM OVER POLYISO (15,17,19 YR) TH/BS-TH/CS
OPTIONAL TITLE 24 CRITICAL POINTS POLYISO THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER POLYSOCYANURATE DESCRIPTION TORCH OVER POLYISO (5,7,9 YR) TH/BS-TH/CS 2 No 0. SUBSTRATE. THERMOTEK USA PRO 2.0 FV
More informationDiscount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions
Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions All questions and concerns please call 904-696-9700 Discount Direct Metal Roofing Plus Rib metal roofing panels are a strong,
More informationLarry Haight's Residential Roofing Co, Inc 15203 NE 95th Street Redmond, Washington Phone: (425) 881-9771 Fax: (425) 869-1010
Larry Haight's Residential Roofing Co, Inc 15203 NE 95th Street Redmond, Washington Phone: (425) 881-9771 Fax: (425) 869-1010 Custom bid generated for: Job site address: Lake Villas Condominium Attention:
More informationSPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING. 16.1 General...16-1. 16.2 Materials...16-1. 16.3 Equipment...
SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING TABLE OF CONTENTS 16.1 General...16-1 16.2 Materials...16-1 16.3 Equipment...16-1 16.4 Installation...16-2 16.4.1 Traffic Restrictions...16-2
More informationSPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION
SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION 1. SCOPE Pipe subsoil drains shall be constructed in accordance with this specification and in conformity with the lines, grades and cross-sections shown
More informationKAHU RESIDENTIAL ROOFING RRKA DETAIL LIST
KAHU DETAIL LIST 00 / 24 COVER SHEET 01 / 24 ROOF RIDGE 02 / 24 SAWTOOTH RIDGE 03 / 24 SAWTOOTH EAVE 04 / 24 ROOF VALLEY 05 / 24 ROOF - CHANGE PITCH 06 / 24 EAVE WITH METALLINE FASCIA 07 / 24 EAVE WITH
More informationINSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels
INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels Grand Rib-3 / Multi-Purpose / Classic Rib Grand Rib-3 / Multi-Purpose / & Classic Rib Grand Rib 3 panels are a strong,
More informationSECTION 07 61 13 STANDING SEAM METAL ROOFING
SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced
More information