Figure 1: MyChron 3 XG LOG

Similar documents
MXG Dash Logger USER GUIDE

MXL2 Dash Logger USER GUIDE

MyChron Expansion User Manual

Dear MyChron 3 Plus/Gold Owner

K-Type Thermocouple Sensor User s Guide

Dear MyChron 3 Owner

FORMULA STEERING WHEEL User Manual

Yamaha R1 2007/2008/2009 R6 2006/2007/2008 Plug&Play kit user manual

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

Transmitter Interface Program

User Manual for CH-PFC76810

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

MyChron4 User Manual

Omega ICD Intelligent Colour Display

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited

1. SAFETY INFORMATION

USB-500 Series Stand-Alone, Low-Cost Data Loggers

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Current Monitoring Kit QUICK START GUIDE

Current Monitoring Kit

ECU MS 3 Sport GT3 Cup. Quick Start Manual

MOTION COORDINATOR MC206X Quick Connection Guide

Ordering Part Numbers:

T3 Mux M13 Multiplexer

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

MoTeC USA GPS. Part # M GPS BL Available in 10 Hz or 20 Hz. USER MANUAL Version 1.4

with Electronic Assistant

Prislista Alla priser är inkl moms.

A-307. Mobile Data Terminal. Android OS Platform Datasheet

SNMP Web Management. User s Manual For SNMP Web Card/Box

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

DASH2 General Layout. Figure 1: DASH2 general layout

Cell Phone Vibration Experiment

PC SERIAL INTERFACE FOR LAMBDA GAS CONTROL LGC-700

NC-12 Modbus Application

Parts List. Navigation

Defi Meter C Application User s Guide

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

TS1 Ultra Sonic Tank Sender Training. 27 November 2007

NETWORK ENABLED EQUIPMENT MONITOR

2X1 DVI Switch (DS-21R) 4X1 DVI Switch (DS-41R) USER MANUAL. DTronics Inc.

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

MANUAL FOR RX700 LR and NR

ATL Fuel Level Sender Probes

USB-500/600 Series Low-Cost Data Loggers and Accessories

PL-1, Pocket Logger B

Six-servo Robot Arm. DAGU Hi-Tech Electronic Co., LTD Six-servo Robot Arm

DAKTON µ BOX MANUAL µbox User Manual 1

RPLIDAR. Low Cost 360 degree 2D Laser Scanner (LIDAR) System Development Kit User Manual Rev.1

INTRODUCTION TO SERIAL ARM

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

MANUAL PC1000R

INTRODUCTION. 3 PARTS SUPPLIED. 3 BEFORE YOU BEGIN. 3 CONNECTING THE ECU INTERFACE TO OTHER EQUIPMENT. 11 DATA OUTPUT CHANNELS.

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Unidirectional Transmitter/ Receiver Units Introduction

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

Software manual Displays and Dash

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Series 7500 Torque Sensor

Work with Arduino Hardware

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

LDG DTS-4/4R Desktop Coaxial Switch / Remote

Fuel Alert FA-KRS-P21. Mounting instruction

BASLER ACE QUICK INSTALLATION GUIDE

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Keep it Simple Timing

[USING THE NM150 WITH ADULTICIDING] July 13, 2015

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

MS830 / MS833 Barcode Reader v1.0 9-December-2014

UPS Network Interface. Quick InstallationGuide

TDAS G5-DB Hardware User s Manual

PITE 3921 Battery Monitoring System User Manual P V1.0

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

2100 POS System User Guide

PD 100A. Printing data system

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

computer radio control system

G-100/200 Operation & Installation

ATB50v1 GPRS / GPS Based Fleet Management Terminal. Datasheet

Lab 4 - Data Acquisition

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Electronic Control Devices The European Product Catalogue 2007

CRE Monitor Instructions Manual

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

PROCESSOR CONFIGURATION SOFTWARE USER GUIDE

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

USER MANUAL V5.0 ST100

Mirror Mount Video Monitor/Recorder with Front and Rear View Night Cameras PLCMDVR5

Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: Version 1.0

Table of Contents Getting Started... 3 The Motors... 4 The Control Board... 5 Setting up the Computer with Mach Starting up the Equipment...

USB-500 Series Low-Cost Data Loggers and Accessories

Bluetooth HC-06 with serial port module Easy guide

US-Key New generation of High performances Ultrasonic device

Transcription:

TECHNICAL DOCUMENTATION 9/06/2005 GAUGE Notes: MyChron 3 XG LOG technical documentation, dimensions and pinout Version 1.07 MyChron 3 XG LOG Internal lateral accelerometer CH1 Beacon Speed CH2 CH3 CH4 Figure 1: MyChron 3 XG LOG Introduction MyChron 3 XG LOG represents the perfect synthesis between MyChron 3 Gold XG and MyChron 3 LOG advanced for car applications: this new logger merges the functionalities and the features of those 2 previous loggers and constitutes a milestone moment in AIM data logger history. MyChron 3 XG LOG monitors and displays, 5 fully configurable analog inputs (pressure, temperature, potentiometers, Lambda probe and Pitot tube, speed sensors), 2 speed inputs, internal lateral G-sensor (to map tracks), gear number and lap (split) times. MyChron 3 XG LOG is interfaceable with the most common, like Bosch, Carmo, Efi, MecTronic, MoTec and others, through an RS232 cable or a CAN cable (connected to the gauge --POWER input) to sample the data out coming from the. To have a complete list of compatibles s, communication protocol and connection with AIM logger, please refer to documents page of our website www.aim-sportline.com, where You find a dedicated datasheet called -AIM logger. The logger records the following parameters: 5 analog inputs: pressure and temperature sensors (VDO, thermoresistors, thermocouples), potentiometers (linear and circular), Lambda probe and Pitot tube; lap and split times; 2 speed inputs; Internal lateral G-sensor to map tracks; Gear number; Logger s temperature; All the channels acquired from the engine s. Technical documentation: MyChron 3 XG LOG Version 1.07 1

Data are stored in a huge 8 Mbytes internal flash memory and may be downloaded to a PC through an USB cable. For further information on the gauge s display, please refer to the following drawing. Gear display 10 fully configurable shift lights Speed unit of measure graphical bar Configurable scaling Low battery warning Night vision digital value Speed Best lap time Battery voltage 2nd displayed channel Temperature unit of measure 1st displayed channel 4 alarm led: from "AL 1" to "AL 4" Lap / Split times Displayed input channels USB port Figure 2: MyChron 3 XG LOG display Installation notes We recommend to choose a place where the instrument will not be in contact with oil or fuel, be sure that the gauge is not installed too close to heat sources and protect the instrument from vibrations; We remind you that MyChron 3 XG LOG is not equipped with internal batteries, so it needs to be powered by an external 9 15V power source (i.e. the car s battery). Do not exceed these limits. Speed direction Lateral accelerometer In order to correctly measure the lateral g-force using the internal accelerometer, it is suggested to install the gauge with the Junction box s front panel perpendicular to the vehicle s speed, as shown in Figure 3. Figure 3: How to correctly install Your MyChron 3 XG LOG (Junction box s top side view) Once the gauge and the Junction box have been correctly installed, you may plug all the sensors inside the junction box front panel; Moreover, you may connect the gauge to the engine s using the serial/can cable. Technical documentation: MyChron 3 XG LOG Version 1.07 2

How to use the --POWER input Your MyChron 3 XG LOG is equipped with a 7 pins female connector labelled as --POWER. This multi-purpose connector is used for: connection CAN protocol connection RS232 serial protocol input: external 9 15V power source, RED (+) and BLACK (-) wires; input: the logger has 2 supplementary inputs for coil (150-400 V) or square wave (8-50 V) signals. Usually the signal is sampled from the and so you do not need to use one of these 2 wires. To connect your MyChron 3 XG LOG to the, please use the serial RS232 / CAN cable and connect it to the gauge as shown in Figure 4. Please note that your may be equipped with a CAN or with an RS232 serial communication protocol, so you do not have to connect both CAN + / CAN - and RS232 TX / RS232 RX wires to the, but only the ones concerning the correct communication protocol. CH1 Beacon Speed RS232 TX & RS232 RX GND CAN + & CAN - } ENGINE'S CH2 CH3 CH4 Figure 4: How to connect Your MyChron 3 XG LOG To the How to connect MyChron 3 XG LOG to the PC In order to connect your MyChron 3 XG LOG to the PC, please use the USB data download cable and plug it both in the gauge s USB port and in the PC s USB port, as explained in Figure 5. Moreover, please use a 9-15 Volts external power source to switch on the gauge. CH1 Beacon Speed CH2 CH3 CH4 Figure 6: How to connect Your MyChron 3 XG LOG to the Pc Technical documentation: MyChron 3 XG LOG Version 1.07 3

Software Once the logger installed and the sensors plugged in, to configure the logger,please use Race Studio 2, the software developed by Aim to configure its instruments and analyze stored data. Please run Race Studio 2, select M3 LOG / VISOR/XGLOG, press System manager button and follow these steps: 1) Set the input channels Press Channels button to set the sensors installed on your car; this window appears. To set an input channel, double-click on the cell corresponding to the desired one: the pop up window circled above appears. 2) How to configure the gauge Once set the desired input channels, press Configuration button to set all the other parameters. The window below appears. To correctly configure your MyChron 3 XG LOG, please set all parameters reported in the configuration window shown in the previous figure: Display language. Obscuring time and Number of splits. Speed channel, wheel circumference and pulses per wheel revolution. Channels and alarms concerning the 2 display pages. Gear channel: calculated or none 3) Transmit the configuration Once the input channels set and configured to transmit the configuration to the logger please press OK button and than Transmit button on the following wndow. Please note: to transmit the configuration, the gauge must be switched on and connected to the PC, as shown in Figure 5. 4) Calibrate/auto-calibrate sensors After configuration transmission you have to calibrate/auto-calibrate the sensors. Potentiometer distance and Internal lateral accelerometer sensors need autocalibration, while Mid zero potentiometer, zero based potentiometer and on-board gear sensor need calibration. Please press Calibrate button and this window appears G-force sensor and potentiometer distance sensor need to be auto-calibrated pressing 5) Re-transmit the configuration Once the calibration/autocalibration has Technical documentation: MyChron 3 XG LOG Version 1.07 4

button Click here to auto-calibrate all sensors in the list. To calibrate on-board gear sensor, Mid zero potentiometer or zero based potentiometer, click on the corresponding Calibrate button and follow the instructions prompted on your PC s monitor. Please note: calibration/auto calibration procedure is fundamental to acquire correct data. finished, it is absolutely necessary to retransmit the configuration to your MyChron 3 XG LOG pressing the Transmit button. Technical documentation: MyChron 3 XG LOG Version 1.07 5

Dimensions in millimetres [inches] 126 [4,96] 48 [1,89] 87 [3,43] 120 [4.72] 110 [4.33] 100 [3,94] CH1 Beacon Speed 4 [0,16] 39 [1,54] CH2 CH3 CH4 Channels 1 5 pinout 1 Analog input 3 +V battery 2 GND 4 V reference 4 1 3 2 7 1 6 2 5 4 3 Speed channel pinout 1 Speed 1 3 +V battery 2 GND 4 Speed 2 Beacon channel pinout 1 Magn. / Opt. codified lap 3 +V battery 2 GND 4 Optic not codified lap --POWER channel pinout 1 CAN + 5 RS232 RX 2 CAN - 6 150-400 V (coil input) and Sq. Wave (>8V) 3 + V batt. 7 GND 4 RS232 TX 4 & 7 pins female Binder 712 connectors pinout: external view Technical characteristics General characteristics Value Input channels 5 Input ch. from Max. 64 Max sampling freq. Up to 200 Hz per channel Total sampling 1000 Hz frequency Internal g-sensor Biaxial, ±10g External power From 9 to 15 VDC Voltage output (V ref.) 4.5 V (for potentiometers) Internal memory 8 Mb flash EPROM interface Serial / CAN protocol PC interface 300 kbyte/sec USB port Other characteristics Value M3 XG LOG dimensions 126x92x24 mm Display dimensions 87x48 mm Environmental IP 65 Technical documentation: MyChron 3 XG LOG Version 1.07 6