VL Circuit Breaker JG 400A frame

Similar documents
VL circuit breakers. Information guide.

General information Circuit breakers for power distribution T1 T3

Sentron Series Circuit Breakers

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

Tmax MCCBs. Molded case circuit breakers. Tmax

Molded case circuit breakers

Index Molded case circuit breakers. Molded case circuit breakers. Tmax UL489B Photovoltaic circuit breakers

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Bulletin 1489 Circuit Breakers. Selection Guide

Decision-Maker Paralleling System. Power Distribution Switchboards and Circuit Breakers. Standard Features

Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers

Circuit Breakers. Next Generation of Protection Capabilities

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600

Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data

Tmax. Molded case circuit breakers. Phone: Fax: Web: info@clrwtr.com. Tmax.

CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS

Data Bulletin. Choosing a Trip Unit for PowerPact H-, J-, and L-Frame Circuit Breakers. Introduction. Thermal-Magnetic or Electronic Trip Unit?

PREFACE. The products covered by this Guide are:

Mining service breakers with true rms sensing designed specifically for trailing cable applications

AC1645. System pro M compact Supplementary Protectors Miniature MCCBs

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Mining service breakers with true rms sensing designed specifically for trailing cable applications

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Electronic overload relay EF19 and EF45

Low voltage circuit breakers. Working with trip characteristic curves

BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES

Miniature Circuit Breakers and Supplementary Protectors

SENTRON Switching and Protection Devices Air Circuit Breakers

Catalog January. Heavy industrial power applications Motor contactors and starters

Working with the Trip Characteristic Curves of ABB SACE Low Voltage Circuit-Breakers 1SDC007400G0201

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Circuit Breakers Supplementary Protectors Manual Motor Controllers

Distribution Dry Type Transformers

Bimetallic Overload Relay Specifications

Certificate of Compliance

Operation and Maintenance manual. fusible shunt trip switch

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Product Guide. Cable-in / cable-out miniature circuit breakers and supplementary protectors

8146/5 Series Breaker Panelboards

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Alternate Methods to Short Circuit Breaker Coordination

EATON I.L. 29C615E. 4.3 Short Delay/lnstantaneous Trip Ground Fault Protection Protection Settings... 7

Data Bulletin. Circuit Breaker Characteristic Trip Curves and Coordination Class 0600 TRIP CURVES AND COORDINATION CIRCUIT BREAKER TRIP CURVES

Thermal-Magnetic Circuit Breaker M1-..

Electronic overload relay EF65, EF96 and EF146

Instructions for ND, CND, HND, CHND, NDC and CNDC Circuit Breakers and N-frame Series C Molded Case Switches

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Bolted contact switches. Pringle switches

CONDUCTOR SHORT-CIRCUIT PROTECTION

AP/UP, AP/MIL Series. Magnetic Circuit Protectors

PowerPact D-Frame Circuit Breakers and Switches 150 to 600 A

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Manual motor starter MS116

British BS 88 Fuses. Introduction

Breaking and protection devices

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

FLB Series Circuit Breakers and Enclosures

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

Westinghouse AB DE-ION Current Limiting Circuit Breakers

Rotary Disconnect Switch Specifications

5SV Residual Current Protective Devices

How To Operate A Gec Transfer Switch Open Transition Amp Power Supply

CUSTOMER CLASS FILE. ABB STOTZ-KONTAKT GmbH _0_000

Secondary Unit Substations

Overcurrent Protection

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

How To Protect A Motor From Overcurrent

NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION. Super Solution

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

GE Consumer & Industrial Electrical Distribution. Power Break II. Insulated Case Circuit Breakers

D-Line Contactors, Overload Relays and Accessories

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

OVR-3SP Recloser with PCD Control Style Guide 1VAL SG March 30, 2009 Revision B

Primary and Secondary Electrical Distribution Systems

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Reverse-feed applications for circuit breakers

Low Voltage Products. Switches Automatic Transfer Switches

LCP Coordination Panel Operations & Maintenance Manual Table of Contents

Soft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D E 0 VD00

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Installation Instructions

Data Bulletin Variable Frequency Drives and Short-Circuit Current Ratings

RM4TG20 three-phase network control relay RM4-T - range V

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Bulletin 150 SMC Flex Smart Motor Controller Specifications

CATALOG #250

STANDARDS AND RATINGS FOR THE APPLICATION OF MOLDED CASE, INSULATED CASE, AND POWER CIRCUIT BREAKERS

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

LVA Take Offs in Bid Manager

Type: DILM9 10(24VDC) Article No.:

SPEEDFAX TM 2011 Disconnect Switches Contents

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

R.C.C.B. s two-pole LEXIC

IZM ACB/Circuit-breakers. Robust safety. Extract from Main Catalogue HPL2010 IZM26 Circuit-breakers IN26 Switch-disconnectors

Transcription:

M4-PAN-TORX M4-PAN-TORX VL Circuit Breaker JG 400A frame Breaker type Defined by the 3rd character of the catalog number G Global (UL, CSA, IEC, CE, CCC), interchangeable X Global, Non-interchangeable Y Global, 100% rated, Non-interchangeable Trip unit type Defined by the 5th character of the catalog number B Thermal-magnetic, model 525 N LI, electronic, model 545 P LSI, electronic, model 545 X LIG, electronic, model 545 U LSIG, electronic, model 545 D LSI, electronic with LCD, model 576 E LSIG, electronic with LCD, model 576 For DC applications, use thermal magnetic trip unit only. For reverse-feed applications, select non-interchangeable trip breakers only. HACR rated. R LI, electronic, Model 555 T LSI, electronic, Model 555 W LIG, electronic, Model 555 V LSIG, electronic, Model 555 A LSI, electronic with LCD, Model 586 G LSIG, electronic with LCD, Model 586 K LSI + GF alarm, electronic with LCD, Model 586 Interrupting ratings RMS symmetrical amperes (ka) UL 489 IEC 60947-2 UL or IEC Volts AC Volts AC Volts DC a Interrupting Breaker 240 480 600 240 415 690 Class Type I cu /I cs I cu /I cs I cu /I cs 250 500 600 b N NFGA 65 35 25 65 / 65 40 / 40 12 / 6 30 25 H HFGA 100 65 25 100 / 75 70 / 70 15 / 8 30 35 65 L LFGA 200 100 25 200 / 150 100 / 75 15 / 8 30 35 UL / CSA / NOM 40ºC 50/60Hz IEC 40ºC 50/60Hz a For DC applications and wiring diagrams, see p. 5 of VL Information Guide. b Special version, Type HFGD. See Speedfax catalog for more information. Trip Unit Model 525 Thermal magnetic trip units, model 525 I n Trip unit rating (amps) I i Nominal instantaneous trip adjustable range (amps) 250 1250 1500 1750 2000 2250 2500 300 1500 1800 2100 2400 2700 3000 350 1750 2100 2450 2800 3150 3500 400 2000 2400 2800 3200 3600 4000 2400 2800 AMPS I i 3200 3600 2000 4000 Trip Unit Model 545 Electronic trip units, Model 545 with LI (Trip unit type N) or LIG (Trip unit type X) Trip Functions = I n 40º C TM ~ 400A Trip Unit/Disparador 525 Trip unit model 525 250 70 80 100 125 150 160 175 200 225 250 400 150 160 175 200 225 250 300 315 350 400 rating (amps) t r Long time delay switch settings (seconds) Pt @ 6 x I r 250, 400 2.5 4 6 8 10 14 17 20 25 30 rating (amps) I i Nominal instantaneous trip switch settings (amps) 250 312 375 500 750 1000 1250 1500 2000 2500 2750 400 500 600 800 1200 1600 2000 2400 3200 4000 4400 Fixed settings (LIG only) rating (amps) I g Ground fault pickup (amps) t g Ground fault delay 250 200.07 sec 400 320.07 sec Trip unit model 545 21

Trip Unit Model 545 (continued) Electronic trip units, Model 545 with LSI (Trip unit type P) or LSIG (Trip unit type U) Trip Functions 250 70 80 100 125 150 160 175 200 225 250 400 150 160 175 200 225 250 300 315 350 400 rating (amps) I sd Short time pick-up switch settings (amps) x I r 250, 400 1.5 2 2.5 3 4 5 6 7 8 10 rating (amps) t sd Short time delay switch settings (seconds) @ 8xl r 250, 400 0 0.1, I 2 t OFF 0.2, I 2 t OFF 0.3, I 2 t OFF 0.4, I 2 t OFF 0.5, I 2 t OFF 0.1, I 2 t ON 0.2, I 2 t ON 0.3, I 2 t ON 0.4, I 2 t ON Fixed settings rating (amps) t r Long time delay I i Nominal instantaneous trip I g Ground fault pick-up (LSIG only) t g Ground fault delay (LSIG only) 250 10 sec. (I 2 2750A 200A.07 sec. t @ 6 x I r ) 400 4400A 320A.11 sec Trip Unit Model 555 Switch 4 Electronic trip units, Model 555 with LI (Trip unit type R) or LIG (Trip unit type W) Trip Functions Switch 4 (LIG Only) 250 70 80 100 125 150 160 175 200 225 250 400 150 160 175 200 225 250 300 315 350 400 rating (amps) t r Long time delay switch settings (seconds) I 2 t @ 6 x I r 250, 400 2.5 4 6 8 10 14 17 20 25 30 I n - Trip unit rating (amps) I i - Nominal instantaneous trip switch settings (amps) 250 312 375 500 750 1000 1250 1500 2000 2500 2750 400 500 600 800 1200 1600 2000 2400 3200 4000 4400 rating (amps) I g - Ground fault pick-up switch settings (amps) 250 200 100 100 100 150 150 150 250 250 250 400 320 160 160 160 240 240 240 400 400 400 rating (amps) t g Ground fault delay switch settings (seconds) 250 0.07 0.10 0.20 0.30 0.10 0.20 0.30 0.10 0.20 0.30 400 0.11 0.10 0.20 0.30 0.10 0.20 0.30 0.10 0.20 0.30 22

Trip Unit Model 555 (continued) Switch 4 Electronic trip unit, Model 555 with LSI (Trip unit type T) Trip Functions Switch 4 250 125 150 200 225 250 125 150 200 225 250 400 200 250 300 350 400 200 250 300 350 400 rating (amps) t r Long time delay switch settings (seconds) I 2 t @ 6 x I r 250 4 4 4 4 4 14 14 14 14 14 400 10 10 10 10 10 20 20 20 20 20 rating (amps) I sd Short time pick-up switch settings (amps) x I r 250, 400 1.5 2 2.5 3 4 5 6 7 8 10 rating (amps) t sd Short time delay switch settings (seconds) 250, 400 0 0.1, I 2 t OFF 0.2, I 2 t OFF 0.3, I 2 t OFF 0.4, I 2 t OFF 0.5, I 2 t OFF 0.1, I 2 t ON 0.2, I 2 t ON 0.3, I 2 t ON 0.4, I 2 t ON rating (amps) I i Nominal instantaneous trip switch settings (amps) 250 312 375 500 750 1000 1250 1500 2000 2500 2750 400 500 600 800 1200 1600 2000 2400 3200 4000 4400 Electronic trip unit, Model 555 with LSIG (Trip unit type V) Trip Functions Switch 4 250 125 150 200 225 250 125 150 200 225 250 400 200 250 300 350 400 200 250 300 350 400 rating (amps) t r Long time delay switch settings (seconds) I 2 t @ 6 x I r 250 4 4 4 4 4 14 14 14 14 14 400 10 10 10 10 10 20 20 20 20 20 rating (amps) I sd Short time pick-up switch settings (amps) x l r 250, 400 1.5 2 2.5 3 4 5 6 7 8 10 rating (amps) I i Nominal instantaneous trip switch settings (amps) x l n 250, 400 5 5 5 5 5 11 11 11 11 11 rating (amps) t sd Short time delay switch settings (seconds) 250, 400 0 0.1, I 2 t OFF 0.2, I 2 t OFF 0.3, I 2 t OFF 0.4, I 2 t OFF 0.5, I 2 t OFF 0.1, I 2 t ON 0.2, I 2 t ON 0.3, I 2 t ON 0.4, I 2 t ON rating (amps) I g Ground fault pick-up switch settings (amps) 250 200 100 100 100 150 150 150 250 250 250 400 320 160 160 160 240 240 240 400 400 400 rating (amps) t g Ground fault delay switch settings (seconds) 250 0.07 0.10 0.20 0.30 0.10 0.20 0.30 0.10 0.20 0.30 400 0.11 0.10 0.20 0.30 0.10 0.20 0.30 0.10 0.20 0.30 23

Trip Unit Model 576 and 586 X3 440JM ESC Electronic trip units with LCD Model 576 (Trip unit type D and E) or Model 586 (Trip unit type A, G and K) I n Trip unit rating (amps) Trip unit model 576 Trip unit model 586 I r Continuous amps range a t r Long time delay settings (I 2 t @ 6 x I r ) Motor circuit protectors Amp I i Nominal instantaneous trip rating adjustable range (amps) 400 1200 2500 a 400 2000 4000 b a Settings adjustable in increments of 250 amps. b Settings adjustable in increments of 400 amps. 600 V DC circuit breakers Amp rating Short-circuit rating 600 V DC 250, 300, 350, 400 65 ka I sd Short time pick-up range t sd Short time delay settings Ii Nominal instantaneous trip range ab 313-2750A 250 70-250 2.5, 4, 6, 8, 10, 14, 0.1, 0.2, 0.3, 0.4, 0.5 sec. 1.25-10 x I 400 150-400 17, 20, 25, 30 sec. r or I 2 t @ 8 x I r 500-4400A I g Ground fault t g Ground Pre-alarm rating (amps) pick-up range a fault delay indication 250 100-250A 0.1, 0.2, 0.3, 0.4, 0.5 sec. 80-100% 400 160-400A I2t @.5 x I n x I r (Amps) a Current settings are adjustable in 1-amp increments. b Model 586, can turn function OFF. Instantaneous trip override function will be enabled to ensure self protection of circuit breaker. Molded case switch Amp rating Self-protective instantaneous override Short-circuit current rating 480 V AC a 400 4400A 65 ka 400 4400A 100 ka a Max. available current when protected by an appropriate overcurrent protective device. 24

Terminal Connectors Wire range Cables per connectors Wire range Torque Ib-in. (Nm) Catalog number 1/0 600 kcmil 1 (Cu only) #1/0 600 330 (24.86) 3TW1JG600 a 3/0 250 kcmil 2 (Cu / Al) #3/0 250 275 (31.07) 3TA2JG250 ab 3/0 250 kcmil 2 (Cu only) #3/0 250 275 (31.07) TC2JG250 c 3/0 750 kcmil 1 (Cu only) 3/0 750 kcmil 1 (Cu / Al) Compression connector kits #3/0 250 300 750 #3/0 250 300 750 275 (31.07) 500 (56.59) 275 (31.07) 500 (56.49) TC1JG750 c 3TA1JGG750 a #6 350 1 (Cu / Al) 3CLJ350 a 250 600 1 (Cu / Al) 3CLJ600 a 250 750 1 (Cu / Al) 3CLJ750 a Distribution connector kits #14 2/0 6 (Cu / Al) #14 #10 #8 #6 2/0 35 (3.95) 40 (4.52) 120 (13.56) 3TA6JG20 a #14 #4 6 (Cu only) #14 #4 35 (3.95) 3TA12JG04 a a Packaged as 3 connectors. b Standard connectors when an L suffix is used on an assembled breaker catalog number. c Required for 100% rated JG breakers. Requires 90ºC cable sized at 75ºC ampacity. Internal accessories Auxiliary and alarm switch kits Description Mounting pocket Catalog number 1 Alarm switch 1 A/B a bases AMBL2 and AMBL3 Left, rightb ASKL1 2 Aux. switches 1A + 1B base AMBL1 Left, right ASKL2 2 Aux. + 1 Alarm switch 1A + 1B, 1A/B bases a AMBL2 and AMBL3 Left, right b ASKL3 a Includes 1A and 1B contact for alarm purposes, only one of which may be installed at any time. b Kit includes 2 bases - one for mounting switches in left pocket and another for mounting in right pocket. Auxiliary and alarm switch mounting base only Description Mounting pocket Catalog number For 2 Aux + 1 Alarm Left AMBL2 For 2 Aux + 1 Alarm Right AMBL3 For 3 Aux Left, right AMBL1 Shunt trip Control voltage Catalog number 48 60 VAC STRLM60 110 127 VAC STRLN120 208 277 VAC STRLS277 380 600 VAC STRLV600 24 VDC STRLB24DC 48 60 VDC STRLC60DC 110 127 VDC STRLD125DC 220 250 VDC STRLE250DC Shunt trips or UVR s may be mounted in the Right Pocket only. Internal accessory locations Left accessory pocket Right accessory pocket Up to 3 auxiliary switches Shunt trip or UVR or up to 3 auxiliary switches Up to 2 auxiliary switches + 1 alarm switch Maximum of 6 switches total. Maximum of 2 alarm switches, 1 Left + 1 Right Pocket. Shunt trip or UVR or up to 2 auxiliary switches + 1 alarm switch Auxiliary / Alarm switches only (requires a base) Description Catalog number 1 NO (normally open contact) ASWPA 1 NC (normally closed contact) ASWPB (A) Normally open contacts are open when the breaker contacts are open. (B) Normally closed contacts are closed when the breaker contacts are open. Undervoltage release Control voltage Catalog number 110 127 VAC UVRLN120 220 250 VAC UVRLR240 208 VAC UVRLP208 277 VAC UVRLS277 380 425 VAC UVRLT415 440 480 VAC UVRLU480 12 VDC UVRLA12DC 24 VDC UVRLB24DC 48 VDC UVRLC48DC 60 VDC UVRLG60DC 110 127 VDC UVRLD125DC 220 250 VDC UVRLE250DC 25

Y X Y X Dimensions (complete breaker) 1.75 [44.5] 1.75 [44.5] 6.44 [163.5] 5.44 [138.5] 4.52 [115] 4.19 [106.5] 4.00 [101.5] Z.19 [5] JG FRAME 1.75 [44.5] (3P).87 [22] (3P) 11.00 [279.5] 5.93 [150.5] 4.66 [118.5] 8.48 [215.5].59 [15] 1.26 [32] 5.91 [150] 2.66 [67.5] 3.25 [82.5] 1.63 [41.5] 1.26 [32] 1.74 [44] X 1.83 [46.5] 5.30 [134.5] 9.75 [247.5] NFT00787 5.47 [139] (3P).96 [24.5] 1.31 [33] 2.73 [69.5] ø.33 [ø8.5] CLEARANCE FOR M8.65 [16.5].19 [5] JG FRAME 4X ø.28 [ø7] 2.42 [61.5] 1.21 [30.5] Y Shipping weight, lbs. (kg) Complete Poles Frame Trip unit breaker 2,3 31.3 (14.2) 4.0 (1.8) 35.3 (16.0) Permissible mounting positions 90 90 30 30 26