Table of Contents. Pin Assignments Method of Programming Interface selection Reading Mode...11



Similar documents
1.1 Notice Introduction Codes Read Installation Pin Assignment Configuration - General

Barcode Magstripe. Decoder & Scanner. Programming Manual

Programming Menu V3.9

BARCODE READER V 2.1 EN USER MANUAL

Part No. : MUL PROGRAMMING GUIDE

Xi2000 Series Configuration Guide

Barcode reader setup manual

Laser Barcode Scanner User s Manual

Bar Code CCD Scanner OPERATION MANUAL

Voyager 9520/40 Voyager GS9590 Eclipse 5145

MK-SERIE 1000/1500/2000 AllOfBarcode.de Michael Krug Traunstein BARCODE SCANNER

HANDHELD LASER SCANNER

Laser Barcode Scanner

Enter/Exit programming

CD-3860 Bar Code Scanner User s Manual

Index...1. Introduction...3. Installation- Keyboard Wedge...3 RS USB...3. Default Setting for each barcode shown as below:...

Scanner Configuration

E-i. Section E. Code Formatting. E/D = Enable/Disable T/DNT = Transmit/Do Not Transmit EX/DNEX = Expand/Do Not Expand

Allen-Bradley. Bar Code. 2-D Hand-Held. Programming Guide. Bar Code. Scanners. (Cat. No HTG-4)

BI-300. Barcode configuration and commands Manual

DUET / VS800 Scanner. DUET Scanner VS800 Scanner. Programming Kit

S302D. Programming Guide. 2D Imaging Barcode Scanner. Advanced Handheld High-Speed Laser Scanner

Barcode Scanning Made Easy. Programming Guide

DL910 SERIES. Instruction Manual

NOTICE: respective owner. Note: Specification is subject to changes without. notice.


Barcode Scanning Made Easy. WWS500 Programming Guide

Metrologic MS1690 2D Scanner Installation Guide

QuickScan i. QD2100 Barcode Imager. Product Reference Guide

Enter/Exit Programming Mode

MS100 Bar Code Pen Reader

Revision History. Advanced Handheld CCD/Laser Scanner

METROLOGIC INSTRUMENTS, INC. MetroSelect Configuration Guide

METROLOGIC INSTRUMENTS INC. MetroSelect Single-Line Configuration Guide

Wireless Laser Barcode Scanner ils 6300BU. User s Manual

HAND-HELD DEVICES II. Software Configuration Manual

because we care MS910 Wireless Barcode Scanner Quick Guide Full user s manual is available on the enclosed CD. Version G

MINIMAG. Magnetic Stripe Reader Keyboard Wedge. User s Manual

TaoTronics Laser Barcode Scanner User s Manual

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

Product Reference Guide

Scanner Configuration Manager Manual. for PC type computers

Users Manual. QuickBarII Single-Chip Bar Code Decoder

Model 200 / 250 / 260 Programming Guide

Create!form Barcodes. User Guide

QuickScan Mobile. Reference Manual

URL encoding uses hex code prefixed by %. Quoted Printable encoding uses hex code prefixed by =.

Advanced Handheld High-Speed Laser Scanner

Introduction FCC Statement

MK D Imager Barcode Scanner Configuration Guide

ASCII Code. Numerous codes were invented, including Émile Baudot's code (known as Baudot

The ASCII Character Set

BARCODE IMAGER. Programming Manual International Edition, Rev. A1

MetroSelect. Single-Line Scanner. Configuration Guide

Configure Your FuzzyScan

METROLOGIC INSTRUMENTS, INC. IS4225 ScanGlove USB Addendum for the MetroSelect Single-Line Configuration Guide

MD6 Series 2D Barcode Scanner

CCD Programming Guide

USER'S GUIDE NUSCAN 2100 Series

QuickScan QS6500/QS6500BT

Table of Contents Appendix

Touch TD1100 Family General Purpose Corded Handheld Contact Imager Bar Code Reader

Product Reference Guide. QuickScan TM QS6500/QS6500BT. General Purpose Handheld Linear Imager Bar Code Reader with Bluetooth Wireless Technology

MS830 / MS833 Barcode Reader v1.0 9-December-2014

CHAPTER 8 BAR CODE CONTROL

Laser Scanner Programming Guide (SE923 laser engine)

QuickScan TM L QD 2300 Bar Code Scanner

NOTICE: respective owner. Note: Specification is subject to changes without. notice.

Synergy Controller Application Note 4 March 2012, Revision F Tidal Engineering Corporation Synergy Controller Bar Code Reader Applications

Barcode Scanner User Manual V6.6.2

User s Manual. Decoding Laser Scanner P/N

XR-500 [Receipt Printer User s Manual ]

MetroSelect Single Line Configuration Guide. MS9500 Voyager Series i

MS240/241 Programmable Magnetic Stripe Reader

Memory is implemented as an array of electronic switches

LS6300 Lecteur de code-barres laser

BAR CODE 39 ELFRING FONTS INC.

All brand, product and service, and trademark names are the property of their registered owners.

Magellan TM 3200VSi. On-Counter Vertical Presentation Scanner. Product Reference Guide

BCST-20 Barcode Scanner. Instruction Manual.

CT20 Barcode Scanner User Manual

VersaScan II. Barcode Scanner Quick Start Manual. ID TECH Walker Street Cypress, CA (714)

Using HyperTerminal with Agilent General Purpose Instruments

plc numbers Encoded values; BCD and ASCII Error detection; parity, gray code and checksums

MetroSelect Programming Guide. MLPN 2407/December 1998

BRMO 80 / ETH-IP. User Manual. Réf : MU-BRMO 80-ETH-IP-1.4-EN

Wireless Scanner. User s Manual - MS910 - Version 1.0

QuickScan TM Lite QW2100

Programming Reference Guide HP USB Barcode Scanner

Symbol LS9203. Product Reference Guide

TMCT-10 Barcode Scanner User Manual. 102, St. Edmonton, AB T6E 3N8 Ph Fax

Register your product and get support at DPM8500. Barcode scanner configuration guide

Command Emulator STAR Line Mode Command Specifications

SocketScan Software Advanced Programming Guide

Symbol LS1203. Product Reference Guide

QuickScan QS2500 Handheld Bar Code Scanner. Product Reference Guide

ESPA Nov 1984 PROPOSAL FOR SERIAL DATA INTERFACE FOR PAGING EQUIPMENT CONTENTS 1. INTRODUCTION 2. CHARACTER DESCRIPTION

How to Program a Windows 360 Keyboard?

QuickScan TM Lite QW2100

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

Transcription:

Table of Contents Introduction... 3 Installation... 4 Pin Assignments... 5 Method of Programming... 7 Interface selection... 10 Reading Mode...11 RS 232 Communication Parameters...12 Keyboard Wedge Parameters...14 Output Characters Parameters... 16 Wand Emulation... 17 OCIA Mode Parameters... 18 Bar Code Type Selection... 21 UPC/EAN/JAN... 24 Code 39... 26 Code 128... 28 Interleave 25... 30 Industrial 25... 32 Matrix 25... 34 CODABAR/NW7... 36 Code 93... 38 Code 11...... 40 MSI/PLESSEY... 42 BC 412... 44 China Postage... 46 Language Selection... 48 Bar Code ID... 50 1

Table of Contents Reading Level... 53 Accuracy... 53 Sensitivity of Continuous Reading Mode... 53 Buzzer Beep Tone... 54 PnP/Notebooks... 54 Reverse Output Characters... 54 Setup Deletion... 55 Setup Insertion... 59 Appendix A... 63 Appendix B...64 Appendix C...68 2

Introduction Thank you for selecting Birch barcode input product, CD- 108E CCD barcode reader. The reader is equipped with up to date optical technology. It auto-discriminates nearly twenty different kinds of barcode symbologies. Birch also provides other barcode related products to meet your application. The easily plug and play design of the keyboard wedge interface, provides a flexible solution to your application to explore the magic of the barcode system. This manual provides an easily method to modify the decoding options and interface protocols of the CD-108E by scanning the barcode in the manual. Before starting, please make sure that the barcode reader is properly powered. For PC keyboard emulation type interface, power is directly come from the system. For RS-232 or other non- PC keyboard emulation type interface, an external power is always needed. Codes Read ALL UPC/EAN/JAN, Code 39, Code 39 Full ASCII, Code 128, Interleave 25, Industrial 25, Matrix 25, CODABAR/NW7, Code 11, BC 412,MSI/PLESSEY, Code 93, China Postage, Code 32 3

Installation Installing the Keyboard Wedge Reader To install a keyboard wedge reader, follow the steps below: 1. Turn off the power of the PC or Terminal. 2. Unplug keyboard from the PC or Terminal. 3. Make sure you have the Y Cable with appropriate connector type for your PC or Terminal. 4. Connect Scanner to your PC or Terminal 5. Connect the keyboard connector to the female connector of the Y cable 6. Turn on the power of PC or Terminal. If the installation is successful, the Green LED light on the top of the reader should light up, and you should hear three beeps from reader. Installing the RS232 Reader To install a RS232 reader, follow the steps below : 1. Turn off the power of the PC or Terminal. 2. Make sure the connector type from RS232 to the PC or Terminal is correct. 3. Plug AC Adaptor connector into connector of the reader. 4. Turn on the power of PC or Terminal. 5. Setup the Interface of the reader to RS232 mode by scanning the barcode in the Interface Selection section. If the installation is successful, the Green LED light on the top of the reader should light up, and you should hear three beeps from reader. 4

1. Keyboard Output Pin Assignments DIN 5 MALE DIN 5 FEMALE Pin No. Function Pin No. Function 1 HOST CLK 1 KB CLK 2 HOST DATA 2 KB DATA 4 GND 4 GND 5 Vcc(+5V) 5 Vcc(+5V) 1 3 4 5 2 DIN 5 Male Pin Assignment 3 1 5 4 2 DIN 5 Female Pin Assignment MiniDIN 6 MALE MiniDIN 6 FEMALE Pin No. Function Pin No. Function 1 HOST DATA 1 KB DATA 3 GND 3 GND 4 Vcc 4 Vcc 5 HOST CLK 5 KB CLK 5 3 6 4 6 4 5 3 1 2 2 1 MiniDIN 6 Male Pin Assignment MiniDIN 6 Female Pin Assignment 5

Pin Assignments 2. RS-232 Output DB 9 Female Pin No. Function 2 TXD 3 RXD 5 GND 7 CTS 8 RTS Power Lead Vcc +5V 5 1 9 6 +5V GND DB 9 Female Pin Assignment Male DC Jack 3. WAND Emulation Output DB 9 Female Pin No. Function 2 DATA 7 GND 9 Vcc (+5V) 5 1 9 6 DB 9 Female Pin Assignment 6

Setup Flow Chart Method of Programming Start Configuration Recall Parameters Set All Defaults Interface Selection Input Port Selection Communication Parameters Bar Codes Parameters MSR Parameters Misc. Parameters etc. Abort Configuration End Configuration Save Parameters Loop of Programming The philosophy of programming parameters has been shown on the flow chart. Basically user should 1. Scan Start of Configuration. 2. Scan all necessary labels for parameters that meet applications. 3. Scan End of Configuration to end the programming. 4. To permanently save the settings you programmed, just scan label for Save Parameters. 5. To go back to the Default Settings, just scan label for Set All Defaults. 7

Factory Default Settings Method of Programming The factory default settings are shown with < > and bold in the following sections. You can make your own settings by following the procedures in this manual. If you want to save the settings permanently, you should scan the label of "Save Parameters" on page 9, otherwise the settings will not be saved after the decoder power is off, and all settings will go back to previous settings. By scanning "Set All Default" label, the settings will go back to the factory default settings. Download/Upload Settings This decoder offers an easy way to config all parameters from RS232 or PC keyboard interface. Just one click to download or upload confiuration data instead of scanning bar codes in this menu. Scan the Download/Upload bar code below to proceed downloading or uploading. Download/Upload %$ + / 7 8

Setup Commands Save Parameters Save the parameter settings permanently. %$ + / 0 Recall Stored Parameters Replace the current parameters by which you had saved last time. %$ + / 1 Set All Defaults Set all the parameters to the factory default settings. %$ + / 2 Start Configuration %$ + / 3 End Configuration %$ + / 4 Abort Configuration Terminate current programming status. %$ + / 6 Version Information Display the decoder version information and date code. %$ + / 5 9

Start Configuration Interface Selection Interface %0 0 U0 <Keyboard/USB Mode> %0 0 U8 RS232 Mode %0 0 M2 WAND Emulation %0 0 M4 OCIA Mode 10

Reading Mode End Configuration Reading Mode <Good Read OFF> %0271 Trigger ON/OFF %0270 Continuous/Trigger OFF %0272 Continuous/No Trigger %0273 Flash %0274 Testing %0275 Reserved1 %0276 Reserved2 %0277 11 Save Configuration

RS-232 Communication Start Configuration RS-232 Communication Parameters Set Up BAUD Rate %0 Y 7 0 600 %0 Y 7 1 1200 %0 Y 7 2 2400 %0 Y 7 3 4800 %0 Y 7 7 <9600> %0 Y 7 4 19200 Set Up Data Bits %0 Y 8 0 7 Data Bits <8 Data Bits> %0 Y 8 8 Set Up Stop Bits %0 Y O8 <1 Bit> %0 Y O0 2 Bits 12

RS-232 Communication End Configuration RS-232 Communication Parameters Set Up Parity <None> Even Odd Mark Space %0 Y N7 %0 Y N2 %0 Y N3 %0 Y N1 %0 Y N0 Handshaking RTS/CTS Enable <RTS/CTS Disable> ACK/NAK Enable <ACK/NAK Disable> XON/XOFF Enable <XON/XOFF Disable> %0188 %0180 %0144 %0140 %0 3 K 4 %0 3 K 0 13 Save Configuration

Keyboard Wedge Start Configuration Keyboard Wedge Parameters Terminal Type <IBM PC/AT, PS/2> %0ZF0 %0ZF1 %0ZF2 %0ZF3 %0ZF4 %0ZF5 IBM PC/XT IBM PS/2 25, 30 NEC 9800 ADB IBM 5550 IBM 122 Key (1) %0ZF6 %0ZF7 IBM 102 Key IBM 122 Key (2) %0ZF8 Reserved 1 %0ZF9 Reserved 2 %0ZFA Reserved 3 %0ZFB Reserved 4 %0ZFC Reserved 5 %0ZFD 14

Keyboard Wedge End Configuration Keyboard Wedge Parameters Upper/Lower Case <No Change> %0330 Upper Case %0331 Lower Case %0332 Send Character by ALT Method Enable %0 3 O8 <Disable> %0 3 O0 Select Numerical Pad ON %0 1 K 4 <OFF> %0 1 K 0 15 Save Configuration

Output Parameters Start Configuration Output Characters Parameters Select Terminator %7 S 2 + %7 S 7 + %7 S 0 + %7 S 1 + <CR+LF> None CR LF Space %7 S 4 + HT(TAB) %7 S 3 + STX-ETX %7 S 5 + Time-out Between Characters %0070 %0071 %0072 %0073 %0074 <0 ms> 5 ms 10 ms 25 ms 50 ms 16

Wand Emulation End Configuration Wand Emulation TTL Level Representation <Bar equals High> %0 2 K 4 Bar Equals Low %0 2 K 0 Scan Speed Selection <Fast> %0288 Slow %0280 Output Format Selection <Output as Code 39> %0 2 O8 Output as Code 39 Full ASCII %0 2 O0 17 Save Configuration

OCIA Mode Start Configuration OCIA Mode Parameters OCIA Mode Parameters <NCR 8 Bit Format> %0 2 J 0 NCR 9 Bit Fomat %0 2 J 1 Spectra-Physics %0 2 J 2 Nixdorf %0 2 J 3 18

UPC-A <ON> Symbology OFF End Configuration Bar Code Type Selection %0 A 4 4 %0 A 4 0 UPC-E <ON> OFF %0 B O8 %0 B O0 EAN-13/JAN-13 <ON> OFF %0 A 2 2 %0 A 2 0 EAN-8/JAN-8 <ON> OFF %0 A 1 1 %0 A 1 0 CODE 39 <ON> OFF %0 E O8 %0 E O0 19 Save Configuration

Symbology Start Configuration Bar Code Type Selection CODE 128 %0 F O8 %0 F O0 <ON> OFF CODABAR/NW7 %0 J O8 <ON> OFF %0 J O0 Interleave 25 %0 GO8 <ON> OFF %0 GO0 Industrial 25 %0 HO8 ON <OFF> %0 HO0 Matrix 25 %0 I O8 ON <OFF> %0 I O0 20

Symbology End Configuration Bar Code Type Selection CODE 93 ON <OFF> %0 K O8 %0 K O0 CODE 11 ON %0 L O8 <OFF> %0 L O0 China Postage ON %0 MO8 <OFF> %0 MO0 MSI/PLESSEY ON %0 NO8 <OFF> %0 NO0 21 Save Configuration

Symbology Start Configuration Bar Code Type Selection BC412 %0 OO8 ON <OFF> %0 OO0 Reserved1 %0 CO8 ON <OFF> %0 CO0 Reserved2 ON %0 DO8 <OFF> %0 DO0 Reserved3 %0 P O8 ON <OFF> %0 P O0 Reserved4 %0 QO8 %0 QO0 ON <OFF> 22

Symbology End Configuration Bar Code Type Selection Reserved5 ON %0 RO8 <OFF> %0 RO0 Reserved6 ON %0 S O8 <OFF> %0 S O0 Select All Bar Codes %1 A / + 23 Save Configuration

Symbology Start Configuration UPC/EAN/JAN Reading Type %0AK4 %0AK0 %0 B 8 8 %0 B 8 0 %0 B 4 4 %0 B 4 0 %0 1 O0 %0 1 O8 UPCA=EAN13 ON UPCA=EAN13<OFF> ISBN Enable ISBN <Disable> ISSN Enable ISSN <Disable> Decode with Supplementals <Autodiscriminate Supplementals> Supplementals Set Up <Not Transmit> %0 B 3 3 %0 B 3 1 Transmit 2 Code %0 B 3 2 Transmit 5 Code %0 B 3 0 24 Transmit 2&5 Code

Symbology End Configuration UPC/EAN/JAN Check Digit Transmission UPC-A Check Digit Transmission <ON> %0 A I 2 OFF %0 A I 0 UPC-E Check Digit Transmission <ON> %0 B I 2 OFF %0 B I 0 EAN-8 Check Digit Transmission <ON> %0 A 8 8 OFF %0 A 8 0 EAN-13 Check Digit Transmission <ON> %0 A H1 OFF %0 A H0 25 Save Configuration

Start Configuration Code 39 Symbology Type of Code <Standard> %0 E H1 %0 E H0 Full ASCII %0 E 8 0 Italian Pharmacy/Code 32<OFF> %0 E 8 8 Italian Pharmacy/ Code 32 ON Check Digit Transmission %0 E M2 %0 E M6 <Do Not Calculate Check Digit> Calculate Check Digit &Transmit %0 E M4 Calculate Check Digit & Not Transmit Output Start/Stop Character Enable %0 E 4 4 <Disable> %0 E 4 0 26

Symbology Code 39 End Configuration Set Up Code Length To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1-3 to set additional lengths. <Variable> %4 E 1 + Fix Length (2 Sets Available) 1st Set Begin (Then scan value in Appendix A) %4 E 0 0 1st Set Complete %4 E 0 1 2nd Set Begin (Then scan value in Appendix A) %4 E 0 0 2nd Set Complete %4 E 0 2 Minimum Length Begin(Then scan value in Appendix A) %2 + - / Complete %2 C0 + 27 Save Configuration

Start Configuration Code 128 Symbology Check Digit Transmission %0 F N1 Do Not Calculate Check Digit %0 F N7 Calculate Check Digit & Transmit %0 F N5 <Calculate Check Digit & Not Transmit> Append FNC2 ON %0 F 8 8 <OFF> %0 F 8 0 28

Symbology Code 128 End Configuration Set Up Code Length To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1-3 to set additional lengths. <Variable> %4 F 1 + Fix Length (2 Sets Available) 1st Set Begin (Then scan value in Appendix A) %4 F 0 0 1st Set Complete %4 F 0 1 2nd Set Begin (Then scan value in Appendix A) %4 F 0 0 2nd Set Complete %4 F 0 2 Minimum Length Begin(Then scan value in Appendix A) %2 + - / Complete %2 C1 + 29 Save Configuration

Symbology Start Configuration Interleave 25 Check Digit Transmission %0 GN3 <Do Not Calculate Check Digit> %0 GN7 Calculate Check Digit & Transmit %0 GN5 Calculate Check Digit & Not Transmit Set Up Number of Character <Even> %0 G8 8 %0 G8 0 Odd 30

Symbology End Configuration Interleave 25 Set Up Code Length To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1-3 to set additional lengths. <Variable> %4 G1 + Fix Length (2 Sets Available) 1st Set Begin (Then scan value in Appendix A) 1st Set Complete %4 G0 0 %4 G0 1 2nd Set Begin (Then scan value in Appendix A) %4 G0 0 2nd Set Complete %4 G0 2 Minimum Length Begin(Then scan value in Appendix A) Complete %2 + - / %2 C2 + 31 Save Configuration

Symbology Start Configuration Industrial 25 Check Digit Transmission %0 HN3 <Do Not Calculate Check Digit> %0 HN7 Calculate Check Digit & Transmit %0 HN5 Calculate Check Digit & Not Transmit 32

Symbology End Configuration Industrial 25 Set Up Code Length To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1-3 to set additional lengths. <Variable> %4 H1 + Fix Length (2 Sets Available) 1st Set Begin (Then scan value in Appendix A) %4 H0 0 1st Set Complete %4 H0 1 2nd Set Begin (Then scan value in Appendix A) %4 H0 0 2nd Set Complete %4 H0 2 Minimum Length Begin(Then scan value in Appendix A) %2 + - / Complete %2 C3 + 33 Save Configuration

Start Configuration Matrix 25 Symbology Check Digit Transmission %0 I N3 <Do Not Calculate Check Digit> %0 I N7 Calculate Check Digit & Transmit %0 I N5 Calculate Check Digit & Not Transmit 34

Symbology Matrix 25 End Configuration Set Up Code Length To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1-3 to set additional lengths. <Variable> %4 I 1 + Fix Length (2 Sets Available) 1st Set Begin (Then scan value in Appendix A) %4 I 0 0 1st Set Complete %4 I 0 1 2nd Set Begin (Then scan value in Appendix A) %4 I 0 0 2nd Set Complete %4 I 0 2 Minimum Length Begin(Then scan value in Appendix A) %2 + - / Complete %2 C4 + 35 Save Configuration

Symbology Start Configuration CODABAR/NW7 Set Up Start/Stop Characters Upon Transmission ON %0 J H1 %0 J H0 <OFF> Transmission Type of Start/Stop %0 4 V F <A/B/C/D> <Start> %0 4 F F <A/B/C/D> <Stop> A Start %0 4 V 1 %0 4 F 1 %0 4 V 2 %0 4 F 2 A Stop B Start B Stop C Start %0 4 V 4 %0 4 F 4 %0 4 V 8 %0 4 F 8 C Stop D Start D Stop 36

Symbology End Configuration CODABAR/NW7 Set Up Code Length To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1-3 to set additional lengths. <Variable> %4 J 1 + Fix Length (2 Sets Available) 1st Set Begin (Then scan value in Appendix A) %4 J 0 0 1st Set Complete %4 J 0 1 2nd Set Begin (Then scan value in Appendix A) %4 J 0 0 2nd Set Complete %4 J 0 2 Minimum Length Begin(Then scan value in Appendix A) %2 + - / Complete %2 C5 + 37 Save Configuration

Symbology Start Configuration Code 93 Check Digit Transmission %0 K N3 <Do Not Calculate Check Digit> %0 K N7 Calculate Check 1 Digit & Transmit %0 K N5 Calculate Check 1 Digit & Not Transmit %0 K N6 Calculate Check 2 Digits & Transmit %0 K N4 Calculate Check 2 Digits & Not Transmit 38

Symbology Code 93 End Configuration Set Up Code Length To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1-3 to set additional lengths. <Variable> %4 K 1 + Fix Length (2 Sets Available) 1st Set Begin (Then scan value in Appendix A) %4 K 0 0 1st Set Complete %4 K 0 1 2nd Set Begin (Then scan value in Appendix A) %4 K 0 0 2nd Set Complete %4 K 0 2 Minimum Length Begin(Then scan value in Appendix A) %2 + - / Complete %2 C6 + 39 Save Configuration

Start Configuration Code 11 Symbology Check Digit Transmission %0 L N3 <Do Not Calculate Check Digit> %0 L N7 Calculate Check 1 Digit & Transmit %0 L N5 Calculate Check 1 Digit & Not Transmit %0 L N6 Calculate Check 2 Digits & Transmit %0 L N4 Calculate Check 2 Digits & Not Transmit 40

Symbology Code 11 End Configuration Set Up Code Length To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1-3 to set additional lengths. <Variable> %4L1+ Fix Length (2 Sets Available) 1st Set Begin (Then scan value in Appendix A) %4L00 1st Set Complete %4L01 2nd Set Begin (Then scan value in Appendix A) %4L00 2nd Set Complete %4L02 Minimum Length Begin(Then scan value in Appendix A) %2 + - / Complete %2 C7 + 41 Save Configuration

Symbology Start Configuration MSI/PLESSEY Check Digit Transmission %0 NN3 <Do Not Calculate Check Digit> %0 NN7 Calculate Check Digit & Transmit %0 NN5 Calculate Check Digit & Not Transmit 42

Symbology End Configuration MSI/PLESSEY Set Up Code Length To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1-3 to set additional lengths. <Variable> %4 N1 + Fix Length (2 Sets Available) 1st Set Begin (Then scan value in Appendix A) %4 N0 0 1st Set Complete %4 N0 1 2nd Set Begin (Then scan value in Appendix A) %4 N0 0 2nd Set Complete %4 N0 2 Minimum Length Begin(Then scan value in Appendix A) %2 + - / Complete %2 C9 + 43 Save Configuration

Start Configuration BC 412 Symbology Check Digit Transmission %0 ON3 Do Not Calculate Check Digit %0 ON7 <Calculate Check Digit & Transmit> %0 ON5 Calculate Check Digit & Not Transmit 44

Symbology BC 412 End Configuration Set Up Code Length To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1-3 to set additional lengths. <Variable> %4 O1 + Fix Length (2 Sets Available) 1st Set Begin (Then scan value in Appendix A) %4 O0 0 1st Set Complete %4 O0 1 2nd Set Begin (Then scan value in Appendix A) %4 O0 0 2nd Set Complete %4 O0 2 Minimum Length Begin(Then scan value in Appendix A) %2 + - / Complete %2 CA + 45 Save Configuration

Symbology Start Configuration China Postage Check Digit Transmission %0 MN3 <Do Not Calculate Check Digit> %0 MN7 Calculate Check Digit & Transmit %0 MN5 Calculate Check Digit & Not Transmit 46

Symbology End Configuration China Postage Set Up Code Length To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1-3 to set additional lengths. <Variable> %4 M1 + Fix Length (2 Sets Available) 1st Set Begin (Then scan value in Appendix A) %4 M0 0 1st Set Complete %4 M0 1 2nd Set Begin (Then scan value in Appendix A) %4 M0 0 2nd Set Complete %4 M0 2 Minimum Length Begin(Then scan value in Appendix A) %2 + - / Complete %2 C8 + 47 Save Configuration

Operation Start Configuration Language Selection %0 Z V 0 <US English> %0 Z V 1 UK English %0 Z V 2 Italian %0 Z V 3 Spanish %0 Z V 4 French %0 Z V 5 Germany %0 Z V 6 Swedish %0 Z V 7 Swiss %0 Z V 8 Hungarian Japanese %0 Z V 9 48

Operation End Configuration Language Selection Belgium %0 Z V A Portugal %0 Z V B Demark %0 Z V C Holland %0 Z V D Reserved1 %0 Z V E Reserved2 %0 Z V F 49 Save Configuration

Start Configuration Bar Code ID Operation %0 0 H1 ON %0 0 H0 <OFF> Default %913+ With this function ON, a leading character will be added to the output string while scanning code, user may refer to the following table to know what kind of bar code is being scanned. Please refer to the table below for matching code ID of codes read in. Code Type ID Code Type ID UPC-A A UPC-E B EAN-8 C EAN-13 D CODE 39 E CODE 128 F Interleave 25 G Industrial 25 H Matrix 25 I Codabar/NW7 J CODE 93 K CODE 11 L China Postage M MSI/PLESSEY N BC412 O 1st Track X 2nd Track Y 3rd Track Z User Define Code ID To set the code ID: 1. Scan the symboligies label. 2. Go to the ASCII Tables in Appendix B, scan label that represents the desired code ID. Note: User define code ID will override default value. Program will not check the conflict. It is possible to have more than two symboligies which have same code ID. 50

Operation End Configuration Bar Code ID UPC-A UPC-E EAN-13/JAN-13 EAN-8/JAN-8 CODE 39 CODE 128 CODABAR/NW7 Interleave 25 Industrial 25 Matrix 25 CODE 93 CODE 11 China Postage %9 1 A + %9 1 B + %9 1 Y + %9 1 Z + %9 1 E + %9 1 F + %9 1 J + %9 1 G+ %9 1 H+ %9 1 I + %9 1 K + %91L+ %9 1 M+ 51 Save Configuration

Start Configuration Bar Code ID Operation %9 1 N+ MSI/PLESSEY %9 1 O+ BC412 %910+ Mag. Track1 Mag. Track2 %911+ Mag. Track3 %912+ %9 1 C+ Reserved1 %9 1 D+ Reserved2 %9 1 P + Reserved3 Reserved4 %9 1 Q+ Reserved5 %9 1 R+ %9 1 S + Reserved6 52

Operation End Configuration Misc. Parameters Reading Level Bar Equals High %0 3 I 2 <Bar Equals Low> %0 3 I 0 Accuracy <1 Time> %0130 2 Times %0131 3 Times %0132 4 Times %0133 Sensitivity of Continuous Reading Mode <Fast> %0388 Slow %0380 53 Save Configuration

Operation Start Configuration Misc. Parameters Buzzer Beep Tone %0 1 J 3 <High> %0 1 J 2 Medium %0 1 J 1 Low %0 1 J 0 Off PnP/Notebooks %0340 <Disable> %0344 Enable Reverse Output Characters %0 3 H0 <Disable> Enable %0 3 H1 54

Operation Setup Deletion End Configuration Setup Deletion To setup the deletion of output characters: 1. Scan the label of the desired set below. 2. Scan the label of the desired symboligy. 3. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the desired position to be deleted. 4. Scan the "Complete" label of "Character Position to be Deleted". 5. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the number of characters to be deleted. 6. Scan the "Complete" label of "Number of Characters to be Deleted". Repeat the steps 1-6 to set additional deletion. Select Deletion Set Number 1. 1st Set %800+ 2. 2nd Set %801+ 3. 3rd Set %802+ 4. 4th Set 5. 5th Set 6. 6th Set %803+ %804+ %805+ 55 Save Configuration

Operation Start Configuration Setup Deletion Symboligies Selection %8 1 A + UPC-A UPC-E %8 1 B + %8 1 Y + %8 1 Z + %8 1 E + %8 1 F + %8 1 J + EAN-13/JAN-13 EAN-8/JAN-8 CODE 39 CODE 128 CODABAR/NW7 Interleave 25 %8 1 G+ %8 1 H+ %8 1 I + Industrial 25 Matrix 25 CODE 93 %8 1 K + %81L+ CODE 11 56

Operation End Configuration Setup Deletion China Postage %8 1 M+ MSI/PLESSEY %8 1 N+ BC412 %8 1 O+ Resvered1 %8 1 C+ Resvered2 %8 1 D+ Resvered3 %8 1 P + Resvered4 %8 1 Q+ Resvered5 %8 1 R+ Resvered6 %8 1 S + None %814+ 57 Save Configuration

Start Configuration Setup Deletion Character Position to be Deleted Operation 1. Scan Decimal Value in Appendix A first. %820+ 2. Complete Number of Characters to be Deleted 1. Scan Decimal Value in Appendix A first. %830+ 2. Complete 58

Operation Setup Insertion End Configuration Setup Insertion To setup the insertion of output characters: 1. Scan the label of the desired set. 2. Scan the label of the desired symboligy. 3. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the desired position to be inserted. 4. Scan the "Complete" label of "Character Position to be Inserted". 5. Go to the ASCII Tables in Appendix B or Function Key Tables in Apendix C, scan label(s) that represents the desired characters to be inserted. 6. Scan the "Complete" label of "Characters to be Inserted". Repeat the steps 1-6 to set additional insertion. Select Insertion Set Number 1st Set %500+ 2nd Set %501+ 3rd Set %502+ 4th Set %503+ 5th Set %504+ 6th Set %505+ 59 Save Configuration

Operation Start Configuration Setup Insertion Symboligies Selection %5 1 A + UPC-A %5 1 B + UPC-E %5 1 Y + EAN-13/JAN-13 EAN-8/JAN-8 %5 1 Z + %5 1 E + %5 1 F + %5 1 J + CODE 39 CODE 128 CODABAR/NW7 Interleave 25 %5 1 G+ Industrial 25 %5 1 H+ Matrix 25 %5 1 I + CODE 93 %5 1 K + CODE 11 %51L+ 60

Operation End Configuration Setup Insertion China Postage %5 1 M+ MSI/PLESSEY %5 1 N+ BC412 %5 1 O+ Resvered1 %5 1 C+ Resvered2 %5 1 D+ Resvered3 %5 1 P + Resvered4 %5 1 Q+ Resvered5 %5 1 R+ Resvered6 %5 1 S + None %514+ 61 Save Configuration

Start Configuration Setup Insertion Character Position to be Inserted Operation 1. Scan Decimal Value in Appendix A first. %520+ 2. Complete Characters to be Inserted 1. Scan ASCII Table in Appendix B first. %530+ 2. Complete 62

Appendix A Decimal Value 0 1 2 3 4 5 6 7 8 9 63

Appendix B ASCll Tables NULL 00 ETX 03 ACK STX 02 ENQ 05 SOH 01 EOT 04 BEL BS 06 07 HT 08 LF VT 09 0A FF 0C SI 0B SO 0E CR 0D DLE DC2 DC1 0F 10 DC4 DC3 12 13 11 NAK 14 SYN ETB 15 16 CAN 17 EM SUB 18 19 ESC 1B RS 1A GS 1D FS 1C US 1E 1F 64

ASCll Tables Appendix B SPACE! 20 " 21 # $ 23 24 22 % & 25 ' 26 27 ) * 29 2A, - ( 28 + 2B 2C. 2D / 0 2F 30 2 31 3 32 33 5 34 6 35 36 8 37 9 38 39 ; 3A < 3B > 3D? 2E 1 4 7 : = 3C 3E 3F 65

Appendix B ASCll Tables @ A 40 41 C B 42 43 44 E D F 45 G 46 47 H I 48 J 49 4A K L 4C O 4B N 4E M 4D P 4F 50 Q R 51 S 52 53 T U 54 V W 55 56 X 57 Y 58 59 [ \ Z 5A 5B ^ 5E ] 5D 5C _ 5F 66

ASCll Tables Appendix B ` a 60 61 b c 62 d 63 64 e f 65 g 66 67 h i 68 j 69 6A k l 6C o 6B n 6E m 6D p 6F 70 q r 71 s 72 73 t u 74 v 75 76 w x 77 y 78 79 { z 7A 7B } 7C ~ DEL 7D 7E 7F 67

Appendix C Function Key Tables F1 F2 C0 C1 F4 F3 C2 F5 C3 F7 F6 C5 C4 F8 C6 F10 F9 C8 C7 F11 C9 Insert F12 CB CA Delete CC Page Up Home CE CD Page Down CF Left End D1 D0 Right D2 Up D3 Down D4 D5 68