thinkmotion EFFICIENCY FOR LIFE Advanced miniature motor design for medical ventilation

Similar documents
How to Optimize Performance and Minimize Size in High Speed Applications High Performance Brushless DC Motors

Brush DC Motor Basics. by Simon Pata Business Unit Manager, Brushless DC

The Emergence of Brushless DC Motors Within Medical Applications

BRUSHLESS DC MOTORS. BLDC 22mm. BLDC Gearmotor Size 9. nuvodisc 32BF. BLDC Gearmotor Size 5

Chen. Vibration Motor. Application note

Understanding the Alternator

Application Information Fully Integrated Hall Effect Motor Driver for Brushless DC Vibration Motor Applications

Application and Design of the ebooster from BorgWarner

Application Information

Simple Analysis for Brushless DC Motors Case Study: Razor Scooter Wheel Motor

Vehicle Design Summit Electric Hub Motor (V2) Eric Conner Harvey Tang Matthew Peddie

DIRECT CURRENT GENERATORS

Development Of High Efficiency Brushless DC Motor With New Manufacturing Method Of Stator For Compressors

CHAPTER 4 DESIGN OF INTEGRAL SLOT AND FRACTIONAL SLOT BRUSHLESS DC MOTOR

Synchronous motor. Type. Non-excited motors

Motor Fundamentals. DC Motor

Motors and Generators

Alternative Linear Motion Systems. Iron Core Linear Motors

Basics of Electricity

Electric Coolant Pumps. Always at the Correct Temperature

SYNCHRONOUS MACHINES

AC generator theory. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

DC Motor control Reversing

DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor.

Motor Selection and Sizing

Principles of Adjustable Frequency Drives

1150 hp motor design, electromagnetic and thermal analysis

KINETIC ENERGY RECOVERY SYSTEM BY MEANS OF FLYWHEEL ENERGY STORAGE

Torque motors. direct drive technology

Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc.

AC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles

8 Speed control of Induction Machines

Enhancing the Design of Electric Machines through the Interaction of Software Tools. Markus Anders Electric machine sector manager CD-adpaco

Single-Phase AC Synchronous Generator

Design and Testing of a Meso-Scale Pneumatic Actuated Electrical Power Generator

UNIT 3 AUTOMOBILE ELECTRICAL SYSTEMS

The DC Motor/Generator Commutation Mystery. Commutation and Brushes. DC Machine Basics

Specifying a Variable Frequency Drive s

Lab 8: DC generators: shunt, series, and compounded.

Borstlösa DC-motorer. Promoco Scandinavia AB

Airways Resistance and Airflow through the Tracheobronchial Tree

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

EC medium pressure axial fans. The effi cient system solution.

Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, HP

Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product.

Introduction to Linear Actuators: Precision Linear Motion Accomplished Easily and Economically

Fan Coil Units. Fan coil units with brushless DC motor with inverter. your comfort. our world. » Up to 70% energy saving with BLDC motor technology

AC Induction Motor Slip What It Is And How To Minimize It

Iron core Material-Somaloy Unique magnetic properties High purity iron powder Electrically insulated surface. Result in.

Why and How we Use Capacity Control

Chapter 22: Electric motors and electromagnetic induction

Lab 14: 3-phase alternator.

Turbo generators Best quality for thermal power plants

ELECTRICAL ENGINEERING Vol. III - Induction Motor and Self-Excited Induction Generator - Tze-Fun Chan

Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA

Inductance. Motors. Generators

PS-6.2 Explain the factors that determine potential and kinetic energy and the transformation of one to the other.

Selecting and Sizing Ball Screw Drives

Electric Rotary Actuator - On/Off or programmable control actuator

Introduction. Upon completion of Basics of AC Motors you should be able to:

Energy Savings through Electric-assist Turbocharger for Marine Diesel Engines

CNC Machine Control Unit

BLWR23MDA Series. 24V, 15A Brushless Controller / Motor. User s Guide. 910 East Orangefair Lane, Anaheim, CA info@anaheimautomation.

Stepper motor I/O. Application Note DK Motion Control. A General information on stepper motors

Motors and Inverters for Environmentally Friendly Industrial Equipment

hybrid stepper motors

13 ELECTRIC MOTORS Basic Relations

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

INSTRUMENTATION AND CONTROL TUTORIAL 2 ELECTRIC ACTUATORS

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

INTRODUCING RESMED S. Home NIV Solutions. S9 VPAP ST-A with ivaps S9 VPAP ST. Why choose average when you can choose intelligent?

A descriptive definition of valve actuators

FREQUENCY CONTROLLED AC MOTOR DRIVE

Tips For Selecting DC Motors For Your Mobile Robot

BRUSH DC motors. Brush DC 8mm. Motor Coil Cross Section. Brush DC 16mm. Brush DC 35mm

WHITE PAPER. DC Motors Explained. DC Motors Explained: White Paper, Title Page

Fundamentals of Inverter Fed Motors

Principles and Working of DC and AC machines

UNIT II Robots Drive Systems and End Effectors Part-A Questions

DRAIN PUMPS. Synchronous Drain Pumps DPS / DPO

INSTRUMENTATION AND CONTROL TUTORIAL 3 SIGNAL PROCESSORS AND RECEIVERS

Energy Saving ECM Motors and Fans Ventilation Catalogue

TECHNICAL INFORMATION Bulletin

TABLE OF CONTENTS INTRODUCTION...3 ADVANTAGES...5 OPERATION CHARACTERISTICS...6 EXCITATION TYPES...8 CONSTRUCTIVE COMPONENTS...9 ACCESSORIES...

Power Plant Electrical Distribution Systems

"AC2EC" - Replacement made easy New EC motor design Compact and efficient

THE LUCAS C40 DYNAMO & ITS ARMATURE.

1. The diagram below represents magnetic lines of force within a region of space.

MECHINICAL VENTILATION S. Kache, MD

For every breath he takes. Trilogy200 ventilator s added sensitivity lets you breathe easier knowing your patients are where they belong home.

INNOVATIVE ELECTROMAGNETIC SENSORS

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2

Rotating Machinery Diagnostics & Instrumentation Solutions for Maintenance That Matters

stainless steel pre-assembled manifolds

We will discuss common industrial applications with guides for the proper use of electric motors on these.

Electric Motor Brake Horsepower Calculations

AC Electric Motors best practice

LIMITED ANGLE TORQUE MOTORS AND TACHOMETERS

Equipment: Power Supply, DAI, Universal motor (8254), Electrodynamometer (8960), timing belt.

EFFECT OF OBSTRUCTION NEAR FAN INLET ON FAN HEAT SINK PERFORMANCE

Transcription:

thinkmotion EFFICIENCY FOR LIFE Advanced miniature motor design for medical ventilation The roots of positive airways mechanical ventilation can be traced to WWII with the needs for pilots to breath at higher altitudes. Ventilation therapy then made accelerated progresses during the polio epidemic in the 50 s. Today, mechanical ventilation is indicated when a patient's spontaneous ventilation is inadequate to maintain life. It is also indicated as prevention for imminent collapse of other physiologic functions, or ineffective gas exchange in the lungs. Mechanical ventilation in hospitals and in the field have contributed to dramatically improve the life expectancy of patients during and after surgeries, or suffering from accidental disrupted lungs function or finally of patients suffering from acute chronic pulmonary diseases. More recently home care applications previously considered as comfort-improving therapies are showing premier medical interest in the race to extend people s life. For instance, lower end mechanical ventilators devices known as CPAP and used at night to treat sleep apnea, a disorder once considered a simple discomfort and which is now recognized as a source of major medical complications (increased blood pressure, diabetes, ) ; are increasingly popular and effective. Medical ventilation technology has been evolving from stationary units originally relying on oxygen and compressed air drawn from the hospital supply lines into autonomous portable devices, capable of providing their own controlled pressure and flow. This migration was accelerated with the increased need to allow patients to recover in the comfort of their own home after a pulmonary surgery when affected from acute Obstructive Sleep Apnoea (OSA) syndrome or even from more severe conditions such as acute respiratory failure or Chronic Obstructive Pulmonary Diseases (COPD), a growing leading cause of death globally. Consequently former valves or piston driven solutions progressively gave way to high-speed micro-turbine blower driven ventilators, which can now be distinguished in 4 major categories: intensive care, home care, transport ventilators and neonatal ventilators.

Miniature Motors for High Efficiency Blower Systems High efficiency blower systems which include a specific motor and a fan have been designed in such a way that inspiration pressure (IPAP) and expiration (EPAP) pressure can be generated and controlled by acting on the motor speed only (cf. fig. 1). By ramping up and down motor speed from 15,000 to 60,000 rpm in a matter of 100-120 milliseconds, the newest ventilators are capable of ventilating modes very close to a patient s natural breathing pattern, hence maximizing their therapy acceptance, and are also capable of invasive Fig. 1: Typical medical ventilator set-up ventilation, once not possible with turbine blower designs. Pressure of 100 CmH2O and flow in excess of 200L/min are now common requirements which Portescap brushless-motor-equipped blowers can reliably support. Indeed, brushless technology offers the longer life span at such speed. Collaborative work with ball bearing manufacturers warrant the best solution for each application requirement (speed, load, oxygen content, noise level,..). Because of the increased demand in ambulatory ventilation solutions mentioned above, longer battery life, and thus the need for a higher efficiency motor, is critical. UNDERSTANDING MOTOR EFFICIENCY To understand motor efficiency, let s review some of the losses that can be generated by a motor under load: Eddy current losses and Joules losses. Indeed both losses sources, if not minimized, contribute directly to poor battery life, as well to motor temperature raise which adversely affect bearing life and other ventilator internal components temperature. The later often leading to the use of cooling fans, vents which contribute to higher ventilator noise level and increased cost. Joule losses: These are equal to I².R where R is the motor resistance and I the current consumed. Hence, an efficient motor under constant load will consume little current to perform a task, while a less efficient motor will consume a lot of current to perform the same task and as a result will heat up more.

Thanks to their specific coil design and optimized magnetic circuits, Portescap slotless brushless motors are particularly current frugal which allow to size down batteries and power supplies and further enhance the portability of ventilators. Additionally, as explained previously, patient s therapy acceptance has driven motors to ever be more responsive to ventilators command to ramp up and down in speed. This affects how motors draw current during these dynamic phases in relation with the inertias of the various components and the acceleration rate. Let s consider: Ji: inertia of the fan impeller. Jm: inertia of the motor rotor. α : the desired acceleration The Torque T required to accelerate these inertias is: T = (Ji+Jm).α (1) Now let s consider: K: motor torque constant (ability for a motor to create torque given a current) I, the current drawn under acceleration becomes: I=T/k Consequently, combined with equation (1), I current drawn under acceleration becomes: I=(Ji+Jm).α/K It then becomes obvious that optimizing the system inertia is critical for managing the thermal losses in acceleration phases since, as previously seen, these are proportional to the square of the current drawn (I².R). The ability to choose magnet grade, strength and dimension to optimize the final solutions is critical in that respect. Ventilators requiring high Breadth Per Minute and lower delivered pressure & volume such as neonatal applications will most likely dictate the selection of smaller inertia motor to minimize losses during the acceleration phases and allow up to 90 BPM. In contrast, a full adult life-support ventilator with both

higher delivered pressure and larger volume, but fewer BPM most likely will require a more powerful motor. Eddy current losses: are the other major generated losses in a running motor. These losses occur while rotating a magnetic field in front of a piece of iron and generate heat. This phenomenon is exactly what happens inside a motor when its rotor magnet spins at high velocity in front of its stator laminations. Eddy current losses are proportional to the square of the frequency. With the increased requirement in pressure and flow of modern ventilators, thus in motor rotational speed, it is important to consider this while designing the best motor for each ventilation application. The number of rotor magnet pole-pairs is equally important as its rotational speed. As an example, Portescap brushless motors have been optimized with 1 pole pair, thus dividing by 4 the amount of Eddy current losses typically generated by 2 pole-pair motors. Lamination material and thickness selection is also an important step in the design of the best motor as they both dramatically affect losses generated at high speed. Low core-loss steel lamination material and thinner lamination can reduce operating temperature of motors, but they can rapidly affect its cost as well. Brushless Motors The Slotless Coil Technology Slotless motor self-sustaining coil technology offers the added benefit of not requiring to be hosted by the lamination. Indeed, typical slotted brushless motors stator coils are wound around the laminations teeth created by their profile (cf. fig 2 below). The benefit of the slotless motor design is that it does not introduce iron in the air gap (area between magnet and copper wire) which further reduces iron losses. This design also yields a smoother rotation as the magnet is not attracted in any preferred position created by the stator teeth. Vibration and noise level are typically greatly reduced as a result. coil magnet laminations Fig. 2: Slotted versus Slotless brushless motor section

Consequently, both reduced these residual losses (Eddy & Joules) in some available miniature motors allow operating temperatures to decrease by as much as 25% under the same ventilation requirements (pressure, flow, BPM,..) than with previous generation motors. Length is another factor to consider when selecting a motor. Indeed, a longer motor while increasing k (torque constant) thus reducing the current needed under a same load as for a shorter motor, also has the benefit of better dissipating the temperature generated by its losses. Although Eddy current losses also increase with the amount lamination material and inertia is also marginally negatively affected as motor length grows (as opposed to greatly affected when its diameter grows). Miniature Motor Selection Considerations In conclusion, the selection of the best ventilator motor comes down to a balancing act of application requirements. ICU ventilators, typically larger in size, can accommodate a full length 22mm slotless BLDC motor for its ability to continuously deliver full pressure and speed, maximize reliability with best thermal management, and where cost is not as sensitive as in home care solutions. Home care and transport ventilators designers typically favour a medium length 22mm motor for its compactness, efficiency for longer battery life, reliability in ambulatory application, more modest cost and the flexibility it offers in providing temporary high pressure & flow or high dynamics. Dedicated neonatal ventilators, usually running smaller fan impeller will best be designed with lower inertia motors such as Portescap 16 mm solution allowing for high speed and acceleration and repeated step function cycles. Finally, motor and blower integration is key for the best overall flow generation function. Motor mechanical features such as shaft, front flange and more need to be customizable to accommodate for best union of components. About Portescap Interested in learning more about how Portescap can help optimize a motion solution for your medical application? Contact us today. Additionally, our expertise in assembled impeller balancing, laser and ultrasonic welding capabilities allows Portescap to deliver complete pressure and flow tested blower assemblies to OEMs.

Portescap offers miniature motor technologies to solve the motion needs of a spectrum of end markets, from medical devices to various industrial applications, that save, improve and enhance lives. We serve our customers through breadth of innovative product technologies encompassing Brushless DC, Brush DC, Can Stack motors, Disc Magnet motors and Stepper Linear actuators to optimize application performance. Our products deliver motion in a compact package with high efficiency and low power consumption. Loic Lachenal Bruno Fauvel Portescap www.portescap.com