Powerful Backup to Identification of Fatty Acid Methyl Esters

Similar documents
C146-E087F. GCMS-QP2010 Plus. Shimadzu Gas Chromatograph Mass Spectrometer

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

Pesticide Analysis by Mass Spectrometry

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Analyzing Small Molecules by EI and GC-MS. July 2014

Background Information

Analysis of Phthalate Esters in Children's Toys Using GC-MS

The Use of Hydrogen Carrier Gas for GC/MS

Expectations for GC-MS Lab

Bringing Innovations to Standards AC Analytical Controls by PAC All In One Biodiesel Analyzer

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

SCREENING FOR THE PRESENCE OF PARA-METHYLTHIOAMPHETAMINE IN URINE BY SOME COMMERCIAL IMMUNOASSAYS AND CONFIRMATION BY GC/MS

Storage Conditions of Sausages

SCION SQ Series GC-MS

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS

Electrospray Ion Trap Mass Spectrometry. Introduction

AMD Analysis & Technology AG

Waters Core Chromatography Training (2 Days)

Setting up a Quantitative Analysis MS ChemStation

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

MASS SPECTROMETRIC IDENTIFICATION OF SOME SULPHUR CONTAINING PHENALKYLAMINE DESIGNER DRUGS *

ForensicDB: A Web-accessible Spectral Database

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Theory and Instrumentation of GC Introduction

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

23 The Thermal Conductivity Detector

New drugs of abuse? A case study on Phenazepam & Methoxetamine

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Addressing the World Helium Shortage For Gas Chromatography

Infrared Spectroscopy 紅 外 線 光 譜 儀

RAPID MARKER IDENTIFICATION AND CHARACTERISATION OF ESSENTIAL OILS USING A CHEMOMETRIC APROACH

ALLERGENS IN PERFUMES: GAS CHROMATOGRAPHY^ MASS SPECTROMETRY

Retention Parameters in Column Chromatography

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Gas Chromatography Liner Selection Guide

Quantitative Evaluation of Perfume Fleuressence Samples using the znose

Opiates in Urine by SAMHSA GC/MS

Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) (PCS# RFQ)

Application Note # MS-14 Fast On-site Identification of Drugs with the mobile GC/MS system E²M

The First Quantitative Analysis of Alkylated PAH and PASH by GCxGC/MS and its Implications on Weathering Studies

Multi-Shot Pyrolyzer EGA/PY-3030D. Flexible Versatile Reproducible

13C NMR Spectroscopy

CHROMOCTANE O N LINE ANALYZER

Appendix 5 Overview of requirements in English

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

Application of TargetView software within the food industry - the identi cation of pyrazine compounds in potato crisps

How To Use Gc-Ms

GUIDELINES ON THE USE OF MASS SPECTROMETRY (MS) FOR IDENTIFICATION, CONFIRMATION AND QUANTITATIVE DETERMINATION OF RESIDUES CAC/GL

Using NIST Search with Agilent MassHunter Qualitative Analysis Software James Little, Eastman Chemical Company Sept 20, 2012.

How To Analyze Pesticide Levels In Lemon Oil

Application of Structure-Based LC/MS Database Management for Forensic Analysis

Analysis of Liquid Samples on the Agilent GC-MS

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

MassHunter for Agilent GC/MS & GC/MS/MS

GCxGC COUPLED TO FAST SCANNING QUADRUPOLE MS FOR TRACE ANALYSIS OF POPs

Advantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

AC DHA Solutions. Detailed Hydrocarbon Analysis of Light Petroleum Streams & Light End in Crude Oils. ASTM D 5134, D 6729, D 6730, D 6733 Compliance

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

CLEAN-UP PROCESS FOR MASS SPECTRAL STUDY OF AMPHETAMINES IN PUTREFIED BODY MATERIALS

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

The author(s) shown below used Federal funds provided by the U.S. Department of Justice and prepared the following final report:

WHITE PAPER CONTINUOUS AIR MONITORING USING GRIFFIN 460 MOBILE GC/MS. HEADINGS: ALL CAPS, 12 PT TREBUCHET FONT, ICx BLUE

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

m/z

QGA Quantitative Gas Analyser

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

Xcalibur Versions

Fast Continuous Online Analysis of VOCs in Ambient Air using Agilent 5975T LTM GC/MSD and Markes TD

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

Identification of Surfactants by Liquid Chromatography-Mass Spectrometry

How To Build An Amd Quas 3 Ar Mass Spectrometer

Application of TargetView software in the fragrance industry: Accurate identi cation of allergens with fast GC

STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Separation of Amino Acids by Paper Chromatography

is a knowledge based expert decision support tool for predicting the metabolic fate of chemicals in mammals.

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

Alignment and Preprocessing for Data Analysis

Quantitative Analysis of Stable Isotopes of Glucose in Blood Plasma Using Quadrupole GC-MS GC/MS Technical Report No.2

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Discovery of Pesticide Protomers Using Routine Ion Mobility Screening

Chemical analysis service, Turner s Green Technology Group

Mass Spec - Fragmentation

HOMEWORK PROBLEMS: IR SPECTROSCOPY AND 13C NMR. The peak at 1720 indicates a C=O bond (carbonyl). One possibility is acetone:

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

MS/MS analysis of Polyphenols

Chemical Profiling and Differential Analysis of Whiskies Using Orbitrap GC-MS

Diffusion and Fluid Flow

FORENSIC TOXICOLOGY LABORATORY OFFICE OF CHIEF MEDICAL EXAMINER CITY OF NEW YORK. VOLATILES ANALYSIS by GCMS HEADSPACE ANALYSIS

Transcription:

FAMEs GC/MS Library Fatty Acid Methyl Esters Library ver 1.0 For Shimadzu GCMS-QP2010 Series Powerful Backup to Identification of Fatty Acid Methyl Esters 240 Compounds: Mass Spectra and Retention Indices Contained in Special Library Through Linking with Similarity Search with Retention Index supported by GCMSsolution Highly Reliable and Efficient Identification is Achieved for Fatty Acid Methyl Esters Similarity Search with Retention Index The retention index is calculated automatically by GCMSsolution. Similarity search with retention index enables greater reliability of search results by matching retention indices with those of compounds contained within the mass spectral libraries. Unequivocal Identification for Compounds with Similar Mass Spectra such as Isomers and Homologs.

FAMEs GC-MS Library Mass spectrometry is an analytical technique, useful to identify unknown compounds; however, to increase the power of such an instrument, large mass spectra databases are needed to match the ion fragmentation of the unknown compound. Often dedicated libraries could be much more useful, in particular for specific fields of research (e.g., industrial, academic, pharmaceutics, etc.) or samples. Fatty acids are very important compounds since they are sample specific. They can be used as markers or their profile can be used as a fingerprint (e.g., bacteria fatty acids) or to reveal fraud (e.g., seed oil added to olive oil) In GC, fatty acids are analyzed after derivatization to methyl esters; thus, a library of 240 fatty acid methyl esters (FAMEs) has been built. The library was obtained under the conditions shown in Table 1. Table 1. Instrument conditions Gas Chromatograph Automatic sampler Inlet Columns Carrier gas Oven program temperature GCMS-QP-2010-Plus AOC-201 split/splitless injector SLB-5MS 30 m x 0.25 mm x 0.25 µm (Supelco) Supelcowax 30 m x 0.25 mm x 0.25 µm (Supelco) Helium in constant linear velocity mode (35 cm/s) 50 C to 350 (280) at 3 C/min Mass Spectrometer QP-2010-Plus Ion source temperature 220 C Interface Temperature 350 C Scan range 50-550 uma Electron Impact (EI) 70 ev

The database contains linear retention index data, registered using an alkane mixture on an apolar column and using also a FAMEs and a FAEEs (fatty acid ethyl esters) mixture on a polar one. The library match is not enough for reliable identification of unknown compounds, since ion fragmentation patterns can be similar for several compounds. Therefore another filter is needed! Linear retention index (LRI) values are the most suitable choice, since they do not depend on linear velocity, column length, and temperature program. 100 x n + t R(x) t R(z) t R(z+1) t R(x) Figure 1.Example of mass spectrum similarity of different FAMEs, which can be reliably identified only considering the LRI 1.0 (x10,000) 74 0.5 43 57 143 97 0.0 115 129 157 171 185 213 227 239 270 50.0 75.0 100.0 125.0 150.0 175.0 200.0 225.0 250.0 275.0 300.0 325.0 350.0 1.0 (x10,000) 74 Automatic search using two filters: 1- similarity 2- LRI agreement ic16:0 93% LRI: 1888 0.5 43 69 97 143 111 129 227 0.0 157 171 185 213 241 270 50.0 75.0 100.0 125.0 150.0 175.0 200.0 225.0 250.0 275.0 300.0 325.0 350.0 1.0 (x10,000) 74 C16:0 00 93% LRI: 1925 ac16:0 93% LRI: 1894 0.5 43 57 143 97 115 129 0.0 171 185 199 213 227 270 50.0 75.0 100.0 125.0 150.0 175.0 200.0 225.0 250.0 275.0 300.0 325.0 350.0

How to use the LRI filter: 1- Inject an alkanes (FAMEs or FAEEs) mixture, register the name of each peak with the relative LRI on the compound table, and save the file. Name and LRI 2- Inject your sample and upload the file created in point 1 in the retention index page of the qualitative parameter window

3- Set the parameters of the similarity match and LRI allowance FAMEs profile of a bacteria sample (Pseudomonas aeruginosa) 4- Now you are ready to identify an unknown sample!

Set the filters parameters (minimal similarity and LRI allowance) Only one candidate!! The retention index allowance windows and the tolerance range have been calculated by means of multiple injections of compounds for testing the repeatability. Due to the low solubility of n-alkanes in the polar stationary phase, FAMEs and FAEEs standard mixtures have been used to calculate LRIs on the Supelcowax-10 column. In table are reported LRI repeatability data (expressed as difference between the LRIs), calculated for a series of randomly-selected compounds.

The use of the double filter is suitable also for comprehensive GC! Standard of bacteria FAMEs 3-OH-C14:0 3-OH-C12:0 2-OH-C16:0 2-OH-C14:0 2-OH-C12:0 c-c18:1 2-OH-C10:0 C16:1 c9,10-c17:0 C18:2 c9,10-c19:0 C20:0 i-c16:0 C18:0 C12:0 C13:0 C14:0 C15:0 C16:0 i-c17:0 C17:0 tr-c18:1 C19:0 C11:0 i-c15:0 a-c15:0 LRI:1929-10 +10

Chromaleont is a Society that offers solutions for the development of analytical instrumentation and dedicated software for chemical analysis and consulting in the field of Separation Science. The scope is therefore the development of new analytical methodologies for the analysis of complex mixtures by using innovative analytical instrumentation. Chromaleont spin-off with the University of Messina has its office at The Mediterranean Separation Science Foundation Research and Training Center guest in the Dipartimento Farmacochimico of the School of Pharmacy of the University of Messina. For information about Chromaleont, please visit our Web site at www.chromaleont.it To contact us: chromaleont@chromaleont.it Retention Index Search - Greater Assurance and Efficiency of Identification - Target Spectrum Retention Index Automatic Calculation Retention Index : 1057 Until Now: Similarity Search Similarity 80 or more Many hits, but Identification is difficult FAMEs GC/MS Library : Similarity Search + Retention Index Search Conventional library search, making use of solely spectral similarity, often indicates so many probable candidates for an unknown that it is hard to identify it, especially in the case that sample includes isomers and much matrix. GCMSsolution provides similarity search with retention index, using retention indices registered in FAMEs GC/MS Library. This function makes it possible to perform more reliable and easier search even for complex samples. The results can be output as reports in electronic or hardcopy. *FAMEs GC/MS Library can be used for GCMSsolution Ver 2.4 or higher. Similarity 80 or more + Retention Index calculated against FAEEs: Tolerance Range : ± 10 Identification Is Easy! Key contents Each record contains the mass spectrum, searchable structure, chemical information, and LRI retention data Records indexed by name, molecular weight, and retention time Highly controlled: Measured on a single instrument in controlled conditions Quality samples sourced from leading suppliers and manufacturers Also available in five manufacturer formats for use with most common mass spectrometry applications: (1) NIST MS Search, (2) Agilent Chemstation, (3) PerkinElmer TurboMass, (4) ThermoFisher Spectral ID, (5) Waters MassLynx. For more info visit the site: http://www.wiley.com