Confidence with the global standard in pressure relief devices

Similar documents
BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

PRESSURE REDUCING CONTROL VALVE

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

400 Series - Mini USB Buccaneer

Morrison Bros. Co. General Product Specifications

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

Flow switches Series AD/VH

Baumann Flexsleev Sanitary Control Valve

Baumann Way Bronze or Stainless Steel Control Valve

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Baumann Mikroseal Control Valve

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

Scraper Passage Indicator. Electrical Indicator. Features

WE-350 Series ¼ Turn Electric Actuator

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Mini USB and USB 2.0-IP67 Connector System

Midwest Industrial Tanks

Horizontal Jet Pumps 1/3-1-1/2 HP

FLANGED END BALL VALVE

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

RUBBER SLEEVE KNIFE GATE VALVE

1800C and 1800C-HC Series Service Regulators. Technical Bulletin

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

V47 Series Temperature Actuated Modulating Water Valves

SQUARE D INDUSTRIAL CONTROL PRODUCTS

Fisher 657 and 667 Diaphragm Actuators

Electronic Flow Switches

167D Series Switching Valves

System 8. ü ( System 8

In-Line Electronic Flow Switches

Plastic Injection Molding

08.08 Vic-Check Valves

Sanitary Type Electronic Flow Switches

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Standard Buccaneer - USB

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Single sub-base valve

Micro Motion Model D and DL Coriolis Flow and Density Meters

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Ultipleat High Flow Filter System

RE-ENTERABLE SPLICE CLOSURE KITS. (For Air Core None Pressurized Cable)

B-Series Temperature Switches

Compact pressure switch Flameproof enclosure Ex d Model PCA

SECTION GUARDA SECURITY WINDOW SCREENS

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

4 Posiflow Proportional Solenoid Valves

Tyco PremiAir Pneumatic Actuators

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

STB Series Enclosures

REGULATORS 175/153 Series

The Wild Children of D38999

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

SELECTION, APPLICATION AND MAINTENANCE

HOPPER SHAPE KNIFE GATE VALVE

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

Worcester DS/DM Series UltraSwitch Switch box

Butterfly Valves PN 6/10/16 for flanged connection

PAM Connectors. PAM Bayonet Connectors

In-Line Electronic Flow Switches

Industrial Generator Set Accessories

SlimSeal SSL Connector. Now Available in 1 Position. Free Hanging Version

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

ROUGHNECK II Pumpless Drain

1805 Series Relief Valves

Industrial Generator Set Accessories

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

Analogue + IVS Electronic Throttle Controls for CUMMINS Engines

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDS1 Swing Gate Valve. by AMOT. Overview. Typical Applications. Key Features and Benefits

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Hose Clamps & Fittings

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

AMP Standard Terminals and Splices. RoHS. Ready

Heat Tracing is the use of an externally applied heat source to a pipeline to compensate for heat losses through the thermal insulation.

Spare Parts Program. Parts, Consumables & Accessories superproductsllc.com


LED LEONARDO 120 W. LED Fresnel SPOTLIGHT White light, either Tungsten or Daylight balanced Correlated Color Temperature

MODEL 9020 & 9020-OEM CORRATER TRANSMITTER USER MANUAL

Vacuum drying oven for non-flammable solvents

How To Use A Ds340 (Dsp)

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Diaphragm Actuators Favorable Variety Pneumatic Diaphragm Actuators Electric Actuators Hydraulic Actuators

3/2-way Solenoid Valve, direct-acting, NC or NO

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

Solenoid valves 2/2-way direct-operated Type EV210A

Section: R100 Bulletin: R Date: 07/13 Supersedes: New TRUST. Your Water Level. Steam you can depend on, 24/7. Boiler Level Indication System

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

PRODUCT SPECIFICATION

Encoder WDGI 58H.

TARIFF CODE and updates standard

Transcription:

QUALITROL LPRD Large pressure relief devices Confidence with the global standard in pressure relief devices Robust design and materials provide reliable protection and long life Widest array of options for a solution curtailed to your requirements 100% tested for quality assurance Visual and remote indication of operation Product Summary Description Mechanical device for relief of excessive pressure buildup in large volumes of gas or fluid. Patented dual gasket system provides quick response time and automatically reseals after pressure has subsided. Options include local operation indication, contacts (switches) for operation alarming, and directional shield for hot oil and gas exhaust control. Application For overpressure protection on transformers, load tap changers and other related electrical equipment.

QUALITROL LPRD large pressure relief devices ` Confidence with the global standard World s leading pressure relief device pioneered automatically in pressure relief devices resealing pressure relief Greater than 50 years and 400,000 units of field experience in pressure relief have enabled QUALITROL experts to refine designs for maximum reliability Most frequently customer specified pressure relief by name ` Robust design and materials provide Main cover is available in zinc clad steel (208/213) or stainless steel (216) reliable protection and long life for added durability and corrosion resistance Dual gasket design provides amplified force for rapid operation Patented secondary seal wiper gasket provides more reliable resealing Stainless steel operating valve, fasteners, and hardware for added durability Flange and ring are made from aluminum with a chromate conversion coating with exposed aluminum components receiving an additional thermosetting powder coat finish Widest array of options for a solution curtailed to your requirements Preset certified relief rating allows you to select the device that best meets your needs Switches can be specified to operate as latching or momentary, SPDT or DPDT, high DC, or low current gold contact type, and with connector, terminal box, or flying lead style connections Optional directional shield can be coupled with piping, providing maximum protection of equipment, personnel and the environment by redirecting the flow of hot oil and gas Optional gas bleed system available for mounting under the oil level Device can be top mounted horizontally (recommended) or side mounted vertically for maximum installation flexibility 100% tested for quality assurance QUALITROL LPRDs are 100% pressure tested for proper operation pressure Test results are serialized for traceability Visual and remote indication of operation Optional semaphore (flag) provides visual indication of actuation and is available in different colors and materials Standard units support up to two alarms switches that can be mounted directly to the device or on the directional shield? Don t see what you need? QUALITROL regularly creates models with special customer requirements. Contact your local sales representative or QUALITROL Application Engineer to review your special requirements.

LPRD features OPTIONAL SEMAPHORE ALARM SWITCH INDICATOR PIN COVER ELECTRICAL CONNECTION (QUALITROL Quick disconnect shown) FLANGE Applications Qualitrol Pressure Relief Devices are used in a wide variety of transformer systems including: Network (up to 500 KVA and higher in certain applications) Large distribution and small power (up to 2500 KVA) Medium power (2500 KVA to 10,000 KVA) Large power (10,000 KVA and above) Load tap changers Mobile systems Electric railway locomotives Installation While no precise formula applies to determine the required quantity of pressure relief devices (PRDs) for protection, it is typical to apply the following general rule: Use one pressure relief device for each 10,000 gallons of cooling liquid capacity or fraction thereof. Some specifications require the use of pressure relief devices on transformers rated at 1,000 KVA or higher but many QUALITROL LPRDs are in use on transformers rated as low as 300 KVA. Ultimately, the choice of the size and quantity of PRDs to install comes down to the risk level an operator is willing to operate at. QUALITROL LPRDs are typically mounted in the recommended horizontal orientation with the top side up, however, they may be side mounted (vertical orientation) as well. In these installations, when the device is mounted below the fluid level, the normal head pressure must be considered when determining the operating value of the LPRD. In addition, provision should be made for proper clearance of the operation indicator, and optimal orientation of the electrical connection.

` Components and accessories Alarm switches Each pressure relief device can be specified with up to two alarm switches (with 4 contacts) that will activate upon valve operation Switch contacts can be specified as latching or momentary operation, SPDT or DPDT, high DC, or low current gold contact type, and with connector, terminal box, or flying lead style connections Directional shield Directional shield mounts on top of pressure relief device and is specifically designed for ease of retrofit applications Redirects flow of hot oil and gas away from personnel or critical parts on the transformer Shield accommodates up to two alarm switches and an indicator Operation indication semaphore Optional semaphore (flag) provides visual indication of actuation and is available in different colors and materials Compatible with directional shield and alarm switches Gas bleed system For use in applications where pressure relief device is mounted below the oil level Provides a means by which trapped gases can be purged from the wetted chamber of the pressure relief device BLEED SCREW Email info@qualitrolcorp.com www.qualitrolcorp.com

QUALITROL LPRD large pressure relief devices TECHNICAL SPECIFICATIONS Materials Cover Cold rolled steel, zinc plated with chromate and thermosetting powder coat or 300 series stainless steel, as per model Flange Ring Indicator pin Indicator retaining sleeve Bushing Spring Spring seat Valve stems External hardware Sealing valve Springs Studs Gaskets Semaphore (optional) Die cast aluminum; polyester resin impregnated, chromate conversion coating and ASA 70 light gray thermosetting powder coat finish Aluminum with chromate conversion coating Brass UV stabilized nylon and high temperature thermoplastic rubber Stainless steel ASTM A229 oil-tempered spring wire with zinc plate and chromate Aluminum Carbon steel with zinc plate and chromate Stainless steel 304 Stainless steel, sealing areas lubricated with silicone based lubricant ASTM A229 Oil tempered spring wire 416 stainless steel, or 300 series stainless steel, as per model Nitrile, Viton, or Silicone as per model Impact resistant plastic with stainless steel hardware is standard Environmental Ambient operating -40 F to +176 F (-40 C to +80 C) temperature Oil operating temperature Salt spray -4 F to +212 F (-20 C to +100 C) 200 hours of salt spray testing per ASTM B:117 with no visual signs of corrosion 1000 hours of salt spray testing with no appreciable loss of strength Electrical Electrical connection IP66, PG-13.5 cable entry, max. 2.5 mm 2-strand wire (14 AWG) Operating temperature Dielectric strength Switch rating -13 F to +185 F (-25 C to +85 C) 2500 VAC, 50/60 Hz. for one minute ½ A @ 125 VDC non-inductive ¼ A @ 250 VDC non-inductive Electrical connection QUALITROL style circular 3 pin, ANSI style circular 3 pin, military spec MS3102E16-10P circular 3 pin, flying leads or terminal box Email info@qualitrolcorp.com www.qualitrolcorp.com

QUALITROL LPRD large pressure relief device Large Pressure Relief Device General QUALITROL Field Services To further improve reliability, QUALITROL provides comprehensive education and on-site commissioning services, maintenance contracts and technical support to all customers worldwide. Emergency response is available on all products and services. About QUALITROL QUALITROL Company LLC manufactures substation and transformer monitoring PI-LPRD00 and REV.26613 protection devices used by 2-4-08 electric utilities and manufacturing companies. It is the global leader in sales REV. 25877 and installations of transformer asset 1 3 protection equipment, fault recorders and fault locators. Established in 1945, QUALITROL Company produces thousands of different types of products on demand, each customized to customers unique requirements. 2008 QUALITROL Company LLC, an ISO 9001 system certified company. All rights reserved. Information subject to change without notice. All trademarks are properties of their respective companies, as noted herein. AP-P04-03L-01E. Email info@qualitrolcorp.com www.qualitrolcorp.com