1 FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage-treatment plants Other corrosive environments Ashcroft Inc. supplies highly reliable Ashcroft switches and controls for industrial and process applications. We begin with rock-solid designs, matching the most appropriate technology with the safety and reliability requirements of the applications. The materials of construction are specified to Ashcroft s exacting standards, and product is built to last in the toughest applications. Our modern, responsive manufacturing facility is supported by an extensive network of stocking distributors and factory sales offices located in virtually every part of the world. Special application assistance is always just a telephone call away. The Ashcroft B-Series switch line is designed to satisfy most switch requirements. Materials of construction have been selected for long life. A wide variety of precision switch elements are available to meet every application requirement, including hermetically sealed contacts for added reliability and safety. The actuators we use have been proven in more than 20 years of service in the world s plants and mills. Special designs are available for fire safety, NACE, limit control and other more stringent requirements. Simplicity and ease of use are stressed to improve reliability of the installation. Applications include: pumps, compressors, washers, filters, degreasers, evaporators, recovery systems, food processing, ground support equipment, reverse osmosis systems, heat exchangers, hydraulic systems, lubrication systems, marine equipment, textile machinery, heating and air conditioning equipment. Thermowells Thermowells must be used on any application where the stem of the temperature switch may be exposed to pressure, corrosive fluids or high velocity. Additionally, the use of a thermowell permits instrument interchange or calibration check without disturbing or closing down the process. Ashcroft temperature switches have bulb diameters to match 3 8 nominal bore thermowells. The bulbs have a sensitive portion length of 2 which can be used with 2 2 U dimensioned thermowells or longer. For maximum accuracy, a thermowell s U dimension should be selected to permit complete immersion of the sensitive portion plus when measuring the temperature of liquids; an extra 3 should be allowed when measuring the temperature of gases. Thermowell bushings should be used with remote mount temperature switches. We recommend the standard 3 bulb and code 69 Series bushings for use with any thermowell U dimension. A split rubber grommet allows easy installation and S dimension adjustment. All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft Inc /4 Ashcroft Inc., 250 East Main Street, Stratford, CT 0664 USA Tel: Fax: [email protected]
2 Temperature Switches B-Series temperature switches feature a SAMA Class II vapor pressure thermal system. This system provides quick, accurate response to process temperature changes with negligible ambient temperature effects. This is inherent in the design due to the precise relationship that exists between temperature and pressure according to the vapor pressure laws. A wide selection of sensing bulb and armored capillary lengths is available. The vapor pressure system design features small bulb sizes, making installation easy and cost-effective. All models feature ±.0% percent of span setpoint repeatability with very high overtemperature ratings. These standard designs perform well in applications where shock and vibration could be a problem and should be used with Ashcroft thermowells for bulb protection and ease of installation and maintenance. STANDARD TEMPERATURE RANGE SELECTION Nominal Range (),(5) Maximum Temperature Approximate Deadband () Switch Element (4) F C F 20, 26, 27 2, 24, , to to to to to to to to to to to 525 (3) 75 to to 750 (2) 260 to NOTES: All deadbands given in F. 2 Available with remote mount thermal systems only. 3 Not available with stem. 4 Dual switch element multiply single switch element value by.6 for approximate deadband. 5 Set and reset points must fall within the adjustable range.
3 B-SERIES TEMPERATURE SWITCH MODEL NUMBER: To specify the exact switch desired, select entries from appropriate tables as shown in example below T T X N H 6 50 to 260 F T4 T7 ENCLOSURE Temperature switch, Type 400, watertight enclosure meets NEMA 3, 4, 4X, 3 and IP66 requirements. Temperature switch, Type 700, explosion-proof enclosure meets Div. & 2, NEMA 7, 9 and IP66 requirements. 2 SWITCH ELEMENT SELECTION Order Switch Elements Code UL/CSA Listed SPDT 20 (7) Narrow deadband ac 5A, 25/250 Vac 2 Ammonia service 5A, 25/250 Vac 22 (6) Hermetically sealed switch, 5A, 25/250 Vac narrow deadband 23 Heavy duty ac 22A, 25/250 Vac 24 () General purpose 5A, 25/250/480 Vac 2A, 25 Vdc 4A, 250 Vdc; 6A, 30 Vdc 25 Heavy duty dc 0A, 25 Vac or dc, 8 HP, 25 Vac or dc 26 (7) Sealed environment proof 5A, 25/250 Vac 27 High temperature 300 F 5A, 25/250 Vac 28 (5) Manual reset trip on 5A, 25/250 Vac increasing 29 (5) Manual reset trip on 5A, 25/250 Vac decreasing 3 Low level (gold) contacts A, 25 Vac 32 Hermetically sealed switch, A, 25/250 Vac general purpose 5A, 30 Vdc 42 Hermetically sealed gold A, 25 Vac contacts 50 Variable deadband 5A, 25/250 Vac UL/CSA Listed Dual (2 SPDT) 6 (7) Dual narrow deadband 5A, 25/250 Vac 62 (7) Dual sealed environment 5A, 25/250 Vac proof 63 Dual high temp. 300 F 5A, 25/250 Vac 64 Dual general purpose 5A, 25/250/480 Vac 2A, 25 Vdc 4A, 250 Vdc 65 Dual ammonia service 5A, 25/250 Vac 67 (4,6) Dual hermetically sealed 5A, 25/250 Vac switch, narrow deadband 68 (4) Dual hermetically sealed A, 25/250 Vac switch, general purpose 5A, 30 Vdc 70 Dual low level gold contacts A, 25 Vac 7 (4) Dual hermetically sealed A, 25 Vac switch, gold contacts 3 THERMAL SYSTEM SELECTION Direct Mount Order Code System Material Style TS 3l6 SS Rigid Remote Mount Order Code System Material Line Length Style T05 36 SS 5 Capillary T0 36 SS 0 with T5 36 SS SS T20 36 SS 20 Spring T25 36 SS 25 Armor 4 BULB SELECTION Direct Mount Minimum Order S Thermowell Code Dimension U Dimension 027 (8) Remote Mount OPTIONS Use table on page 7 6 STANDARD TEMPERATURE RANGE SELECTION Adjustable Range F C 40 to to 60 0 to to to to to to to to to to to 750 (2) 260 to 400 NOTES: Standard switch. 2 Available with remote mount thermal systems only. 3 Dual switches are 2 SPDT snap-action switches, not independently adjustable. 4 Wires cannot be terminated inside T400 switch enclosure. 5 Not available with Type 700 enclosure. 6 Estimated dc rating, 2.5A, 28 Vdc (not UL listed). 7 Estimated dc rating, 0.4A, 20 Vdc (not UL listed). 8 Not available on 350 to 525 F. 9 Consult factory on remote mount for bulb lengths other than 3.
4 B-Series Switches Temperature OPTIONAL FEATURES AND ACCESSORIES B-SERIES SWITCH OPTIONS Appicable Switch Series Temperature Code Description All Ranges Notes XBX 2 Male NPT Bushing XCH Chained Cover XC8 CSA Approval XCN ATEX Directive 94/9/EC 2 XFP Fungus Proofing XFS Factory Adjusted Setpoint 3 XJK Left Conduit Connection 4 XJL 3 4 to 2 Reducing Bushing XJM Metric Electrical Conduit Connection M20 x.5 XK3 Terminal Block (700 Series only) 5 XLE 6 foot Leads on the Micro Switch XNH Tagging Stainless Steel XNN Paper Tag XPK Pilot Light(s) Top Mounted 6 XPM 3 4 Sealed Conduit Connection with 6 Lead Wires XTM 2 Pipe Mounting Bracket XUX IECEx Rating (700 Series only) NOTES: Standard on 400 Series Series only. 3 Advise static or working pressure for differential pressure switches. 4 Standard on 700 Series. N/A with DPDT element on 400 Series. 5 Terminal Blocks standard with 700 dual switches. 6 N/A on 700 Series. II 2GD Ex d IIC T6 Gb Ex t IIIC T85 C Db IP 6X (Ta = 20 C to +60 C)
5 Dimensions 400 Series Temperature switch direct mount Temperature switch remote mount 0.22 (6) 4.03 (02) Ø 0.28 (7) X 3 HOLES 2.27 (58).25 (32) 0.25 (6) 0.22 (6) 4.03 (02) Ø 0.28 (7) X 3 HOLES 2.27 (58).25 (32) 0.25 (6) 4.6 (7) 3.32 (84) 2.77 (70) 3/4 NPT 2.00 (5) 4.6 (7) 3.32 (84) 2.77 (70) 3/4 NPT 2.00 (5) 7/8 HEX Ø 3.26 (83) /2 NPT MALE.3 (33) S Ø 2.50 (64) L Ø (83) Ø (76) Temperature switch direct mount Temperature switch remote mount Ø 0.28 x 3 HOLES (7) 5.23 (33) (35) 5.20 (32) 2.8 (55) 0.32 (8) Ø 3.90 (99) 3/4 NPT 2 HOLES.22 (3) () 0.3 (8) Ø 0.28 x 3 HOLES (7) 3.6 (92) 5.23 (33) 5.20 (32) 2.8 (55) 0.32 (8) Ø 3.90 (99) (3) 0.03 () 0.3 (8) 4.37 ().93 (49) 7/8 HEX /2 NPT MALE (33) S.37 (35) 4.37 ().93 (49) 3/4 NPT 2 HOLES 2.50 (64) L 3.00 (76) Ø 0.37
6 All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft Inc /4 Ashcroft Inc., 250 East Main Street, Stratford, CT 0664 USA Tel: Fax:
B-Series Switches Pressure, Differential Pressure & Hydraulic
FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage-treatment
Data Sheet B-Series Switches Pressure, Differential Pressure & Hydraulic
FEATURES Adjustable setpoints 15-100% of range Fixed or limited adjustable deadband Wide selection of switch elements Explosion proof enclosure provides uncompromising protection Special designs for NACE
Compact pressure switch Flameproof enclosure Ex d Model PCA
Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring
Electronic, Digital and Mechanical Vibration Switches
PT500 Electro-Mechanical Vibration Switch Introduction The PT500 is an economical solution that provides basic vibration protection for rotating reciprocating machines. The PT500 uses an inertia sensitive
In-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
Electronic Flow Switches
Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
Explosion-Proof Electric Unit Heaters
Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,
Scraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.
Pump_PT580 Optional PT580-CFG PCM370 Optional DTM96 Buffered Dual Relay Remote Reset Local Display Condition Monitoring System PLC/DCS PT580 Digital Vibration Switch Introduction The PT580 Digital Vibration
Sanitary Type Electronic Flow Switches
Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts
P70, P72, and P170 Series Controls for Dual Pressure Applications
P70, P72, and P170 Series Controls for Dual Pressure Applications Product Bulletin Code No. LIT-125455 Issued August 30, 2012 Supersedes September 1, 2000 The P70, P72, and P170 controls for dual pressure
EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL
PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex
! WARNING. Before using product, read and understand instructions.
McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes
Flow switches Series AD/VH
Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
Thermometer in stainless steel with capillary and switch contacts
Design Type Case diameter Thermometer in and switch contacts 7308 = back flange for wall mounting 7312 = front flange for panel mounting 7310 = mounting bracket for wall mounting Dim 100 mm or 160 mm Accuracy
Centro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
Pressure Switch for gas and air
Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth
Commercial Gas Cooking Thermostats
BJWA Series Commercial Gas Thermostat A223 Commercial Gas Cooking Thermostats Designed specifically for heavy-duty commercial oven and griddle applications Hi-Temp thermostat with steel bulb and capillary
FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)
FLARE MONITORS Infrared Sensors for Monitoring Smokeless Flares, Pilots, and Flame Intensity FMDS2014 FLARE MONITOR (FM) Monitor smokeless flare combustion efficiency to maximize destruction of hazardous
In-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog
9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G Catalog January 07 Contents Commercial Pressure Switches Pressure Switches b Selection..............................................
% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power
.55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard
SQUARE D INDUSTRIAL CONTROL PRODUCTS
SQUARE D INDUSTRIAL CONTROL PRODUCTS CLASS 9012 3a INDUSTRIAL PRESSURE SWITCHES Type A Heavy duty switch for virtually any industrial application involving air, water, steam or oil Bellows, piston and
Worcester DS/DM Series UltraSwitch Switch box
Worcester DS/DM Series UltraSwitch Switch box Features DS/DM Series Ultraswitch Description The DS/DM Series UltraSwich from Flowserve Worcester provides cost efficient, accurate and reliable position
Microcor Wireless Transmitter (MWT)
Rohrback Cosasco Systems, Inc. Microcor Wireless Transmitter (MWT) Features: Highly Secure and Reliable Self Organizing Wireless Mesh Network High Resolution Metal Loss Measurement for all process environments
Rosemount DIN-Style Temperature Sensors and Thermowells (Metric)
Product Data Sheet July 2015 00813-0200-2654, Rev KA Rosemount DIN-Style Temperature Sensors and Thermowells (Metric) RTDs (0065) and thermocouples (0185) available to meet any process requirement DIN-style
Electric Process Heaters & Engineered Systems
50+ Years of Excellence Electric Process Heaters & Engineered Systems Company Info Gaumer Process is a world leader in the design and manufacturing of electric heaters, controls and engineered systems,
PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
V47 Series Temperature Actuated Modulating Water Valves
V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
Part I - Installation
400 Series Pressure and Differential Pressure Switches Types: H400, H402, H403, H400K, H402K, J400, J402, J403, J400K, J402K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read
98371000 REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 2011 ELKHART BRASS MFG. CO., INC.
81471067 Electric Monitor Motor Control Panel For use with Model 8394059 SPIT-FIRE Monitor Installation, Operation, and Maintenance Instructions FOR ATEX APPLICATIONS 1302 WEST BEARDSLEY AVENUE P.O. BOX
Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9
Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370
Pump_TM016 Pump Local Display TM0200 TM0200 4-20mA PLC/DCS Case 1 Pump Relay Output Module 4-20mA Optional PT371 Modbus PT373 Case 2 PCM370 TM016 Velocity/ Acceleration Vibration Transmitter Introduction
AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products
Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution
Product Brochure. Certified Mining Motors
Product Brochure Certified Mining Motors Profile Baldor Electric Company (a member of the ABB group) is a world leader in motors for the mining industry. In the continuous (24/7) operation of underground
DTS-HAZ DTS-HAZ-DC. Installation Instructions. for use with Self-Regulating, Constant Wattage & Mineral Insulated Electric Heating Cables
Installation Instructions DTS-HAZ DTS-HAZ-DC for use with Self-Regulating, Constant Wattage & Mineral Insulated Electric Heating Cables 1 PJ944-10 5625-81049 May 2015 2 DTS-HAZ & DTS-HAZ-DC 1 2 3 8 12
PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE
Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface
BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS
BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS INTRODUCTION Rupture discs are often used as primary pressure relief devices and to isolate pressure relief valves. When used as a primary pressure relief
T7079A,B Solid State Remote Temperature Controllers
T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature
Linear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
Explosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
Screw Plug Immersion Heaters
Immersion Heaters Overview Immersion Heaters consist of hairpin bent tubular elements brazed or welded into a screw plug and provided with terminal enclosures for electrical connections. Immersion Heaters
Micro Motion Model D and DL Coriolis Flow and Density Meters
Product Data Sheet PS-00388, Rev. F April 2013 Micro Motion Model D and DL Coriolis Flow and Density Meters Micro Motion Model D and DL sensors provide flow and density measurement for liquids, gases,
WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP
WILROY ATEX Approved HYDRAULICALLY ACTUATED DIAPHRAGM PUMP Williams and Milton Roy have combined technologies to design a pump blending the proven mroy hydraulic by-pass diaphragm design with the Williams
Honeywell Pressure Switches Line Guide
Honeywell Pressure Line Guide Better under pressure. For years, manufacturers and operators of heavy-duty equipment have trusted Honeywell pressure and vacuum switches. They re proven under pressure, in
REGULATORS 175/153 Series
175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed
VIBRATION SWITCHES SOLID STATE
SOLID STATE VIBRATION SWITCHES The PMC/BETA electronic vibration switch makes available in a relatively low-cost device many of the benefits formerly found only in high-end protection systems. Model Adjustable
THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE
THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE www.winters.com MANUFACTURER OF INDUSTRIAL INSTRUMENTATION Bi-Metal Thermometers Bi-Metal Thermometers Winters bi-metal thermometers are direct sensing
9000 Series Accelerometers Specifications
Technical Data 9000 Series Accelerometers Specifications Catalog Numbers EK-43781I, EK-43782I, EK-46255I, EK-45890I, EK-43784I, EK-47086I, EK-43792I, EK-47090I, EK-43799I, EK-43794I, EK-43795I, EK-43797I,
Thermostatic valve Type AVTA
MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The
SOLFRUNT Pressure Gauges and Other Products for the Process Industries
A1 SOLFRUNT Pressure Gauges and Other Products for the Process Industries AMETEK s line of high quality process gauges are specifically designed to meet the demanding needs of the chemical and petroleum
FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications
FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications Flow Measurement Flow Switches Level Switches Level Interface Switches FCI OEM SERIES Industrial Machinery Chemical Injection
Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)
Features Variants options Glass fiber reinforced polyester (GRP) enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 16 enclosure size options Various terminal
Pressure Gage and Swichgage Instruments OPL Series 4-1/2 in. (114mm) Diameter Dial
sect. 05 9600 rev. 206/08/0 Pressure Gage and Swichgage Instruments OPL Series 4-/2 in. (4mm) Diameter Dial The OPL-series pressure Swichgage instruments are combination pressure indicating gages with
OPTIMASS 6000 Technical Datasheet
OPTIMASS 6000 Technical Datasheet Sensor for mass flow The high performance meter for process industries Cryogenic, high temperature and high pressure options Supreme liquid and gas performance with CT
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
Technical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
COMBIMASS. Technical Data COMBIMASS eco-bio +
COMBIMASS Technical Data THE SYSTEM COMBIMASS The field transmitters of the COMBIMASS eco series are suitable for gas flow measurement and cover a wide range of different applications. The instruments
STX2100. Differential Pressure (Flow) Transmitter. GE Measurement & Control. Models FKC...5. Features
GE Measurement & Control STX2100 Differential Pressure (Flow) Transmitter Models FKC...5 The STX2100 differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge
Linear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
SITRANS F flowmeters SITRANS F M
Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update
Electronic Pressure Switches
Electronic Pressure Switches Electronic Pressure Switches c Pressure - Electronic Pressure Switches - Mechanical Pressure Switches - Pressure Transducer c Valves & Regulators c Temperature c Level c Flow
MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure
MAKING MODERN LIVING POSSIBLE Thermostatic valve AVTA Technical brochure 2 IC.PD.500.A3.02-520B3728 Danfoss A/S 07-2009/ RA-MC/mr Contents Page Features............................................................................................4
APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer
PT-400 Heavy Duty, Amplified Output Pressure Transducer C US The PT-400 offers high accuracy and reliability over a wide range of pressures. The small size, integrated electronics, wide operating temperature
Flameproof Audible Signal 115 db (A) Series YA90
Clifford Snell www.stahl.de > Max sound output 115 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > 32 selectable tones meeting international regulations > Light
36T Series Snap-Action Temperature Controls
36T Series Snap-Action Temperature Controls Snap-Action Temperature Control The 36T series of 1/2 bimetal temperature controls from Therm-O-Disc offers proven reliability in a compact, versatile, cost-effective
Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com
Model 62A MODEL 41A MODEL 44A AURORA 40A/60A Series SINGLE STAGE END PUMPS www.aurorapump.com SINGLE STAGE END PUMPS AURORA 40A/60A Series Single Stage End Suction Pumps Capacities to 4500 G.P.M. (1022
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
Control and Distribution Boxes made of Stainless Steel Series 8150
www.stahl.de > Circumferential protection channel prevents water entry > Extended temperature range due to high-quality seal s > Optionally with hinges / cam locks or screw-on cover > Hinge versions with
Rosemount 751 Field Signal Indicator
Rosemount 751 Field Signal Indicator Product Data Sheet August 2014 00813-0100-4378, Rev FA Available with an LCD display or analog meter Compact, rugged, and designed for industrial environments Available
Retractable Housings. InTrac 781 / 784 Versatile and Rugged For the Toughest Process Conditions INGOLD
INGOLD Leading Process Analytics Retractable Housings InTrac Retractable Sensor Housings for Harsh Applications Wide Range of Options Intelligent Sensor Locking System Highly Efficient Sensor Cleaning
4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
OPTIMASS 1400 Technical Datasheet
OPTIMASS 1400 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only
330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring
330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring Description The standard 330400 Accelerometer has a limited temperature range it can be exposed to, due to its signal
UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.
GE Measurement & Control UNIK 5800/5900 Flameproof/Explosion-Proof Pressure Sensing Platform The 5800 and 5900 are compact and rugged versions of the high performance UNIK 5000 pressure sensing platform
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:
Liquid Level Limit Switch liquiphant T FTL 20
Technical Information TI 64F/4/ae Liquid Level Limit Switch liquiphant T FTL 0 Level limit switch for liquids Applications The Liquiphant T FTL 0 is a level limit switch for virtually any kind of fluid
GE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping
GE Oil & Gas Texsteam * Pumps: precise chemical injection pumping 2 With a wide range of capacities and operating pressures, GE s versatile Texsteam pumps can handle challenging chemical pumping requirements
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
SECTION 11 78 13 MORTUARY REFRIGERATORS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in
A99B Series Temperature Sensors
FANs 125, 121, 930, 930.5 Product/Technical Bulletin A99 Issue Date 0615 A99B Series Temperature s The A99B Series Temperature s are passive PTC (Positive Temperature Coefficient) sensors. The A99B sensors
B40 Liquid Level Switch
B40 Liquid Level Switch D E S C R I P T I O N The Magnetrol B40 liquid level switch is specifically designed and constructed for high pressure, high temperature service conditions. F E A T U R E S Choices
OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250
MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic
4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems
Dynamic Solutions Leadership and Innovation in Valve Products and Valve Systems At ASCO, Valve Performance Begins and Ends With People 4 First of all, it begins with the people we serve. It is from them
Pipe Temperature Sensors
Pipe Temperature Sensors Model TE-703 / 704 RoHS Four immersion thermowell installation options brass adapter with 304 SS probe for adjustable insertion, plastic, galvanized steel or NEMA-4/IP-65 steel
Bimetal thermometer Model 52, industrial series
Mechanical temperature measurement Bimetal thermometer Model 52, industrial series WIKA data sheet TM 52.01 for further approvals see page 6 Applications A wide range of applications in machine building,
PIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS Frames 143T - 449TZ 5100 North IH 35 Round Rock, Texas 78681 Phone: 800-451-8798 512-255-4141 Fax: 512-244-5512 RECEIVING 1. Check
TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP
TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
SITRANS F flowmeters. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/12 Siemens FI 01 2010
Overview are designed for measuring the flow of electrically conductive mediums. The full program consists of three different types of flowmeters making Siemens unique in that it covers all possible applications
Flow Monitoring System
FMS-3 Product Data Sheet PS-00028 April 1997 Flow Monitoring System FMS-3 Flow Monitoring System The Micro Motion FMS-3 Flow Monitoring System is a microprocessor-based batch controller with rate, total,
Terminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
FCI ST75 Series Flow Meters
FCI ST75 Series Flow Meters Small Line, Mass Flow Meters for Industrial and Commercial Process Gases Low cost, easy installation flow measuring for 1/4 inch to 2 inch [6 mm to 51 mm] line sizes FCI ST75
Heating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft