Manual. MOVIDRIVE MDX61B Fieldbus Interface DFS22B PROFINET IO with PROFIsafe. Edition 04/2008 11616210 / EN



Similar documents
Manual. Fieldbus Interface DFE33B EtherNet/IP and Modbus/TCP. Edition 10/ / EN

Manual. MOVIDRIVE MDX61B Fieldbus Interface DFE13B EtherNet/IP. Edition 06/2006 FA / EN

Manual. MOVIDRIVE MDX61B Fieldbus Interface DFE11B Ethernet. Edition 10/2004 FA / EN

Manual. MOVIDRIVE MDX61B MOVI-PLC DHP11B Control Card. Edition 09/2005 FA / EN

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVIDRIVE MDX60B/61B Functional Safety

Drive Technology \ Drive Automation \ System Integration \ Services. DFD11B DeviceNet Fieldbus Interface. Manual. Edition 10/ / EN

Addendum to the Operating Instructions

Manual. MOVIFIT Function Level "Classic" Edition 05/ / EN

PROFINET IO Diagnostics 1

PROFINET the Industrial Ethernet standard. Siemens AG Alle Rechte vorbehalten.

1 Application Description Objective Goals... 3

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

PROFINET Diagnostics Software and Tools

Getting Started - SINAMICS Startdrive. Startdrive. SINAMICS Getting Started - SINAMICS Startdrive. Introduction 1

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Operating instructions. AS-i Profibus gateway AC1411 / AC /00 04/2014

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

Manual. Fieldbus Interface DFP21B PROFIBUS DP-V1. Edition 07/2006 FA / EN

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

Electronic-Key-System. Manual Electronic-Key Adapter EKS and EKS FSA with PROFINET Interface. Order no PROFINET

PROFINET IRT: Getting Started with The Siemens CPU 315 PLC

DeviceNet Bus Software Help for Programming an Allen Bradley Control System

Configuring PROFINET

CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual

CB15/CB155. PROFIBUS Module

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

CPU PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU PN/DP: Configuring an ET 200S as PROFINET IO device

xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English

Manual. MOVIAXIS MX Multi-Axis Servo Inverter XFE24A EtherCAT Fieldbus Interface. Edition 08/ / EN

GE Power Controls FIELDBUS APPENDIX PROFIBUS DP. Doc. No.: ASTAT Plus PB_Appendix-v0

Applications & Tools. Configuration of Messages and Alarms in WinCC (TIA Portal) WinCC (TIA Portal) Application description December 2012

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Using the WAGO PROFINET Coupler as Remote I/O with a Siemens S7 PLC

L5354 ControlNet Communications Interface

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

Software User Guide UG-461

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Crow Limited Warranty. Print Version 017

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

Teleservice via RS232 interface XC100/XC200

Soft-Starter SSW-06 V1.6X - Profibus DP, DeviceNet and EtherNet/IP

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

Overview and Applications of PROFINET. Andy Verwer Verwer Training & Consultancy Ltd

DeviceNet Communication Manual

WinCC. Communication Manual. Manual 2. This manual is part of the documentation package with the order number: 6AV6392-1CA05-0AB0 C79000-G8276-C156-01

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC B Simple Positioning Application Module

EPSON Network Image Express Card User s Guide

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Provides one channel for Ethernet over existing

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version Rev.

Installation and start-up guide NETA-21 remote monitoring tool

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

User manual Compact Web PLC WP240 series IEC-line

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

IntraVUE Plug Scanner/Recorder Installation and Start-Up

HARTING mcon 1000 Introduction and features

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library. Deleting program block Main [OB1] Copying program blocks

ABB RTU560A Series CMU & Modules

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

Application/Connection Examples

The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

1 Serial RS232 to Ethernet Adapter Installation Guide

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

The irnetbox Manager User Guide

Energy Communication Unit (ECU)

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

3.5 EXTERNAL NETWORK HDD. User s Manual

Nokia Siemens Networks. CPEi-lte User Manual

Procedure: You can find the problem sheet on Drive D: of the lab PCs. Part 1: Router & Switch

Linksys WAP300N. User Guide

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

Ha-VIS FTS 3000 Introduction and features

Configuration of Fieldbus Devices with Remote Access

Visualization SIMATIC. Visualization. Present sample project. HMI configuration. Insert HMI device from libraries 3. Configuring HMI connection 4

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

Ethernet Interface Manual Thermal / Label Printer. Rev Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

How-To-Do. Hardware Configuration SLIO CPU 014

I.S. 1 remote I/O system Redundant coupling via PROFIBUS DP

ABB Drives. User s Manual HTL Encoder Interface FEN-31

BACnet Automation Interface Module (Network Version)

PCS300 Universal IP Reporting Module V1.0

T3 Mux M13 Multiplexer

Ethernet Radio Configuration Guide

Ethernet/IP Comms between a WAGO and a Mettler Toledo JAGXTREME Terminal Application note

Provides one channel for Ethernet over existing

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

VAC 50/60Hz Power Adapter

Profinet to EDV111 Series LED Signs Siemens Function Block Software Manual

Phone Adapter. with 2 Ports for Voice-over-IP. Installation and Troubleshooting Guide. Model No. PAP2 Ver. 2. Voice

Copley Camming User Guide

1 How configure S7 PLC in the configuration tool

Transcription:

Drive Technology \ Drive Automation \ System Integration \ Services MOVIDRIVE MDX61B Fieldbus Interface DFS22B PROFINET IO with PROFIsafe Edition 04/2008 11616210 / EN Manual

SEW-EURODRIVE Driving the world

1 General Notes... 5 1.1 Structure of the safety notes... 5 1.2 Right to claim under limited warranty... 5 1.3 Exclusion of liability... 5 1.4 Copyright... 6 2 Safety Notes... 7 2.1 Other applicable documentation... 7 2.2 General safety notes for bus systems... 7 2.3 Safety functions... 7 2.4 Hoist applications... 7 2.5 Product names and trademarks... 7 2.6 Waste disposal... 8 3 Introduction... 9 3.1 Content of the manual... 9 3.2 Additional documentation... 9 3.3 Features... 9 3.3.1 MOVIDRIVE and PROFINET... 9 3.3.2 Access to all information... 10 3.3.3 Monitoring functions... 10 3.3.4 Diagnostics... 10 3.3.5 Fieldbus monitor... 10 4 Integrated Safety Technology... 11 4.1 Safety concept DFS22B in combination with DCS21B... 11 4.2 MOVIDRIVE B safety concept without option DCS21B... 12 4.2.1 Limitations... 12 4.2.2 Schematic representation of the safety concept using MOVIDRIVE B as an example... 13 5 Safety Conditions... 14 6 Assembly and Installation Instructions... 15 6.1 Installing option card DFS22B in MOVIDRIVE MDX61B... 15 6.2 Installing option card DFS22B/DCS21B in MOVIDRIVE MDX61B... 16 6.2.1 Before you begin... 17 6.2.2 Basic procedure for installing and removing an option card (MDX61B, sizes 1-6)... 18 6.3 Connection and terminal description for option DFS22B... 19 6.4 Pin assignment... 20 6.5 Shielding and routing bus cables... 21 6.6 TCP / IP addressing and subnets... 22 6.7 Setting IP address parameters via the DCP... 24 6.8 Procedure after replacing the unit... 25 6.9 Operating displays of the DFS22B option... 25 6.9.1 PROFINET LEDs... 25 Manual Fieldbus Interface DFS22B PROFINET IO with PROFIsafe 3

7 Configuration and Startup... 27 7.1 Configuring the PROFINET IO controller... 27 7.1.1 Assigning the PROFINET device name... 28 7.1.2 Configuring the PROFINET IO connection DFS22B... 30 7.1.3 Configuration example for the process data configuration of MOVIDRIVE B... 35 7.2 Setting the MOVIDRIVE MDX61B inverter... 36 7.3 Configuring PROFIsafe with STEP 7... 37 7.3.1 Description of the F parameters... 38 7.3.2 Safety diagnostics via PROFINET... 40 8 Operating Characteristics on PROFINET... 41 8.1 Introduction... 41 8.2 The integrated Ethernet switch... 43 8.3 Process data configuration... 44 8.4 Controlling the MOVIDRIVE MDX61B inverter... 45 8.4.1 Control example for SIMATIC S7 with MOVIDRIVE MDX61B... 46 8.4.2 PROFINET timeout (MOVIDRIVE MDX61B)... 46 8.4.3 Fieldbus timeout response (MOVIDRIVE MDX61B)... 46 8.5 SIMATIC S7 program example... 47 8.6 PROFINET alarms taking the example of MOVIDRIVE B... 48 9 Parameter Setting via PROFIdrive Database 47... 50 9.1 Introduction to PROFINET records... 50 9.1.1 Properties of PROFINET devices from SEW-EURODRIVE... 51 9.2 Structure of the PROFINET parameter channel... 52 9.2.1 Configuration sequence via database 47... 53 9.2.2 Processing sequence for controller / supervisor... 54 9.2.3 Addressing lower-level inverters... 55 9.2.4 MOVILINK parameter requests... 56 9.2.5 PROFIdrive parameter requests... 61 9.3 Reading or writing parameters via database 47... 66 9.3.1 Sample program for SIMATIC S7... 66 9.3.2 PROFINET technical data for MOVIDRIVE DFS22B... 66 9.3.3 Error codes of PROFINET services... 67 10 Integrated Web Server... 68 10.1 Software requirements... 68 10.2 Security settings... 68 10.3 Structure of the MOVIDRIVE MDX61B with option DFS22B homepage... 69 10.4 Structure of the diagnostic applet... 70 10.5 Access protection... 73 11 MOVITOOLS MotionStudio via Ethernet... 74 11.1 Overview... 74 11.2 Workflow for device configuration... 75 11.3 Communication with external devices... 78 12 Error Diagnostics... 80 12.1 Diagnostic procedures... 80 13 Technical Data... 83 13.1 DFS22B for MOVIDRIVE B... 83 14 Index... 84 4 Manual Fieldbus Interface DFS22B PROFINET IO with PROFIsafe

General Notes Structure of the safety notes 1 Manual 1 General Notes 1.1 Structure of the safety notes The safety notes in this manual are designed as follows: Pictogram SIGNAL WORD! Type and source of danger. Possible consequence(s) if the safety notes are disregarded. Measure(s) to prevent the danger. Pictogram Signal word Meaning Consequences in case of disregard Example: DANGER! Imminent danger Severe or fatal injuries General danger WARNING! Possible dangerous situation Severe or fatal injuries CAUTION! Possible dangerous situation Minor injuries Specific danger, e.g. electric shock STOP! Possible damage to property Damage to the drive system or its environment NOTE Useful information or a tip Simplifies the handling of the drive system 1.2 Right to claim under limited warranty A requirement of fault-free operation and fulfillment of any rights to claim under limited warranty is that you adhere to the information in the operating instructions. Therefore, read the manual before you start working with the unit! Make sure that the manual is available to persons responsible for the plant and its operation, as well as to person who work independently on the unit. You must also üensure that the documentation is legible. 1.3 Exclusion of liability You must comply with the information in the MOVIDRIVE B documentation to ensure safe operation and to achieve the specified product characteristics and performance. SEW-EURODRIVE assumes no liability for injury to persons or damage to equipment or property resulting from non-observance of the operating instructions. In such cases, any liability for defects is excluded. Manual Fieldbus Interface DFS22B PROFINET IO with PROFIsafe 5

General Notes 1 Copyright 1.4 Copyright 2008 SEW-EURODRIVE. All rights reserved. Unauthorized reproduction, copying, distribution or any other use of the whole or any part of this documentation is strictly prohibited. 6 Manual Fieldbus Interface DFS22B PROFINET IO with PROFIsafe

Safety Notes Other applicable documentation 2 2 Safety Notes 2.1 Other applicable documentation Only trained personnel observing the relevant accident prevention regulations and the following documents are permitted to install and startup the unit! "MOVIDRIVE MDX60B/61B" operating instructions "MOVIDRIVE MDX61B Safety Module Option DCS21B/31B" manual Read through this documentation carefully before you start installation and startup of the option DFS22B. As a prerequisite to fault-free operation and fulfillment of warranty claims, you must adhere to the information in the documentation. 2.2 General safety notes for bus systems This communication system allows you to match the MOVIDRIVE B inverter to the specifics of your application. As with all bus systems, there is a danger of invisible, external (as far as the inverter is concerned) modifications to the parameters which give rise to changes in the unit behavior. This may result in unexpected (not uncontrolled) system behavior. 2.3 Safety functions The MOVIDRIVE MDX61B inverter may not perform safety functions without higherlevel safety systems. Use higher-level safety systems to ensure protection of personnel and equipment. Ensure that the data in the following documentation is observed for safety applications. Safe Disconnection for MOVIDRIVE B Use only those components in safety applications that were explicitly delivered in this design by SEW-EURODRIVE! 2.4 Hoist applications MOVIDRIVE MDX60B/61B may not be used as a safety device in hoist applications. Use monitoring systems or mechanical protection devices as safety equipment to avoid possible damage to property or injury to people. 2.5 Product names and trademarks The brands and product names in this manual are trademarks or registered trademarks of the titleholders. Manual Fieldbus Interface DFS22B PROFINET IO with PROFIsafe 7

Safety Notes 2 Waste disposal 2.6 Waste disposal Please follow the current national regulations. Dispose of the following materials separately in accordance with the country-specific regulations in force: Electronics scrap Plastics Sheet metal Copper etc. 8 Manual Fieldbus Interface DFS22B PROFINET IO with PROFIsafe

Introduction Content of the manual 3 3 Introduction 3.1 Content of the manual This user manual describes the installation of the DFS22B option card PROFINET IO with PROFIsafe in the MOVIDRIVE MDX61B inverter. startup of the MOVIDRIVE unit on the PROFINET IO RT fieldbus system configuration of PROFINET using GSD files operation of MOVITOOLS MotionStudio via PROFINET. 3.2 Additional documentation For information on how to connect MOVIDRIVE B easily and effectively to the PROFINET IO fieldbus system, you should request the following publications about fieldbus technology in addition to this user manual: MOVIDRIVE Fieldbus Unit Profile manual MOVIDRIVE B system manual MOVIDRIVE MDX61B Safety Monitor DCS21B/31B manual The MOVIDRIVE Fieldbus Unit Profile manual and the MOVIDRIVE B system manual describe the fieldbus parameters and their coding, and explains the whole range of control concepts and application options in the form of brief examples. The "MOVIDRIVE Fieldbus Unit Profile" manual contains a list of all inverter parameters that can be read or written via the various communication interfaces, such as system bus, RS485 and also via the fieldbus interface. 3.3 Features The MOVIDRIVE MDX61B inverter enables you to use the option DFS22B PROFINET IO with PROFIsafe to connect to higher-level automation systems via PROFINET IO RT thanks to its powerful, universal fieldbus interface. 3.3.1 MOVIDRIVE and PROFINET The unit behavior of the inverter which forms the basis of PROFINET operation is referred to as the unit profile. It is independent of any particular fieldbus and is therefore a uniform feature. This feature allows the user to develop applications independent of the fieldbus in operation. This makes it much easier to change to other bus systems, such as DeviceNet (option DFD). Manual Fieldbus Interface DFS22B PROFINET IO with PROFIsafe 9

Introduction 3 Features 3.3.2 Access to all information MOVIDRIVE MDX61B offers digital access to all drive parameters and functions via the PROFINET interface. The drive inverter is controlled via fast, cyclic process data. You can use this process data channel to enter setpoints, such as the setpoint speed, ramp generator time for acceleration/deceleration, etc., and to trigger various drive functions such as enable, controller inhibit, normal stop, rapid stop, etc. At the same time you can also use this channel to read back actual values from the drive inverter, such as actual speed, current, unit status, error number or reference signals. 3.3.3 Monitoring functions Using a fieldbus system requires additional monitoring functions for the drive technology, for example, time monitoring of the fieldbus (fieldbus timeout) or rapid stop concepts. You can, for example, adapt the monitoring functions of MOVIDRIVE specifically to your application. You can determine, for instance, which of the drive inverter's fault responses should be triggered in the event of a bus error. It is a good idea to use a rapid stop function for many applications. However you can also freeze the last setpoints so that the drive continues to operate with the most recently valid setpoints (for example, conveyor belt). As the functions of the control terminals are still active in fieldbus operation, you can still implement fieldbus-independent emergency stop concepts via the inverter terminals. 3.3.4 Diagnostics The MOVIDRIVE inverter offers numerous diagnostic options for startup and service. For example, you can use the integrated fieldbus monitor to control setpoint values sent from the higher-level controller and the actual values. The integrated Web server allows you to access the diagnostic values using a standard browser. 3.3.5 Fieldbus monitor You are also supplied with a range of additional information on the status of the fieldbus interface. In conjunction with the MOVITOOLS MotionStudio PC software, the fieldbus monitor function offers you an easy-to-use diagnostic tool for setting all drive parameters (including the fieldbus parameters) and for displaying the fieldbus and device status information in detail. 10 Manual Fieldbus Interface DFS22B PROFINET IO with PROFIsafe

Integrated Safety Technology Safety concept DFS22B in combination with DCS21B 4 4 Integrated Safety Technology 4.1 Safety concept DFS22B in combination with DCS21B The PROFIsafe fieldbus interface DFS22B has an integrated CAN interface. The DFS22B filters the safe communication and sends it safely to the option DCS21B via the integrated CAN interface. The following requirements are met by a 2-channel redundant system structure of the DCS21B safety subassembly with the help of suitable monitoring mechanisms: SIL3 to EN 61508 Category 4 to EN 954-1 Performance level e to EN ISO 13849-1 When the system detects an error, it responds by switching to the safe state. In this way, the safety function is realized in the form of safety inputs and outputs with connection to a higher-level safety control via PROFIsafe communication. The safe inputs / outputs of DCS21B are not evaluated locally or processed logically. They are evaluated in the higher-level safety-oriented PLC. In conjunction with option DCS21B, the DC 24 V safe stop input at X17 of the MOVIDRIVE inverter can be disconnected, thus bringing the drive to a safe stop. In this context, observe the following safety concept of the MOVIDRIVE drive inverter and all safety notes, conditions and installation regulations in this documentation. STOP! The safety function of the MOVIDRIVE B is only permitted for applications up to category 3 according to EN 954-1. Standard CPU F- CPU Master PD PROFIsafe PROFIsafe PD safety-oriented PROFIBUS/ PROFINET connection Inverter PROFIsafe MOVIDRIVE + DCS21B B 62315AEN Manual Fieldbus Interface DFS22B PROFINET IO with PROFIsafe 11

Integrated Safety Technology 4 MOVIDRIVE B safety concept without option DCS21B 4.2 MOVIDRIVE B safety concept without option DCS21B In case of danger, any potential risk to a machine must be eliminated as quickly as possible. Standstill with restart prevention is generally the safe condition for preventing dangerous movements. The MOVIDRIVE MDX60B/61B inverter is characterized by the option of connecting an external fail-safe, approved emergency stop relay (according to safety category 3, EN 954-1). This device disconnects all active elements (disconnection of the safety-oriented DC 24 V power supply of the output stage control) that generate the pulse trains to the power output stage (IGBT) when a connected control device (e.g. E-STOP button with latching function) is activated. Disconnecting the DC 24 V at the positive and negative pole ensures that the supply voltages required for operating the frequency inverter and consequently for generating a rotating field of pulse patterns (which allow the generation of a rotating field) are safely interrupted, thus preventing automatic restart. Instead of galvanic separation of the drive from the power supply by means of relays or switches, the disconnection of the DC 24 V supply described here safely prevents the control of the power semiconductors in the frequency inverter. This process disconnects the rotating field generation for the respective motor. The individual motor cannot develop any torque in this state even though the mains voltage is still present. The requirements for the emergency stop relay are clearly defined in the following sections and must be strictly observed. Using a suitable external circuit via an emergency stop relay with approval for at least safety category 3 disconnection for at least safety category 3 allows for operation of the MOVIDRIVE MDX60B/61B inverter with safe disconnection to stop category 0 or 1 (to EN 60204-1) and ensures protection against restart according to safety category 3 (to EN 954-1). 4.2.1 Limitations STOP! If the DC 24 V voltage supply is only disconnected safely at the positive pole, do not generate any test pulses here when the drive is disconnected. Important: The safety concept is only suitable for performing mechanical work on system/machine components. Important: A system/machine-specific risk analysis must be carried out by the system/machine manufacturer and taken into account for the use of the MOVIDRIVE B drive inverter. Danger of fatal injury: If the 24 V voltage supply is disconnected, voltage is still present at the inverter DC link. Important: If work is carried out on the electrical section of the drive system, the supply voltage must be disconnected using an external maintenance switch. 12 Manual Fieldbus Interface DFS22B PROFINET IO with PROFIsafe

Integrated Safety Technology MOVIDRIVE B safety concept without option DCS21B 4 4.2.2 Schematic representation of the safety concept using MOVIDRIVE B as an example Uz+ Uz- [17] [1] SNT HV 24V int. 24V ext. SNT NV 24V int. [2] 24V ext./ 24V int. [7] 24V GND [5] [6] [4] S24V S0V24 GND 24V S0V24 S VI 24 SNT [3] MOVIDRIVE B CAN RS485 Binary IN [9] Binary OUT [16] [8] [10] Analog IN Analog OUT [15] PWM Uz+ M [11] [14] [13 ] Uz- [12] L1 L2 L3 61519AXX [1] High-voltage switched-mode power supply [2] Low-voltage switched-mode power supply [3] Emergency stop relay (external) approved for at least category 3 according to EN 954-1 [4] Safety-oriented DC 24 V voltage supply [5] Safety switched mode power supply (SNT) [6] Electrical isolation [7] Safety circuit [8] Feedback to the central processing unit: Voltage supply for output stage control OK (not in safety circuit) [9] Voltage supply for control of the power transistors [10]DC 24 V safety switched-mode power supply disconnected / Brake applied (not in safety circuit) [11] Motor [12] Power section [13] Temperature detection [14] Position detection [15] Pulse width modulated signals for the output stage [16] Central processing unit [17] Fieldbus connection Manual Fieldbus Interface DFS22B PROFINET IO with PROFIsafe 13

Safety Conditions 5 MOVIDRIVE B safety concept without option DCS21B 5 Safety Conditions NOTE For information on the safety-relevant conditions, please refer to the following publications: Manual: "MOVIDRIVE MDX60B/61B Safe Disconnection Conditions" Manual: "MOVIDRIVE MDX61B Safety Monitor DCS21B/31B" 14 Manual Fieldbus Interface DFS22B PROFINET IO with PROFIsafe

Assembly and Installation Instructions Installing option card DFS22B in MOVIDRIVE MDX61B 6 6 Assembly and Installation Instructions This section provides you with information on installing the option card DFS22B PROFINET IO with PROFIsafe in MOVIDRIVE MDX61B. 6.1 Installing option card DFS22B in MOVIDRIVE MDX61B NOTES Only SEW-EURODRIVE personnel may install or remove option cards for MOVIDRIVE MDX61B size 0. Users may only install and remove options cards for MOVIDRIVE MDX61B sizes 1 to 6. You must insert the option DFS22B PROFINET IO with PROFIsafe into the fieldbus slot [1]. Use only connectors and cables approved for PROFINET IO for the wiring. [1] 62188AXX Manual Fieldbus Interface DFS22B PROFINET IO with PROFIsafe 15

Assembly and Installation Instructions 6 Installing option card DFS22B/DCS21B in MOVIDRIVE MDX61B 6.2 Installing option card DFS22B/DCS21B in MOVIDRIVE MDX61B NOTES Option DCS21B can only be used in combination with the fieldbus interface DFS22B. In this case, option DCS21B must be plugged into the expansion slot and option DFS22B into the fieldbus slot. The DCS21B option can only be installed in MOVIDRIVE MDX61B sizes 1 to 6, not in size 0. The prefabricated cable DAE34B (part number 1821 307 3) is used for the CAN bus connection between terminal X86 of DCS21B and terminal X31 of option DFS22B. Cable DAE34B is included in the scope of delivery for option DCS21B. MOVIDRIVE MDX61B DCS21B DFS22B DCS21B/ DAE34B X86 62320AXX 16 Manual Fieldbus Interface DFS22B PROFINET IO with PROFIsafe

Assembly and Installation Instructions Installing option card DFS22B/DCS21B in MOVIDRIVE MDX61B 6 6.2.1 Before you begin Read the following notes before installing or removing an option card: Disconnect the inverter from the power. Switch off the DC 24 V and the supply voltage. Take appropriate measures (discharge strap, conductive shoes, etc.) to protect the option card from electrostatic charge before touching it. Before installing the option card, remove the keypad and the front cover (see the MOVIDRIVE MDX60B/61B operating instructions, Sec. "Installation"). After installing the option card, replace the front cover and the keypad (see the MOVIDRIVE MDX60B/61B operating instructions, Sec. "Installation"). Keep the option card in its original packaging until immediately before you are ready to install it. Hold the option card by its edges only. Do not touch any of the subassemblies. Manual Fieldbus Interface DFS22B PROFINET IO with PROFIsafe 17

Assembly and Installation Instructions 6 Installing option card DFS22B/DCS21B in MOVIDRIVE MDX61B 6.2.2 Basic procedure for installing and removing an option card (MDX61B, sizes 1-6) 2. 1. 2. 1. 3. 3. 3. 4. 4. 60039AXX 1. Remove the two retaining screws holding the card retaining bracket. Pull the card retaining bracket out evenly from the slot (do not twist!). 2. Remove the 2 retaining screws from the black cover plate on the card retaining bracket. Remove the black cover plate. 3. Position the option card onto the retaining bracket so that the 3 retaining screws fit into the corresponding holes on the card retaining bracket. 4. Insert the retaining bracket with installed option card into the slot, pressing slightly so it is seated properly. Secure the card retaining bracket with the two retaining screws. 5. To remove the option card, follow the instructions in reverse order. 18 Manual Fieldbus Interface DFS22B PROFINET IO with PROFIsafe

Assembly and Installation Instructions Connection and terminal description for option DFS22B 6 6.3 Connection and terminal description for option DFS22B Part number DFS22B PROFINET IO fieldbus interface with PROFIsafe 1821 1844 NOTES The "DFS22B PROFINET IO fieldbus interface with PROFIsafe" option is only possible in conjunction with MOVIDRIVE MDX61B, not with MDX60B. Plug the DFS22B option into the fieldbus slot. Front view of DFS22B Description Terminal/ DIP switch Function DFS22B RUN BUS FAULT LED RUN (red/yellow/green) LED BUS FAULT (red/yellow/green) Shows the current status of the DFS22B. Shows the status of the PROFINET IO connection. 3 GND X31 2 1 CL CH X31: CAN bus connection X31:3 GND X31:2 CL X31:1 CH DGNDCAN Low CAN High X30 X30: Ethernet connection LED Link (green) LED Activity (yellow) X32 X32: Ethernet connection LED Link (green) LED Activity (yellow) Def IP AS 0 1 PROFINET IO DIP switch AS DEF IP Auto setup for gateway operation (without function) Resets the address parameters to the following default values: IP address: 192.168.10.4 Subnet mask: 255.255.255.0 Gateway: 1.0.0.0 PROFINET device name: PNETDeviceName_MACID 62186AXX Manual Fieldbus Interface DFS22B PROFINET IO with PROFIsafe 19

Assembly and Installation Instructions 6 Pin assignment 6.4 Pin assignment Use prefabricated, shielded RJ45 plug connectors to ISO/IEC 11801 edition 2.0, category 5. [6] [3] [2] [1] 123 6 A B Figure 1: Pin assignment of an RJ45 plug connector 54174AXX A = Front view B = View from back [1] Pin 1 TX+ Transmit Plus [2] Pin 2 TX Transmit Minus [3] Pin 3 RX+ Receive Plus [6] Pin 6 RX Receive Minus MOVIDRIVE B PROFINET connection To connect the DFS22B option, connect the PROFINET interface X30 or X32 (RJ45 connector) with a shielded twisted-pair cable to category 5, class D in accordance with IEC 11801 edition 2.0. The integrated switch helps you implement a line topology and provides an autocrossing functionality NOTES In accordance with IEEE 802.3, the maximum permitted cable length for 10/100 MBaud Ethernet (10BaseT / 100BaseT), e.g. between DFS22B and a switch, is 100 m. With PROFINET IO, prioritized Ethernet frames with the frame ID 8892 hex are used for real-time data exchange via the VLAN tag. You must, therefore, use switched networks. The switches must support prioritization. Hubs are not permitted. Data transfer takes place in a full-duplex mode with 100 MBit. For detailed information on the cabling, please refer to the "PROFINET Installation Guideline" documentation, which is published by the PROFINET User Organization. 20 Manual Fieldbus Interface DFS22B PROFINET IO with PROFIsafe

Assembly and Installation Instructions Shielding and routing bus cables 6 6.5 Shielding and routing bus cables Only use shielded cables and connection elements that meet the requirements of category 5, class D to ISO/IEC 11801 edition 2.0. Correct shielding of the bus cable attenuates electrical interference that may occur in industrial environments. The following measures ensure the best possible shielding: Manually tighten the mounting screws on the connectors, modules, and equipotential bonding conductors. Use only connectors with a metal housing or a metallized housing. Connect the shielding in the connector over a wide surface area. Apply the shielding of the bus cable on both ends. Route signal and bus cables in separate cable ducts. Do not route them parallel to power cables (motor leads). Use metallic, grounded cable racks in industrial environments. Route the signal cable and the corresponding equipotential bonding close to each other using the shortest possible route. Avoid using plug connectors to extend bus cables. Route the bus cables closely along existing grounding surfaces. STOP! In case of fluctuations in the ground potential, a compensating current may flow via the bilaterally connected shield that is also connected to the protective earth (PE). In such a case, make sure you supply adequate equipotential bonding in accordance with relevant VDE regulations. Manual Fieldbus Interface DFS22B PROFINET IO with PROFIsafe 21

Assembly and Installation Instructions 6 TCP / IP addressing and subnets 6.6 TCP / IP addressing and subnets Introduction The settings for the address of the IP protocol are made using the following parameters: IP address Subnet mask Standard gateway The addressing mechanisms and subdivision of the IP networks into subnets are explained in this chapter to help you set the parameters correctly. IP address The IP address is a 32-bit value that uniquely identifies a station in the network. An IP address is represented by four decimals separated by decimal points. Example: 192.168.10.4 Each decimal stands for one byte (= 8 bits) of the address and can also be represented using binary code ( following table). Byte 1 Byte 2 Byte 3 Byte 4 11000000. 10101000. 00001010. 00000100 The IP address comprises a network address and a station address ( following table). Network address Station address 192.168.10 4 The part of the IP address that denotes the network and the part that identifies the station is determined by the network class and the subnet mask. Station addresses cannot consist of only zeros or ones (binary) because they represent the network itself or a broadcast address. Network classes The first byte of the IP address determines the network class and as such represents the division into network addresses and station addresses. Value range Byte 1 Network class Complete network address (Example) Meaning 0... 127 A 10.1.22.3 10 = Network address 1.22.3 = Station address 128... 191 B 172.16.52.4 172.16 = Network address 52.4 = Station address 192... 223 C 192.168.10.4 192.168.10 = Network address 4 = Station address This rough division is not sufficient for many networks. They also use an explicit, adjustable subnet mask. Subnet mask A subnet mask is used to divide the network classes into even finer sections. The subnet mask is represented by four decimals separated by decimal points, in the same way as the IP address. Every decimal stands for one byte. Example: 255.255.255.128 Each decimal stands for one byte (= 8 bits) of the subnet mask and can also be represented using binary code (see following table). Byte 1 Byte 2 Byte 3 Byte 4 11111111. 11111111. 11111111. 10000000 If you compare the IP address with the subnet mask, you can see that in the binary representation of the subnet mask all ones determine the network address and all the 22 Manual Fieldbus Interface DFS22B PROFINET IO with PROFIsafe

Assembly and Installation Instructions TCP / IP addressing and subnets 6 zeros determine the station address (see the following table). IP address Subnet mask Byte 1 Byte 2 Byte 3 Byte 4 decimal 192. 168.. 10. 128 Binary 11000000. 10101000. 00001010. 10000000 decimal 255. 255. 255. 128 Binary 11111111. 11111111. 11111111. 10000000 The class C network with the address 192.168.10. is further subdivided into 255.255.255.128 using the subnet mask. Two networks are created with the addresses 192.168.10.0 and 192.168.10.128. The following station addresses are permitted in the two networks: 192.168.10.1... 192.168.10.126 192.168.10.129... 192.168.10.254 The network stations use a logical AND operation for the IP address and the subnet mask to determine whether there is a communication partner in the same network or in a different network. If the communication partner is in a different network, the standard gateway is addressed. Standard gateway The standard gateway is also addressed via a 32-bit address. The 32-bit address is represented by four decimal separated by decimal points. Example: 192.168.10.1 The standard gateway establishes a connection to other networks. In this way, a network station that wants to address another station can use a logical AND operation with the IP address and the subnet mask to decide whether the desired station is located in the same network. If this is not the case, the station addresses the standard gateway (router), which must be part of the actual network. The standard gateway then takes on the job of transmitting the data packages. Manual Fieldbus Interface DFS22B PROFINET IO with PROFIsafe 23