HCE80/HCC80/HCE80R/HCC80R



Similar documents
Smile. The All-In-One Heating Controller

HERZ-Thermal Actuators

CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Heating Controller. Building Technologies HVAC Products

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

RRV934. Multi-controller. Synco living

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

Electronic Control Devices The European Product Catalogue 2007

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

ACS-30-EU-EMDR-10-MOD

Electronic Control Devices The European Product Catalogue 2007

Drayton Digistat +2RF/+3RF

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted xx, xx, xx

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

T5000 T000 LCD Digital Fan Coil Thermostat

Product and functional description

RF 1. Contents: Connecting diagram. Detailed information:

Product and Application Description

ABB i-bus KNX Fan Coil Controller FC/S 1.1

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

T7560A,B,C Digital Wall Module

Heating Actuators in the MIX2 Series HMG 6 T, HME 6 T and FIX2 HM 12 T

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

User Manual THR840DUK Digital Thermostat

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

T-100-R Installation Guide

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

38 Series - Relay interface modules A

Controller board and power supply for vivimat III systems

Rack mounted telephone- and leased line modem for industrial applications

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Adjustable room thermostat for heating only or cooling only systems

Universal control module for motorized devices

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Transmitter Actuator 230V wave UP 560. Operation

15 Series - Electronic step relay and dimmer. Features SERIE

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

MINI MCR-SL-R-UI(-SP)

CO2 Alarm. Operation. Application

QuickSpecs. HP 480/277 Volt Solutions. Overview

Flush-mounted room thermostats

SECTION DETECTION AND ALARM

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

HM-W536 Install Guide

EM6556 e-domotica Mini Switch

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Inwall Room Temperature Unit

ELECTRIC CENTRAL HEATING FLOW BOILER

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Danfoss Link Mobile Phone Butler

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Quick Connect. quick - simple - efficient.

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

38 Series - Relay interface modules A

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Telephone- and leased line modem for industrial applications TD-36

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Safety automation solutions

New XUY roller sensors

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

Inductive Proximity Sensors

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Digital display DA 48

Heating, air-conditioning, cooling

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331)

IntesisBox KNX LG Air Conditioning

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Relés e Contatores de Estado Sólido SIRIUS

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

HVAC Processes. Lecture 7

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Electric Rotary Actuator - On/Off or programmable control actuator

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

ECL Comfort 110 Application 130. Weather compensated flow temperature control of heating and boiler systems. Instructions

Install Guide CT101. Caution. Caution

Transcription:

HCE80/HCC80/HCE80R/HCC80R UNDERFLOOR HEATING-ZONEING CONTROLLERS PRODUCT DATA FEATURES Easy and fast installation because the new wiring design Pluggable terminals for fast wiring connection because clamp contacts Integrated pump relay for pump control Relay (230V AC non potential free contact) Integrated antenna for the controllers HCC80 and HCC80R only External antenna for HCE80 and HCE80R only Up to 3 controllers can be connected to one antenna external HRA80 or integrated antenna Basic 5 configuration 5 zones Easy extendable with HCS80 for up to 8 zones Central operating via HCM200D / CM67z possible LED indication for voltage, operation mode, status and errors, RF check Outputs for a maximum of 24 thermal actuators Analogue output for boiler feedback to MCR200 / MCR40/ Panther / Smile (only HCE80/HCC80) Boiler control with integrated boiler relay potential free contact 42V (only HCE80R and HCC80R) Boiler feedback in dependence of valve setting with HC60NG possible Switchable between normally closed/open thermal actuators Potential free switch over contact heating / cooling GENERAL The underfloor heating-zoning controllers are used for individual room temperature control. The applications are underfloor heating and radiator control as well. Each zone can be controlled with easily operating devices used as analogue or digital interface. The controllers are designed with an intelligent control algorithm (Fuzzy control) to keep the room setpoint temperature constant. Because of the used system components HCW82/HCF82/CM67z the measured room temperature will be sent to the controllers. The basic configuration of each controller HCE80/HCC80/HCE80R and HCC80R is 5 zones however it can be upgraded up to 8 zones by using the extension module HCS80. Each zone can be controlled individually with time program by using the CM67z and HCM200D. With HCM200D up to 16 zones can be controlled with their own time program which save energy costs. Two types of controllers are provided with internal and external antenna HRA80. Up to 3 controllers can be connected to one antenna. The controllers HCE80/HCE80R are connected with the external antenna HRA80. The controllers HCC80/HCC80R include the antenna on the circuit board. The antenna includes also the transceiver 868,3MHZ. Because of the new wiring concept the thermal actuators can be installed very fast and pre wired without screws. All connectors are pluggable. Cooling applications are also possible by switching from heating into the cooling mode with potential free change over contact. Note: The controllers HCE80/HCC80/HCE80R and HCC80R have the same functionality exception the output for the boiler feedback. HCE80/HCC80: Analogue output for OTC controllers MCR, Panther, Smile (additional boiler relay not available) HCE80R/HCC80R: Additional boiler relay 42V (analogue output for OTC controllers is not available

SPECIFICATIONS Electrical Voltage supply : 230 V AC, 50 Hz + 10 % / -15 Power consumption Integrated pump relay Safety fuse Optional Wiring Admissible cable types and lengths : Thermal actuators Cable diameter Cable cross-section Strip length :max. 1750 VA with connected Pump6A) max180 VA without pump : 42 Volt potential contact, 6A : Ceramics safety fuse 230 VAC, 2,5 A swift, 5 x 20 mm : Expansion module HCS80 enhance the controller to 8 zones Min. 3.5 mm/max. 5.3mm Max. 400 m Max. 1.0 mm² 4 mm Network and pump connection 230 VAC Outside cable diameter Cable cross-section Strip length Antenna Min. 8.0 mm/max. 11 mm Max. 100 m Max. 1.5 mm² 7 mm Max. 30 m Cable cross-section / type JE-LiYCY 2x2x0.8 mm²; JE-Y(St)2Y 2x2x0.8 mm²; 2 x 0.5 mm² Heating / Cooling, Boiler feedback Cable cross-section / type Max. 100 m JE-LiYCY 2x2x0.8 mm²; JE-Y(St)2Y 2x2x0.8 mm²; 2 x 0.5 mm² RF COMMUNICATION RF band : 868,3 MHz Transceiver (integrated in the antenna) The external HRA80 includes the transceiver used for HCE80 and HCE80R HCC80 and HCC80R includes the antenna and transceiver on the circuit board Receiver class : 2 RF communication range : 30m in a residential building environment RF communication Technology : short, high rate transmission to minimize air time and avoid collisions ENVIRONMENTAL and STANDARDS Mounting Measurements (WxHxD) Protection class : IP 30 : Wall mounting or DIN track : 350 x 52 x 82 mm Operating temperature : 0 +50 C Storage temperature : -20...+70 C Relative humidity : max. 5 93 % Fire protection class : 0 Authorization : C

Internal antenna of HCC80 Malfunction LED Installation LED Function button Potential afflicted Installation button Safety fuse 1 = Bus (+) 2 = Bus (-) for external antenna 3 = Input heating / cooling 4 = Mass for heating / cooling 5 = Analogue output (TW) 6 = Analogue output (mass)

Wiring connections Example Voltage supply Switch-over contact Heating/Cooling Analogue feedback 1 = (+) Bus for external antenna 2 = (-) Bus for external antenna 3 = Input heating / cooling 4 = Mass for heating / cooling 5 = Analogue output (TW) 6 = Analogue output (mass) 1 + 6 = Ground wire (PE) 3 + 8 = Neutral wire (N) 4 + 9 = Phase (L) 5 + 10 = Pump outlet (220 V) HRA80 Heating Cooling Boiler feedback

APPLICATION EXAMPLES Application A Underfloor heating with and without time program. The room unit CM67z can control up to 2 zones with individual time program. Only the zone 1 of the CM67z includes the room sensor for zone 2 the HCF82 must be additional allocated for the room temperature measurement to the same zone of the underfloor heating controller. The HCW82 is sending the room temperature and setpoint offset to the allocated zones without time program. Communication 868,3 MHZ CM67z Up to 8 zones HCF 82 HCW 82 HRA80 Antenna for HCE80 HCE80R Pump control Underfloor heating controller HCE80/HCE80R/HCC80/HCC80R Automation and Control Solutions Honeywell AG Boeblinger Strasse 17 D-71101 Schoenaich Phone: (49) 7031 63701 Fax: (49) 7031 637493 http://europe.hbc.honeywell.com Subject to change without notice. Printed in Germany Manufacturing location certified to

Application B Underfloor heating and radiator control Communication 868MHZ HCW 82 HCF 82 CM67z HCM200D HRA80 Setpoint HC60NG R6660D Setpoint Room temp. HR80 Pump control Underfloor heating controller HCE80/HCE80R/HCC80/HCC80R Analogue Boiler feedback OTC controller MCR/Panther/Smile (HCE80/HCC80) only Boiler feedback relay potential free contact 42V (HCE80R/HCC80R) only Thermal actuator up 24 (MT4-230) Change over contact heating/cooling Automation and Control Solutions Honeywell AG Boeblinger Strasse 17 D-71101 Schoenaich Phone: (49) 7031 63701 Fax: (49) 7031 637493 http://europe.hbc.honeywell.com Subject to change without notice. Printed in Germany Manufacturing location certified to