EnergyCap Brochure. Updated: 5/11.

Similar documents
Roofing System Solutions Brochure

TOPCOAT Brochure. Updated: 12/09

FAST FACTS ADVANTAGES OF MULTI PLY BUILT-UP ROOFING. Asphalt Roofing Manufacturers Association

Firestone Warranty Program

California s Title 24 For Low-Slope Roofs. Building Energy Efficiency Standards

Firestone Modified Bitumen Roofing Systems DURABLE. RELIABLE. SUSTAINABLE

Commercial Full Line Brochure

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.

CoolRoofingSolutions from The Cool Roofing Experts!

Jm Tpo systems Single Ply Roofing

Best Practices in Roof Design: Sustainable Energy Efficient Reroofing

BITUMINOUS ROOF COATINGS, CEMENTS, PRIMERS AND ADHESIVES

CARLISLE S. c a r l i s l e - s y n t e c. c o m

Proven roofing SyStemS

Roofing Retrofits: Focus on Sustainability

THE EFFECT OF REFLECTIVE ROOF COATINGS ON THE DURABILITY OF ROOF SYSTEMS

Mop it. Stick it. Spread it.

GAF HydroStop Brochure

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

PRODUCT CONTROL SECTION

FEFPA 2015 SUMMER CONFERENCE. Energy Effectiveness through Roof Coatings and Solar

tamko.com RESIDENTIAL ROOFING PRODUCT GUIDE

The Expanding Role of the Roof in a Sustainable World. Dr. James L. Hoff Research Director Center for Environmental Innovation in Roofing

CHAPTER 7: Building Systems ROOFING SYSTEMS

Commercial Roof Systems Selection Guide

City of Houston Code Enforcement COOL ROOF CODE


Membrane Roofing. Advances in Membrane Roofing

CREEK Technical Services, LLC

TARRANT COUNTY DETAIL STANDARDS

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

COMMERCIAL & LOW SLOPED ROOF SPECIALISTS TOTAL NDL SYSTEM MANUFACTURER WARRANTIES

JM s Commitment to Meeting Your Single Ply Roofing Needs. JM PVC with DuPont Elvaloy KEE (Ketone Ethylene Ester) Single Ply Systems

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER POLYSOCYANURATE SYSTEM DESCRIPTION TORCH SYSTEM OVER POLYISO (15,17,19 YR) TH/BS-TH/CS

Cool Metal Roofing An Emerging Hot Topic Scott Kriner The Metal Initiative

Timberline Lifetime High Definition Shingles Brochure

CertainTeed. Roofing Products. California OOL. Understanding Part 6 of Title 24, California Building Standards Code

RAMP Energy Efficiency

CARLISLE S ROOFING SYSTEMS EPDM TPO PVC FLEECEBACK ROOF GARDEN

HEB 38 BLANCO AND WEST AVENUE FLUID APPLIED EPDM RUBBER ROOF RECOVERY SYSTEM APPLICATION

HOT ASPHALT BUILT-UP ROOFING SYSTEMS MORE LAYERS MEANS MORE PROTECTION

Prices Effective April 1, 2016

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

ENERGY STAR Cool Roof Technology and Impact Resistance

tamko.com RESIDENTIAL ROOFING PRODUCT GUIDE

THE ROOFPOINT ENERGY AND CARBON CALCULATOR A NEW MODELING TOOL FOR ROOFING PROFESSIONALS

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

COMMERCIAL BUILDING APPLICATIONS

Sun-Activ - reflective SBS membrane. Sun-Activ - White reflective bituminous waterproofing membrane for Cool Roof

SBS-Modified Bitumen Roof Systems

August 16, Rebecca Duff ICF Interna tional 9300 Lee Highway Fairfax, VA Re: ENERGY STAR Version 2.0 Final Draft. Dear Ms.

GAF Liquid-Applied Roof Membrane Brochure

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER

Roof Restoration System. For building owners, property management firms and facility managers. seamless possibilities

ROOF CONSTRUCTION SCIENCE (METCT092)

EPDM. Roofing systems

!!! !!!! !!! !!! !!! !!! !!!!!!!!! Table of Contents! Section 1: Most Common Types of Flat Roofing! Section 2: Better Understand Your Flat Roof!

Table of Contents. Dedicated to Service and Support

Preliminary Analysis of Energy Consumption For Cool Roofing Measures

Energy, Environment and Roofing Engineering

Accelerated aging of roofing surfaces

CertainTeed. Impact Resistant. Shingles. Shown in Landmark IR Weathered Wood. Est.1665

Clear Fork Valley Local School District. Roofing Repairs Spring/Summer 2015

COMMERCIAL ROOFING. Learning Objectives. Commercial Roofing Fundamentals May 2, 2012

Specifying SPF Roofing Systems

Table of Contents. To access data on JM Roofing Systems, visit our Web site at

PVC ROOFING SYSTEMS BUILDING SOLUTIONS A SINGLE SOURCE FOR SINGLE-PLY ROOFING

The Right Team. Proven Roofing Solutions.

DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION

Fluid-Applied Roofing for Repair and Renovation FACILITIES & MAINTENANCE PRIVATE UNIVERSITY PRODUCTS AND NEWS JULY 2015

Certificate of Compliance ENV-1-C and Envelope Component Method ENV-2-C

This article examines the quality

Materials and Colors

Peel & Seal Self-Stick Roofing Solutions

Get Rid of Roof Problems for Good. How spray foam roofing can protect your building and make you money

THERMOTEK SELF ADHESIVE MEMBRANE +G2 OVER WOOD SYSTEM DESCRIPTION SELF ADHESIVE OVER WOOD (8YR) BS-SA/CS

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

Steel Fire Sprinkler Pipe

ENERGY STAR Program Requirements for Roof Products. Partner Commitments

Achieving Maximum Roof Performance at the Lowest Installed Cost With Invinsa Roof Board

Asphalt Continues to be America s Most Popular Roofing Material.

ROXUL COMMERCIAL ROOFING. Understanding Climate Requirements That Drive Performance. roxul.com

C e r t a i n Te e d S e l e c t i o n G u i d e

UPDATE October 8, 2012 Chicago Roofing Contractors Association CHICAGOLAND S ROOFING, INSULATION, AIR-BARRIER REQUIREMENTS

CERTIFICATE OF COMPLIANCE Prescriptive Residential Re-roof Project Name:

Roofing Systems. New Applications / Re-Roofing / Maintenance

Baumann Crace Meyer Salazar

MASTICS. 275 Centre St., Unit 15 Holbrook, MA (617) Shedd Rd. Middlefield, OH (440)

CertainTeed SOLAR. Solar From A Proven Source

Please read the entire document before purchasing and installing any of these products

Roof Systems Overview

How To Design A Sustainable Roofing

Commercial Roof Systems

What makes DECRA Roofing Systems unique?

GAF Green Building Playbook Using GAF Products on LEED Projects

BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION

Roof Inspection and Evaluation

By James L. Hoff. Cool Roofing Symposium Hyatt Regency Hotel Atlanta, Georgia May, 2005

FEATURING THE GOLD & PLATINUM COLLECTION

Transcription:

EnergyCap Brochure Updated: 5/11 www.gaf.com

The safety of multi-ply roofing systems...with ENERGY STAR Savings!

Now, Get The Safety Of RUBEROID MB And GAFGLAS BUR Multi-ply Roofing Systems With ENERGY STAR Savings Think Green... Save Energy Energy costs are skyrocketing... and demand is at an all-time high. Wasting energy is not just irresponsible it s bad business! Until now, property owners who wanted an energy-saving roof were limited to: Installing a single-ply (TPO or PVC) roof or... Adding a roof coating to their asphaltic system, often at considerable additional expense. But now, there s EnergyCap brilliant white cap sheets! They combine the proven performance of GAF s commercial asphaltic cap sheets with a factoryapplied layer of TOPCOAT EnergyCote roof coating in a single roof membrane. Multi-ply systems using EnergyCap cap sheets are the safer solution for meeting ENERGY STAR or Title 24 requirements and are less expensive to install than other white roofing options. EnergyCap brilliant white cap sheets have nearly 3 times the reflectivity of standard white cap sheets! EnergyCap brilliant white cap sheet Standard white cap sheet EnergyCap Systems are Up To 45% Less Costly To Install Than Other ENERGY STAR Qualified Roofing Systems... Typical Installed Cost New SBS system with post-applied white coating New BUR system with post-applied white coating New EnergyCap SBS system New, white TPO system New EnergyCap BUR system EnergyCap systems are typically less expensive to install than other ENERGY STAR qualified roofing solutions such as PVC or TPO... and you get the proven safety and reliability of multi-ply roofing! * Installed cost estimates are based on 1,000 square systems in California. Modified bitumen and BUR systems include insulation, 2 plies of GAFGLAS Ply 4 ply sheets, and cap sheet (as compared to same systems with Topcoat MB Plus coating applied post-membrane application). TPO mechanically-attached insulated systems were compared to EnergyCap BUR.

EnergyCap Systems Reduce Your Ongoing Energy Costs, Year After Year... Total Estimated Energy Savings Of A 500 Square EnergyCap Roof Over 15 Years* (Based On Data From Oak Ridge National Laboratory, U.S. Dept. Of Energy) Sacramento, CA $60,000 Houston, TX $43,500 Chicago, IL $10,500 New York City, NY $43,500 Miami, Fl $63,000 EnergyCap brilliant-white cap sheets exceed the minimum reflectivity requirements for ENERGY STAR as well as the reflectivity and emissivity of Title 24 to save you money (visit www.gaf.com and calculate how much you can save!). * Energy savings estimates are based on energy and fuel cost data provided by ORNL web site at the time of print and does not take into consideration energy cost fluctuations over time. Assumptions used in the savings calculations include: R-value of 19.0; infrared emittance of 84%; COP of 2; solar reflectance of 80%; average heating system efficiency. The results are examples type of building, geographical locations, your exact energy/fuel costs as well as other factors must be considered for your specific situation. EnergyCap Systems Save Labor And Reduce Installation Hassles For Property Owners! Saves Labor! Pre-Applied Brilliant White Coating Premium TOPCOAT EnergyCote white elastomeric coating saves time and labor (compared to applying the coating after the membrane has been installed). Reduces Labor Cost by over 25% when compared to site-applied coatings. Reduces Installation Hassles For Property Owners! NO 90-Day Waiting Period to complete the project. NO Worries about damage caused by coating overspray. NO Need for multiple coats. NO Staging of solvent-based coatings. NO Long Wait for water-based coatings to dry. NO Need to worry about proper coating thickness. Contractor Friendly! Accurate Installation, Less Waste Factory-installed coating eliminates the need to measure and gauge coating application. Fewer Return Trips If touch-up is needed TOPCOAT EnergyCote coating can be applied immediately. No Additional Staging Of Materials after roof is installed. Versatile Available in BUR for hot-mopped applications; SBS for hot-mopped, cold-applied, or heat-welded applications; or APP for torch applications. No Waiting Roof top maintenance traffic can begin immediately after EnergyCap membrane is installed. Less Clean Up No tracking of wet coating over the membrane or property.

EnergyCap... The Green Roof That s White Now With Six Great Choices! 1- EnergyCap BUR Roll length... 32.6 ft (9.9 m) Roll width... 39.375 in (1.0 m) Roll size... 1 sq. (106.9 gross ft 2 or 9.9 m 2 ) Meets ASTM D3909, ASTM E903, Reflectivity: 80%* Emissivity: 0.90* SRI: 100* 2- EnergyCap SBS 30 FR (glass mat): Roll length........ 33.7 ft (10.27 m) Roll width........ 39.375 in (1.0 m) Roll size......... 1 sq. (110.5 gross ft 2 or 10.27 m 2 ) Meets ASTM D6163, Type 1, Grade G, ASTM E903, Reflectivity: 80%* Emissivity: 0.84* SRI: 99* 3- EnergyCap Torch Plus FR (polyester mat): Roll length... 32.4 ft (10.3 m) Roll width... 39.5 in (1.0 m) Roll size... 1 sq. (106.7 gross ft 2 or 9.9 m 2 ) Meets ASTM D6222, Type 2, Grade G, ASTM E903, Reflectivity: 80%* Emissivity: 0.84* SRI: 99* 4- EnergyCap Torch Granule FR (polyester mat): Roll length... 32.4 ft (9.9 m) Roll width... 39.625 in (1.0 m) Roll size... 1 sq. (106.9 gross ft 2 or 9.9 m 2 ) Meets ASTM D6222, Type 1, Grade G, ASTM E903, Reflectivity: 84%* Emissivity: 0.81* SRI: 104* For complete, up-to-date specifications and information, visit www.gaf.com Product Specifications (nom.) 5- EnergyCap SBS Heat-Weld Plus FR (polyester mat): Roll length........ 32.75 ft (9.98 m) Roll width........ 39.625 in (1.0 m) Roll size......... 1 sq. (108.1 gross ft 2 or 10.04 m 2 ) Meets ASTM D6164, Type 1 & 2 Grade G, ASTM E903, Reflectivity: 75%* Emissivity: 0.82* SRI: 91* 6- EnergyCap Mop FR (polyester mat): Roll length... 32.56 ft (9.92 m) Roll width... 39.625 in (1.0 m) Roll size... 1 sq. (107.52 gross ft 2 or 9.99 m 2 ) Meets ASTM D6164, Type 2 Grade G, ASTM E903, Reflectivity: 73%* Emissivity: 0.83* SRI: 89* Applicable Standards UL Classified for use in the construction of Class A, B, or C roofs ENERGY STAR Compliant Approved for use in LEED certified projects State of Florida Approved** Miami Dade County Approved** FM Approved Title 24 compliant CRRC Listed ICC ESR-1274 *Values reported are initial values. **See specific product data sheets. An Important Note about LEED and Emissivity Values... Different test methods may yield different value results. In accordance with LEED required testing methods, EnergyCap 30 FR and Torch Granule Plus FR achieved an emissivity value of.90 when tested to ASTM E408. The above results were reported to CRRC and were tested in accordance with ASTM C1549. The emittance and reflectance values published are those required for Title 24 compliance. For additional information on this or any other technical matter please call Technical Services at 1-800-766-3411. Note: Initial reflectivity value may be reduced over time as a natural consequence of aging. East Sales Office: (856) 241-0241 Central Sales Office: (630) 296-1980 Southeast Sales Office: (813) 829-8867 Southwest Sales Office: (972) 851-0500 West Sales Office: (951) 360-4200 2011 GAF 5/11 #515 1361 Alps Road, Wayne, NJ 07470 COMES100 Contractor Services 800.ROOF.411 (800.766.3411) 85535-1206