Parallel Application Guidelines



Similar documents
POLICY BULLETIN Tecumseh Compressor Company Compressor Group

Why and How we Use Capacity Control

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Engineering Recommendation on: Accumulators Revised Issued January 10, 1979 Page 1 of 7

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL)

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

Table Z. Troubleshooting Chart for Air Conditioners. Cause

AE R6 December Digital Capacity Control for Copeland Scroll Refrigeration Compressors AE R6

marine/bespoke split applications

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

Compressors, Chillers & Condensers

Tube Size and Component Selection

Transcritical CO2 booster system How to control the system

DEFROSTING. Service Engineers Section Technical Bulletin No 3

How Ground/Water Source Heat Pumps Work

TRAINING, EXAMINATION AND CERTIFICATION

DESIGN STANDARDS SECTION

INSTALLATION INSTRUCTIONS HOT GAS BYPASS SYSTEM DESIGN MANUAL

Application Engineering

Chapter 2 P-H Diagram Refrigeration Cycle Analysis & Refrigerant Flow Diagram

Rotary Compressors RK, RG and HG

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Water valves REFRIGERATION AND AIR CONDITIONING. Fitters notes

System Trouble Shooting Fault Location REFRIGERATION AND AIR CONDITIONING. Fitters notes

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

PACKAGE AIR CONDITIONERS REPLACEMENT PARTS MANUAL

A/C refrigerant system, overview

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

D A T A S H E E T. TX6 Thermo Expansion Valves. Alco Controls TX6. Features. Introduction. Construction

Refrigeration Basics 101. By: Eric Nelson

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Steam System Best Practices Condensate System Piping

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Automobile Air Conditioning Primer

SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

Intelligent control system with integrated electronic expansion valves in an air-conditioning system operating at a Telecom telephone exchange

Flushing and Cleaning the A/C System

Air Conditioning 101. STN Presentation AC101

How To Clean Water From An Ammonia Refrigeration System

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

How To Understand Evaporator

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

REGULATING VALVE APPLICATIONS

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Skills Canada National Competition Instructions and Competition Details 38 Refrigeration and Air Conditioning / Post - Secondary May 27-30,

Thermal Coupling Of Cooling and Heating Systems

Holdover Plates Transport Refrigeration Systems

Basic Technology Series

8. Refrigeration. 4. Liquid. Refrigerant. 4. Liquid Refrigerant. Figure 8.1 Refrigeration system layout (single stage)

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29

ON-VEHICLE INSPECTION

New Trends in the Field of Automobile Air Conditioning

Heating Water by Direct Steam Injection

Solenoid Valves and Their Importance in Refrigeration Systems. October 2007

Cool Design for Homes and Offices

NSN

Technical Information

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS


National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Basic Hydraulics and Pneumatics

1 DESCRIPTION OF THE APPLIANCE

The Secret of Hydraulic Schematics. BTPHydraulics

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

How To Design A Refrigeration System

On request of Akzo Nobel Dynamo Project Team we ve surveyed the energy efficiency of the compressed air system in the Barcelona Deco & A/AS plant.

Refrigerated. Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

BB-18 Black Body High Vacuum System Technical Description

HOW HVAC WORKS. How HVAC. Works PAGE 1

Heat. Investigating the function of the expansion valve of the heat pump. LD Physics Leaflets P Thermodynamic cycle Heat pump

Refrigerated Design Texas

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

Characteristics of Evaporators

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

2A.1 Features of Chiller Control Components A.3 Chilled-Water Supply Temperature Control A.4 Cooling-Water Supply Control...

National Grid Small Business Energy Efficiency Program Overview. Central New York Energy Expo March 30, 2010

Variable Capacity Compressors, a new dimension for refrigeration engineers to explore

MP-4000 Alarm List (Software version or later)

Example. Fluid Power. Circuits

Saving energy by solar collector and heat pump combination in hot water production in residential and hotel sectors

MAC-120HE-01 Air-Cooled Chiller

ice 3 FLUID TO FLUID HEAT PUMP

SECTION AIR COOLED WATER CHILLERS

STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE

Hydraulic Trouble Shooting

Dry-out Design Considerations and Practices for Cryogenic Gas Plants

CARING FOR YOUR WATER HEATER

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

Electronically Controlled Clutchless or Variable Drive Compressors

Refrigerant Changeover Guidelines HCFC R-22 to HFC R-404A/R-507. Leading the Industry with Environmentally Responsible Refrigerant Solutions

MINNESOTA WEST COMMUNITY & TECHNICAL COLLEGE COURSE OUTLINE

Transcription:

Commercial Compressors Parallel Application Guidelines Expect more from us

1. INTRODUCTION..................... 3 2. OIL EQUALIZATION................... 3 2.1 Oil equalization line system....... 4 2.1.1 Individual oil separator.......... 5 2.1.2 Common oil separator.......... 5 2.2 Oil level regulator system........ 6 2.2.1 Individual oil level regulators with individual oil separators...... 6 2.2.2 Individual oil level regulators with common oil separator....... 7 3. SUCTION AND DISCHARGE LINES..... 8 3.1 Suction line.................... 8 3.2 Suction header................. 9 3.3 Discharge header.............. 10 4 COMPRESSOR CONTROL SEQUENCE.11 5. SYSTEM COMPONENTS.............. 12 5.1 Suction line accumulator........ 12 5.2 Suction filter.................. 12 5.3 Crankcase heater.............. 12 5.4 Thermostatic expansion valve.... 12 5.5 Condensing pressure control.... 12 6. INSTALLATION AND SERVICE......... 13 6.1 Compressor mounting.......... 13 6.2 Rotation direction............. 13 6.3 Total capacity and application envelope............ 13 6.4 Pressure switch settings......... 13 6.5 Failure analysis................ 13 7. MANEUROP COMPRESSOR CHARACTERISTICS...................14 7.1 Oil level regulator and oil sight glass.............. 14 7.2 Oil equalization connection...... 14 Parallel Application 2

1. INTRODUCTION A parallel compressor installation refers to a system of compressors interconnected and working together.though several benefits exist for parallel installation, the primary reason is reduced operating cost through greater control of capacity and power consumption.this is achieved by staggering compressor switch-on sequences that allow the parallel system to match its power with the capacity needed. The following sections will provide detailed information for installation and operation of parallel compressor installations: 2: Oil Equalization systems and their particularities. 3: Suction and Discharge Lines of parallel compressors. 4: Compressor Switch Sequence of compressors in parallel. 5: Additional information about System Components. 6: Installation and Service requirements. 7: Maneurop Compressor Characteristics. The number of compressors in a parallel system along with specific operational needs varies greatly from operation to operation. That is why the information contained in this leaflet provides a generalized overview only. For more specific details pertaining to individual needs please contact your local Danfoss application engineering support team. Note: To ensure proper parallel installation and running conditions, the following recommendations must be followed: It is essential to respect all instructions given in this document, the installation instruction leaflet delivered with every compressor, and the compressor s Selection & Application Guidelines. This application guideline concerns single stage parallel systems for reciprocating compressors only. It is not valid for two-stage or cascade systems (or so-called booster systems) which require more specific installation precautions. For additional system components (i.e. oil level regulator, oil separator, etc.), the supplier recommendations must always be respected. 2. OIL EQUALIZATION Oil equalization is one of the most critical aspects in parallel installations. Oil returning from the system must be controlled otherwise improper oil amounts will flow to and damage compressors.therefore, to achieve equal oil distribution between all compressors, the two most popular solutions are: Oil equalization line system. This economical system for oil equalization connects the compressors crankcases via an oil line.the oil equalization line system should be used for installations of no more than 3 compressors of the same size / capacity. Oil level regulator system. This more complex system provides stable, predictable oil management under nearly all circumstances.an oil level regulator is mounted on each individual compressor and is fed oil via an oil separator in the discharge gas line.the oil level regulator system should automatically be used for installations of 4 or more compressors. 3 Parallel Application RECIPROCATING COMPRESSORS

2.1 Oil equalization line system This system insures oil supply and oil equalization in all compressor crankcases through the oil equalization connections. For this system it is important that the crankcase pressure (suction pressure) in all compressors is equal. If this is not the case uneven oil distribution will occur. If no precautions are taken, the internal suction pressure of parallel compressors may vary. These variations, though small, can create considerable differences in oil levels. Example, a pressure difference of 0.001 bar causes an oil level difference of 1.1 cm. The following points are guidelines for proper installation of oil line equalization systems. Please refer to figure 2.1: The oil equalization line must be installed in the horizontal plane. The oil equalization lines should never rise above the horizontal plane of the oil equalization connections. Oil equalization lines between the compressors must be flexible.the use of vibration absorbers may be required in some cases. The oil equalization line diameter must be 3/8. If a smaller oil equalization line is used, oil flow will be restricted. If a larger oil equalization line Figure 2.1 Example of correctly mounted oil equalization line system. Note all compressors are of equal size/capacity and mounted on the same level. is used, cold suction gas is allowed to circulate just above the oil level.this cold suction gas will condense inside idle compressors and in time dangerous amounts of liquid refrigerant will build up. The oil sight glass must never be used in place of the oil equalization connection. Only ball valves are allowed in the oil equalization lines to provide compressor isolation capability.the use of other valves, such as rotolock valves, may create undesirable pressure drops. In parallel installations an oil separator is strongly recommended. In parallel installations with either long pipelines, multiple condensers or multiple evaporators an oil separator is required. In an installation having multiple oil traps, an oil separator, or the possibility of slow oil return an oil reservoir is often required. The two most common methods for oil separation, which will be explained in detail, are the following: Individual oil separator Common oil separator Parallel Application 4

Oil separator NRV Shut off valve Sight glass Vibration absorber Figure 2.2 Individual oil separators. 2.1.1 Individual oil separator The individual oil separator method allows for each compressor to have its own oil separator. These separators return oil directly to each compressor s oil equalisation port (see figure 2.2). Note: The size of the discharge line between compressor and oil separator must never be smaller than the rotolock discharge port. Remark: If an oil separator malfunction occurs, oil distribution and balanced oil levels will be strongly affected. 2.1.2 Common oil separator The common oil separator method allows for one oil separator to be used by the entire system.the oil is fed into the compressors via the suction line, though it should be noted that the oil return tube must intercept the suction line at least one meter before the suction header (see figure 2.3 page 6). If oil separator floating valve leakage occurs, a hot gas bypass can be avoided by the use of an oil injection sequence. This injection sequence, through a normally closed solenoid valve located in the oil return line, is recommended 5 seconds for every 10 minutes of run time. In either the individual oil separator method or the common oil separator method, be sure to add an additional amount of oil for reliable operation.the amount of extra oil needed is indicated in the oil separator s instructions. It is also good practice to fit an oil filter in the oil return line. 5 Parallel Application

From the oil separator Suction tube To the suction header Suction tube To the compressor Discharge gas Oil separator Oil return NRV Vibration absorber Figure 2.3 Common oil separator 2.2 Oil level regulator system If a parallel system consists of 4 or more compressors, compressors of different size/capacity, or if the quantity of oil return from the system is in question, oil level regulators in combination with an oil separator must be used. Under these conditions the crankcase pressure difference will not influence the oil equalization level. The oil level regulator must be mounted on the compressor oil sight glass connection. Oil is trapped in the oil separator. From the oil separator it flows to the oil reservoir. From the oil reservoir it flows to the oil regulator before entering the compressor. For proper flow, the oil reservoir must maintain a higher pressure than the suction pressure (standard difference is 1.4 bar). The two most common methods of oil level regulators, which will be explained in detail, are the following: Individual oil level regulators with individual oil separators Individual oil level regulators with common oil separator 2.2.1 Individual oil level regulators with individual oil separators This method introduces one oil separator and one oil level regulator for every compressor. The oil separator feeds the oil level regulator that in turn feeds the compressor. Refer to 2.1.1 for information regarding individual oil separators. Parallel Application 6

Pressure differential valve To suction header Oil receiver From oil separator Shut off valve Sight glass Oil level regulator Filter Figure 2.4 Individual oil level regulators with common oil separator 2.2.2 Individual oil level regulators with common oil separator This method introduces one oil separator for the system and one oil level regulator for each compressor.the common oil separator feeds the individual oil level regulators that in turn feed the compressors. Oil separator selection must be made regarding the capacity range of the parallel system to ensure a proper oil separation at both part load and full load. See figure 2.4 for a detailed drawing of a correctly assembled example of this system. Always be sure your selected method is in accordance with the manufacturer recommendations. When the parallel system is installed in cold ambient the oil separator must be insulated to avoid efficiency losses and refrigerant liquid condensation during off cycle periods.a check valve (Danfoss NRV) located in the discharge line after the oil separator can reduce such a risk. In some situations, separator heating may be required. 7 Parallel Application