Tracking retro-reflective sensor for bottles and tape. Dimensioned drawing



Similar documents
Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Electrical connection

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

W150: Miniature photoelectric switch series with completely integrated electronics

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

photoelectric highlights

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Measuring Sensors PRODUCT DESCRIPTION

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

W 27-2: The photoelectric switch series with expanded possibilities

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

intelligent solutions

LUT Luminescence scanners: Seeing what no-one else can

Cross-beam scanning system to detect slim objects. 100 mm in

W 260: Standard photoelectric switch series for a broad range of applications

W 18-3: Incorporated application Know-how, expanded functionality, high level of equipment availability

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

BOS 73K... BOS 74K...

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Smart Sensing Solutions Since 1954

Universal Voltage Terminal Photoelectric E3JM

Color Mark Sensor with Red or Green LED E3S-VS

Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option

MINI MCR-SL-R-UI(-SP)

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Barcode Reader Series BCL 31, BCL 32, BCL 34

CONFIGURABLE SAFETY RELAYS

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Safety Relays ESM/ESM-F

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

W 36: Mastering complex tasks reliably

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

technical data (according to IEC )

crm+25/d/tc/e Extract from our online catalogue: Current to:

Instruction Manual Service Program ULTRA-PROG-IR

crm+130/iu/tc/e Extract from our online catalogue: Current to:

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

is then retained absolutely without interruption.

W 160: Miniature series for optimum solutions

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Operating instructions Optical distance sensor O1D100 O1D / / 2012

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

How To Make An Ultrasonic Sensor

W 2: Subminiature photoelectric switch series: extremely small and extremely strong

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Barcode positioning systems BPS 8, BPS 34/37 Innovations that truly move you forwards.

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

W160T: With the smallest LED light spot

Adjustment functions for both span and shift have been incorporated

MULTI-BEAM LS10 Light Screen System

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2010

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Inductive sensor NI10-M18-Y1X-H1141

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

CONFIGURABLE SAFETY RELAYS

Combi switchbox with integrated 3/2 way pilot valve

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Safety technique. Emergency stop module BO 5988 safemaster

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Digital display DA 48

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Preset Counter signo 721

Duct Humidity Transmitter

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Inductive Proximity Sensors

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Multifunction devices

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Electric Rotary Actuator - On/Off or programmable control actuator

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Modular I/O System Analog and Digital Interface Modules

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity

Electronic Pressure Switch EDS 300

Cable Plug acc. to DIN EN , Form A

PHOENIX CONTACT Features

Tube Liquid Sensor OPB350 / OCB350 Series

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Color sensors CS8, CS8-1

Magnetic proximity switches

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

Electronic Pressure Switch EDS 3000

SPECTRO Series SPECTRO-3-FIO-JR. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (cf. p )

Transcription:

Tracking retro-reflective sensor for bottles and tape Dimensioned drawing en 01-2015/11 50130113 0 3.6m 1,5 khz We reserve the right to make changes DS_PRK18BTT3LP_en_50130113.fm Retro-reflective photoelectric sensors with autocollimation optics for reliable detection of highly transparent bottles and tape Sensitivity adjustment via teach button Sensitivity adjustment from control via IO-Link interface Comprehensive diagnostic options via IO-Link interface Button locking Temperature compensation ±20 C Automatic contamination compensation (tracking function) for longer intervals between cleanings 10-30 V DC IEC 60947... IEC 60947... Accessories: (available separately) IP 69K IP 67 U L US C LISTED Mounting system (BTU 200, BT 95) M12 connection technology (K-D M12) Reflectors (TK, MTK) Reflective tape (REF) Deflecting mirrors (US18B) IO-Link master set SET MD12-US2-IL1.1 + accessories - diagnostics set (part no. 50121098) A Display B Teach button C Optical axis D Optical accuracy E Reference plane for D Electrical connection Pin 1 Pin 2 Pin 3 Pin 4 PRK18B.TT3/LP-M12 + PNP dark 1) GND IO-Link / SIO 1) Factory setting; function configurable via IO-Link. Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 info@leuze.com www.leuze.com PRK18B.TT3/LP-M12-01

Specifications Optical data Typ. op. range limit (TK(S) 100x100) 1) 0 3.6m Operating ranges 2) see tables Light source 3) (modulated light) Wavelength 620nm (visible red light) Optical accuracy type dependent (see order guide) Sensor operating modes IO-Link COM2 (38.1kBaud, Frame 2.5, Vers. 1.1, min. cycle time 2.3 ms) SIO is supported Configuration direct configuration / system commands; attention: data storage is not supported! Timing Switching frequency 1500Hz Response time 0.333ms Jitter time 110μs Readiness delay < 300ms Electrical data Operating voltage UB 4) 10 30VDC (incl. residual ripple) Residual ripple 15% of UB Open-circuit current 18mA Switching outputs/functions /LP pin 2: 1 PNP switching output, dark switching pin 4: IO-Link data, in SIO push-pull mode 5) Signal voltage high/low (UB-2V)/ 2V Output current max. 100mA Sensitivity adjustable via teach button (see IO-Link service data) Indicators Green ready Yellow light path free Yellow/green, flashing synchronously error (9Hz) Mechanical data Housing 6) diecast zinc, chemically nickel-plated Connector diecast zinc, chemically nickel-plated Optics glass Operation teach button Weight approx. 60g Connection type M12 connector, 4-pin Environmental data Ambient temp. (operation/storage) -40 C +60 C/-40 C +70 C Protective circuit 7) 2, 3 VDE safety class 8) III Degree of protection IP67, IP 69K Light source exempt group (in acc. with EN 62471) Standards applied IEC 60947-5-2 Certifications UL 508, C22.2 No.14-13 4) 9) Chemical resistance tested in accordance with ECOLAB Options Via teach button: Teach-in, activate/deactivate tracking function, Easy Tune (after activating via IO-Link). Via IO-Link: Teach-in, teach button lock, autocontrol warning message for signaling low function reserve (counting principle), light/dark changeover, tracking function on/off, function of switching output Q2 (pin 2), configurable time functions. 1) Typ. operating range limit: max. attainable range without function reserve 2) Operating range: recommended range with function reserve 3) Average life expectancy 100,000h at an ambient temperature of 25 C 4) For UL applications: use is permitted exclusively in Class 2 circuits according to NEC 5) The push-pull switching outputs must not be connected in parallel 6) Color changes due to cleaning agents do not adversely affect the coating 7) 2=polarity reversal protection, 3=short circuit protection for all transistor outputs 8) Rating voltage 50V 9) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.24A min, in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7) Order guide The sensors listed here are preferred types; current information at www.leuze.com. Description Product name Part no. Tracking retro-reflective photoelectric sensor for highly transparent bottles and tape, tracking function, teach button, IO-Link interface, 4-pin M12 connector PRK18B.TT3/LP-M12 50121230 Tables Reflectors TK TKS Tape 6 = adhesive = screw type = adhesive Operating range 1 TK(S) 100x100 0 3.0m 2 MTKS 50x50.1 0 2.8m 3 TK(S) 40x60 0 2.5m 4 TK(S) 30x50 0 1.1m 5 TK(S) 20x40 0 1.1m 6 Tape6 50x50 0 1.0m 1 0 3.0 3.6 2 0 2.8 3.3 3 0 2.5 3.0 4 0 1.1 1.3 5 0 1.1 1.3 6 0 1.0 1.2 Operating range [m] Typ. operating range limit [m] Diagrams Gap size y [mm] Min. object gap for tracking with MTKS 50x50.1 at 400mm 10 9 A B 8 C 7 6 5 4 3 2 1 0 0 100 200 300 400 Distance x (sensor to object) [mm] A 11% sensor sensitivity B 18% sensor sensitivity C 100% sensor sensitivity x Remarks y Operate in accordance with intended use! This product is not a safety sensor and is not intended as personnel protection. The product may only be put into operation by competent persons. Only use the product in accordance with the intended use. UL REQUIREMENTS Enclosure Type Rating: Type 1 For Use in NFPA 79 Applications only. Adapters providing field wiring means are available from the manufacturer. Refer to manufacturers information. CAUTION the use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. ATTENTION! Si d'autres dispositifs d'alignement que ceux préconisés ici sont utilisés ou s'il est procédé autrement qu'indiqué, cela peut entraîner une exposition à des rayonnements et un danger pour les personnes. Reflectors; The light spot may not extend beyond the reflector. Preferably use MTK(S) reflectors or reflective tape 6. PRK18B.TT3/LP-M12-01 2015/11

Tracking retro-reflective sensor for bottles and tape Part number code P R K 1 8 B. F X T T 3 / 4 P - M 1 2 Operating principle PRK Retro-reflective photoelectric sensor for bottles RK Retro-reflective photoelectric sensor for tape (Function against any reflective tapes and glass triple reflectors) Series 18B 18B series Timing F High speed Standard Optical accuracy X Optical axis aligned, shift angle < ±0.25 Standard Detection properties T Setting of 11% is possible Setting of 11% is not possible Tracking function available T 1) Tracking function/contamination compensation No tracking function Setting 1 270 potentiometer 2 11-turn potentiometer 3 Teach button No setting Pin assignment of connector pin 4 / black cable wire 2 NPN, light switching N NPN, dark switching 4 PNP, light switching P PNP, dark switching L IO-Link Pin assignment of connector pin 2 / white cable wire X 2 NPN, light switching N NPN, dark switching 4 PNP, light switching P PNP, dark switching T Teach input Connection technology M12 M12 connector, 4-pin 6000 Cable 6m 1) Only possible in conjunction with the detection property "T". Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 PRK18B.TT3/LP-M12-01 info@leuze.com www.leuze.com

IO-Link process data Output data device Data bit Assignment Meaning 7 6 5 4 3 2 1 0 Switching output Q1 0 = inactive, 1 = active Warning output autocontrol 0 = no warning, 1 = warning Sensor operation 1) 0 = off, 1 = on 1) Sensor operation off when detection is not possible (e.g during the teach event) Input data device Data bit Assignment Meaning 7 6 5 4 3 2 1 0 Deactivation 0 = transmitter active, 1 = transmitter inactive IO-Link device parameters With Leuze Sensor Studio (download at www.leuze.com), all sensors that are equipped with an IO-Link interface can be configured and diagnosed with the aid of the IO-Link service data. Configuration Enabling/locking teach button This function can be used to lock the teach button to prevent tampering with the sensor setting. Easy Tune Activate and deactivate the Easy Tune function of the teach button. L/D switching Configuration of the switching logic of the sensor. Tracking Activates or deactivates the tracking function of the sensor. Logical function of the second switching output Q2 (pin 2) Set the second switching output to the following functions: - Switching output - Inverted switching output - Warning output Switching delay Activates or deactivates the switching delay function. Function selection of the switching delay The following functions can be selected: - Start-up delay - Switch-off delay - Pulse stretching - Pulse suppression PRK18B.TT3/LP-M12-01 2015/11

Tracking retro-reflective sensor for bottles and tape Time base of the switching delay Defines the base of the switching delay, which, for the calculation of the switching delay, is multiplied by the factor. Possible time intervals for the time base are -1ms -10ms - 100ms - 1000ms Factor for time base of the switching delay The time base is multiplied by this factor. If, for example, a time base of 10ms was selected and the factor is 5, the switching delay is 50ms. IO-Link system commands The switching threshold of the sensor can be set via commands; the process is referred to as teaching. The teach level should be selected appropriately for the object that is to be detected. A teach event is always performed with a free light path to the reflector. The following commands can be executed: Teach 11% (full single bottles or tape): Sensor sets the switching threshold to 11% of the free signal; is used for detecting tapes and full bottles made of clear glass or PET. Teach 18% (empty single bottles): Sensor sets the switching threshold to 18% of the free signal; is used for detecting, e.g., unfilled single bottles. Teach 50% (opaque medium): Sensor sets the switching threshold to 50% of the free signal; is used for detecting non-transparent objects. Switch on tracking: Activates the tracking function, which increases the transmitting power in the event of soiling. Switch off tracking: Deactivates the tracking function. Light switching: Sets the switching logic to light switching (sensor switches if reflector is detected). Dark switching: Sets the switching logic to dark switching (sensor switches if reflector is no longer detected). Switch process data to analog value: Outputs the signal values as analog data in a graph. Attention: The depiction of process data is intended only for service operation for testing the application, not as an analog output. The function can only be deactivated by interrupting the voltage supply of the sensor. The sensors offer no data storage and no ISDU support. Sensor setting via teach button The sensor is factory-adjusted for maximum operating range. Recommendation: teach only if the desired objects are not reliably detected. Prior to teaching: Clear the light path to the reflector! The device setting is stored in a fail-safe way. A reconfiguration following voltage interruption or switch-off is thus not required. Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 PRK18B.TT3/LP-M12-01 info@leuze.com www.leuze.com

Teaching for 11% sensor sensitivity (full single bottles or tape) Press teach button until both s flash simultaneously. Release teach button. Ready. After the teaching, the sensor switches when about 11% of the light beam are covered by the object. yellow 2 7s green simultaneously flashing at 3Hz Teaching for 18% sensor sensitivity (empty single bottles) Press teach button until both s flash alternatingly. Release teach button. Ready. yellow green After the teaching, the sensor switches when about 18% of the light beam are covered by the object. 7 12s alternatingly flashing at 3Hz Teaching for maximum operating range (factory setting at delivery) Prior to teaching: Interrupt the light path to the reflector! Press teach button until both s flash simultaneously. Release teach button. Ready. yellow 2 7s green simultaneously flashing at 3Hz Activating/deactivating the tracking function Press teach button until only the green flashes Release the teach button. The yellow displays the tracking function status for 2s: - Yellow ON = tracking activated (factory settings) - Yellow OFF = tracking deactivated After 2s: ready >12s green flashes at 3Hz yellow ON = tracking activated OFF = tracking deactivated PRK18B.TT3/LP-M12-01 2015/11