UniMod Intelligent Communication for all Metering Application



Similar documents
Temperature & Humidity SMS Alert Controller

M-Bus-Logger Data Logger

Remote Meter Reading via M-Bus by Klaus-Peter Richter, Energy Management Product Manager GOSSEN METRAWATT GMBH

Bluetooth Web Enabler

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

TO-PASS. TO-PASS -FAQ- Remote Monitoring. What is TO-PASS used for? What are the special functions of TO-PASS?

INDUSTRIAL GATEWAYS VPN ROUTERS SERIAL DEVICE SERVERS

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Static energy meters

SMS GSM Alarm Messenger

Application/Connection Examples

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Using installed Fieldbus Wiring to carry Ethernet Communications

Plant automation and telecontrol in one system. SIMATIC PCS 7 TeleControl SIMATIC PCS 7. Answers for industry.

Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications

EZ-View Network Communications Guide

ABB RTU560A Series CMU & Modules

INTRODUCTION FEATURES OF THE ICM

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

VOICE RECORDING SYSTEM ISDN PRI / BRI

M2M Industrial Router with modem choice

You can search the event by POS and you can also add the Time Search condition to narrow the search range. By

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

User Manual Revision English

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Cable Connection Procedures for Cisco 1900 Series Routers

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

WEB log. Device connection plans

Rev GSM base station. Installation instructions

Section TELEPHONE AUTOMATIC DIALER SYSTEM

Local PlantVisor. PlantWatch. Remote PlantVisor

Telephone- and leased line modem for industrial applications TD-36

Straton and Zenon for Advantech ADAM Copalp integrates the straton runtime into the ADAM-5550 device from Advantech

What is our purpose?

Single and three phase modular Automatic Transfer Switch from 40 to 160 A

Rack mounted telephone- and leased line modem for industrial applications

RS232 Programming and Troubleshooting Guide for Turbo Controls

Monitoring solar PV output

Remote monitoring & control solutions for cathodic protection rectifier

Tele Eye DT Series. Installation Guide. Dialup CCTV Transmitter DT-103G DT-103P DT-103D

PLC training panel (Twido version)

MONITORING. Software. M2M Transfer. Data Input. Processing. Reports Graphs, Excel Alarms. Logging Analysis, Alarms Various products

PROCESS AUTOMATION. OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS PRODUCT OVERVIEW

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

DCS Data and communication server

Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications

ewon Price List Rev: R45N

ewon - Serial to Ethernet Gateways

Cabling LANs and WANs

Kilomux-2100/2104. Modular integrating access multiplexer for data, voice, fax and LAN. Data Sheet. The Access Company

Smart relays Zelio Logic Step into an intuitive world!

Documentation. M-Bus 130-mbx

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

User Manual Revision English

OPTICAL FIBER repeaters/ isolators

AP60. 9 Wireless. Wireless-b/g/n Long Range PoE Access Point. Wireless-b/g/n Long Range Radio. Passive PoE and 4-LAN Ports. IP Finder Management 4 LAN

MAINTENANCE WITHOUT TRAVELLING

Power Supply and Cabling Options. SmartTrak 100/101/140

Thermal Centers Monitoring. Offer of converters TRM102, TRM202, TRM112, TRM212 and additional options.

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Product Information Fire alarm panel 8000 C

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

MONITORING. m 3 /s. m/s F. g/m 3. Software. Data Input. M2M Transfer. Processing. Reports Graphs, Excel Alarms. Measurement Sensors Dry contacts

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

OPT SERIAL TO FIBER OPTIC CONVERTER

MONITORING. Software. M2M Transfer. Data Input. Processing. Reports Graphs, Excel Alarms. Logging Analysis, Alarms Various products

NC-12 Modbus Application

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

- Monitoring Array: a seismic or infrasound array, including from 1(4) to 20 Remote Elements (RE) and one Central Recording Facility (CRF).

DSX Master Communications

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

IRIS Touch 600 Range Dialler Installation Manual. Version 1.3

MONITORING. m 3 /s. m/s F Pa. g/m 3. Software. Data Input. M2M Transfer. Processing. XML/HTTP SNMP, GPRS/SMS. Measurement Sensors Dry contacts

Data Transmission. Data Communications Model. CSE 3461 / 5461: Computer Networking & Internet Technologies. Presentation B

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

F2103 GPRS DTU USER MANUAL

TrueAlarm Fire Alarm Systems

WEB log. Device connection plans

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. Version 3.0

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

RADIUS. Brief brochure. Product Purpose

GPRS and wireless M2M possibilities in Building Automation

POS Integration. Prepared by: Binh Nguyen

Voice Over Internet Protocol (VoIP) Configuration

5GHz 300Mbps 13dBi Outdoor CPE

Internet-Accessible Power Monitoring & Control Systems

2.24. Pump Controller 704. Data Sheet

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

emobility WAGO Leading the Charge

Process Control and Automation using Modbus Protocol

NXU RoIP Link to Eliminate Voice-Grade Leased Line

Bluetooth HC-06 with serial port module Easy guide

Current Loop Application Note 1495

EDI Distributor Control Interface Wiring and Setup Instructions

T3 Mux M13 Multiplexer

Power, Cable, and Antenna Connection Procedures

1 Technical Description Lokal-200PC

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

Technical Notes TN 1 - ETG FactoryCast Gateway TSX ETG 3021 / 3022 modules. How to Setup a GPRS Connection?

Single and three phase modular Automatic Transfer Switch from 40 to 160 A

Transcription:

Intelligent Communication for all Metering Application

The solution for data communication The different devices of our family support transparent data communication with all needed different interfaces to the data source devices and all communication capabilities to the central station. The applications define the best way to communicate adapted to location and metering device. Metering points of all energy types in industrial or commercial areas can deliver data fast and secure to utilities for billing or control. Industrial users appreciate the possibility to use the existing infrastructure like cables or LAN for economic data retrieval to optimize energy consuming processes or to distribute energy cost. Using a transparent communication mode all renowned data retrieval software can be used. Our new combination of communication device and LAN improves the cost efficiency and speedy communication. The family consists of the following devices: GSM/GPRS-Communication Device PSTN-Communication Device ISDN-Communication Device LAN-Communication Device (Ethernet) Radio-Communication Device The following device interfaces are available: RS232 CS/CL1 (20mA Current-Loop) M-Bus RS485 For the GSM-Modem an additional interface can be used for a simple setting of communication parameter. The software of the GSM-Modules can be updated. The parameters in the can easily be adapted to the desired application and documented by our software Set. It supports the installation and diagnosis of the modem. The powerful parameterization software () enables the user to adapt the modem to all applications and simplifies the installation, e.g. it shows the field strength of the used transmitter)

Highlights Low loss power supply reduces operating costs. Large range of supply voltage increases operating security and reduces logistics cost (e.g. storage). Light emitting diodes simplify installation and diagnosis. Flexible and fast communication rate starting at 300Bd up to 19200Bd Mode C with baud rate changeover according to IEC 62056-21 ( GSM-3/3+/4 only) Optimized use of available bandwidth of the chosen data channel (e.g. GSM/GPRS 9600Bd, ISDN 64kBd) reduces data transfer time. Optimized data transfer time means less telephone fees, more devices can be checked in the same period and less channels are needed at the central station. IP-Telemetry according to DIN 43863-4 (GSM-4 only) Easy to use parameter setting software available. EU-approval CE, CETECOM, LABORELEC, ENDESA Proven with all renowned protocols like SCTM, LSV1, IEC 62056-21 (61107), IEC 60870-5, dlms, M-Bus, ModBus. Simple installation: the housing fits on meter fixings (according to DIN 43861-2). Even if the environment is a little bit rough: with IP52 the can withstand a lot. Works with meters of all metering manufactures. Sealable housing prevents tampering. Watchdog for GSM- Modems enhances performance and availability. Applications Power Generation Power Distribution local Power Generator Consumers Commercial Hotels, etc. Industry 20 ma Meter M-Bus RS 232 RS-485 M-Bus s Repeater 01/I 01/ISDN GSM Radio 01/I Ethernet LAN PSTN (analog) ISDN GSM Communication Networtk PSTN (analog) Modem (ISDN, PSTN, GSM) Remote Meter Reading Station RS232 Ethermet PC

Which Interface for which Application?...01001110... The data of the meter can be transferred to the modem by many ways. However, one is common to all: the data converted into a serial, binary data stream has to enter the modem via a special interface (Module): Interface at the meter Which module? One meter with RS 232 (up to 15m cable between meter and ) RS232 Up to 3 meters distributed up to 1000m 20mA interface in the meter 20mA Up to 20 meters distributed up to ca. 5 km, With Bus Repeater (optional) up to 250 devices can be connected 2 wire cable to the meters available M-Bus interface in the meter Up to 32 meters distributed up to 1000m RS485-Bus available (2 wire or 4 wire) RS485 interface in the meter Multiple meters distributed on one site Impulse output (e.g. S0) No serial communication interface M-Bus RS 485 DLX/DLM6 (more information at www.baer-gmbh.com) The maximum cable length and the number of devices to be connected to may vary and depend on the local conditions. Which Modem for which Application?...01001110... As soon as the data has arrived at the modem, it can be sent to the central station by different communication channels. Criteria are customer satisfaction, cost, availability and speed. Application Advantages Type Main connection or extension available, customer acceptance available, telephone connection close to modem Low price 01/I (PSTN) Main connection or extension available (in ISDN Mode), customer acceptance available, telephone connection close to modem Time window for data retrieval freely selectable Low price Fast communication 01/ISDN No telephone connection available Costly new installation (long cables, openings, etc.) No customer acceptation to provide telephone connection Short term need due to change of energy supplier or change of tariff Approval for EU, China etc. Fast implementation No annoyance for the customer Low price Installation GSM-4 (via GSM/GPRS) Need to bridge a cable less distance (e.g. street, railway tracks, etc.) Connection to a PC, Modem or M-Bus line offers many new application No additional telephone connection necessary Offers air-cable with no additional fees Communication distance between 50m to 100m (depends on local conditions, laws and approvals) No fees Low price installation Fast data retrieval Radio-B Local Area Network (LAN) already available, e.g. for control purposes or for PC communication No fees Fast data retrieval Ethernet Note: Features and look of the devices described in this leaflet could be adapted to technological development or changed in any other way.

The Product Family Modems / Metcom T Renewable Energy Management M-Bus / RS485 BaerFieldControl-System Data Loggers DLM6 / DLX AMR Software SIGLON Meter2SCADA Cubical Design and Installation Relais

Type How to Order the Universal Communication Device Communication to Central Station GSM-4 GSM-Modem with Quad-Band GSM and GPRS option (multi-slot class 10) three internal interfaces: RS232 (Service), RS485 2 wires, 20mA (CS, current loop) 01/I PSTN Modem (analog) 01/ISDN ISDN-Modem Radio-B Radio-Modem Bluetooth Ethernet LAN-Modem to connect devices to a local area network using Ethernet technology Interface Modules 10 RS232 interface via terminals (also for connection of a PC to the Ethernet) 15 RS232 interface via terminals; with 9V power supply (used e.g. by some gas flow computers) 20 20mA (CS) interface, active (standard, if supplements are missing) 21 20mA (CS) interface, passive 40 M-Bus interface, active, up to 20 devices 41 M-Bus interface, passive 72 RS485 interface, 2 wire 74 RS485 interface, 4 wire Order supplements Antenna (only GSM..) A00 No antenna (standard, if supplements are missing) A01 Antenna with magnetic foot; 0dB gain; 2,6m cable A02 Fixed antenna with mounting device; 2dB gain; 5m cable A03 Fixed log periodic antenna; 10dB gain; 0,5m cable A04 Antenna with magnetic foot; 3dB gain; 2,6m cable A05 Mini-Antenna; 0dB gain; length 5cm Software, Accessories Baud rate of the electrical interface at delivery time B00 Mode C according to IEC 62056-21 (supported by GSM-4 only) B01 1200 Baud B02 2400 Baud B03 4800Baud B04 9600 Baud (standard, if supplements are missing) B05 19200 Baud Data format of the electrical interface at delivery time D01 7E1 (7 Data bits, Even Parity, 1 Stopbit) (standard, if supplements are missing) D02 8N1 (8 Data Bits, No Parity, 1 Stopbit) D03 8E1 (8 Data Bits, Even Parity, 1 Stopbit) External power supply PS12 Power supply; input: 100-240VAC, output: 12VDC, 2A Telephone connection (only 01/I.. and ISDN) T00 No cable (standard, if supplements are missing) T01 Telephone cable for TAE 6N-socket; 3m length T02 ISDN-Phone cable RJ45, 3m length Set Software to change parameters and to support installation using a RS232 interface (OS: MS Windows 95, 98, ME, NT, XP, Vista, 7, 8 or Server 2000/2003/2008/2012) Set P Software to change parameters and to support installation using a RS232 interface; additional: protocol test procedures e.g. for M-Bus, IEC 62056-21 (61107), IEC 60870-5, SCTM, Elster-Gas, dlms Adapter for Universal adapter for all s (Order No.: #9177) RS232 cable 9pol. Standard RS232 cable, only for GSM-3/3+/4 (Order No.: #4301) Order Examples = if no order supplements are given, this will be the standard delivery GSM-4 10 A00 GSM-Modem with RS232 interface, no Antenna, baud rate set at 9600 Baud, 7E1; 01/I 20 B02 PSTN modem (analog) with 20mA interface, active, baud rate set at 2400 Baud, 7E1, no cable; 01/I 40 D02 PSTN modem (analog) for meters with M-Bus, active; baud rate set at 9600 Baud, 8N1, no cable; 01/ISDN 74 B04 D01 T02 ISDN-Modem for meters with RS485 interface 4 wires, baud rate set at 9600 Baud, 7E1, ISDN- Phone cable RJ45; Bär Industrie-Elektronik GmbH Siemensstr. 3 90766 Fürth Germany Phone: +49 911 97059-0 Fax: +49 911 97059-50 Subject to change without notice! E-Mail: info@baer-gmbh.com Web: www.baer-gmbh.com Version: 01. 2016 Brochure No.: # V2.0