Wet gas compressor capacity limits

Similar documents
C. starting positive displacement pumps with the discharge valve closed.

ADVANCED CONTROL TECHNIQUE OF CENTRIFUGAL COMPRESSOR FOR COMPLEX GAS COMPRESSION PROCESSES

Optimization of Natural Gas Processing Plants Including Business Aspects

Heat Integration Complicates Heat Pump Troubleshooting

TABLE OF CONTENT

5.2. Vaporizers - Types and Usage

ECONOMICAL OPTIONS FOR RECOVERING NGL / LPG AT LNG RECEIVING TERMINALS

PRACTICAL PROCESS HYDRAULICS CONSIDERATIONS

20,000 Barrel Per Day Crude Oil Refinery

Lecture 9 Solving Material Balances Problems Involving Non-Reactive Processes

Routinely surveying tower overhead vacuum systems can

UNDERSTANDING REFRIGERANT TABLES

How To Make A High Co 2 Gas Blend

Natural gas liquids recovery from gas turbine fuel

The Piping System Model a New Life Cycle Document. Elements of the Piping System Model

Vacuum ejector system design, operation and performance

ACFM vs. SCFM vs. ICFM Series of Technical White Papers from Ohio Medical Corporation

Design Guidelines for Using Distillation Simulation Software in the Field

Chapter 2 P-H Diagram Refrigeration Cycle Analysis & Refrigerant Flow Diagram

Valve Sizing. Te chnic al Bulletin. Flow Calculation Principles. Scope. Sizing Valves. Safe Product Selection.

AM Cost Effective Solutions for Reduction of Benzene in Gasoline

Design Procedure. Step 2: The simulation is performed next. Usually the column is not difficult to converge, as the liquid reflux ratio is large.

Why and How we Use Capacity Control

Saeid Rahimi. Effect of Different Parameters on Depressuring Calculation Results. 01-Nov Introduction. Depressuring parameters

Dry-out Design Considerations and Practices for Cryogenic Gas Plants

APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES

MERCURY REMOVAL FROM NATURAL GAS AND LIQUID STREAMS ABSTRACT. Giacomo Corvini, Julie Stiltner and Keith Clark UOP LLC Houston, Texas, USA

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

TOPIC: KNOWLEDGE: K1.01 [3.3/3.5] Which one of the following contains indications of cavitation in an operating centrifugal pump?

Air Eliminators and Combination Air Eliminators Strainers

The. Brendan P. Sheehan, Honeywell Process Solutions, USA, and Xin Zhu, UOP, a Honeywell Company, USA, explore energy optimisation in plant processes.

DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING

Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

Everest. Leaders in Vacuum Booster Technology

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

Equipment Performance Monitoring

Understanding ejector systems necessary to troubleshoot vacuum distillation

Centrifugal Fans and Pumps are sized to meet the maximum

Introduction to Process Engineering Economics. based on size of major equipment items allow to decide whether to invest in a detailed study

Practice Problems on Pumps. Answer(s): Q 2 = 1850 gpm H 2 = 41.7 ft W = 24.1 hp. C. Wassgren, Purdue University Page 1 of 16 Last Updated: 2010 Oct 29

OPTIMIZING CONDENSER WATER FLOW RATES. W. A. Liegois, P.E. Stanley Consultants, Inc. Muscatine, Iowa

Integrated Performance and Condition Monitoring at DuPont

No. Name Description Main input Data Main Output Data. cooling duty, process in/out temperature, inlet air temperature

Chapter 19 Purging Air from Piping and Vessels in Hydrocarbon Service

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district

Twin Screw Technology. General Overview and Multiphase Boosting 11/2013. Calgary Pump Symposium 2013

How To Make A Mine Guard Fosil Process

Some Criteria for Choosing a Steam Boiler for a Microbrewery

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

Rosemount Orifice Plate in Wet Gas

Dynamic Models Towards Operator and Engineer Training: Virtual Environment

Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"

CO MPa (abs) 20 C

SUPERSONIC GAS CONDITIONING - COMMERCIALISATION OF TWISTER TECHNOLOGY

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Centrifugal Water Chillers. Scott Meyerkord

Evaluation Of Hybrid Air- Cooled Flash/Binary Power Cycle

QUESTIONS THERMODYNAMICS PRACTICE PROBLEMS FOR NON-TECHNICAL MAJORS. Thermodynamic Properties

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

Unsteady State Relief Valve Evaluation. External Pool Fire Scenario

BASIC UNDERSTANDING OF FLOW CALCULATIONS AND ESTIMATES MAKES SIZING VALVES SIMPLER

The Distillation Group, Inc.

DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS

Rusty Walker, Corporate Trainer Hill PHOENIX

STEADY-STATE AND DYNAMIC SIMULATION OF CRUDE OIL DISTILLATION USING ASPEN PLUS AND ASPEN DYNAMICS

Thermal Coupling Of Cooling and Heating Systems

Chapter 3.5: Fans and Blowers

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps

Modelling and Simulation of the Freezing Systems and Heat Pumps Using Unisim Design

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

Steam System Best Practices Condensate System Piping

How To Clean Up A Reactor Water Cleanup

Gas Detection for Refining. HA University

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

DRY SCREW COMPRESSOR PERFORMANCE AND APPLICATION RANGE

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

PULSATION REDUCTION BY ACOUSTIC FILTERS FOR METERING APPLICATIONS. Robert J. McKee Ray G. Durke

FLOW COMPUTERS METERING, MONITORING, & DATA ACQUISITIONS. Sami Halilah Dynamic Flow Computers Houston, Texas

RECTIFIER DESIGN FOR FUEL ETHANOL PLANTS

OIL & GAS PRODUCTION AUDITING

Thermal Dispersion Mass Flow

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

How Ground/Water Source Heat Pumps Work

LEAN LNG PLANTS HEAVY ENDS REMOVAL AND OPTIMUM RECOVERY OF LIGHT HYDROCARBONS FOR REFRIGERANT MAKE-UP

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

FLUID FLOW Introduction General Description

TEMA DESIGNATIONS OF HEAT EXCHANGERS REMOVABLE BUNDLE EXCHANGERS NON REMOVABLE BUNDLE EXCHANGERS SOURCE:

Industrial Steam System Process Control Schemes

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

In-Line Air Separators

ECO-STAR II. ECO-nomical ECO-logical the ECO-STAR II. Packaged Low NOx Multi-Fuel Burner. Features. Benefits. Combustion Excellence Since 1888 ESII-1

How To Power A Power Plant With Waste Heat

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

UNIT 2 REFRIGERATION CYCLE

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

NATURAL GAS EXPERIENCE

Transcription:

Understanding Centrifugal Compressor Performance in a Connected Process System Scott Golden, Scott A. Fulton and Daryl W. Hanson Process Consulting Services Inc., Houston, Texas Wet gas compressor capacity limits feed rate or unit conversion in many FCC and delayed coker units. Understanding compressor performance and its interaction with the connected process systems is critical when revamping FCC and delayed coker units. Many times unnecessary changes are made to the compressor and driver. Alternatively, lower cost process system modifications can be used to debottleneck a compressor limit. Figure 1 shows a block diagram of a compressor and the connected process system components. The connected process system and compressor performance must be thoroughly evaluated as a single system to determine the most cost-effective way to increase compressor capacity, but conventional process design approaches use several equipment disciplines to evaluate piping, heat exchange, and distillation systems independently. Thus the opportunity to debottleneck the compressor with lower cost process system changes may go unnoticed. Reducing system pressure drop (Table 1) to increase suction pressure or decrease discharge pressure allows more gas to be compressed through the compressor without modifications. However, the impact of suction and discharge system changes on compressor capacity is not the same. Table 1. Process Equipment Pressure Drop Main Column Internals Piping/Nozzles Control Valves Fin-fans Shell and Tube Exchangers Flow Metering Suction pressure changes have a much larger influence on compressor capacity due to their effect on overhead receiver condensation, gas density, and compressor head. process flow scheme, tower internals, heat exchangers, piping/nozzles, control valves, and orifice plate modifications. These components all generate pressure drop. Process flow scheme changes may include adding a pumparound to the main column or bypassing absorber bottoms liquid around the high pressure condenser to reduce pressure drop. System pressure drop between the main column inlet nozzle and the compressor inlet will vary from a low of 5 to over 25 psi. High pressure drop components need to be identified and cost-effective and reliable changes made. In some instances, replacing main column trayed internals with structured packing will be the low-cost solution. Other times, condenser system pressure drop will control compressor suction pressure. Therefore, piping, fin-fan, shell and tube exchanger, control valve, or flow metering modifications will need to be considered. Absorber operating pressure and system pressure drop set the compressor discharge pressure (Figure 1). Lower discharge pressure reduces compressor head and driver power, which increases compressor capaci- Connected Process System Process system operating pressure and system pressure drop strongly influence wet gas compressor capacity. Compressor discharge and suction pressure are variables and should be manipulated whenever possible to raise compressor capacity. Increasing compressor suction pressure and reducing discharge pressure will increase compressor capacity. Finding cost-effective solutions always starts with field measurements of the current operation to identify high pressure drop components. Distillation column internals, process piping, heat exchangers, control valves, and flow metering in the connected process system must be modeled together with the compressor to quantify compressor capacity increases resulting from equipment modifications. In an FCCU, feed rate, reactor/regenerator differential pressure, and system pressure drop set compressor suction pressure. In a coker, coke drum constraints and the system pressure OVERHEAD drop set suction CONDENSERS CONDENSERS SYSTEM pressure. Discharge pressure is controlled by the gas COLUMN plant operating FEED pressure and system pressure drop. Practical changes to consider include Figure 1. Compressor and Connected Process System ABSORBER/ DEETHANIZER FUEL GAS

FROM OVERHEAD TO INTERSTAGE CONDENSER LOW STAGE FROM INTERSTAGE TO HIGH CONDENSER HIGH STAGE Figure 2. Compressor Block Diagram DRIVER (MOTOR OR STEAM TURBINE) POLYTROPIC HEAD, FEET 29,000 7,700 RPM 28,000 27,000 26,000 25,000 24,000 23,000 11,500 12,000 12,500 13,000 13,500 14,000 14,500 VOLUMETRIC FLOW, ICFM Figure 3. Compressor Performance Curve, Low-Stage ty. Discharge pressure should be minimized without reducing gas plant performance. Absorber pressure controls C 3 recovery assuming other process variables have been optimized. In a few instances, reducing absorber operating pressure will not materially change C 3 recovery. In most cases, however, propylene recovery drops as pressure is reduced and it is not a costeffective way to increase compressor capacity. If the existing compressor discharge system has high pressure drop, then equipment changes may be an effective means to debottleneck the compressor. Typically, compressor discharge pressure will need to be reduced by at least 20 psi to have a meaningful effect on compressor capacity and driver power. Compressor Fundamentals Most FCC and delayed coker wet gas compressors have an inter-cooler system that improves compressor efficiency and reduces the gas temperature rise through the stages of compression. Inter-cooled compressors will have a low-stage curve defining performance upstream of the inter-cooler and a high-stage curve for the downstream portion (Figure 2). In reality, the low (Figure 3) and high-stages (Figure 4) will have 3-4 actual wheels having their own individual performance curves. These low and high-stage performance curves are a composite of the individual stage (Figure 5) curves. Usually these low and high-stage curves are sufficient to evaluate compressor performance and the connected process system s influence on compressor capacity. Centrifugal compressors have performance curves similar to pumps. The major difference is that a compressor moves gas which is compressible, while the pump moves liquid that is not compressible. The compressor curve flow term is always based on inlet conditions; consequently inlet gas density influences volumetric flow. Flow is shown on the X-axis and head on the Y-axis. For a fixed speed, the curve shows that for a known inlet flow rate a fixed head is developed. Centrifugal compressor inlet flow rate increases as the head decreases. Gas plant operating pressure, connected system pressure drop, and gas composition sets the developed head. Increasing suction pressure, decreasing gas plant operating pressure and/or decreasing process system pressure drop will increase inlet flow rate as long as the compressor is not operating at choke flow. A compressor curve starts at the surge point and ends at stonewall, or choke flow. The surge point is the head at which inlet flow is at its minimum. At this point, the compressor suffers from flow reversal, which is a very unstable operation that is POLYTROPIC HEAD, FEET 28,000 7,700 RPM 26,000 24,000 22,000 20,000 18,000 16,000 2,800 3,000 3,200 3,400 3,600 3,800 4,000 4,200 VOLUMETRIC FLOW, ICFM SUCTION LOW STAGE INTERCONDENSER SYSTEM HIGH STAGE DISCHARGE Figure 4. Compressor Performance Curve, High-Stage Figure 5. Compressor Stages

accompanied by vibration and possible damage. On the other end of the curve is the choke (or stonewall) point. At the choke point, the inlet flow through the compressor cannot increase no matter what operating changes are made. Therefore, the range of compressor performance is defined between these two flowhead limitations. Typically, the curve is flat near the surge point and becomes steeper as flow is increased. Hence, small head changes near the surge point cause a large increase in compressor capacity. As compressor operation moves toward stonewall, decreasing head has less influence on inlet flow rate because the curve slope increases. As the stonewall point is approached, changes in head will have negligible effect on inlet flow rate. Compressor Inlet Flow The performance curve flow rate is based on suction conditions and expressed as inlet cubic feet per minute (ICFM). It is not standard gas flow metering units. Wet gas is a compressible fluid, therefore changes in compressor suction conditions that increase gas density will reduce wet gas volumetric flow rate and free up compressor capacity. Gas density is a function of temperature, pressure, and gas molecular weight. Gas density is calculated from the ideal gas law shown in equation 1. For a fixed mass flow Equation 1. Gas Density = P(MW)/RT P = Gas pressure (absolute) T = Gas temperature (absolute) MW = Gas molecular weight R = Gas constant rate and gas composition, temperature has a small effect on gas density because the temperature term is very large. Conversely, increasing compressor suction pressure will significantly increase gas density and reduce the gas volume. The lower the suction pressure the larger the effect of pressure changes on compressor capacity. For example, increasing pressure from 18.7 psia to 20.7 psia decreases the inlet gas flow rate by 10.6% for the same mass flow rate. When the suction pressure is 44.7 psia the same 2 psi change reduces gas volume by only 4%. Increasing gas molecular weight will also increase gas density and reduce volume for a fixed mass flow rate. Reactor and coke drum effluent composition controls gas molecular weight. FCC dry gas typically has a molecular weight in the range of 21-23. Typical propylene/propane mixtures have a molecular weight of 43.5. As the FCC reactor reduces the dry gas yield and increases heavier C 3 and C 4 s yield, the wet gas molecular weight and wet gas density increase, thus reducing inlet volume. A 5% increase in gas molecular weight decreases inlet volume flow rate by 5% for a fixed temperature and pressure. Compressor Head Centrifugal compressors do not develop a constant differential pressure; they develop a constant differential polytropic head at a given inlet flow rate. Often, the compressor curves provided by the E&C company or the compressor vendor will report the performance curve as differential pressure versus inlet flow rate. These differential pressure curves represent one set of inlet operating conditions only. They are not sufficient to evaluate the compressor and connected system performance. Understanding the components of this head term is essential when considering the influence of the process operating pressure and the system pressure drops effect on compressor capacity. Equation 2 shows the polytropic head term. Reducing polytropic head will increase Equation 2. H p = 1,545 MW Z AVG T 1 POLYTROPIC HEAD, FEET 28,000 27,000 26,000 25,000 24,000 Where: H p Polytropic head, ft MW Molecular weight Z AVG Average compressibility T 1 Suction temperature, R n Compression coefficient P 1 Suction pressure, psia P 2 Discharge pressure, psia compressor capacity by moving the operating point to the right except at stonewall. The slope of the curve will determine the 1,500 FT HEAD 23,000 11,500 12,000 12,500 13,000 13,500 VOLUMETRIC FLOW, ICFM 7,700 RPM REDUCED HEAD 6% 14,000 14,500 Figure 6. Compressor Performance Curve, Head Reduction n n 1 n 1 n 1 P 2 P 1 magnitude of the inlet flow rate increase resulting from a given polytropic head reduction. Process changes that move the operating point to the right include higher gas molecular weight, raising suction pressure, or lowering discharge pressure. Gas temperature changes have little influence on head. Compressor molecular weight is set by the coke drum or FCC reactor gas composition. Suction pressure changes of 5 psi or higher can also influence gas composition and molecular weight through the impact of condensation. Compressor suction and discharge pressure both influence the polytropic head. Compressor discharge pressure is set by the gas plant operating pressure and the pressure drop from the compressor discharge to the absorber pressure control valve. For instance, compressor discharge and suction pressures of 220 psig and 10 psig, respectively, are common. Therefore, the pressure ratio term is 234.7 psia/24.7 psia or 9.5. Reducing head requires a decrease in the pressure ratio term. This simplified evaluation ignores the influence of the inter-stage system. Understanding how discharge and suction pressure influence the polytropic head term and compressor capacity is the key to evaluating potential connected process system modifications. Figure 6 represents the influence of a 1500-foot head reduction on compressor inlet flow rate for one compressor. Increasing suction pressure P 1 or decreasing discharge pressure P 2 will reduce head. Quantifying the suction and discharge pressure changes that result in the same polytropic head reduction is useful. Either increasing suction or decreasing discharge pressure can be used to reduce polytropic by 1500-feet and

FRACTIONATOR VAPOR COMP. COMP. DRIVER STRIPPER VAPOR PRIMARY ABSORBER BOTTOMS PRIMARY ABSORBER FEED PRODUCTION, ICFM 15,000 12,000 9,000 9 10 11 12 13 OVERHEAD, PSIG TEMPERATURE=100 F Figure 8. Suction Pressure vs. Wet Gas Production OVERHEAD INTERSTAGE HIGH PRESS. STRIPPER/ DEETHANIZER FEED PRIMARY ABSORBER LIQUID FEED PRODUCTION, ICFM 18,000 15,000 12,000 100 110 120 130 140 OVERHEAD TEMPERATURE, F =8.5 PSIG Figure 7. Compressor and Connected System Figure 9. Suction Temperature vs. Wet gas Production increase the compressor inlet flow capacity by 6%. Suction pressure changes have a much larger influence on compressor capacity than discharge pressure changes. Raising suction pressure by 2.0 psi decreases the head by 1500-feet as a result of reducing the pressure ratio term from 9.5 (234.7/24.7) to 8.8 (234.7 psia/26.7 psia). The compressor discharge pressure would have to be lowered from 220 psig to 202 psig (P 2 /P 1 =216.7 psia/24.7 psia =8.8) to produce the same head reduction. Reducing gas plant operating pressure reduces propylene recovery and an 18 psi operating pressure reduction is generally not feasible. On the other hand, it may be possible to reduce system pressure drop by 18 psi. Suction pressure changes of 2 psi, however, are practical on many units. Compressor Capacity: Driver Power Compressor driver power requirements can also limit the compressor maximum Equation 3. Compressor SHP = (m) H p /[(n p ) 3300] 1.02 SHP Shaft horsepower H P Polytropic head m Mass flow rate of gas n p Polytropic efficiency 1.02 2% gear losses flow rate. When the drivers are limited the turbine steam rate and speed or the motor amps are at maximum. Compressor driver power consumption is a function of the mass flow, compressor polytropic head, compressor efficiency, and gear efficiency. Compressor shaft horsepower (SHP) is shown in Equation 3. Reducing polytropic head lowers the compressor shaft horsepower. Unit Operations Wet gas compressors increase the system operating pressure so that C 3 -C 12 hydrocarbon components can be recovered as liquid product. Compressor system operating suction and discharge pressure will vary depending on reactor/regenerator, coke drum, gas plant, compressor, and/or upstream equipment design and operation. The compressor takes suction from the main column overhead receiver or downstream knockout drum, which operates at 1.5-30 psig and discharges to a gas plant absorber/deethanizer system operating at 160-240 psig. (Figure 7) Main column overhead receiver temperature and pressure determine the amount of wet gas production for a fixed reactor effluent or coke drum composition. Increasing compressor inlet pressure and/or decreasing temperature reduces the wet gas mass flow rate by changing the amount of condensation that occurs. Compressor suction pressures and temperatures vary from 1.5 to 30 psig and 80 F to 135 F, respectively. Main fractionator pressure and temperature can be optimized through equipment changes. Figures 8 and 9 show the effect of pressure and temperature on wet gas rate for one unit. A low-capital revamp may involve replacing the 4-tube row fin-fan bundles with 6-row bundles. The 6-tube row bundles will have less than half the pressure loss of the 4-tube rows and add surface area that can lower receiver temperature. In one instance, this raised compressor capacity by over 20% by increasing receiver pressure by 2 psi and reducing temperature by 10 F. Three revamp examples will highlight the relationship between the connected process system pressure drop, compressor performance curves, and wet gas compressor capacity. EXAMPLE 1: Increasing Compressor Suction Pressure Using Structured Packing A 50,000-bpd unit was revamped to increase capacity to 65,000 bpd. Wet gas compressor capacity was one of the major unit limits. Revamping the compressor, installing a new parallel compressor, or

COLUMN COLUMN 14.0 18.0 ATMOSPHERE ATMOSPHERE 20.0 22.0 10.5 10.0 20.0 22.0 14.5 14.0 AIR 32.0 OIL FEED 19.0 TRAY P=5.0 PSI = PSIG AIR AIR BLOWER 32.0 OIL FEED 19.0 PACKING P=1.0 PSI = PSIG Figure 10. Main Column with Trays Pressure Profile Figure 11. Main Column with Packing Pressure Profile reducing connected system pressure drop were all evaluated and cost estimates generated for each option. Compressor performance curves, driver horsepower, and connected system pressure drop were all thoroughly studied. Compressor modification required changes to the compressor internals, motor replacement, new motor control center gear, and substation modifications. A new parallel compressor was very expensive and increased operating complexity. Reducing system pressure drop was the least-cost option. Compressor suction pressure drop includes the main column, condenser system, and piping. Condenser and overhead system pressure drop were only 3.5 psi. Main column pressure drop was 5 psi, which represented over 60% of the suction system pressure loss. The unit pressure profile is shown in Figure 10. The main column overhead receiver operated at 10.5 psig. The revamp replaced the trays with structured packing (Figure 11). This reduced column pressure drop to 1.0 PSI. Compressor inlet pressure was increased from 10.5 to 14.5 psig. This increased condensation, increased gas density, decreased compressor polytropic head, and decreased the inlet volume to the compressor. This increased compressor mass flow capacity by over 30% without changes to the compressor or the driver. EXAMPLE 2: Increasing Compressor Suction Pressure, Reduced Piping Pressure Drop A 40,000-bpd unit was revamped to add a heavy naphtha draw and increase unit capacity by 20%. Heavy naphtha contains a large portion of the gasoline sulfur, and the gas plant liquid handling bottlenecks limited unit conversion. Wet gas compressor capacity was one of the revamp limits. A consequence of the heavy naphtha draw is that wet gas production increases as overhead gasoline rate decreases. Prior to the revamp, the compressor was operating at maximum capacity. Unlike example 1, where the main column had high pressure drop, here the column pressure drop was only 2.5 psi. Piping and condenser system represented almost 85% of the total system pressure loss. This emphasizes that accurate field measured pressure drop must be done as part of preparing for any revamp. The overhead system pressure profile shown in Figure 12 had a measured pressure drop of 13 psi. Pressure drop from the fin-fan outlet to the compressor was 10 psi. The revamp replaced the piping downstream of the fin-fans, shell and tube exchanger shell, piping to the overhead receiver, and orifice plate. Compressor inlet pressure was increased from 2 to 7.5 15.0 15.0 12.0 12.0 OULET 9.0 6.0 4.0 INLET 2.0 11.0 EXCHANGER SHELL OULET 9.0 8.5 INLET 7.5 VENTURI SUCTION INCREASED BY 5.5 PSI Figure 12. FCC Measured Pressure Drop Figure 13. FCC Revamp Pressure Drop

psi (Figure 13). This increased condensation, increased gas density, decreased compressor polytropic head, and decreased the inlet volume to the compressor. This raised compressor mass flow capacity by over 30%. EXAMPLE 3: Increasing Compressor Suction Pressure, Reduced Fin-fan Pressure Drop A delayed coker unit revamp objective was to increase capacity by 25%. The unit was operating at the maximum compressor capacity. If compressor suction pressure and temperature were maintained at current conditions, increasing the gas flow rate by 25% would require major compressor and driver modifications at a cost of more than $2 MM. Hence, more cost effective process system changes were evaluated. The study began with a comprehensive 30.0 COKER FRACTIONATOR 29.0 field test run to gather all the necessary data to calibrate process and equipment models. This was the critical first-step in establishing all significant unit bottlenecks. As part of the test run, the column and overhead system pressure profile was measured with two digital pressure gauges. Pressure readings between any two points were taken simultaneously with gauges accurate to within +/-.01 psi. The unit pressure profile is shown in Figure 14. Measured overhead system pressure drop was 16 psi with 13 psi measured across the fin-fans alone. The pressure drop from the overhead receiver to the compressor was 2.5 psi with more than 50% across the orifice meter. Hence measured pressure profiles clearly pinpointed the high pressure drop components. As noted, modifying the compressor would be very costly. Reducing fin-fan and orifice plate pressure loss would be a more cost-effective alternative. Compressor inlet pressure could be increased from 13 to 23 psi (Figure 15) with its resultant benefits. 16.0 13.0 15.5 Figure 14. Delayed Coker Measured Pressure Drop 30.0 COKER FRACTIONATOR N FANS 29.0 24.5 25.0 23.0 Figure 15. Delayed Coker Revamp Pressure Drop Process system changes from the main column overhead to the compressor would include a new fin-fan bay in parallel to the existing bays, new fin-fan bundles with additional tube row design to lower pressure drop and increase surface area, and larger fan motors to raise the air rate. Thus, overhead receiver temperature could be maintained at pre-revamp conditions with a 10 psi increase in compressor suction pressure. In addition, compressor discharge system condenser pressure loss (Figure 1) would be very high at increased gas flow. Discharge system condenser modifications would permit lower compressor pressure. These changes would debottleneck the wet gas compressor limit without changes to the compressor or auxiliaries. Increased condensation, increased gas density, decreased compressor polytropic head, and decreased inlet volume to the compressor would be the outcome. This would permit a 25% increase in feed rate without any compressor modifications. The cost would be a fraction of a new compressor. THE AUTHORS Scott W. Golden is a chemical engineer with Process Consulting Services in Houston, TX. The company specializes in refinery unit revamps. His previous experience includes refinery process engineering and distillation troubleshooting and design. Golden has authored more than 80 technical papers on revamping, troubleshooting, and distillation. He holds a BS degree in Chemical Engineering from the University of Maine and is a registered professional engineer in Texas. Scott A. Fulton is a chemical engineer with Process Consulting Services in Houston, TX. He has worked on 10 FCC unit revamps in his current position, where he is responsible for process flow sheet modeling, conceptual design, and detail equipment modeling and design. Fulton previously worked as a process engineer for Coastal Corporation performing revamp and troubleshooting work for its refineries in the US and Caribbean. He has authored several papers on revamping. He holds a BS degree in Chemical Engineering from Texas A&M University. Daryl W. Hanson is a chemical engineer with Process Consulting Services in Houston, TX. His responsibilities include process and equipment design and field troubleshooting. He specializes in all phases of refinery distillation from process simulation through field inspection. Previously he was lead process specialist for Koch-Glitsch Inc. where he was involved with more than 100 column revamps including heavy oils and light-ends recovery towers. Hanson has authored more than 20 technical papers on revamping, troubleshooting, and distillation. He holds a BS degree in Chemical Engineering from Texas A&M University.