Heat Integration Complicates Heat Pump Troubleshooting
|
|
|
- Peregrine Grant Harvey
- 10 years ago
- Views:
Transcription
1 Heat Integration Complicates Heat Pump Troubleshooting by Donald F. Schneider, PE Chemical Engineer Stratus Engineering, Inc. PMB Marina Bay Drive #130 League City, Texas (281) Fax: (281) Copyright 2001 Don Schneider
2 Introduction A naphtha fractionator unit had operated well for years but began to experience inexplicable warm weather trips of the heat pump compressor. During the summer the compressor would shut down on high discharge temperature for no apparent reason. Feed rates were high but not beyond design. The initial thought was that the compressor driver was inadequate. The compressor driver was due for overhaul it would be an opportune time to replace it with a high Horsepower machine. Focusing on the compressor would be easy, and it might even be correct. However, you could also buy a large Horsepower driver, put it in, and have the same problem. That would be an uncomfortable look-back meeting. Perhaps that is why so few project look-back meetings are held... The cost of a higher Horsepower driver was evaluated. It would be very expensive, but would be worth the expenditure if it worked. The unit outages during high product demand reduced production and raised maintenance costs. Before an order for a new compressor driver was placed though, a detailed review of the entire system was undertaken. Engineering is usually thought of as a cost. In this case, engineering was the best way to reduce costs. You could even conclude that engineering actually increased profits! 1
3 Heat Pumps A heat pump adds mechanical work to a low value energy source so that it can be transferred to a high value energy sink. In the Hydrocarbon Processing Industry heat pumps are typically employed in condensing and reboiling fractionation columns. The traditional column of Figure 1 is shown as a heat pump design in Figure 2. The Figure 1 condenser and reboiler exchangers and their associated utilities are replaced by the compressor and single exchanger of Figure 2. The heat pump system uses the column's overhead duty for reboil. This is made possible by the compressor which boosts the overhead stream's pressure and temperature so that it condenses in the reboiler against the column bottoms. Heat pumps derive their benefit from lower energy costs in comparison to traditional designs. The traditional design energy consumption is the sum of both the condensing and reboil duties while the heat pump energy consumption is only the compressor horsepower. For a particular column, the economic viability of a heat pump versus a traditional design is determined to a great degree by the temperature difference between the column's top and bottoms. The larger the column temperature difference, the higher the required compression ratio and compressor horsepower. The T sweet spot for heat pump applications is typically 20 to 40 degrees F. Low operating pressures that swell compressor size due to large volumetric flow rates, and high operating temperatures that push compressor design thermal constraints are two other conditions that exclude heat pumps from process consideration. Heat pump systems are more complicated and typically require a higher initial capital outlay than traditional designs. Their elimination of heating and cooling utilities and their lower energy consumption must overcome this burden for a profitable application. 2
4 System Figure 3 illustrates the system under review here. A naphtha stream is being fractionated to recover valuable products. The Depropanizer Bottoms is fed to the Debutanizer (DIB) of Figure 3 for C4's removal. The Debutanizer Overhead is sent to a Deisobutanizer where Isobutane is separated from n-butane. The Debutanizer is a typical design and has the added benefit that its overhead is used in part to reboil the Deisobutanizer. The DIB with an overall column temperature difference of ~30 F and an overhead pressure of ~70 psia is able to employ a heat pump for condensing and reboil. Warm weather has the following effects at the plant: Compressor driver capacity diminishes. Cooling water temperatures rise. Air-cooler capacity decreases. These factors conspired to induce repeated shutdowns of the DIB heat pump and the column it served during the summer. The outages were undesirable because of their negative effect on the unit and production, but also because they were unpredictable and recurring. Compressor The heat pump compressor was central to the investigation though its importance was diminished by later discoveries. Figure 4 is a sketch of the compressor with its minimum flow or surge control loop, also called a kickback. A flow meter on the compressor outlet opens the minimum flow loop if necessary to maintain compressor throughput above surge. Kickback loops often have a means to cool the compressor discharge thereby removing the heat of compression. If this is not done, as it is omitted in our case, the hot flow recycled to the compressor suction is heated to a higher temperature upon being compressed again by the machine. This quickly results in a compressor discharge temperature that threatens to damage the equipment. A high outlet temperature shutdown is in place to trip the machine for its protection. Every indication was that this sequence of events was causing the warm weather compressor trips. But what was causing the compressor flow to drop off? The compressor driver is a gas turbine. Gas turbines lose Horsepower in warm weather as air density decreases with rising temperature. This can partially be offset with scrubbing the inlet air with water which cools and humidifies the air (evaporative coolers). Since the failures occurred during the heat of summer, a warm air related Horsepower loss could be a factor. However, after allowing for this effect the driver still should have been able to meet production rates. Something else had to be at work. Gas turbines, simplified jet engines, wear and foul over time. Both mechanisms deteriorate the drive's capacity. Periodic water washing can restore part of the Horsepower lost to fouling, but over time unrecoverable losses buildup. The drive in this case was at its recommended overhaul point. Therefore it was known to be sub par when compared with design. These are real capacity losses that can be tracked over time and certainly an 3
5 overhaul was due. But the question was whether or not to overhaul the existing driver or replace it with a larger one. Again, allowing for the effect of end-of-run deterioration, the compressor should not have been tripping off-line. Hydraulics and Heat Exchange As it leaves the compressor, the DIB overhead stream is now hot enough and at a high enough pressure to condense in the DIB reboiler. The compressor discharge is sent to the DIB Reboiler (E-1) where it condenses before entering the DIB Reflux Drum (V-1). The DIB Reboiler also receives heat from the Debutanizer Overhead. Employing the heat pump and two process heat sources to reboil the DIB provided excellent energy efficiency. Still, something was going awry in the summer. The DIB reflux is cooled by an air-cooler and water cooler before it enters the column. Unfortunately, the water cooled exchanger had been out of service for some time due to tube leaks. This outage increased the compressor load approximately four percent versus it being in operation using hot summertime water. Together with the compressor driver capacity reductions due to hot air intake and end-of-run fouling, a case was building to explain the compressor trips. Certainly improving any or all of these items would upgrade compressor performance. But the accumulation of these constraints seemed to suggest a tower throughput limitation. They did not suggest the compressor would just unexpectedly shutdown. A hint to the true cause of the problem came when an operator mentioned that the DIB reflux drum (V-1) PSV lifted intermittently during the summer. Normally the DIB Reflux Drum operated at a pressure comfortably away from its PSV set pressure. Since it was an equilibrium drum, its pressure was determined by the temperature and composition of the material within. If the upstream Depropanizer were slipping lights to the Debutanizer the DIB overhead composition would change and the DIB Reflux Drum would pressure up. But this problem was never seen. The DIB overhead Isobutane concentration was high and very steady. The temperature in the drum must be increasing to pressure up V-1. What could cause the temperature in V-1 to rise? Some change in the DIB Reboiler was the only possible source of a substantial adjustment of the V-1 temperature. The Reboiler could be fouled, but it seemed unlikely as fouling was not something that would come and go with the sunshine. E-1 would be affected by a DIB bottoms composition change and by a DIB column pressure change. But neither of these things occurred. What was left then was the Debutanizer Overhead stream. Both the Debutanizer Overhead and the DIB Overhead enter E-1 to supply heat to the DIB. A shift in reboiler heat duty from the DIB Overhead stream to the Debutanizer Overhead would warm V-1. Additionally it might prevent the DIB Overhead from fully condensing in E- 1. This would lead to much higher pressure drops from E-1 to V-1. A composition change in the Debutanizer Overhead would result in a higher temperature that would affect E-1 operation. However, the culprit was identified as the Debutanizer pressure after walking past the Debutanizer Overhead Air-Cooler (E-2). 4
6 The Debutanizer Overhead Air-Cooler capacity had waned over the years. It was a large bank of coolers part of which had been taken out of service. Dirt and dust from the surrounding environment had fouled the fins. The old boy just wasn't what he used to be. Since there was adequate reboiler capacity, operations compensated for this by increasing the Debutanizer pressure in the summer. This worked very well. Debutanizer capacity was not impacted by warm weather. However, the deleterious effect on the DIB was not obvious. Increasing the column pressure at constant composition raises the overhead temperature. This increases the Debutanizer stream temperature driving force in E-1 thereby shifting duty away from the DIB Overhead. This resulted in two-phase flow from E- 1 to V-1 and in higher temperatures in V-1. Both of these effects raised the required compressor discharge pressure. Table 1 details necessary compressor discharge pressures for several scenarios. The Hot Weather case is deemed 'hypothetical' because it is really worse than shown in the table, though a compressor head 26% greater than design is bad enough. As soon as the process is unable to condense all the DIB Overhead Stream in E-1, vapor begins to travel to V-1. This vapor has no way of leaving the drum. Pressure builds until the PSV lifts behavior noted by operations. At the same time the compressor must push against a higher and higher delivery pressure and rising two-phase frictional losses. This higher head requirement moves the compressor back on its curve until its flow drops off enough to activate the minimum flow loop. This recirculated flow leads to a high temperature discharge trip. It happens rapidly and with no apparent reason. Figure 5 illustrates the vapor pressures of both column's overhead streams. These relationships define the importance of the E-1 heat balance. For example, a 10 F increase in V-1 temperature results in a V-1 pressure increase of ~15 psi. That is 26% of the compressor design head. And moving the V-1 temperature ten degrees is not that hard. Increasing the Debutanizer pressure 10 psi increases its overhead temperature ~10 F. Though not one for one, the Debutanizer Overhead temperature and the V-1 temperature are closely coupled. A seemingly small change in the Debutanizer pressure can easily overload the DIB compressor. Slowly over time unit operation had deteriorated revealing a process complexity that was always there but not apparent. The Debutanizer overhead was shutting down the plant when its temperature rose in the summer. It is not unusual for equipment to degrade over time: Compressor driver at end-of-run cannot produce start-of-run Horsepower. Reflux water cooled exchanger out-of-service due to tube failures. Air-cooler fin fouling and partially out-of-service. It also is not unusual to equate mitigation of these types of deficiencies with cost. Why fix these things? That just raises maintenance expenditures. In the end the choice was between spending a lot of money on a new compressor driver that might not do the job, and spending a little money on engineering that might turf up another answer. After reviewing the findings, the plant decided not to install the costly upgraded compressor driver. Rather they overhauled the existing driver, and cleaned and maintained their 5
7 exchanger systems. A new, larger compressor driver would have cost over ten times the cost of the engineering study and resulting maintenance AND it would not have improved the operation at all. The plant is back running through the summer months still sweating with the warmth, but with equipment that can take the heat! 6
8 Cool Utility Feed Product Hot Utility Figure 1 Traditional Column Product 7
9 Feed Product Figure 2 Heat Pump Column Product 8
10 Table 1 Required Compressor Outlet Pressure Description Original Design Winter Warm Weather Hypothetical Hot Weather Percent of Design Feed Rate Required compressor pressure difference, psi Compressor P percent of design 100% 95% 107% 126% 9
11 SIC PIC Deisobutanizer CWS C M PIC FIC E-2 Flooded Condenser V-1 LIC Debutanizer M AI AI FIC From Depropanizer FIC FIC TIC i C4 LIC Steam AIC M Gasoline LIC FIC E-1 Bypass Flow M n C4 AI Figure 3 System 10
12 FIC SIC Figure 4 - Compressor 11
13 Vapor Pressure, psia DIB Ovhd Debutanizer Ovhd Temperature, F Figure 5 Column overhead vapor pressures 12
14 Author Biography Don Schneider Don Schneider is President of Stratus Engineering, Inc., Houston, Texas. Previously he worked as a senior engineer for Stone & Webster Engineering, and as an operating and project engineer for Shell Oil Co. He holds a B.S. from the University of Missouri-Rolla, and an M.S. from Texas A&M University, both in chemical engineering. Don has authored or coauthored over a dozen technical papers and articles and is a registered professional engineer in Texas. Author's Previous Publications Improve Catalyst Removal Methods, D. Schneider, Hydrocarbon Processing, October, Practical Process Hydraulics Considerations, D. Schneider, M. C. Hoover, Hydrocarbon Processing, August, Plant Power Failure and its Indirect Effects: a Case Study, D. Schneider, Petroleum Technology Quarterly, Winter 1998/99. Select the Right Hydrocarbon Molecular Weight Correlation, D. Schneider, Chemical Engineering Progress, December, Steady-State Simulators for Design, D. Schneider, Chemical Processing, December, Build a Better Process Model, D. Schneider, Chemical Engineering Progress, April, "Deep Cut Vacuum Tower Processing Provides Major Incentives, D. Schneider, J. Musumeci, Hydrocarbon Processing, November, "Debottlenecking Options and Optimization," D. Schneider, Petroleum Technology Quarterly, Autumn "Programming, It's not Just for Programmers Anymore," D. Schneider, Chemical Engineering, May, Deep Cut Vacuum Tower Incentives for Various Crudes, D. Schneider, J. Musumeci, L. Suarez, the AIChE 1997 Spring Nat l Mtg. Process Simulation: Matching the Computer s Perception to Reality, D. Schneider, the AIChE 1997 Spring Nat l Mtg. Debottlenecking Economics - Maximizing Profitability with Minimum Capital, D. Schneider, the NPRA 1997 Annual Mtg. Analysis of Alky Unit DIB Exposes Design, Operating Considerations, D. Schneider, J. Musumeci, R. Chavez, Oil & Gas Journal, September 30, How to Calculate Purge Gas Volumes, D. Schneider, Hydrocarbon Processing, November, 1993.
PRACTICAL PROCESS HYDRAULICS CONSIDERATIONS
PRACTICAL PROCESS HYDRAULICS CONSIDERATIONS by Donald F. Schneider, PE Chemical Engineer Stratus Engineering, Inc. Houston, Texas M. Chris Hoover Mechanical Engineer Koch Industries Wichita, Kansas Stratus
Optimization of Natural Gas Processing Plants Including Business Aspects
Page 1 of 12 Optimization of Natural Gas Processing Plants Including Business Aspects KEITH A. BULLIN, Bryan Research & Engineering, Inc., Bryan, Texas KENNETH R. HALL, Texas A&M University, College Station,
C. starting positive displacement pumps with the discharge valve closed.
KNOWLEDGE: K1.04 [3.4/3.6] P78 The possibility of water hammer in a liquid system is minimized by... A. maintaining temperature above the saturation temperature. B. starting centrifugal pumps with the
How To Make A High Co 2 Gas Blend
ECONOMICAL OPTION FOR CO 2 / METHANE SEPARATION IN PRODUCED GAS CONTAINING A HIGH CO 2 FRACTION F. Patrick Ross, P.E. TPR Consulting 9907 Sagecourt Drive Houston, Texas 77089 (713) 870-9208 [email protected]
Equipment Performance Monitoring
Equipment Performance Monitoring Web-based equipment monitoring cuts costs and increases equipment uptime This document explains the process of how AMS Performance Monitor operates to enable organizations
5.2. Vaporizers - Types and Usage
5.2. Vaporizers - Types and Usage 5.2.1. General Vaporizers are constructed in numerous designs and operated in many modes. Depending upon the service application the design, construction, inspection,
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences
Integrated Performance and Condition Monitoring at DuPont
Integrated Performance and Condition Monitoring at DuPont Monitoring systems have evolved from standing a nickel on its edge on top of the machine bearing cover or holding a screwdriver to one s temple,
Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.
I Dave s Statement If the thermostat calls for cooling, and the furnace fan is running properly, and the coil airflow is adequate, and the condenser fan is running properly, and the condenser airflow is
NATURAL GAS EXPERIENCE
02 NATURAL GAS EXPERIENCE Linde Process Plants, Inc. (LPP) has constructed NGL Plants since 1969 using traditional processes as well as the more advanced CRYO-PLUS technology. CRYO-PLUS TM Proprietary
Dynamic Models Towards Operator and Engineer Training: Virtual Environment
European Symposium on Computer Arded Aided Process Engineering 15 L. Puigjaner and A. Espuña (Editors) 2005 Elsevier Science B.V. All rights reserved. Dynamic Models Towards Operator and Engineer Training:
Lecture 9 Solving Material Balances Problems Involving Non-Reactive Processes
CHE 31. INTRODUCTION TO CHEMICAL ENGINEERING CALCULATIONS Lecture 9 Solving Material Balances Problems Involving Non-Reactive Processes Component and Overall Material Balances Consider a steady-state distillation
Modelling and Simulation of the Freezing Systems and Heat Pumps Using Unisim Design
Modelling and Simulation of the Freezing Systems and Heat Pumps Using Unisim Design C. Patrascioiu Abstract The paper describes the modeling and simulation of the heat pumps domain processes. The main
Refrigeration Basics 101. By: Eric Nelson
Refrigeration Basics 101 By: Eric Nelson Basics Refrigeration is the removal of heat from a material or space, so that it s temperature is lower than that of it s surroundings. When refrigerant absorbs
Why and How we Use Capacity Control
Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,
Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures
Data Realty Colocation Data Center Ignition Park, South Bend, IN Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures Project Overview Data Realty is a data center service provider for middle
Evaluation Of Hybrid Air- Cooled Flash/Binary Power Cycle
INL/CON-05-00740 PREPRINT Evaluation Of Hybrid Air- Cooled Flash/Binary Power Cycle Geothermal Resources Council Annual Meeting Greg Mines October 2005 This is a preprint of a paper intended for publication
The Piping System Model a New Life Cycle Document. Elements of the Piping System Model
Piping System Model as a Life Cycle Document White Paper Introduction When designing piping systems, a variety of documents are created providing the details necessary to design, purchase, build, and test
LEAN LNG PLANTS HEAVY ENDS REMOVAL AND OPTIMUM RECOVERY OF LIGHT HYDROCARBONS FOR REFRIGERANT MAKE-UP
LEAN LNG PLANTS HEAVY ENDS REMOVAL AND OPTIMUM RECOVERY OF LIGHT HYDROCARBONS FOR REFRIGERANT MAKE-UP Laurent Brussol Dominique Gadelle Arnaud Valade Process & Technologies Division Technip Paris La Défense
STEADY-STATE AND DYNAMIC SIMULATION OF CRUDE OIL DISTILLATION USING ASPEN PLUS AND ASPEN DYNAMICS
Petroleum & Coal ISSN 1337-7027 Available online at www.vurup.sk/pc Petroleum & Coal 51 (2) 100-109, 2009 STEADY-STATE AND DYNAMIC SIMULATION OF CRUDE OIL DISTILLATION USING ASPEN PLUS AND ASPEN DYNAMICS
Design Guidelines for Using Distillation Simulation Software in the Field
Design Guidelines for Using Distillation Simulation Software in the Field Karl Kolmetz KLM Technology Group Asit Mardikar Harpreet Gulati Invensys Process Systems (SimSci-Esscor) Dr Wai Kiong Ng Tau Yee
Dry-out Design Considerations and Practices for Cryogenic Gas Plants
Dry-out Design Considerations and Practices for Cryogenic Gas Plants Presented at the 93 rd Annual Convention of the Gas Processors Association April 14, 2014 Dallas, Texas Joe T. Lynch, P.E., David A.
In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil
In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil Answer: (1) Condenser coil See the video. A.R.E. Building Systems Study Guide
How To Clean Up A Reactor Water Cleanup
General Electric Systems Technology Manual Chapter 2.8 Reactor Water Cleanup System TABLE OF CONTENTS 2.8 REACTOR CLEANUP SYSTEM... 1 2.8.1 Introduction... 2 2.8.2 System Description... 2 2.8.3 Component
Long-Term Demonstration of CO2 Recovery from the Flue Gas of a Coal-Fired Power Station
Long-Term Demonstration of CO2 Recovery from the Flue Gas of a Coal-Fired Power Station MASAKI IIJIMA* 1 SHOJIRO IWASAKI* 1 SHINYA KISHIMOTO* 1 TORU TAKASHINA* 2 SUSUMU OKINO* 2 There is now a growing
Optimization of Water - Cooled Chiller Cooling Tower Combinations
Optimization of Water - Cooled Chiller Cooling Tower Combinations by: James W. Furlong & Frank T. Morrison Baltimore Aircoil Company The warm water leaving the chilled water coils is pumped to the evaporator
The. Brendan P. Sheehan, Honeywell Process Solutions, USA, and Xin Zhu, UOP, a Honeywell Company, USA, explore energy optimisation in plant processes.
The Brendan P. Sheehan, Honeywell Process Solutions, USA, and Xin Zhu, UOP, a Honeywell Company, USA, explore energy optimisation in plant processes. The global trends and challenges driving the need for
Understanding ejector systems necessary to troubleshoot vacuum distillation
TECHNOLOGY Understanding ejector systems necessary to troubleshoot vacuum distillation A complete understanding of ejector system performance characteristics can reduce the time and expense associated
Comparative Economic Investigation Options for Liquefied Petroleum Gas Production from Natural Gas Liquids
American Journal of Chemical Engineering 2015; 3(2-1): 55-69 Published online June 29, 2015 (http://www.sciencepublishinggroup.com/j/ajche) doi: 10.11648/j.ajche.s.2015030201.17 ISSN: 2330-8605 (Print);
Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.
Table V Troubleshooting Checklist for Refrigeration Systems TROUBLE POSSIBLE CAUSE CORRECTIVE MEASURE High condensing pressure. Low condensing pressure. Air or non-condensable gas in system. Inlet water
VACUUM REFRIGERATION SYSTEMS
VACUUM REFRIGERATION SYSTEMS CHILL VACTOR The Croll-Reynolds CHILL-VACTOR is a chiller that uses a vapor flashing process. Water has a pressure-temperature relationship which is its boiling point. If its
IBP 2778_10 HIGH EFFICIENCY ON CO2 REMOVAL IN NATURAL GAS WITH UCARSOL SOLVENTS Thiago V. Alonso 1. Abstract. 1. Introduction
IBP 2778_10 HIGH EFFICIENCY ON CO2 REMOVAL IN NATURAL GAS WITH UCARSOL SOLVENTS Thiago V. Alonso 1 Copyright 2010, Brazilian Petroleum, Gas and Biofuels Institute - IBP This Technical Paper was prepared
ECONOMICAL OPTIONS FOR RECOVERING NGL / LPG AT LNG RECEIVING TERMINALS
ECONOMICAL OPTIONS FOR RECOVERING NGL / LPG AT RECEIVING TERMINALS Presented at the 86 th Annual Convention of the Gas Processors Association March 13, 2007 San Antonio, Texas Kyle T. Cuellar Ortloff Engineers,
Fact Sheet Technology. Bergius-Pier Process (1)
tec Energy Technology Projects Subject: Bergius 1: 1924 1945 Rev: April 2006 Fact Sheet Technology The information included in this document is property of. Use and reproduction of this document, without
Automobile Air Conditioning Primer
Automobile Air Conditioning Primer An air conditioner is basically a refrigerator without the insulated box. It uses the evaporation of a refrigerant, like Freon, to provide cooling. The mechanics of the
ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric energy and heat -
Doc. : 08C00031_e Date : 10.02.2009 Page : 1 / 9 ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric - (Preliminary) Doc. : 08C00031_e
20,000 Barrel Per Day Crude Oil Refinery
20,000 Barrel Per Day Crude Oil Refinery (For Sale) AT THE EXCEPTIONAL PRICE OF $39,500,000.00 PRICE INCLUDES SHIPPING AND INSTALLATION Includes 2- TEN T B/D DISTILLILATION UNITS (SELLER NEEDS TO SELL
Thermal Coupling Of Cooling and Heating Systems
This article was published in ASHRAE Journal, February 2011. Copyright 2011 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Posted at www.ashrae.org. This article may not
Analysis of data centre cooling energy efficiency
Analysis of data centre cooling energy efficiency An analysis of the distribution of energy overheads in the data centre and the relationship between economiser hours and chiller efficiency Liam Newcombe
Introduction to Process Engineering Economics. based on size of major equipment items allow to decide whether to invest in a detailed study
Reliability of estimates Accuracy versus cost Cost structure for building a new plant Typical plant cost evaluation methods Lang's factors Happel's method Chauvel-Guthrie's method Examples and applications
How To Make A Mine Guard Fosil Process
UOP Amine Guard TM FS Technology for Acid Gas Removal 2009 UOP LLC. All rights reserved. UOP 5241B-01 Agenda Overview of the Amine Guard FS process UCARSOL TM Solvent characteristics Amine Guard FS flow
White Paper #10. Energy Efficiency in Computer Data Centers
s.doty 06-2015 White Paper #10 Energy Efficiency in Computer Data Centers Computer Data Centers use a lot of electricity in a small space, commonly ten times or more energy per SF compared to a regular
ABSTRACT. aspects of potential waste heat recovery systems and the economics of installing them at selected survey factories.
ABSTRACT WASTE HEAT RECOVERY IN THE FOOD PROCESSING INDUSTRY W. L. Lundberg and J. A. Christenson Westinghouse Electric Corporation Advanced Energy Systems Division F. Wojnar H. J. Heinz Company U.S.A.
CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS
CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS BULLETIN 240-10-3 June 2004 Supersedes June 1983 Many centrifugal systems get little maintenance. As a result they operate with the refrigerant highly contaminated
Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:
Current state of plant Functioning as a peak and emergency centre Statistics Accumulated operating hours: D1-2-3-6-7: 43000 to 48000 hrs D4-5: 53000 to 57000 hrs D8: 33000 hrs Layout of the plant Index:
Performance Monitoring For Gas Turbines
Performance Monitoring For Gas Turbines Introduction Managing an asset requires numerous technologies designed to assess health. While most gas turbines in the field are fitted with some type of mechanical
Troubleshooting an Air Conditioning system. R D Holder Eng. Roger D Holder MSME
Troubleshooting an Air Conditioning system R D Holder Eng. Roger D Holder MSME Troubleshooting of an air conditioning system is a step by step procedure. I have found that a 4 step procedure is the best
It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.
The System Evaluation Manual and Chiller Evaluation Manual have been revised and combined into this new book; the Air Conditioning and Refrigeration System Evaluation Guide. It will be available soon as
Production of R-134a
Production of R-134a Background In the 1930 s, chlorofluorocarbons (CFC s) were developed as a supposedly safe alternative to ammonia and sulfur dioxide refrigerants. While sulfur dioxide is toxic and
Turbo Tech 101 ( Basic )
Turbo Tech 101 ( Basic ) How a Turbo System Works Engine power is proportional to the amount of air and fuel that can get into the cylinders. All things being equal, larger engines flow more air and as
Heat Trace Fundamentals. Monte Vander Velde, P.E. President, Interstates Instrumentation
Heat Trace Fundamentals Monte Vander Velde, P.E. President, Interstates Instrumentation Contents Introduction... 3 Purpose of Heat Trace... 3 Types of Heat Trace... 4 Steam Trace vs. Electric Trace...
Engineering Recommendation on: Accumulators Revised 6-17-99 Issued January 10, 1979 Page 1 of 7
Issued January 10, 1979 Page 1 of 7 Accumulators have long been recognized by the industry as an effective means of maintaining good system balance by storing excess refrigerant as the condenser or evaporator
Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur
Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur Lecture No. # 22 Refrigeration System Components: Compressor (Continued)
Natural gas liquids recovery from gas turbine fuel
Natural gas liquids recovery from gas turbine fuel By Simone Amidei, Francesca Monti, Riccardo Valorosi / GE Oil & Gas GE imagination at work Natural gas liquids recovery from gas turbine fuel By Simone
PERFORMANCE EVALUATION OF NGCC AND COAL-FIRED STEAM POWER PLANTS WITH INTEGRATED CCS AND ORC SYSTEMS
ASME ORC 2015 3rd International Seminar on ORC Power Systems 12-14 October 2015, Brussels, Belgium PERFORMANCE EVALUATION OF NGCC AND COAL-FIRED STEAM POWER PLANTS WITH INTEGRATED CCS AND ORC SYSTEMS Vittorio
Liquefied Natural Gas (LNG)
Graduate Diploma in Petroleum Studies Major in Liquefied Natural Gas (LNG) INDUCTION Launching ceremony Week 39, 2012 Administration / Plant visit / Fundamentals of LNG and LNG main risks awareness Module
GEOTHERMAL POWER GENERATION A PRIMER ON LOW-TEMPERATURE, SMALL-SCALE APPLICATIONS
GEOTHERMAL POWER GENERATION A PRIMER ON LOW-TEMPERATURE, SMALL-SCALE APPLICATIONS by Kevin Rafferty Geo-Heat Center January 2000 REALITY CHECK Owners of low-temperature geothermal resources are often interested
Dharam V. Punwani President, Avalon Consulting, Inc. Presented at Turbine Inlet Cooling Association Webinar April 9, 2014
Dharam V. Punwani President, Avalon Consulting, Inc. Presented at Turbine Inlet Cooling Association Webinar April 9, 2014 Background: What is the problem that needs a solution? What is Turbine Inlet Cooling
COMMERCIAL HVAC EQUIPMENT. Condensers and Cooling Towers
COMMERCIAL HVAC EQUIPMENT Condensers and Cooling Towers Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application topics.
ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014
ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014 Explanation of the refrigeration cycle. Compressors. Benefits and operating characteristics. -Reciprocating
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries Hot tips and cool ideas to save energy and money! Air conditioning units or systems are often used by foundries
HEATING, VENTILATION & AIR CONDITIONING
HEATING, VENTILATION & AIR CONDITIONING as part of the Energy Efficiency Information Grants Program Heating and cooling can account for approximately 23 % of energy use in pubs and hotels 1. Reducing heating
OPTIMIZING CONDENSER WATER FLOW RATES. W. A. Liegois, P.E. Stanley Consultants, Inc. Muscatine, Iowa
OPTIMIZING CONDENSER WATER FLOW RATES W. A. Liegois, P.E. Stanley Consultants, Inc. Muscatine, Iowa T.A. Brown, P.E. Thermal Energy Corporation Houston, Texas ABSTRACT Most chillers are designed for a
UNIT 2 REFRIGERATION CYCLE
UNIT 2 REFRIGERATION CYCLE Refrigeration Cycle Structure 2. Introduction Objectives 2.2 Vapour Compression Cycle 2.2. Simple Vapour Compression Refrigeration Cycle 2.2.2 Theoretical Vapour Compression
The Different Types of Air Conditioning Equipment for IT Environments
The Different Types of Air Conditioning Equipment for IT Environments By Tony Evans White Paper #59 Executive Summary Cooling equipment for an IT environment can be implemented in 10 basic configurations.
********** An short and simple explanation of how oil is converted into gasoline and then brought to you, the consumer.
********** An short and simple explanation of how oil is converted into gasoline and then brought to you, the consumer. CEC-180-2008-008 July 2008 CONTENTS [St e p 1 ] SOURCES [Step 2] extraction **************
Why use Tigerloop in fuel heating systems?
The Original Oil De-aerator Why use Tigerloop in fuel heating systems? Reliability New products are continually being developed in the modern oil heating industry in order to satisfy new laws and regulations
UNDERSTANDING REFRIGERANT TABLES
Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016 UNDERSTANDING REFRIGERANT TABLES INTRODUCTION A Mollier diagram is a graphical representation of the properties of a refrigerant,
POLICY BULLETIN Tecumseh Compressor Company Compressor Group
to Bulk Milk Coolers and Other System Page 1 of 5 Overall reliability can be enhanced if there exists a complete understanding of the features, system design, installation requirements, processing, charging
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction
Routinely surveying tower overhead vacuum systems can
Troubleshooting crude vacuum tower overhead ejector systems Use these guidelines to improve performance and product quality J. R. LINES AND L. L. FRENS, GRAHAM MANUFACTURING CO. INC., BATAVIA, NEW YORK
Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415. Table of Contents
Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415 Table of Contents WORK COVERED... 2 WORK NOT COVERED...2 TITLES... 2 GRADE LEVELS... 2 HELPER AND INTERMEDIATE JOBS...
How To Understand Evaporator
SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES After studying this unit, the reader should be able to Define high-, medium-, and low-temperature refrigeration.
The Challenge of Integrating Non-Continuous Processes Milk Powder Plant Case Study
The Challenge of Integrating Non-Continuous Processes Milk Powder Plant Case Study Martin Atkins, Michael Walmsley, James Neale Energy Research Group, University of Waikato Private Bag 315, Hamilton, New
GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101
GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101 By Jim VanderGiessen Jr, Pro Refrigeration Inc. There is a good chance your glycol chiller system is often completely forgotten about, until that dreaded day you
Air-Conditioning Buying Guide
Air-Conditioning Buying Guide Buying a new air-conditioning system is a big decision. This Air-Conditioning Buying Guide can help you make the right choice, save energy and money. Shop with confidence
EFFICIENT ENERGY SUPPLY (ELECTRICITY AND DISTRICT HEAT) FOR THE CITY OF LINZ
Parallel session Producing more with less: Efficiency in Power Generation EFFICIENT ENERGY SUPPLY (ELECTRICITY AND DISTRICT HEAT) FOR THE CITY OF LINZ Johann Gimmelsberger Linz Strom GmbH EFFICIENT ENERGY
Variable Capacity Compressors, a new dimension for refrigeration engineers to explore
Variable Capacity Compressors, a new dimension for refrigeration engineers to explore By: Marcos G. Schwarz, VCC Group Leader Corporate Research & Development, EMBRACO SA Abstract: This paper presents
Enhancing Process Control Education with the Control Station Training Simulator
Enhancing Process Control Education with the Control Station Training Simulator DOUG COOPER, DANIELLE DOUGHERTY Department of Chemical Engineering, 191 Auditorium Road, Room 204, U-222, University of Connecticut,
CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
A Focus on Balance A Novel Approach Taking the Phillips Optimized Cascade LNG Process Into the Future
74b A Focus on Balance A Novel Approach Taking the Phillips Optimized Cascade LNG Process Into the Future Wesley R. Qualls ConocoPhillips, LNG Technology Licensing Philip Hunter Bechtel Corporation, Petroleum
Low GWP Replacements for R404A in Commercial Refrigeration Applications
Low GWP Replacements for R404A in Commercial Refrigeration Applications Samuel YANA MOTTA, Mark SPATZ Honeywell International, 20 Peabody Street, Buffalo, NY 14210, [email protected] Abstract
Ground Source Heat Pumps The Fundamentals. Southington, Connecticut 860 628 4622 John F. Sima III P.E.
Ground Source Heat Pumps The Fundamentals Southington, Connecticut 860 628 4622 John F. Sima III P.E. Winter/Spring 2010 Ground Source Heat Pumps The Fundamentals TOPICS: Heat Pump Terminology Basic Physics
Acetaldehyde Production by Ethanol Dehydrogenation
Acetaldehyde Production by Ethanol Dehydrogenation Background Acetaldehyde is a colorless liquid with a pungent, fruity odor. It is primarily used as a chemical intermediate, principally for the production
Making the Most of SáOá SM Services
MAINTENANCE PRODUCTS AND SERVICES Making the Most of SáOá SM Services With S O S Services, you don t just get test results, you get accurate analysis from the people who know your Cat equipment best. Your
Practical Implementation of Safety Management Systems at Unregulated Upstream Oil & Gas Facilities
Practical Implementation of Safety Management Systems at Unregulated Upstream Oil & Gas Facilities Kristin D. Norton, PE CFSE Risk Management Professionals, Inc. 300 Goddard, Suite 200 Irvine, California
DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS
DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS J J Brasz, Carrier Corporation, Syracuse, NY, 13221, USA [email protected] I K Smith and N Stosic
By Steven C. Severini, P.E., Member ASHRAE
The following article was published in ASHRAE Journal, July 2004. Copyright 2004 American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. It is presented for educational purposes
Oil Refinery Processes A Brief Overview
Oil Refinery Processes A Brief Overview Ronald (Ron) F. Colwell, P.E. Some Historical Events 3000 BC Sumerians use asphalt as an adhesive; Eqyptians use pitch to grease chariot wheels; Mesopotamians use
Design Procedure. Step 2: The simulation is performed next. Usually the column is not difficult to converge, as the liquid reflux ratio is large.
Design Procedure We now summarize the technique for designing a multipurpose energy efficient atmospheric column. First, the Watkins design method is used to obtain an initial scheme without pump-around
HOW TO SELECT A LOW VOLUME (L.V ) BOILER
HOW TO SELECT A LOW VOLUME (L.V ) BOILER FREQUENTLY ASKED QUESTIONS OR COMMENTS ON BOILERS Dear Potential Customer: Low Volume Operator Exempt boilers have been marketed in Ontario to eliminate the requirement
Recommended Practice for Software Acquisition
Recommended Practice for Software Acquisition PSIG 003/2000 Objective: To develop a set of practices that may be used in the acquisition of pipeline simulation software. Pipeline Simulation Interest Goup,
Chapter 3.4: HVAC & Refrigeration System
Chapter 3.4: HVAC & Refrigeration System Part I: Objective type questions and answers 1. One ton of refrigeration (TR) is equal to. a) Kcal/h b) 3.51 kw c) 120oo BTU/h d) all 2. The driving force for refrigeration
Exergy: the quality of energy N. Woudstra
Exergy: the quality of energy N. Woudstra Introduction Characteristic for our society is a massive consumption of goods and energy. Continuation of this way of life in the long term is only possible if
ON-VEHICLE INSPECTION
Sight Glass I11244 ONVEHICLE INSPECTION 1. INSPECT REFRIGERANT VOLUME Observe the sight glass on the liquid tube. AC3 AC22F05 Test conditions: Running engine at 1,500 rpm Blower speed control switch: HI
Glossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
UTILITIES DEPARTMENT NORTH CAMPUS DISASTER RECOVERY PLAN
Page 1 of 27 UTILITIES DEPARTMENT NORTH CAMPUS DISASTER RECOVERY PLAN Page 2 of 27 Table of Contents 1. OBJECTIVE... 4 2. SCOPE... 4 3. COMMUNICATION... 4 4. LOSS OF NATURAL GAS SUPPLY... 5 5. LOSS OF
No. Name Description Main input Data Main Output Data. cooling duty, process in/out temperature, inlet air temperature
1 AIRCOOLER Air cooler preliminary sizing cooling duty, process in/out temperature, inlet air temperature No of fans, Air cooler Dimension, bare area, no of rows, Fan Diameter, fan power 2 BLOW DOWN FACILITATOR
HVAC Systems: Overview
HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct