Monitor Access Unit JUNE 1999 TS760A TS761A TS765A TS766A CUSTOMER SUPPORT INFORMATION



Similar documents
Remote Port USB Port User Guide

Voice Magic Plus MARCH 2001 CP179A CUSTOMER SUPPORT INFORMATION

Fiber Optic Converter I Fiber Optic Converter II

Use this HDMI and HDCP-compliant USB converter for streaming media files stored on BLACK your PC to BOX an HD screen with HDMI input.

Copyright Black Box Corporation. All rights reserved.

BLACK BOX Works with the Black Box ServReach KVM Gate (KVIP1000A), ServReach KVM Cube (KVIP1001A), or as a standalone device.

High specification KVM switches that interface precisely with the Black Box ServView Rack Tray series.

Quick Start Guide. Rackmount Remote Power Manager. Use this guide to quickly set up your power manager. Customer Support Information

BLACK BOX. Switch between two or four different HDMI sources to a single display. 2 x 1 or 4 x 1 HDMI Switch 4K VSW-HDMI2X1-4K VSW-HDMI4X1-4K

User Manual. ipad, Chromebook, Tablet, and Laptop Lockers. Mobile, secure, and powered storage for up to 40 computing devices.

Send VGA output to one local monitor and to as many as nine remote monitors BLACK up to 250 BOX feet (76.2 m) away.

Black Box Tech Support: FREE! Live. 24/7.

JANUARY 2001 TS825A TS826. Microscanner Pro

10BASE-T Extender. 10BASE-T Extender FEBRUARY 1999 LZ6000A-R4. Jabber Link Test Activity. Power. Collision. Power 10BASE-T.

Black Box Tech Support: FREE! Live. 24/7.

2-Port DVI Switch with Audio, Serial Control & Long Cable Equalization

VDSL Line Driver DECEMBER 2006 ME0010A-VDSL-R2

Remote Console Port + Remote Power Manager. Quick Start Guide

Turns a VGA monitor into a video monitor with remote switching capability. BLACK BOX

Copyright Black Box Corporation. All rights reserved.

This Web smart switch provides /100-/1000-Mbps ports. BLACK BOX

Network Power Switch Jr.

Veri-NAC the fastest to deploy, easiest to use

USB Director RS422/RS485 Hub 2-Port USB Director RS422 Hub 4-Port NT 4.0 Software Support Upgrade

Extend Ethernet with full-duplex transmission up to Mbps more than BLACK four miles over BOX a pair of copper wires.

8-Port Serial Host Adapter PCI

VDSL Line Driver DECEMBER 2004 ME0010A-VDSL ME0011A-VDSL

Transform your wired projector into a high-end wireless projector.

Multi-Rate Ethernet Extender

Digi-Mux HS FEBRUARY 1996 MX700A CUSTOMER SUPPORT INFORMATION

Extend Ethernet with full-duplex transmission up to 10.8 Mbps over two pairs BLACK of copper. BOX

PC 422/485 Serial Interface

Connect, control, and manage up to 16 serial RS-232/485 devices BLACK BOX via a single USB port on your PC.

2-Port RS-232 PCI Bus Serial Host Adapter

User Manual. 30-Device ipad, Chromebook, Tablet, and Laptop Cart. Mobile, secure, and powered storage for up to 30 computing devices.

Express Ethernet Switches

Expand existing, leased line, polled networks without adding computer ports BLACK or communications links.

USB Single-Port Hub (RS-422/485)

Copyright Black Box Corporation. All rights reserved.

DeeSel.1 Industrial Ethernet Extender Multi-Drop Unit, G-SHDSL 2-Wire, 5.7 Mbps

RS-232/485 Converter

CAT5 Multi Video System (Video/Audio/RS232)

FOM Line Driver ST FOM Line Driver SM

Gigabit Compact Media Converter

Provides first-class HD video transmission

Short-Haul Modem-FSK RS-485 Modules

Video to VGA Converter/Switch

T1/E1 Fiberoptic Line Driver (T1/E1 FOLD)

Copyright Black Box Corporation. All rights reserved.

DSLAM Chassis: 1-x-4-Slot or 2-x-12-Slot DSL Access Multiplexor Uplink Module

Gigabit 1000BASE-SX/LX PCI 64-/32-Bit Fiber NICs

Pure Networking Broadband Router Users Guide

Extend 10/100Base-TX Ethernet up to 10,000 feet (3 km)

Secure Site Manager 8 Secure Site Manager 16 User s Guide

Internet Access Router

Network Management Software

RS-232/422/485 2-Port PCI Card, Opto-Isolated


LR120A, LR121A, LR122A, LR125A WAN Access Routers. Getting Started Guide

A high performance KVM extender that can transmit up to two high resolution DisplayPort video streams plus high speed USB and digital/ analog audio.

1101 and 1102 Secure Device Servers

Welcome to the ServSwitch Family!

Remote Console Manager User s Manual

2-Port RS-232/422/485 PCI Host Adapter

Terminal Server User Guide

BLACK BOX. Installation Guide. Hybrid PBX and VoIP Gateway with (4) or (12) FXOs

FIBER OPTIC A/B/C SWITCH (Latching)

4-, 8-, and 16-Port ServSwitch EC Series IP KVM Switch

SINGLE MODE FIBER OPTIC A/B SWITCH (LATCHING)

Cyclades-TS User Guide. Version TS 1.4.0

Supports http and SNMP interface for switch management.

JUNE USB Micro Extender ACU4001A ACU4201A ACU4222A

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

Quick Installation Guide TK-RP08. H/W: v1.0r

Transcription:

JUNE 1999 TS760A TS761A TS765A TS766A Monitor Access Unit MON 2 1 2 3 4 5 6 7 8 MON 1 CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com E-mail: info@blackbox.com

FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS FCC/IC STATEMENTS This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference. Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada. Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par Industrie Canada. 3

INSTRUCCIONES DE SEGURIDAD NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY STATEMENT INSTRUCCIONES DE SEGURIDAD 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura. 3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas. 4. Todas las instrucciones de operación y uso deben ser seguidas. 5. El aparato eléctrico no deberá ser usado cerca del agua por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc.. 6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante. 7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante. 8. Servicio El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado. 9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación. 10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor. 4

INSTRUCCIONES DE SEGURIDAD 11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato. 12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada. 13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato. 14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante. 15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia. 16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo. 17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación. 18. Servicio por personal calificado deberá ser provisto cuando: A: El cable de poder o el contacto ha sido dañado; u B: Objectos han caído o líquido ha sido derramado dentro del aparato; o C: El aparato ha sido expuesto a la lluvia; o D: El aparato parece no operar normalmente o muestra un cambio en su desempeño; o E: El aparato ha sido tirado o su cubierta ha sido dañada. 5

TRADEMARKS All applied-for and registered trademarks are the property of their respective owners. 6

CONTENTS Chapter Page 1. Specifications................................................. 8 2. Overview.................................................... 11 2.1 Introduction............................................ 11 2.2 Front Panel............................................. 12 2.3 Rear Panel.............................................. 13 2.4 Applications............................................. 14 3. Components................................................. 17 4. Installation.................................................. 19 4.1 Checklist............................................... 19 4.2 Installing the Hardware................................... 21 4.3 Installing the Software.................................... 29 5. Manual Operation............................................ 30 5.1 Connecting Test Devices................................... 30 5.2 Disconnecting Test Devices................................ 31 Appendix A: HDX250.DEF....................................... 32 7

1. Specifications Table 1-1. Network Interfaces. Model Connectors Networks Switched Leads TS760A (8) RJ-45 Ethernet 10BASE-T and 100BASE-T, All 8 leads. STP and UTP Token Ring. TS761A (16) RJ-45 Ethernet 10BASE-T and 100BASE-T, All 8 leads. STP and UTP Token Ring. TS765A (8) DB15 RS-232, RS-422/RS-423 (RS-449), All 15 leads. RS-530, V.10/V.11, V.35, and Ethernet AUI. TS766A (16) DB15 RS-232, RS-422/RS-423 (RS-449), All 15 leads. RS-530, V.10/V.11, V.35, and Ethernet AUI. Switches Button for each monitor port, button for each network port, CONFIG1 DIP switches, CONFIG2 DIP switches LEDs ON, for each network port, for each network port Connectors TS760A: (8) RJ-45, TS761A: (16) RJ-45, TS765A: (8) DB15, TS766A: (16) DB15 Relays Type: Sealed, latching; Contact material: Gold-clad silver, Initial contact resistance: 50 milliohms; Expected life: 10,000,000 operations Network Control ASCII character strings and VT100 terminal menus: Asynchronous; RS-232; 2400, 4800, 9600, or 19200 baud; No parity, 8 data bits, 1 stop bit, full duplex Network General s Sniffer Server Asynchronous; RS-232; 2400 baud; No parity, 8 data bits, 1 stop bit, full duplex 8

Table 1-2. COMM IN Pins (RJ-11). Pin Description Dir. MONITOR ACCESS UNIT 1 Not Used 2 Master/Slave In 3 Signal Ground 4 Receive Data Out 5 Transmit Data In 6 Not Used Table 1-3. COMM OUT Pins (RJ-11). Pin Description Dir. 1 Not Used 2 Master/Slave Out 3 Signal Ground 4 Receive Data In 5 Transmit Data Out 6 Not Used 9

System Capacity ASCII character strings and VT100 terminal menus: 64 daisy-chained units, with eight networks per unit; Network General s Sniffer Server: One unit, with eight or 16 networks Operating Temperature 32 to 104 F (0 to 40 C) Operating Humidity 0 to 95%, noncondensing Power 100-250 VAC, 56/60/440 Hz and 120-300 VDC 1A, automatically selected Power Socket IEC Size TS760A, TS765A: 1.75 H x 19 W x 11.4 D (4.5 x 48.3 x 28.9 cm); TS761A, TS766A: 3.5 H x 19 W x 11.4 D (8.9 x 48.3 x 28.9 cm) 10

2. Overview This manual tells you how to install and use the Monitor Access Unit with Network General Corporation s Distributed Sniffer Server System. If you are using a server system other than the Sniffer, call technical support for information on configuring and installing the Monitor Access Unit for use with your system. This chapter introduces you to the Monitor Access Unit, describes the front and rear panels, and describes some applications of the Monitor Access Unit with Network General s Sniffer Server. 2.1 Introduction The Monitor Access Unit allows you to easily and quickly connect test equipment to networks. Each Monitor Access Unit provides one test device with access to 8 or 16 networks. Four models are available: Monitor Access Unit with 8 RJ-45 connectors (part number TS760A) Monitor Access Unit with 16 RJ-45 connectors (part number TS761A) Monitor Access Unit with 8 DB15 connectors (part number TS765A) Monitor Access Unit with 16 DB15 connectors (part number TS766A) The Monitor Access Unit is designed to interface with Local Area Networks (LANs). It supports many types of networks, including the following: Ethernet: 10BASE-T, 100BASE-T, and AUI Token Ring: STP and UTP This manual describes system operation with Network General Corporation s Distributed Sniffer Server System. For operation with other types of control, such as the VT100 menu interface and ASCII control strings, call for technical support. This manual describes two model sizes: an 8 network port unit and a 16 network port unit. Both contain exactly the same functions. However, the 16 network port unit can connect to twice as many networks as the 8 network port unit. 11

For connecting test devices to networks, the Monitor Access Unit uses sealed latching relays. The use of relays ensures that the units are protocol and speed transparent. For added reliability, the relays have gold-clad silver contacts. In the event of power failure, the latching relays remain in the last switched position. This unit has been approved by Network General Corporation. 2.2 Front Panel Figure 2-1 shows the front panel, which includes the following: A power ON LED. The power ON LED lights when there is power supplied to the unit. Monitor switches. The monitor switches ( and ) allow you to connect or disconnect test equipment to or from networks. For operation with Network General s Sniffer Server, the monitor switches are disabled. Network switches. The network switches allow you to connect test equipment to networks. For operation with Network General s Sniffer Server, the network switches are disabled. LEDs indicate connections. ON ENABLE DISABLE ENABLE DISABLE MON 1 1 2 3 4 5 6 7 8 MON 2 Figure 2-1. Front Panel. 12

NOTE For use with Network General s Sniffer Server, the manual switches are disabled. 2.3 Rear Panel Figure 2-2 shows various rear panels, all of which include the following: Monitor ports: IN, IN, OUT, and OUT. The monitor ports allow you to connect test equipment to the unit. Network ports: 1 to 8 or 1 to 16. The network ports allow you to connect networks to the unit. DIP switches. For the 8-network port units, there are two blocks of DIP switches: CONFIG1 and CONFIG2. For the 16-network port units, there are four blocks of DIP switches: CONFIG1, CONFIG2, CONFIG3, and CONFIG4. These DIP switches allow you to configure the unit. COMM ports: COMM IN and COMM OUT. These ports allow you to connect a controlling device (the Distributed Sniffer Server) to the units. A chassis ground stud. A power socket. IN OUT IN OUT 1 2 3 4 PORT 5 6 7 8 CONFIG1 CONFIG2 IN COMM OUT OUT IN OUT IN 5 1 6 2 PORT 7 3 8 4 I N COMM CONFIG1 O U T CONFIG2 Figure 2-2. Rear view of the 8-network units, showing the different types of connectors (top to bottom): RJ-45 (Model TS760A) and DB15 (Model TS765A). 13

MON 1 1 2 3 4 5 6 7 8 MON 2 MONITOR ACCESS UNIT IN OUT IN OUT 1 2 3 4 PORT 5 6 7 8 CONFIG1 CONFIG2 IN COMM OUT IN OUT IN OUT 1 2 3 4 PORT 5 6 7 8 CONFIG1 CONFIG2 IN COMM OUT Figure 2-3. Rear view of the 16-network unit with RJ-45 connectors (Model TS761A). 2.4 Applications 1:8 Configuration (LAN) In Figure 2-4, a Monitor Access Unit connects one Sniffer Server to any of eight networks. The Sniffer Server controls the Monitor Access Unit, connecting itself to the networks, and performs the testing operations. Network Connection SniffMaster Console Monitor Card Sniffer Server Monitor Cable (included) MON 1 IN Monitor Access Unit Com-1 (DB9) Server Communication Cable (included) COMM IN (RJ-11) Up to 8 networks Figure 2-4. Sample Application, 1:8 Configuration. 14

You can use either of the following Monitor Access Units in this application: Table 2-1. 1:8 Configuration for the Monitor Access Units. Model Number Type of network that you can connect... TS760A Any network that uses RJ-45 connectors: Ethernet 10BASE-T, Ethernet 100BASE-T, STP Token Ring, UTP Token Ring, etc. TS765A Any network that uses DB15 connectors: RS-232, RS-422, RS-423, RS-449, RS-530, V.10-V.11, V.35, Ethernet AUI, etc. 15

MON 1 1 2 3 4 5 6 7 8 MON 2 MON 1 1 2 3 4 5 6 7 8 MON 2 MONITOR ACCESS UNIT 1:16 Configuration (LAN) In Figure 2-5, a Monitor Access Unit connects one Sniffer Server to any of 16 networks. The Sniffer Server controls the Monitor Access Unit, connecting itself to the networks, and performs the testing operations. Network Connection SniffMaster Console Monitor Card Sniffer Server Monitor Cable (included) Up to 8 networks COM 1 (DB9) Server Communication Cable (included) COMM IN (RJ-11) MON 1 IN Monitor Access Unit Up to 8 networks Figure 2-5. Sample Application, 1:16 Configuration. You can use either of the following Monitor Access Units in this application: Table 2-2. 1:16 Configuration for the Monitor Access Units. Model Number Type of network that you can connect... TS761A Any network that uses RJ-45 connectors: Ethernet 10BASE-T, Ethernet 100BASE-T, STP Token Ring, UTP Token Ring, etc. TS766A Any network that uses DB15 connectors: RS-232, RS-422, RS-423, RS-449, RS-530, V.10-11, V.35, Ethernet AUI, etc. 16

3. Components MONITOR ACCESS UNIT This chapter lists the Monitor Access Unit components that are used when operating with Network General s Sniffer Server. Table 3-1. Monitor Access Units. Model Connectors Networks Switched Leads TS760A (8) RJ-45 Ethernet 10BASE-T and All 8 leads. 100BASE-T, STP and UTP Token Ring. TS761A (16) RJ-45 Ethernet 10BASE-T and All 8 leads. 100BASE-T, STP and UTP Token Ring. TS765A (8) DB15 RS-232, RS-422/RS-423 All 15 leads. (RS-449), RS-530, V.10/ V.11, V.35, and Ethernet AUI. TS766A (16) DB15 RS-232, RS-422/RS-423 All 15 leads. (RS-449), RS-530, V.10/ V.11, V.35, and Ethernet AUI. Table 3-2. Control Cable. Model Description Included Server Communication Cable, DB9/RJ-11, Server 17

Table 3-3. Monitor Cable. Model Included Description Monitor Cable 18

4. Installation This chapter describes how to install the Monitor Access Unit for use in a system with Network General s Sniffer Server. 4.1 Checklist The following items are included with your order. If any items are missing or damaged, please contact your sales representative. TS760A and TS761A include: ❶ This user manual ❷ Server communication cable ❸ (2) Monitor cables ❹ Power cable ❺ Software ❶ ❷ ❸ ❹ ❺ Figure 4-1. TS760A and TS761A Package Contents. 19

TS765A and TS766A include: ❶ This user manual ❷ Server communication cable ❸ (2) Monitor cables ❹ Power cable ❺ Software ❶ ❷ ❸ ❹ ❺ Figure 4-2. TS765A and TS766A Package Contents. 20

4.2 Installing the Hardware To install the hardware, follow these steps: 1. Set the Unit Address DIP switches. NOTE If you change DIP switch settings, you must re-power the unit for the changes to take effect. Set the unit address DIP switches for the type of configuration that you are installing. If you are installing a 16-network unit, you must set the Unit Address DIP switches on both the top part of the unit and the bottom part of the unit. Switches 1 through 6 of the CONFIG2 DIP switches set the unit address. These switches are on the rear of the unit. Tables 4-1 and 4-2 give the DIP switch settings for each type of configuration. Figure 4-3 tells you how to set an individual DIP switch. Table 4-1. Switch Settings, Unit Address for 1:8 Configuration. Unit Config2 Switches 1 2 3 4 5 6 7 8 OFF OFF OFF OFF OFF OFF Table 4-2. Switch Settings, Unit Address for 1:16 Configuration. Unit Config2 Switches 1 2 3 4 5 6 7 8 TOP OFF OFF OFF OFF OFF OFF BOTTOM ON OFF OFF OFF OFF OFF 21

7 8 ON OFF Figure 4-3. Setting an Individual DIP Switch. To switch to the ON position, move the DIP switch toward the number labels on the unit. To switch to the OFF position, move the DIP switch away from the number labels. 22

2. Set the baud rate. NOTE If you change the DIP switch settings, you must re-power the unit for the changes to take effect. The baud rate must be set to 2400. Switches 7 and 8 of CONFIG2 (and CONFIG 4) set the baud rate. These switches are on the rear of the unit. Tables 4-3 gives the DIP switch settings. Figure 4-3 shows you how to set an individual DIP switch. Table 4-3. Baud Rate Switch Settings. Baud Rate Config2 Switches 1 2 3 4 5 6 7 8 2400 OFF OFF 3. Set the monitor port identifiers. NOTE If you change the DIP switch settings, you must re-power the unit for the changes to take effect. You must assign an identifier to each monitor port. Switches 1 through 6 of CONFIG1 set the monitor port identifiers. These switches are on the rear of the unit. Table 4-4 gives the DIP-switch settings. Figure 4-3 shows you how to set an individual DIP switch. Table 4-4. Port Identifier Switch Settings. Port IDs Config1 Switches 1 2 3 4 5 6 7 8 1 ON OFF OFF ON OFF OFF 23

4. Disable the front-panel buttons. NOTE If you change the DIP switch settings, you must re-power the unit for the changes to take effect. You must disable the front-panel buttons. To disable the buttons, set Switch 7 to ON. This switch is on the rear of the unit. Table 4-5 gives the DIP switch settings. Figure 4-3 tells you how to set an individual DIP switch. Table 4-5. Buttons Switch Settings. Config1 Switches Buttons 1 2 3 4 5 6 7 8 Disable ON 5. Set the unit for Sniffer control. NOTE If you change the DIP switch settings, you must re-power the unit for the changes to take effect. To set the unit for operation with Network General Corporation s Expert Sniffer Network Analyzer, set Switch 8 of the CONFIG1 DIP switch to ON. This switch is on the rear of the unit. Table 4-6 gives the DIP-switch setting. Figure 4-3 tells you how to set an individual DIP switch. Table 4-6. Control Switch Settings. Config1 Switches Control 1 2 3 4 5 6 7 8 Sniffer ON 24

6. Connect the communication ports. The communication ports are on the rear of the unit. Table 4-7 provides the COMM IN port pin configuration. Table 4-8 provides the COMM OUT port pin configuration. Figure 4-4 shows the location of the pins in the RJ-11 connector. 1 2 3 4 5 6 Figure 4-4. RJ-11 Connector. Table 4-7. COMM IN Pins (RJ-11). Pin Description Dir. 1 Not Used 2 Master/Slave IN 3 Signal Ground 4 Receive Data OUT 5 Transmit Data IN 6 Not Used 25

Connect the COMM IN port to the Sniffer Server via the included Control Cable. Table 4-9 describes the cable, indicating the pins that must be connected. Table 4-8. COMM OUT Pins (RJ-11). Pin Description Dir. 1 Not Used 2 Master/Slave OUT 3 Signal Ground 4 Receive Data IN 5 Transmit Data OUT 6 Not Used Table 4-9. Control Cable, Sniffer-to-Unit (included). Sniffer COM 1 DB9 female Unit COMM IN RJ-11 5 - - - - - - - - - - - - - - -3 2 - - - - - - - - - - - - - - -4 3 - - - - - - - - - - - - - - -5 26

Table 4-10. Communication Cable, Unit-to-Unit (included). Unit COMM OUT RJ-11 Unit COMM IN RJ-11 2 - - - - - - - - - - - - - - -2 3 - - - - - - - - - - - - - - -3 4 - - - - - - - - - - - - - - -4 5 - - - - - - - - - - - - - - -5 27

7. Connect the test equipment lines. Connect the test equipment lines to the monitor ports. The monitor ports are on the rear of the unit. 8. Connect networks. Connect the networks to the network ports. The network ports are on the rear of the unit. 9. Connect the power supply. Plug the power cord into both the unit and an AC power source. The power socket is on the rear of the unit. To Sniffer Server Monitor Card To Networks AC Power Source IN OUT IN OUT 1 2 3 4 PORT 5 6 7 8 CONFIG1 CONFIG2 IN COMM OUT To Sniffer Server COM Port Figure 4-5. Rear of the Monitor Access Unit, Showing Connections to Ports. 28

4.3 Installing the Software To install the software, follow these steps: NOTE For detailed information on the following, please see the Distributed Sniffer Server System documentation: How to transfer files to a Sniffer Server. How to configure switch and enable segments on a Sniffer Server. 1. Create the following directory on the Distributed Sniffer Server (DSS): C:\CONFIG\SWITCH\HADAX 2. Copy the following files to the directory that you created in step 1: HDX250.EXE The executable file that the Sniffer Server uses to control the Monitor Access Unit. HDS250.DEF The definition file that describes the various Monitor Access Unit configurations and tells the Sniffer Server how to operate for each configuration (for more information, see Appendix A). PARENT.EXE An executable file that allows advanced users to troubleshoot how the Monitor Access Unit and the executable file operate together. 29

5. Manual Operation This chapter describes how to manually operate the Monitor Access Unit for testing purposes. In particular, it describes the operations that you can perform: Connecting a test device to a network. Disconnecting a test device from a network. NOTE Manual operation is disabled when the Monitor Access Unit is configured for use with Network General s Sniffer Server. 5.1 Connecting Test Devices NOTE If you are using the Monitor Access Switch with Network General s Sniffer Server, you cannot manually connect a test device to a network. To connect a test device to a network, simultaneously press the monitor switch and the network switch. When you connect a test device to a network, the appropriate LED will light up. For example, if you press the switch together with the 4 switch, the test device at is connected to the network at 4 and the appropriate LED lights up (see Figure 5-1). NOTE Before the unit connects the ports, it terminates any connections at the and 4 ports. ON ENABLE DISABLE ENABLE DISABLE MON 1 1 2 3 4 5 6 7 8 MON 2 Figure 5-1. Connecting a Test Device to a Network. 30

5.2 Disconnecting Test Devices MONITOR ACCESS UNIT NOTE If you are using the Monitor Access Switch with Network General s Sniffer Server, you cannot manually disconnect a test device from a network. To disconnect a test device from a network, press the appropriate monitor switch. The LED, indicating connection, will no longer light. For example, if you want to disconnect the test device at, press the monitor switch at (see Figure 5-2). The appropriate LED will no longer light. ON ENABLE DISABLE ENABLE DISABLE MON 1 1 2 3 4 5 6 7 8 MON 2 Figure 5-2. Disconnecting a Test Device from a Network. 31

Appendix A: HDX250.DEF This appendix describes the DEF files necessary for the Monitor Access Unit to work with Network General s Sniffer Server. There is one such file: CAUTION Do not change the settings in this file. If you do, the Sniffer Server and the Monitor Access Unit will not operate correctly. This file specifies the possible Monitor Access Unit configurations and defines the settings for those configurations. It follows the format that is specified by Network General for definition files that are compatible with the Distributed Sniffer Server System (DSS). The file consists of 14 sections, one for each possible configuration. The sections are as follows: [Hadax Monitor Access Unit Ethernet 1x8] [Hadax Monitor Access Unit Token Ring 1x8] [Hadax Monitor Access Unit WAN 1x8] [Hadax Monitor Access Unit Token Ring 1x16] [Hadax Monitor Access Unit WAN 1x16] [Hadax Monitor Access Unit Ethernet 1x16] [Hadax Monitor Access Unit Token Ring 2x8] [Hadax Monitor Access Unit WAN 2x8] [Hadax Monitor Access Unit Ethernet 2x8] [Hadax Monitor Access Unit Token Ring 2x16] [Hadax Monitor Access Unit WAN 2x16] [Hadax Monitor Access Unit Ethernet 2x16] 32

Each of these section names appears on the Sniffer Server user interface. When an operator chooses one of the available configurations, the Sniffer Server uses the settings in that section. Each section consists of the following four lines: Network, which specifies the type of networks and the number of networks that are connected to the Monitor Access Unit. Offline, which indicates whether or not operators can disconnect a Monitor port from a Network port. Commons, which specifies the number of Sniffer Servers that are connected to the Monitor Access Unit. Exe, which specifies the executable file to use when controlling the Monitor Access Unit. 33

Copyright 1999. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746