Wiring Diagrams INDEX

Similar documents
Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR

WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin / March 2013

T7079A,B Solid State Remote Temperature Controllers

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

T6570, T8570 Series Digital Fan-Coil Thermostats

Controls for fan coil units and cassettes

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

INSTALLATION INSTRUCTIONS MC95HAE-1 MASTER CONTROLLER

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Low Profile Unit Cooler

Failure code manual. content

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Thermostatic Wiring Principles by Bob Scaringe Ph.D., P.E.

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Installation Instructions

E2 Series Electric Furnaces

INSTALLATION AND OPERATION MANUAL

MicroTech III Unit Controller for Water Source Heat Pump Units

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

Lesson 36 Selection Of Air Conditioning Systems

PNEUMATIC CONTROLS Selection and Description

FLORIDA STATE COLLEGE AT JACKSONVILLE NON-COLLEGE CREDIT COURSE OUTLINE

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

HERZ-Thermal Actuators

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Why and How we Use Capacity Control

Oil and Coolant Circulating Heating System. Model - OCSM

ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

PNEUMATIC CONTROLS Dual Duct Sequence Descriptions

S & P COIL PRODUCTS LTD SPC HOUSE, EVINGTON VALLEY ROAD, LEICESTER. LE5 5LU. Electrical layouts for EC Motors in Fan Convector units

MicroTech III Unit Controller for Water Source Heat Pump Units

Table of Contents. 1 - Specifications Installation Wiring User controls...7

1 For All Non-Programmable Digital Thermostat

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

CAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

Flush-mounted room thermostats

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Commercial Semi-Instantaneous Water Heaters

Models: Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel. Blower Housing

, User s Manual

HEAT HEAT COOL HEAT PUMP COOL

T6861 Series Large LCD Digital Thermostat 110/220 VAC 2-pipe/4-pipe fan coil control

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

SERVICE MANUAL REFRIGERATION

T841A Heating-Cooling Heat Pump Thermostat

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV Comfortnet Compatible 1½ to 5 Tons. Contents.

Electrical Symbols and Line Diagrams

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

What s the Difference? 2 Pipe vs 4 Pipe Fan Coil

Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL WH483 WH602. Contents. General Notes. Important. Description

TC-9102 Series Surface Mount Temperature Controllers

catalog Single Package Vertical Air Conditioners and Heat Pumps

Models: WA182, WA242. Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel.

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

PLP - TERMS AND CONDITIONS

Installation Instructions

SECTION GENERAL PROVISIONS FOR HVAC WORK

Cool Design for Homes and Offices

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

1F Programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

WHITE-RODGERS COMFORT-SET 90 SERIES

Fundamentals of HVAC Control Systems

T7560A,B,C Digital Wall Module

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

Commercial Gas Furnace Upflow

User Manual THR840DUK Digital Thermostat

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

T-100-R Installation Guide

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features

GENERAL PRODUCT OVERVIEW

Compressors, Chillers & Condensers

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX

Explosion-Proof Electric Unit Heaters

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

features Electric Room Thermostats Description Applications Thermostats & Hygrostats

ENHANCED LABORATORY HVAC SYSTEM

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Transcription:

BH,BV,CA,CE,CF,C,CK,DA,DC,DD, DE,DF,S,SH,SJ,VA,VB,VC,VE,VF,V Fan Coil Air Conditioners Wiring Diagrams INDEX UNIT MODEL (CFM) BH,BV (600 to 000) CA,CE,CF, C, CK,VA,VB,VC, VE,VF,V (00-00) DA,DC,DD, DE,DF (600-000) DA,DC,DD, DE,DF (00-000) TYPE THERMOSTAT DIARAM NUMBER FIURE NUMBER Single-Phase Unit with Motor Control Only 776 Single-Phase Unit with Motor Controls and Interlocking Disconnect 770 Single-Phase Unit with Motor Controls, Interlocking Disconnect, and Electric Heater 770 Single-Phase Unit without Controls 770 -Pipe or -Pipe Cooling Only with Single-Speed Fan Operation and Honeywell Thermostat T8C 000-0000876 5 -Pipe or -Pipe Cooling Only with Single-Speed Fan Operation and Honeywell Digital Thermostat T850D 000-000087 6 -Pipe or -Pipe Heating Only with Single-Speed Fan Operation and Honeywell Thermostat T8C 000-0000875 7 -Pipe or -Pipe Heating Only with Single-Speed Fan Operation and Honeywell Digital Thermostat T850D 000-000087 8 -Pipe or -Pipe Heating/Cooling with Single-Speed Fan Operation and Honeywell Thermostat T8C 000-000087 9 -Pipe or -Pipe Heating/Cooling with Single-Speed Fan Operation and Honeywell Digital Thermostat T850D 000-000089 0 -Phase Unit with Motor Control Only 777 -Phase Unit with Motor Controls and Interlocking Disconnect 770 -Phase Unit without Controls 770 -Pipe with Auxiliary Electric Heat Dual Power Source (-v) CSSN-FC 76080 -Pipe with Auxiliary Electric Heat Master Control Option CSSN-FC 8575750 5 -Pipe with Auxiliary Electric Heat Follower Control Option CSSN-FC 8575750 6 -Pipe with Auxiliary Electric Heat Dual Power Source TB55-06 (7089-6) 770 7 -Pipe Cooling Only (-v) CSSN-FC 76060 8 -Pipe Cooling Only TB55-06 (7089-6) 7770 9 -Pipe Heating Only (-v) CSSN-FC 76050 0 -Pipe Heating Only with Wall-Mounted Thermostat TB55-06 (7089-6) 7780 -Pipe Heating/Cooling with Automatic Changeover (-v) CSSN-FC 76070 -Pipe Heating/Cooling with Automatic Changeover TB55-06 (7089-6) 7750 -Pipe with Total Electric Heat Dual Power Source (-v) CSSN-FC 76090 -Pipe with Total Electric Heat Wall-Mounted Thermostat, Dual Power Source TB55-06 (7089-6) 770 5 -Pipe Heating/Cooling (-v) CSSN-FC 7600 6 -Pipe Heating/Cooling with Wall-Mounted Thermostat TB55-06 (7089-6) 77090 7 No Controls Wall-Mounted -Speed Switch Only 70890 8 -Pipe with Auxiliary Electric Heat Dual Power Source (-v) CSSN-FC 76080 9 -Pipe with Auxiliary Electric Heat Dual Power Source TB55-06 (7089-6) 77 0 -Pipe with Auxiliary Electric Heat and Heating/Cooling Duct Sensor (-v) CSSN-FC 75960 -Pipe Cooling Only (-v) CSSN-FC 76060 -Pipe Cooling Only with Fan Cycle Relay Control TB55-06 (7089-6) 7770 -Pipe Heating Only (-v) CSSN-FC 76050 -Pipe Heating Only with Fan Cycle Relay Control TB55-06 (7089-6) 7780 5 -Pipe Heating/Cooling with Automatic Changeover (-v) CSSN-FC 76070 6 -Pipe Heating/Cooling with Automatic Changeover and Fan Cycle Relay Control TB55-06 (7089-6) 7750 7 -Pipe with Total Electric Heat Dual Power Source (-v) CSSN-FC 76090 8 -Pipe with Total Electric Heat Wall-Mounted Thermostat, Dual Power Source TB55-06 (7089-6) 77 9 -Pipe Cooling with Automatic Changeover (-v) CSSN-FC 75950 0 -Pipe Heating/Cooling (-v) CSSN-FC 7600 -Pipe Heating/Cooling with Wall-Mounted Thermostat TB55-06 (7089-6) 77090 No Controls Wall-Mounted -Speed Switch Only 70890 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book PC 0 Catalog No. 0-56000-0 Printed in U.S.A. Form -W Pg 6-05 Replaces: -W Tab 7a

INDEX (cont) UNIT MODEL (CFM) S,SH,SJ (00-00) VA,VB,VC,VE, VF,V (00-00) TYPE THERMOSTAT DIARAM NUMBER FIURE NUMBER -Pipe with Auxiliary Electric Heat Dual Power Source (-v) CSSN-FC 76080 -Pipe with Auxiliary Electric Heat Single Source (-Aquastat) TB55-06 (7089-6) 77 5 -Pipe with Auxiliary Electric Heat Unit-Mounted Thermostat Heating/Cooling Automatic Changeover with -Speed Switch and Dual Power Source C/C7 709605 6 -Pipe Cooling Only (-v) CSSN-FC 76060 7 -Pipe Cooling Only TB55-06 (7089-6) 7770 8 -Pipe Heating or Cooling Unit Mounted Thermostat with -Speed Switch C/C7 7090 9 -Pipe Heating/Cooling with Automatic Changeover (-v) CSSN-FC 76070 50 -Pipe Heating/Cooling with Automatic Changeover TB55-06 (7089-6) 7750 5 -Pipe Heating/Cooling with Automatic Changeover Unit-Mounted Thermostat with -Speed Switch C/C7 7050 5 -Pipe with Total Electric Heat Dual Power Source C/C7 7090706 5 -Pipe with Total Electric Heat Dual Power Source (-v) CSSN-FC 76090 5 -Pipe with Total Electric Heating Only Wall-Mounted Thermostat Single Power Source with Service Switch TB55-06 (7089-6) 7706 55 -Pipe Heating/Cooling (-v) CSSN-FC 7600 56 -Pipe Heating/Cooling with Unit-Mounted Thermostat with -Speed Switch C/C7 70005 57 -Pipe Heating/Cooling with Wall-Mounted Thermostat TB55-06 (7089-6) 77090 58 -Pipe with Auxiliary Electric Heat Unit-Mounted Thermostat with Heating/Cooling Automatic Changeover with -Speed Switch and Dual Power Source C/C7 70967 59 -Pipe Heating or Cooling with Unit-Mounted Thermostat with -Speed Switch C/C7 7090 60 -Pipe Heating/Cooling with Automatic Changeover (-v CSSP-FC) CSSP-FC 7600 6 -Pipe Heating/Cooling with Automatic Changeover (-v CSSN-FC) CSSN-FC 75950 6 -Pipe Heating/Cooling with Automatic Changeover, Unit-Mounted Thermostat with -Speed Switch C/C7 7050 6 -Pipe with Total Electric Heat with Unit-Mounted Thermostat with -Speed Switch and Dual Power Source C/C7 7090705 6 -Pipe with Auxiliary Electric Heat and Heating/Cooling Duct Sensor (-v) CSSN-FC 75960 65 -Pipe Cooling with Duct Sensor (-v) CSSN-FC 7590 66 -Pipe Heating with Duct Sensor (-v) CSSN-FC 7590 67 -Pipe with Total Electric Heat and Duct Sensor Single Power Source (-v) CSSN-FC 75970 68 -Pipe Heating/Cooling with Duct Sensor Single Power Source (-v CSSN-FC) CSSN-FC 75980 69 -Pipe Heating/Cooling with Duct Sensor Single Power Source (-v CSSP-FC) CSSP-FC 7600 70 -Pipe Heating/Cooling with Unit-Mounted Thermostat With -Speed Switch C/C7 7000 7 AW American Wire age Common CSA Canadian Standards Association CW Cold Water ELEC Electric FLA Full Load Amps ND round HW Hot Water LRA Locked Rotor Amps LEEND (Fig. -7) NC Normally Closed NEC National Electrical Code NO Normally Open Quick Connect RES Resistance SA Supply Air TB Terminal Block TSTAT Thermostat UL Underwriters Laboratories Terminal (Marked) Terminal (Unmarked) Terminal Block Splice Factory Wiring Field Wiring *Use for 0/77 v. Use for 08/0 v. NOTES:. Disconnect power before servicing.. See name plate for correct voltage. Use 75 C minimum copper conductors only. Unit terminals are not designed to accept any other wiring.. Motor(s) are thermally protected. Units with motors are wired parallel.. Provide disconnect means and overcurrent protection as required. 5. Motor shown for 0/77 v operation, for 08/0 v motor common is or. 6. Valve optional, factory-supplied or field-supplied with NEC class wiring. Do not exceed thermostat rating. 7. To ensure proper fan interlock and sequencing, external controller must energize heater stages in numerical order shown and deenergize stages in reverse order (first on, last off). 8. All contractor wiring must conform to national and local electrical codes.

OPERATION Manual Fan Control The standard fan-speed switch is furnished unit-mounted and wired on all vertical cabinet units. On all vertical furred-in units and all horizontal units, the switch is shipped separately on a decorative wall plate for field mounting and wiring. The standard switch has, IUM, H and OFF positions plus an auxiliary contact to energize thermostats, valves, dampers, etc. Thermostatic Fan Control, -Pipe Systems The thermostat cycles the fan on and off from any selected speed setting to maintain selected room temperature. Controls can be wired for heating-only, cooling-only or for heating/ cooling with the addition of an automatic changeover device that senses water temperature and changes the action of the thermostat as required. Thermostatic Fan Control, -Pipe Systems with Safety Cycle This control is used for high humidity situations in which condensate problems can occur if fan is turned off while chilled water is still running through the coil. The wiring provides fan cycling from H to on the cooling cycle and from to OFF on the heating cycle. An ON-OFF toggle switch replaces the standard -speed fan switch. The toggle switch can be concealed to ensure that the unit runs on low speed when cooling. This action greatly reduces the chance of condensation problems that exist with other standard fan cycling controls. Thermostatic Electric Valve Control, -Pipe A thermostatically controlled -position valve provides superior control to fan cycling. With this control, the fan runs continuously unless it is manually switched to the OFF position. The fan must be on before the valve can be opened to supply water to the coil. This system can be used for normal -pipe changeover systems and can also be furnished for cooling-only or heatingonly applications by omitting the changeover and specifying which application is intended. Thermostatic -Pipe Auxiliary Electric Heat with Valve Control This system, also called Twilight or Intermediate Season electric heat, goes a long way towards solving the spring and fall control problems of -pipe systems. Chilled water can be available late into the fall. It may also be turned on early in the spring and still provide heat to all units when required. In winter, the system is switched over to hot water and requires two auto changeover devices (aquastats). One device controls the switching of the thermostat, the other device locks out the electric heater when hot water is in the coil. With this system, the fan runs continuously unless manually switched to the OFF position. Fan must be on before thermostat can send signal to open chilled water valve or turn on electric heater. Two control methods are available:. Use of a standard automatic changeover thermostat with a deadband between heating and cooling.. Use of a manual changeover thermostat. Only one changeover is required with this method. A -way or -way electric valve must be included with this system. Thermostat -Pipe Total Electric Heat with Valve Control With this system, the complete heating requirement for the space is provided by the electric heater; the water system is never changed over for heating. It is therefore possible, just as with -pipe systems, to have heating or cooling at any time of the year. The fan runs continuously unless it is manually switched to the OFF position. Fan must be on before thermostat can send signal to open chilled water valve or turn on electric heater. Normally, an automatic changeover thermostat with a deadband between heating and cooling is used, but a manual changeover thermostat is also suitable. A -way or -way valve must also be used so that the chilled water is off whenever the heater is on. No changeover device to sense water temperature is necessary. Thermostatic Valve Control, -Pipe The -pipe system provides the ultimate in economy and room temperature control. Both hot water and chilled water are available at any time. Normally an automatic changeover thermostat is used, but a manual changeover thermostat is also suitable. Two -way valves, two -way valves, or one -way plus one -way valve must be selected. An automatic changeover device to sense water temperature is not required. With this system, the fan runs continuously unless it is manually switched to the OFF position. The fan must be on before thermostat can send a signal to open the chilled water or hot water valve.

Fig. BHC,BVC (600 to 000 Cfm) Single-Phase Unit with Motor Control Only Fig. BHC,BVC (600 to 000 Cfm) Single-Phase Unit with Motor Controls and Interlocking Disconnect

HEATER CONTACTS FUSE BLOCK DISCONNECT CONTACTOR AIRF SENSOR TERMINAL BOX CONTACTOR NOTES:. Wires 9,, and will terminate inside contactor lug.. Wires, 5 and 6 to be installed as shown in Detail A when using P/N 5000 disconnect switch. All other disconnect switches to be wired as shown in main diagram.. Use applicable heater configuration shown for proper connections. Fig. BHC,BVC (600 to 000 Cfm) Single-Phase Unit with Motor Controls, Interlocking Disconnect, and Electric Heater 5

Fig. BHC,BVC (600 to 000 Cfm) Single-Phase Unit without Controls NOTES:. Optional valves are field wired.. No HW valve with electric heat. Fig. 5 BHC,BVC (600 to 000 Cfm) -Pipe Cooling Only with Single-Speed Fan Operation and Honeywell Thermostat 6

NOTE: Optional valves are field wired. Fig. 6 BHC,BVC (600 to 000 Cfm) -Pipe Cooling Only with Single-Speed Fan Operation and Honeywell Digital Thermostat Fig. 7 BHC,BVC (600 to 000 Cfm) -Pipe Heating Only with Single-Speed Fan Operation and Honeywell Thermostat NOTES:. Optional valves are field wired.. No HW valve with electric heat. 7

Fig. 8 BHC,BVC (600 to 000 Cfm) -Pipe Heating Only with Single-Speed Fan Operation and Honeywell Digital Thermostat NOTES:. Optional valves are field wired.. No HW valve with electric heat. NOTES:. Optional valves are field wired.. No HW valve with electric heat. Fig. 9 BHC,BVC (600 to 000 Cfm) -Pipe or -Pipe Heating/Cooling with Single-Speed Fan Operation and Honeywell Thermostat 8

NOTES:. Optional valves are field wired.. No HW valve with electric heat. Fig. 0 BHC,BVC (600 to 000 Cfm) -Pipe or -Pipe Heating/Cooling with Single-Speed Fan Operation and Honeywell Digital Thermostat Fig. BHC,BVC (600 to 000 Cfm) -Phase Unit with Motor Control Only 9

Fig. BHC,BVC (600 to 000 Cfm) -Phase Unit with Motor Controls and Interlocking Disconnect Fig. BHC,BVC (600 to 000 Cfm) -Phase Unit without Controls 0

REMOTE DEVICE BOX RS+5 RS THERMOSTAT #CSSN-FC R Y W C HO CK NEC CLASS WIRIN CHANE OVER SENSOR COOL /(W) /(Y) ZCRLYBRD () L M H ROUND L / L or N ROUND 0 06 NC 7 LIMIT SWITCH L 8 NO 6 N ELEC. HEATER Fig. C,V (00 to 00 Cfm), D (600 to 000 Cfm) -Pipe with Auxiliary Electric Heat Dual Power Source (-v) Fig. 5 C,V (00 to 00 Cfm), D (600 to 000 Cfm) -Pipe with Auxiliary Electric Heat Master Control Option

Fig. 6 C,V (00 to 00 Cfm), D (600 to 000 Cfm) -Pipe with Auxiliary Electric Heat Follower Control Option THERMOSTAT PART # 7089-6 REMOTE DEVICE BOX COOL HEAT L L OR N W/ W/ W/ UNIT MOUNTED J BOX OPTIONAL L M H AQUASTATS RISE ROUND L or N RISE L LIMIT SWITCH CONTACTOR RN L OR N L ONLY 0V /ALL OTHERS Fig. 7 C,V (00 to 00 Cfm), D (600 to 000 Cfm) -Pipe with Auxiliary Electric Heat Dual Power Source

Fig. 8 C,V (00 to 00 Cfm), D (600 to 000 Cfm) -Pipe Cooling Only (-v) THERMOSTAT PART # 7089-6 REMOTE DEVICE BOX COOL HEAT L L OR N W/ W/ W/ UNIT MOUNTED J BOX NEC CLASS WIRIN OPTIONAL L M H COOL L or N FOR 0V ALL OTHERS L ROUND Fig. 9 C,V (00 to 00 Cfm), D (600 to 000 Cfm) -Pipe Cooling Only

REMOTE DEVICE BOX RS+5 THERMOSTAT #CSSN-FC RS R Y W C HO CK NEC CLASS WIRIN HEAT /(W) /(Y) ZCRLYBRD () L M H ROUND L L or N Fig. 0 C,V (00 to 00 Cfm), D (600 to 000 Cfm) -Pipe Heating Only (-v) ONLY 0V /ALL OTHERS Fig. C,V (00 to 00 Cfm), D (600 to 000 Cfm) -Pipe Heating Only with Wall-Mounted Thermostat

Fig. C,V (00 to 00 Cfm), D (600 to 000 Cfm) -Pipe Heating/Cooling with Automatic Changeover (-v) THERMOSTAT PART # 7089-6 REMOTE DEVICE BOX COOL HEAT L L OR N W/ W/ W/ UNIT MOUNTED J BOX NEC CLASS WIRIN L M H RISE AQUASTAT L or N L ROUND 5 ONLY 0V /ALL OTHERS Fig. C,V (00 to 00 Cfm), D (600 to 000 Cfm) Heating/Cooling with Automatic Changeover

REMOTE DEVICE BOX RS+5 THERMOSTAT #CSSN-FC RS R Y W C HO CK NEC CLASS WIRIN COOL /(W) /(Y) ZCRLYBRD () L M H ROUND L / L or N ROUND 0 06 NC 7 LIMIT SWITCH L 8 NO 6 N ELEC. HEATER Fig. C,V (00 to 00 Cfm), D (600 to 000 Cfm) -Pipe Total Electric Heat (-v) Fig. 5 C,V (00 to 00 Cfm), D (600 to 000 Cfm) -Pipe Total Electric Heat Wall-Mounted Thermostat Dual Power Source 6

REMOTE DEVICE BOX RS+5 THERMOSTAT #CSSN-FC RS R Y W C HO CK NEC CLASS WIRIN COOL HEAT /(W) /(Y) ZCRLYBRD () L M H ROUND L L or N Fig. 6 C,V (00 to 00 Cfm), D (600 to 000 Cfm) -Pipe Heating/Cooling (-v) ONLY 0V /ALL OTHERS Fig. 7 C,V (00 to 00 Cfm), D (600 to 000 Cfm) -Pipe Heating/Cooling with Wall-Mounted Thermostat 7

Fig. 8 C,V (00 to 00 Cfm), D (600 to 000 Cfm) No Controls Wall-Mounted -Speed Switch Only 8

THERMOSTAT #CSSN-FC REMOTE DEVICE BOX R Y W C HO CK RS RS+5 NEC CLASS WIRIN ZCRLYBRD CHANE OVER SENSOR /(W) /(Y) L () M / / 0 6 8 CONTACTOR COOL H VER. 00700 ZCRLYBRD () /(W) /(Y) L M H EQUIP.ROUND LIMIT SWITCH VER. 00700 L N. OR L EQUIP.ROUND L N. OR L ELEC. HEATERS Fig. 9 D (00 to 000 Cfm) -Pipe Auxiliary Electric Heat Dual Power Source (-v) 9

THERMOSTAT PART # 7089-6 REMOTE DEVICE BOX COOL HEAT L L OR N W/ W/ W/ UNIT MOUNTED J BOX AQUASTATS 0 OPTIONAL L RISE M 8 6 H 0 L RISE M 8 6 H LIMIT SWITCH 0 8 6 RELAY L or N L 0 ROUND L CONTACTOR 6 8 L or N ELEC. HEATER ROUND 0V ALL OTHERS Fig. 0 D (00 to 000 Cfm) -Pipe Auxiliary Electric Heat Dual Power Source 0

THERMOSTAT #CSSN-FC R Y W C HO CK RS RS+5 CHANE OVER SENSOR ZCRLYBRD () /(W) /(Y) DUCT SENSOR CSSEN-DS L M H ZCRLYBRD () /(W) /(Y) L M H / / EQUIP.ROUND LIMIT SWITCH L N. OR L 0 6 8 CONTACTOR EQUIP.ROUND L N. OR L ELEC. HEATERS Fig. D (00 to 000 Cfm) -Pipe Auxiliary Electric Heat and Heating/Cooling Duct Sensor (-v)

L M H THERMOSTAT #CSSN-FC R Y W C HO CK RS RS+5 REMOTE DEVICE BOX ZCRLYBRD /(W) /(Y) () M H L NEC CLASS WIRIN ZCRLYBRD () /(W) /(Y) L N. OR L ROUND Fig. D (00 to 000 Cfm) -Pipe Cooling Only (-v)

THERMOSTAT PART # 7089-6 REMOTE DEVICE BOX COOL HEAT L L OR N W/ W/ W/ NEC CLASS I WIRIN VIO COOL 0 B UNIT MOUNTED J BOX L ROUND L or N L M H L M H NC 7 8 NO 6 0 B NC 7 8 NO 6 0V ALL OTHERS 0 B NC 7 8 NO 6 Fig. D (00 to 000 Cfm) -Pipe Cooling Only with Fan Cycle Relay Control

THERMOSTAT #CSSN-FC R Y W C HO CK RS RS+5 REMOTE DEVICE BOX ZCRLYBRD /(W) /(Y) () M H L NEC CLASS WIRIN L M H ZCRLYBRD () /(W) /(Y) QC / / L N. OR L ROUND Fig. D (00 to 000 Cfm) -Pipe Heating Only (-v)

THERMOSTAT PART # 7089-6 REMOTE DEVICE BOX COOL HEAT L L OR N W/ W/ W/ UNIT MOUNTED J BOX ONLY 0V /ALL OTHERS 0 OPTIONAL HEAT L M 6 8 H 0 L 6 8 M 0 H 6 8 RELAY L or N L ROUND Fig. 5 D (00 to 000 Cfm) -Pipe Heating Only with Fan Cycle Relay Control 5

Fig. 6 D (00 to 000 Cfm) -Pipe Heating/Cooling with Automatic Changeover (v) 6

THERMOSTAT PART # 7089-6 REMOTE DEVICE BOX COOL HEAT L L OR N W/ W/ W/ UNIT MOUNTED J BOX ONLY 0V /ALL OTHERS 0 NC 7 8 NO 6 L M H 0 NC 7 8 NO 6 L M RISE H 0 8 NC 7 NO 6 AQUASTAT ROUND L or N L Fig. 7 D (00 to 000 Cfm) -Pipe Heating/Cooling with Automatic Changeover and Fan Cycle Relay Control 7

THERMOSTAT #CSSN-FC REMOTE DEVICE BOX R Y W C HO CK RS RS+5 NEC CLASS WIRIN COOL L M H L M H LIMIT SWITCH ZCRLYBRD () /(W) /(Y) ELEC. HEATERS VER. 00700 0 ZCRLYBRD 7 8 () /(W) /(Y) / EQUIP.ROUND VER. 00700 L N. OR L 06 EQUIP.ROUND NC NO 6 L N. OR L Fig. 8 D (00 to 000 Cfm) -Pipe Total Electric Heat Dual Power Source (-v) 8

ONLY 0V /ALL OTHERS Fig. 9 D (00 to 000 Cfm) -Pipe Total Electric Heating Only Wall-Mounted Thermostat, Dual Power Source 9

ZCRLYBRD () /(W) /(Y) CHANE OVER SENSOR THERMOSTAT #CSSN-FC ZCRLYBRD QC () /(W) /(Y) L M H / / L M H DUCT SENSOR CSSEN-DS EQUIP.ROUND L N. OR L R Y W C HO CK RS RS+5 Fig. 0 D (00 to 000 Cfm) -Pipe Cooling with Automatic Changeover (-v) 0

THERMOSTAT #CSSN-FC R Y W C HO CK RS RS+5 REMOTE DEVICE BOX M H ZCRLYBRD L L NEC CLASS WIRIN M H HEAT COOL () /(W) /(Y) ZCRLYBRD () /(W) /(Y) / L N. OR L ROUND Fig. D (00 to 000 Cfm) -Pipe Heating/Cooling (-v)

Fig. D (00 to 000 Cfm) -Pipe Heating/Cooling with Wall-Mounted Thermostat Fig. D (00 to 000 Cfm) No Controls Wall-Mounted -Speed Switch Only

REMOTE DEVICE BOX RS+5 RS THERMOSTAT #CSSN-FC R Y W C HO CK NEC CLASS WIRIN CHANE OVER SENSOR COOL /(W) /(Y) ZCRLYBRD () L M H ROUND L / L or N ROUND 0 06 NC 7 LIMIT SWITCH L 8 NO 6 N ELEC. HEATER Fig. S (00 to 00 Cfm) -Pipe with Auxiliary Electric Heat Dual Power Source (-v)

THERMOSTAT PART # 7089-6 REMOTE DEVICE BOX COOL HEAT L L OR N W/ W/ W/ UNIT MOUNTED CONTROL BOX 6 5 8 9 QUICK CONNECT ELEC. HEATER LIMIT SWITCH 5 L M H CAPACITOR USED ON 08/0V ONLY CONTACTOR FUSE AQUASTATS RISE RISE 0 6 8 RN L L OR N Fig. 5 S (00 to 00 Cfm) -Pipe Auxiliary Electric Heat Single Source (-Aquastat) Fig. 6 S (00 to 00 Cfm) -Pipe Auxiliary Electric Heat Unit-Mounted Thermostat Heating/Cooling Automatic Changeover with -Speed Switch and Dual Power Source

Fig. 7 S (00 to 00 Cfm) -Pipe Cooling Only (-v) THERMOSTAT PART # 7089-6 COOL HEAT L L OR N W/ W/ W/ L or N L ROUND PART# 7650 USE HARNESS (OPTIONAL) QUICK CONNECT 5 L M H CAPACITOR 6 5 7 8 9 UNIT MOUNTED J BOX COOL Fig. 8 S (00 to 00 Cfm) -Pipe Cooling Only 5

Fig. 9 S (00 to 00 Cfm) -Pipe Heating or Cooling Unit-Mounted Thermostat with -Speed Switch Fig. 50 S (00 to 00 Cfm) -Pipe Heating/Cooling with Automatic Changeover (-v) 6

THERMOSTAT PART # 7089-6 REMOTE DEVICE BOX COOL HEAT L L OR N W/ W/ W/ UNIT MOUNTED J BOX QUICK CONNECT L or N L 5 L M H CAPACITOR RISE AQUASTAT ROUND USE OR Fig. 5 S (00 to 00 Cfm) -Pipe Heating/Cooling with Automatic Changeover Fig. 5 S (00 to 00 Cfm) -Pipe Heating/Cooling with Automatic Changeover Unit-Mounted Thermostat with -Speed Switch 7

Fig. 5 S (00 to 00 Cfm) -Pipe with Total Electric Heat Dual Power Source REMOTE DEVICE BOX RS+5 THERMOSTAT #CSSN-FC RS R Y W C HO CK NEC CLASS WIRIN COOL /(W) /(Y) ZCRLYBRD () L M H ROUND L / L or N ROUND 0 06 NC 7 LIMIT SWITCH L 8 NO 6 N 8 ELEC. HEATER Fig. 5 S (00 to 00 Cfm) -Pipe with Total Electric Heat Dual Power Source (-v)

Fig. 55 S (00 to 00 Cfm) -Pipe with Total Electric Heating Only Wall-Mounted Thermostat, Single Power Source with Service Switch REMOTE DEVICE BOX RS+5 THERMOSTAT #CSSN-FC RS R Y W C HO CK NEC CLASS WIRIN COOL HEAT /(W) /(Y) ZCRLYBRD () L M H ROUND L L or N Fig. 56 S (00 to 00 Cfm) -Pipe Heating/Cooling (-v) 9

Fig. 57 S (00 to 00 Cfm) -Pipe Heating/Cooling Unit-Mounted Thermostat with -Speed Switch Fig. 58 S (00 to 00 Cfm) -Pipe Heating/Cooling Wall-Mounted Thermostat 0

Fig. 59 V (00 to 00 Cfm) -Pipe with Auxiliary Electric Heat Unit-Mounted Thermostat with Heating/Cooling Automatic Changeover, -Speed Switch and Dual Power Source Fig. 60 V (00 to 00 Cfm) -Pipe Heating or Cooling with Unit-Mounted Thermostat and -Speed Switch

THERMOSTAT #CSSP-FC RS+5 RS R Y W C HO CK DUCT SENSOR CSSEN-DS CHANE OVER SENSOR /(W) /(Y) ZCRLYBRD () L M H ROUND L L or N / Fig. 6 V (00 to 00 Cfm) -Pipe Heating/Cooling with Automatic Changeover (-v CSSP-FC) THERMOSTAT #CSSN-FC RS+5 RS R Y W C HO CK SA DUCT SENSOR CHANE OVER SENSOR /(W) /(Y) ZCRLYBRD () L M H ROUND L L or N Fig. 6 V (00 to 00 Cfm) -Pipe Heating/Cooling with Automatic Changeover (-v CSSN-FC)

Fig. 6 V (00 to 00 Cfm) -Pipe Heating/Cooling with Automatic Changeover, Unit-Mounted Thermostat with -Speed Switch Fig. 6 V (00 to 00 Cfm) -Pipe Total Electric Heat with Unit-Mounted Thermostat with -Speed Switch and Dual Power Source

THERMOSTAT #CSSN-FC RS+5 RS R Y W C HO CK DUCT SENSOR CSSEN-DS CHANE OVER SENSOR /(W) /(Y) () L M H ROUND / L L or N 0 06 L NC 7 8 LIMIT SWITCH NO 6 N CONTACTOR ROUND ELEC. HEATER Fig. 65 V (00 to 00 Cfm) -Pipe Auxiliary Electric Heat and Heating/Cooling Duct Sensor (-v) THERMOSTAT #CSSN-FC RS+5 RS R Y W C HO CK DUCT SENSOR CSSEN-DS /(W) /(Y) ZCRLYBRD () L M H ROUND L / L or N Fig. 66 V (00 to 00 Cfm) -Pipe Cooling with Duct Sensor (-v)

THERMOSTAT #CSSN-FC RS+5 RS R Y W C HO CK DUCT SENSOR CSSEN-DS /(W) /(Y) ZCRLYBRD () L M H ROUND L L or N Fig. 67 V (00 to 00 Cfm) -Pipe Heating with Duct Sensor (-v) THERMOSTAT #CSSN-FC RS+5 RS R Y W C HO CK DUCT SENSOR CSSEN-DS /(W) /(Y) ZCRLYBRD () L M H ROUND / L L or N 0 06 L NC 7 8 LIMIT SWITCH NO 6 0/77V N ROUND ELEC. HEATER Fig. 68 V (00 to 00 Cfm) -Pipe with Total Electric Heat and Duct Sensor Single Power Source (-v) 5

THERMOSTAT #CSSN-FC RS+5 RS R Y W C HO CK DUCT SENSOR CSSEN-DS COOL HEAT /(W) /(Y) ZCRLYBRD () L M H ROUND L / L or N Fig. 69 V (00 to 00 Cfm) -Pipe Heating/Cooling with Duct Sensor Single Power Source (-v CSSN-FC) 6

THERMOSTAT #CSSP-FC RS+5 RS R Y W C HO CK DUCT SENSOR CSSEN-DS COOL HEAT /(W) /(Y) ZCRLYBRD () L M H ROUND L L or N Fig. 70 V (00 to 00 Cfm) -Pipe Heating/Cooling with Duct Sensor Single Power Source (-v CSSP-FC) 7

FOR 0V, FOR ALL OTHERS Fig. 7 V (00 to 00 Cfm) -Pipe Heating/Cooling with Unit-Mounted Thermostat and -Speed Switch Copyright 005 Carrier Corporation Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book PC 0 Catalog No. 0-56000-0 Printed in U.S.A. Form -W Pg 8 6-05 Replaces: -W Tab 7a