Reversing Contactors Open Type Version

Similar documents
AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Manual Motor Starter MS 116 up to 16 A Technical Data

Technical catalogue. Modular DIN rail components Installation contactors

Electronic overload relay EF19 and EF45

PSR The compact range Description

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Pluggable interface relays CR-P Pcb relays

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

Catalog. Modular DIN rail components Installation contactors

Plug and Socket Devices CES 63 A Series 8579

Electronic overload relay EF65, EF96 and EF146

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

49 Series - Relay interface modules A. Features

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

80 Series - Modular timers 16 A. Features

MasterINTERFACE 39 Series - Relay interface modules

Series 8146/5-V37 and Series 8150/5-V37

RY2 miniature industrial relays

80 Series - Modular timers 16 A. Features

RM4TG20 three-phase network control relay RM4-T - range V

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Type: DILM32 10(24V50HZ) Article No.:

How can a charging station for electric vehicles be set up simply and safely?

MasterINTERFACE 39 Series - Relay interface modules

Remote Monitoring and REC 501 Control Unit Product Guide

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Actuator-Sensor-Interface

48 SERIES Relay interface modules 10 A

D-Line Contactors, Overload Relays and Accessories

HERZ-Thermal Actuators

Plug and Socket Devices SolConeX 16 A Series 8570

Type: DILM50(230V50HZ,240V60HZ) Article No.:

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Three-phase monitoring relay CM-PFE

R.C.C.B. s two-pole LEXIC

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

THERMAL RELAYS, MOTORSTARTERS

38 Series - Relay interface modules A

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

Bimetallic Overload Relay Specifications

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

ECOCIAT. Domestic hot water heat recovery unit

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Circuit Breakers. NRC Series. NRC Series

Type: DILM9 10(24VDC) Article No.:

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

38 Series - Relay interface modules A

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Relés e Contatores de Estado Sólido SIRIUS

Manual motor starter MS116

Vario-Series Accessories

12 Series - Time switches 16 A. Features

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Safety technique. Emergency stop module BO 5988 safemaster

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

5SV Residual Current Protective Devices

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Digital input modules

Low Voltage Products. Switches Automatic Transfer Switches

13 SERIES. Electronic step relays A

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Tmax MCCBs. Molded case circuit breakers. Tmax

Linear Luminaire with LED Series EXLUX 6402/2

Circuit Breakers. Next Generation of Protection Capabilities

Switching Devices Contactors and Contactor Assemblies Special Applications

Pressure switch MDR 3

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

CONFIGURABLE SAFETY RELAYS

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Panorama. Motor protection and control Manual motor starters, contactors and overload relays

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

SENTRON Switching and Protection Devices Air Circuit Breakers

Transcription:

BEM... A9...A40 VE5.1 BEM... A9...A40 E1112D1 VOA..-0M version >> VOA..-0M, VNA..-0M Reversing contactors... page /1 >> Reversing contactors in kit form... page /6 /0 ABB Control

VOA..-0M, VNA..-0M A1 A2 L1 L2 L 1 5 1 5 2 4 6 2 4 6 A1 A2 Application Reversing contactors for -phase asynchronous motors: for a maximum operating voltage of 690 V, 50 or 60 Hz, for a switching frequency < 600 operations/hour, at ambient temperature < 55 C, in conformity with the IEC 947-4-1 standard. M E0871D1 Description, factory-assembled reversing contactors The reversing contactors are delivered open, wired with their power connections. The control circuit is to be wired by the customer. Protection IP20 for the connecting terminals. The VOA..-0M reversing contactors are provided for fixing on a plate, or rail 5 x 7.5 mm or 5 x 15 mm according to EN 502, and comprises: 2 side-by-side mounted A 9-0-... A 40-0- -pole contactors with the same rating, whose N.C. auxiliary contact is intended for electrical interlocking. 1 VM 5-1 mechanical interlocking device, mechanically preventing one of the contactors from closing as long as the other is closed. 1 BEM -0 power connection set connecting the main poles of the contactors. (Technical data according to the table below). VOA 9-0M SB7808S Type Insulated copper Cross- For reversing contactors connections section BEM 16-0 rigid solid 2.5 mm 2 VOA 9-0M, VOA 12-0M, VOA 16-0M BEM 26-0 rigid stranded 6 mm 2 VOA 26-0M BEM 40-0 rigid stranded 10 mm 2 VOA 0-0M, VOA40-0M VOA 26-0M SB7807S The VNA..-0M reversing contactors are supplied on a mounting plate, and comprises: 2 side-by-side mounted A 95-0-00 or A 110-0-00 -pole contactors with the same rating. 1 VE 5-2 mechanical and electrical interlocking device. This device mechanically prevents one of the contactors from closing while the other contactor is closed. It is also equipped with 2 N.C. auxiliary contacts inserted in the control circuit for electrical interlocking of the contactors. 1 BEM 110-0 power connection set connecting the main poles of the contactors. Insulated copper bars, cross-section 6 mm 2. The hold-in function, if necessary, will be carried out with the help of CA 5-10 type N.O. auxiliary contacts (1 on each contactor) to be supplied separately (see page /2). VNA95-0 VNA 95-0M ABB Control /1

VOA..-0M, VNA..-0M Ordering details Rated Power AC- Type Order code Weight operat. 4-pole motor - 50/60 Hz in current 80 V kg AC- 400 V 415 V 690 V 400 V State control to be completed with Packing A kw kw kw voltage control voltage code 1 piece 9 4 4 5.5 VOA 9-0M 1SBK 1 600R8 00 0.940 12 5.5 5.5 7.5 VOA 12-0M 1SBK 161 600R8 00 0.940 17 7.5 9 9 VOA 16-0M 1SBK 181 600R8 00 0.940 26 11 11 15 VOA 26-0M 1SBK 241 600R8 00 1.470 2 15 15 18.5 VOA 0-0M 1SBK 281 600R8 00 1.710 7 18.5 18.5 22 VOA 40-0M 1SBK 21 600R8 00 1.720 96 45 55 55 VNA 95-0M 1SFK 41 7R8 00 6.800 110 55 59 75 VNA 110-0M 1SFK 451 7R8 00 6.800 Control voltage code Voltage Code V 50 Hz V 60 Hz 8 24 24 1 42 42 2 48 48 110 110... 120 4 110... 115 115... 120 9 220... 20 20... 240 0 20... 240 240 8 80... 400 400... 415 5 400... 415 415... 440 6 415... 440 440 7 Ordering details, contactors accessories SB775S1 CAL 5-11 CA 5-10 SB757S4 SB760S1 SB7575S Description Type Order code Pack- Weight ing in kg Function markers (50 pieces) BA5-50 1 SBN 11 0000 R1000 box 0.7 "N.O." auxiliary contact block CA5-10 1 SBN 00 R10 10 0.0 "N.C." auxiliary contact block CA5-1 SBN 00 R10 10 0.0 "N.O."+"N.C." side-mted cont. blk CAL5-11 1 SBN 00 R11 2 0.050 Control lead terminals (A 95, A 110) Right/left connection LK 110 1 SFN 07 452 R1000 2 0.0 Add. terminal block (A 95 / A 110) LD 110 1 SFN 07 408 R1000 1 0.150 Terminal enlargement pieces LW110 1 SFN 07 407 R1000 1 0.100 (set of bars) for A 95 / A 110 BA 5-50 LK 110 LW110 LW 110 SB8072S LD 110 >> Reversing contactors in kit form... page /6 >> Dimensions... page /4 >> Wiring diagrams... page / /2 ABB Control

VOA..-0M, VNA..-0M Wiring diagrams VOA 9-0M VOA 40-0M reversing contactors, factory assembled With VM 5-1 mechanical interlocking, electrical interlocking by built-in auxiliary contacts. : 5/L O A1 A2 5/ L 6/ T 21 22 A1 A2 6/ T 5/ L 22 21 I I I E0872D 21 21 22 22 N : /L2 E0874D Power circuit Remote control For the hold-in contacts (-) of the and contactors, supply separately 2 x CA 5-10 type N.O. auxiliary contact (see page /2). VNA 95-0M VNA 110-0M reversing contactors, factory assembled With VE 5-2 mechanical and electrical interlocking. : 5/L O 5/ L 6/ T A1 A2 6/ T 5/ L I I E16D I N : /L2 E16D Power circuit Remote control For the hold-in contacts (-) of the and contactors, supply separately 2 x CA 5-10 type N.O. auxiliary contact (see page /2). ABB Control /

VOA..-0M, VNA..-0M Dimensions (in mm) 10 5.5 74 E0876D 12 9 9.5 E0878D 12 9 108. 5 mm EN 502 49 61 5 mm EN 502 48 58 5 mm EN 502 4 5 4 10 E0877D VOA 9-0M VOA 16-0M 4 10 E0879D VOA 26-0M E0880D 4 10 E0881D VOA 0-0M, VOA 40-0M /4 ABB Control

VOA..-0M, VNA..-0M Dimensions (in mm) 210 180 162 E162D 16 175 E1624D 5.8 VNA 95-0M, VNA 110-0M ABB Control /5

in Kit Form Components for reversing contactors in kit form BEM... A9...A40, A95, A110 VE5 BEM... A9...A40, A95, A110 E0884D1 Description Each reversing contactor will include: 2 side-by-side mounted -pole contactors. 1 mechanical and electrical interlocking device. This device mechanically prevents one of the contactors from closing as long as the other contactor is closed. Moreover, it is fitted with 2 N.C. auxiliary contacts that should be wired in the control circuit in order to electrically interlock the contactors. 1 BEM..-0 power connection set connecting the main poles of the contactors (technical data according to the table below). Type Insulated copper Cross- Mounting on contactors connections section BEM 16-0 rigid solid 2.5 mm 2 A 9-0-10, A 12-0-10, A 16-0-10 BEM 26-0 rigid stranded 6 mm 2 A 26-0-10 BEM 40-0 rigid stranded 10 mm 2 A 0-0-10, A 40-0-10 BEM 110-0 bars 6 mm 2 A 95-0-00, A 110-0-00 The connecting terminals have an IP20 degree of protection. Fixing by means of a mounting plate or rail 5 x 7.5 mm or 5 x 15 mm according to EN 502. Coil voltage codes The coil voltage codes are to be used to complete the contactor order codes, page /7. Coil voltage code V 50Hz V 60Hz Code 8 24 24 1 42 42 2 48 48 110 110-120 4 110-115 115-127 9 220-20 20-240 0 20-240 240-260 8 80-400 400-415 5 400-415 415-440 6 415-440 440-460 7 /6 ABB Control

in Kit Form Ordering details Rated Power AC- Contactors Interlocking Connection set operational -phase motor + current 1500 rpm 50 Hz Type Type Type I e AC- state coil voltage: Order code Order code Order code to be completed with Rated coil voltage code: 8 A voltage (V) kw (see page /6) 9 80-400 4 2 x A 9-0-10 9 415 4 1SBL 10 R8 10 7 690 5.5 12 80-400 5.5 2 x A 12-0-10 BEM 16-0 12 415 5.5 1SBL 16 10 R8 10 1SBN 08 R1000 9 690 7.5 17 80-400 7.5 2 x A 16-0-10 17 415 9 1SBL 18 10 R8 10 10 690 9 VE 5-1 26 80-400 11 2 x A 26-0-10 1SBN 0 10 R1000 BEM 26-0 26 415 11 1SBL 24 10 R8 10 1SBN 08 24 R1000 17 690 15 2 80-400 15 2 x A 0-0-10 2 415 15 1SBL 28 10 R8 10 BEM 40-0 21 690 18.5 1SBN 08 28 R1000 7 80-400 18.5 2 x A 40-0-10 7 415 18.5 1SBL 2 10 R8 10 25 690 22 96 80-400 45 2 x A 95-0-00 96 415 55 1SFL 4 10 R8 00 VE 5-2 BEM 110-0 65 690 55 1SBN 0 10 R1000 1SFN 08 4 R1000 110 80-400 55 2 x A 110-0-00 110 415 59 1SFL 45 10 R8 00 82 690 75 Wiring diagrams - Reversing contactors with VE 5-1 interlocking (A 9... A 40) : 5/L O 5/ L 6/ T 6/ T 5/ L E087D A1 A2 I I I N : /L2 E0875D Power circuit Remote control N.O. auxiliary contacts (-) built into the and contactors are available for the hold-in function of the, contactors. For the reversing contactors with VE 5-2 interlocking (A 95 and A 110) use a VNA..-0M wiring diagrams, page / >> Factory assembled reversing contactors... page /1 >> Accessories... page /2 >> Dimensions... page /4 ABB Control /7