Pressure Enthalpy Explained

Similar documents
UNIT 2 REFRIGERATION CYCLE

COURSE TITLE : REFRIGERATION AND AIR CONDITIONING COURSE CODE : 4029 COURSECATEGORY : A PERIODS/WEEK : 5 PERIODS/SEMESTER : 90 CREDITS : 4 OBJECTIVES

Chapter 2 P-H Diagram Refrigeration Cycle Analysis & Refrigerant Flow Diagram

Refrigeration Basics 101. By: Eric Nelson

Characteristics of Evaporators

REFRIGERATION (& HEAT PUMPS)

APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Chapter 3.4: HVAC & Refrigeration System

How To Calculate The Performance Of A Refrigerator And Heat Pump

AIR CONDITIONING TECHNOLOGY

How does solar air conditioning work?

Troubleshooting an Air Conditioning system. R D Holder Eng. Roger D Holder MSME

UNDERSTANDING REFRIGERANT TABLES

COMMERCIAL HVAC EQUIPMENT. Condensers and Cooling Towers

How To Understand Evaporator

How To Design A Refrigeration System

DET: Mechanical Engineering Thermofluids (Higher)

FUNDAMENTALS OF ENGINEERING THERMODYNAMICS

AIR CONDITION & REFRIGERATION INSTALLATION & REPAIR

How Ground/Water Source Heat Pumps Work

Testing methods applicable to refrigeration components and systems

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine

Energy savings in commercial refrigeration. Low pressure control

Sheet 5:Chapter 5 5 1C Name four physical quantities that are conserved and two quantities that are not conserved during a process.

Lesson. 11 Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications. Version 1 ME, IIT Kharagpur 1

Heat Recovery In Retail Refrigeration

Boiler Calculations. Helsinki University of Technology Department of Mechanical Engineering. Sebastian Teir, Antto Kulla

ENGINEERING INFORMATION Hot water and steam service

The Second Law of Thermodynamics

THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A

Air Water Vapor Mixtures: Psychrometrics. Leon R. Glicksman c 1996, 2010

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R404A, R407C AND R410A

Intelligent control system with integrated electronic expansion valves in an air-conditioning system operating at a Telecom telephone exchange

A basic introduction to steam

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

Glossary of Heating, Ventilation and Air Conditioning Terms

PG Student (Heat Power Engg.), Mechanical Engineering Department Jabalpur Engineering College, India. Jabalpur Engineering College, India.

Increasing the evaporation temperature with the help of an internal heat exchanger

RS-52 (R428A) RS-52: PHYSICAL PROPERTIES RS-52 R502 Molecular weight Temperature glide o C Boiling point (1 atm)

High Pressure Ammonia Systems New Opportunities

Rusty Walker, Corporate Trainer Hill PHOENIX

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Condensers & Evaporator Chapter 5

How to choose a heat pump and use it wisely

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Lesson 36 Selection Of Air Conditioning Systems

Purpose of Refrigeration

GEOTHERMAL POWER PLANT CYCLES AND MAIN COMPONENTS

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

Refrigeration Manual. Part 3 - The Refrigeration Load

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

Desuperheater Online Program Sizing Guidance

Guide to Good Commercial Refrigeration Practice. Part 2. System Design and Component Selection

HVAC Systems: Overview

imagine SOLAR AIR CONDITIONING MADE EASY

GUIDE TO AIR SOURCE HEAT PUMPS. Consumer, Specifier, Installer and Merchant guide to Air to water heat pump technology

Analysis of Ammonia Water (NH3-H2O) Vapor Absorption Refrigeration System based on First Law of Thermodynamics

Basics of Steam Generation

Open Cycle Refrigeration System

THE PSYCHROMETRIC CHART AND ITS USE

Chapter 18 Temperature, Heat, and the First Law of Thermodynamics. Problems: 8, 11, 13, 17, 21, 27, 29, 37, 39, 41, 47, 51, 57

Yijun Gao, Wei Wu, Zongwei Han, Xianting Li *

Thermodynamics - Example Problems Problems and Solutions

How To Save Energy With High Pressure Control

3/29/2012 INTRODUCTION HVAC BASICS

FXA Candidates should be able to : Define and apply the concept of specific heat capacity. Select and apply the equation : E = mcδθ

Energy Efficiency Best Practice Guide Industrial Refrigeration

EVALUATION OF UNDERGROUND RAILWAY NETWORKS OPERATING SUSTAINABLE COOLING SYSTEMS. J.A. Thompson*, G.G. Maidment, J.F. Missenden and F.

Air Conditioning Contractors of America

Refrigeration and Air Conditioning with Psychrometry

Name: Class: Date: 10. Some substances, when exposed to visible light, absorb more energy as heat than other substances absorb.

Design of Cold Storage Structure For Thousand Tonne Potatoes

National Grid Small Business Energy Efficiency Program Overview. Central New York Energy Expo March 30, 2010

GEOTHERMAL HEATING AND COOLING INTRODUCTION

How To Use A Water Source Heat Pump

ALONE. small scale solar cooling device Project No TREN FP7EN Project No TREN/FP7EN/ ALONE. small scale solar cooling device

Efficiency of Hydrogen Liquefaction Plants

2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units

MAKING MODERN LIVING POSSIBLE. Refrigeration - an introduction to the basics REFRIGERATION & AIR CONDITIONING DIVISION. Lecture

SIMULATION OF THERMODYNAMIC ANALYSIS OF CASCADE REFRIGERATION SYSTEM WITH ALTERNATIVE REFRIGERANTS

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

CHAPTER 14 THE CLAUSIUS-CLAPEYRON EQUATION

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

GOOD PRACTICE GUIDE 280. Energy efficient refrigeration technology the fundamentals ARCHIVED DOCUMENT BEST PRACTICE PROGRAMME

جامعة البلقاء التطبيقية

Refrigeration & HVAC

P. A. Hilton Ltd REFRIGERATION & AIR CONDITIONING VAPOUR COMPRESSION HEAT PUMPS VENTILATION VOCATIONAL

HEAT RECOVERY FROM CHILLED WATER SYSTEMS. Applications for Heat Reclaim Chillers

Optimal operation of an Ammonia refrigeration cycle

State of the Art Energy Efficient Data Centre Air Conditioning

UNIT 6a TEST REVIEW. 1. A weather instrument is shown below.

Managing Heat Stress in Poultry

CHAPTER 7 THE SECOND LAW OF THERMODYNAMICS. Blank

Optimization of Water - Cooled Chiller Cooling Tower Combinations

Transcription:

Pressure Enthalpy Explained Within the new F Gas course the requirement for an understanding of Pressure Enthalpy (Ph) graphs is proving to be a large learning curve for those who have not come across them before. Many experienced Air Conditioning and Refrigeration Fitters, Technicians and Engineers have either never used them or have been taught at college but now are slightly rusty. In this News Feed we hope that those who have never experienced or are just brushing up Pressure Enthalpy graphs will be able to gain the underpinning knowledge that the course requires. Introduction

A Pressure Enthalpy graph is individual for each refrigerant. They allow the user to quickly identify the state, temperature, pressure, enthalpy, specific volume and entropy of a refrigerant at a given point. Enthalpy is another word for Heat Energy and is usually measured in kilojoules per kilogram. Enthalpy is commonly found on the y axis of the Ph graph. Pressure is measured generally in MPa, KPa or Bar (Absolute); it is most commonly found on the x axis of the Ph graph. Temperature is measured in C/K. and can be found as lines of constant temperature on the Ph graph. The state of the refrigerant can be either liquid or vapour. As the refrigerant changes between the two states it changes from a saturated liquid to a saturated vapour. To the left of the saturated liquid line the refrigerant is liquid. To the right of the saturated vapour line the refrigerant is a vapour. Between the saturated liquid and saturated vapour lines the refrigerant is in a saturated liquid/vapour mix, the percentage of which is can be known by the quality lines which curve down from the critical point (where the saturated vapour and liquid lines converge). Specific Volume is the amount of space (cubic metres) that one kilogram of refrigerant takes up. Entropy is loosely described as the amount of order, disorder (chaos) in a thermodynamic system. The pressure enthalpy chart describes the entropy of the refrigerant which is the amount of enthalpy able to be transferred per Kelvin (K). FIG 1

Figure 1 provides a clear visual understanding of the behaviour of water at a pressure of 1.01325 bar absolute when heat energy is added or removed. It is important to remember the key values for water shown in Figure 1 as these can be used in many calculations for air conditioning and refrigeration design and commissioning work. Steam Tables Changes in the pressure above any liquid or vapour affect the temperatures at which a change of state occurs and the amount of heat energy involved. Steam Tables list these different values over a wide range of pressures. Table 1 lists the values for water at a few selected pressures. TABLE 1 Pressure Saturation Specific Heat Energy Content Temperature Volume Sens Latent Total (bar) ( C) (m 3 /kg) (kj/kg) (kj/kg) (kj/kg) 0.006112 0.01 206.1 0.0 2500.8 2500.8 0.006566 1.0 192.6 4.2 2498.3 2502.5 0.01227 10.0 106.4 42.0 2477.2 2519.2 0.02337 20.0 57.84 83.9 2453.7 2537.6 0.04242 30.0 32.93 125.7 2430.0 2555.7 0.07375 40.0 19.55 167.5 2406.2 2573.7 0.1233 50.0 12.04 209.3 2382.1 2591.4 0.1992 60.0 7.678 251.1 2357.9 2609.0 0.3116 70.0 5.045 293.0 2333.3 2626.3 0.4736 80.0 3.408 334.9 2308.3 2643.2 0.7011 90.0 2.361 376.9 2282.8 2659.7 1.01325 100.0 1.673 419.1 2256.7 2675.8 5.0 151.8 0.375 639.0 2562.0 3201.0 10.0 179.9 0.194 762.0 2584.0 3346.0 20.0 212.4 0.099 907.0 2600.0 3507.0 30.0 233.8 0.066 1004.0 2603.0 3607.0

Note the substantial changes that occur in specific volume and the rate of change of pressure in relation to saturation temperature. Observe the substantial amount of latent heat energy transfer involved in the change of state from Saturated Liquid to Saturated Vapour (or from Saturated vapour to Saturated Liquid) and how this changes considerably with pressure. This is far greater than the small amount of sensible heat energy associated with a change in temperature alone. Clearly, a cooling system for air conditioning or refrigeration using a circulating fluid would be most effective if the latent heat energy transfer can be harnessed through a change of state. The Vapour Compression Cycle and Absorption Cycle use this characteristic very effectively. The Double Effect Absorption Cycle actually uses water as the Refrigerant. The Single Effect Absorption Cycle uses ammonia as the Refrigerant. A Refrigerant can be defined as a reticulating fluid transferring heat energy from one part of the system to another. The Vapour Compression Cycle uses a wide range of Refrigerants according to application requirements including operating temperatures, pressures, ambient temperatures and efficiency. Compare the characteristics of Refrigerant R22 (Chlorodifluoromethane) in Table 2 with those of water in Table 1. TABLE 2 Pressure Saturation Liquid Vapour Heat Energy Content Temperature Volume Volume Liquid Latent Vapour (bar) ( C) m 3 /Mg m 3 /kg (kj/kg) (kj/kg) (kj/kg) 1.05161 40.0 0.70924 0.20587 55.98 232.61 288.59 1.63466 30.0 0.72420 0.136244 66.62 226.67 293.30 2.44438 20.0 0.75046 0.093268 77.50 220.30 297.80 3.53431 10.0 0.75822 0.065692 88.62 213.43 302.05 4.96256 0.0 0.77778 0.047389 100.00 205.99 305.99 5.82289 5.0 0.78834 0.040561 105.79 202.02 307.82 6.79153 10.0 0.79949 0.034873 111.66 197.88 309.55 7.87684 15.0 0.81131 0.030105 117.61 193.55 311.17 9.08749 20.0 0.82387 0.026084 123.65 189.01 312.67

Pressure Enthalpy Diagram The figures in Table 2 have been taken from Tables of Refrigerant Properties, which fully define all the thermodynamic characteristics of refrigerant R22. The detailed operating characteristics of a working vapour compression system can be plotted on this diagram. The Vapour Compression Cycle FIG 2 The primary purpose of an air conditioning or refrigeration system is to remove heat energy at a low temperature from a conditioned space or body and transfer (reject) this heat energy into another medium at a higher temperature. Heat energy may be rejected into air, water or soil. This process is very often continuous since heat energy will always continue to flow from higher temperature surroundings into the conditioned space being maintained at lower temperature. Insulation plays a major part in minimising this heat energy flow in low temperature applications.

Air Conditioning & Refrigeration Heat Load Heat energy flow from higher temperature surroundings through the fabric of the conditioned space are termed Transmission or Conducted gains. There are many other sources of heat gain to the conditioned space and these include heat energy from: Solar radiation energy striking the surfaces of the building or cold store (Sensible) Warm, moist air entering the conditioned space through infiltration or ventilation (Sensible & Latent) Products or processes (Sensible and Latent) Lighting, motors, machinery and computers (Sensible) Occupants (Sensible and Latent) These are carefully calculated and the total is popularly known as the Heat Load or Cooling Load. The Heat Load normally comprises Sensible Heat and Latent Heat and the air conditioning or refrigeration system must be capable of removing these continuously. The sum of Sensible and Latent Heat energy is known as Total Heat or Total Enthalpy. Air conditioning and refrigeration loads will be discussed later in the series. The Evaporator Since the capacity of a refrigerant to absorb heat energy is greatest when changing state from liquid to vapour, the heat exchanger (Evaporator) within the conditioned space is continuously supplied with liquid refrigerant, which vaporises in order to absorb heat energy from the conditioned space. Air is used to transport sensible and latent heat energy from products, lights, machinery and occupants to the Evaporator. In order for this to be effective and efficient, an Evaporator Fan is used to pass return air over the Evaporator Coil and to distribute conditioned air throughout the space. See Figure 3. If liquid refrigerant R22 is allowed to vapourise at a pressure of 1.01325 bar, the Saturation Temperature (or Evaporating Temperature) will be 40.8 C. As the refrigerant vaporises, heat energy is absorbed and is termed Latent Heat of Vaporisation. The Latent Heat of Vaporisation (approximately 140 kj/kg) required to vaporise the liquid is taken from the conditioned space thus providing cooling. The heat energy from the space is transferred to the vapour.

FIG 3 However, in order to maintain the conditioned space at a suitable temperature for comfort air conditioning (22 C), it is not necessary for the refrigerant to change state at such a low temperature (Evaporating Temperature). The design of the evaporator and the amount of airflow will determine what Evaporating Temperature is required for a given leaving air temperature from the evaporator coil. If an Evaporating Temperature of 5 C were required, it will be necessary to raise the Evaporating Pressure to 5 bar. See Figure 4.

FIG 4 Superheat Note that some of the heat energy from the room is also raising the temperature of the refrigerant above the Saturation Temperature within the Evaporator. This Superheating of the refrigerant is essential to protect the compressor from taking in liquid refrigerant, which would otherwise result in mechanical damage and failure. However, as superheating the vapour does not absorb much heat energy from the conditioned space and also makes poor use of the evaporator, it should be maintained at a minimum level of 5.0 7.0 K. The process taking place within the Evaporator is shown on the P E Diagram in Figure 5. The amount of energy absorbed by the refrigerant during vaporisation is 167 kj/kg (Latent Heat of Vaporisation) and a further 3 kj/kg has been absorbed during Superheating of the vapour. The total of these (170 kj/kg) is equal to the amount of cooling performed in the Evaporator (and the space) and is termed the Net Refrigerating Effect.

FIG 5 The Compressor The Superheated refrigerant vapour leaving the Evaporator must be recycled and returned to liquid form for use at the Evaporator. In order for the refrigerant to be returned to a liquid state it is necessary to remove heat energy by bringing the refrigerant into contact with a medium (sink) at a lower temperature. If the system is to reject this heat energy to outdoor air during peak summer conditions where the air temperature may be as high as 30 C, the Saturation Temperature of the refrigerant must be raised from 5 C to a higher temperature than 30 C, say 40 C. This is achieved by raising the pressure of the Saturated Vapour leaving the Evaporator by passing the vapour through a Compressor. This higher Saturation Temperature is known as the Condensing Temperature. See Figure 6.

FIG 6 The process taking place within the Compressor is shown on the P E Diagram in Figure 7. Note that the compression process follows the lines of Constant Entropy. The refrigerant has taken up 23 kj/kg of energy during this process and this is termed the Heat of Compression. The resulting leaving temperature is now much higher than the entering temperature (70 C) and the Condensing Pressure has been raised to 15 bar.

FIG 7 The Condenser The Condenser must remove heat energy from the refrigerant and reject this to a lower temperature medium (sink), usually outdoor (Ambient) air. Assuming an Ambient Temperature of 30 C and a Condensing Temperature of 40 C, a temperature difference of 10 K exists. This is often known as the Approach Temperature. See Figure 8.

FIG 8 Total Heat of Rejection The energy that must be rejected by the Condenser comprises the heat energy removed by each kilogram of refrigerant passing through the Evaporator (170 kj/kg) and the heat energy added to each kilogram of refrigerant passing through the Compressor (23 kj/kg). The total heat that must be rejected therefore equals 193 kj/kg and is termed the Total Heat of Rejection (THR). The Condenser coil is therefore normally larger than the Evaporator coil. The gas leaving the Compressor and entering the Condenser is considerably superheated. The Condenser must therefore Desuperheat the refrigerant first by 30 K until the Saturation Temperature of 40 C is reached. (70 40 = 30 K). When the refrigerant has reached the Saturation Temperature, the Condenser will then remove substantial latent heat energy as the refrigerant changes state from Saturated Vapour to Saturated Liquid. This energy is known as the Latent Heat of Condensation. (417 250 = 167 kj/kg). The Condenser normally holds a small amount of liquid refrigerant at the base of the coil. If the system is fitted with a Liquid Receiver, the Condenser coil holds very little liquid refrigerant, as this is

stored in the Liquid Receiver. This liquid, at a starting temperature of 40 C, loses further heat energy to the air passing over the coil at 30 C (and whilst residing in a Liquid Receiver). This causes the liquid refrigerant to be Sub Cooled to a temperature below the Saturation Temperature. FIG 9 Figure 9 shows a loss of 10 kj/kg due to Sub Cooling in the Condenser Coil and the Liquid Receiver (250 240 kj/kg). The process through the Condenser and Liquid Receiver on the P E Diagram is illustrated in Figure 9. The Expansion Device The refrigerant is now available as a high pressure, Sub Cooled liquid for return to the Evaporator coil via the Expansion Device. This is normally a regulating valve (TEV Thermostatic Expansion Valve) with a sensor attached to the external surface of the refrigerant pipe leaving the Evaporator coil. The TEV regulates the flow of liquid refrigerant into the Evaporator coil by maintaining a preset Superheat value at the Evaporator coil outlet. This ensures that the Evaporator is adequately supplied with liquid refrigerant to meet the instantaneous cooling load and that the Superheat is correctly maintained at a level, which ensures the best utilisation of Evaporator capacity, whilst ensuring liquid refrigerant, does not return to the Compressor. The TEV will be studied in greater detail later in the series. Liquid refrigerant enters the TEV at 15 bar, a Saturation Temperature of 40 C and at a temperature of 32.5 C. As the liquid refrigerant passes through the valve from the

high pressure region to the low pressure region, the pressure drops top 5 bar causing the Saturation Temperature to fall immediately to 5 C at 5 bar. Flash Gas FIG 10 The drop in pressure forces the refrigerant to immediately drop in temperature from 32.5 C to 5 C and a portion of the refrigerant is vaporised (Flash Gas) as the remainder rejects heat energy. This is effectively a loss of refrigeration capacity since less liquid refrigerant is now available for subsequent cooling within the Evaporator. The balance of liquid refrigerant remaining vaporises within the Evaporator and is Superheated by approximately 5 7 K. The cooling effect resulting from this process is known as the Net Refrigerating Effect. The Flash Gas process does not result in any change of energy since the remaining liquid has lost an equal amount of energy to that gained by the vapour produced.