Emergency Voice Communication Systems EVCS Network 8 Data Sheet

Similar documents
Emergency Voice Communication Systems EVCS Network 8 Data Sheet

Emergency voice communications Product Name

Sound Engineering for 60 Years EmerCall Disabled Refuge and Fire Telephone System

VoCALL - CFVCM/CFVCWM & CFVCX8. Fire Telephone & Disabled Refuge Network System. User Manual & Log Book

Repeaters and Mimics Data Sheet

GUARDIAN REFUGE & EMERGENCY VOICE COMMUNICATION SYSTEMS

Emergency Voice Communication Systems

Communication A BRITISH MANUFACTURER. Features:

EMERCALL FIRE TELEPHONE AND DISABLED REFUGE APPLICATION & DESIGN GUIDE - AUGUST 2007

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

CB200W Water Leak Detection Panel Application Guide

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

SigTEL EVC System. Operator Instructions

Premier M Plus & Infinity 8

Operation and Installation Manual

TELEPHONES Accessories. Phones. parts. Keypad Telephones Auto Dial. Courtesy Inmate Telephones. Hands-Free Telephone. Catalog.

Conventional Fire Detection and Extinguishant Control System Specification

The telephone has three soft-touch silicone rubber push buttons that can be backlit and each has a clear and precise function symbol;

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

FIREDEX Conventional Fire Panels

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

Setting Up the Cisco Unified IP Phone

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

Mitel DECT Base Stations

NGSS Data Consolidator (DC)

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Cisco Model SPA 303 Quick Start Guide

TrueAlarm Fire Alarm Systems

Masterseal Plus TM. ingress protected wiring devices. technical hotline +44 (0) IP66. Improved catch.

Magnum Mobile Generator MMG55 Specifications

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

C E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems

A-307. Mobile Data Terminal. Android OS Platform Datasheet

Cisco Unified IP Phone 7960G

HP UPS R1500 Generation 3

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

Product Overview Brochure. Flexibility to design a fire system that best suits you

Fire. The Fire Installers Mate. A guide to fire alarm systems design

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

4000 Series audio door entry system (using power supply) Installation Instructions IN9307.1

VEGA Analogue Addressable Control Panels

Setting Up the Cisco Unified IP Phones

Quick start guide to your IP phone

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

TELEPHONE ACCESS CONTROL ENTRY STATIONS

HMI display Installation Guide

HM-W536 Install Guide

Enterprise Telephone. Model OPERATING INSTRUCTIONS

Innovative DOOR STATION Solutions

Points Position Indicator (PPI1) for Points Motors with Common Ground

Paxton Compact panel Mount Reader

CISCO UNIFIED IP PHONE 7960G

OZW30. Central Unit SYNERGYR

Drayton Digistat +2RF/+3RF

Product Specification instalert Rapid Messenger Variable Message Sign

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

RADAR

MidiStream. UHF Wireless MIDI System Operating Manual

Personal Assistance System Owner's Guide

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

An intercom completes any access control system by providing a means for the user of screening visitors before granting access, thereby significantly

Routefinder Testing and reporting for emergency lighting systems

Your Phone This section introduces you to the hardware of the device.

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

Enterphone Solo. User/Installation Manual Part No

AC-115 Compact Networked Single Door Controller. Installation and User Manual

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

This Document Contains:

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Part 2. Copyright 1998 Philips Consumer Communications L.P. All rights reserved. Printed in Mexico. Issue 1AT&T

OM2260VW2 USER MANUAL VERIZON WIRELESS HOME PHONE CONNECT

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

SERVER ROOM CABINET INSTALLATION CONCEPTS

OPERATING INSTRUCTIONS

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

38. ACCESS CONTROL AND ELECTRONIC SECURITY SYSTEM

Quick start guide to your IP phone

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

welcome to our world fire alarm systems - series 600

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

Thinix ipad Kiosk Hardware and Accessories

200 Range Dialer Installation Manual. Version 1.0

Model SPA 303G Quick Start Guide

Monitors. Platea Monitor

Digital Keypad Use s Manual

User Guide BT CONVERSE 425

3. MOUNTING THE FIRE ALARM PANEL PLANNING CABLE ENTRY 3.2 FIXING THE BACKBOX TO THE WALL

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications

Hotel Accessibility Pack

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

POINTS POSITION INDICATOR PPI4

Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version

Emergency Telephone Systems

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

INSTRUCTION MANUAL OVERVIEW Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series.

Transcription:

Emergency Voice Communication Systems EVCS Network 8 Data Sheet The Emergency Voice Communications System (EVCS) Network 8 is for use as a Fire Telephone system, Disabled Refuge Call system or as a combined system when both Fire Telephones and Disabled Refuge Points are required. Features Fully monitored stand alone system Complies with BS5839 Part 9 Fully addressable Duplex two way communication System flexibility Multiple line conversations Up to 8 master handsets Up to 256 outstations In addition to Type A and Type B Outstation can also monitor Emergency Assist Alarms (using a 2 core radial) Designed to comply with BS5839 Part 9 2003 the EVCS is a fixed, secure, bidirectional fullyduplex voice communication system, to assist fire fighters within high rise buildings or large sites where radio communication may not be possible. Where both a fire telephone and disabled refuge system are fitted to a building BS 5839 Part 9 specifies these should form a single system. The EVCS consists of three main components; the master handset (EVCSMS), the exchanges units (EVCSXC), and outstations (type A or type B as appropriate). Control of EVCS is simplicity itself, the master handset has a clear, four line backlit display which shows the calling outstation name in plain text. Calls can be made to outstations by either dialling the number of the unit, or choosing the name from a text dialling directory, with conference calling possible. Each Exchange unit connects to a data highway and is locally powered, with internal battery backup from a monitored, maintained sealed lead acid battery. Up to eight lines can be connected to each distributed exchange, and each line can have up to four phones (BS5839 Part 9 recommends one phone per line, however this facility is required in some retro fits). Two types of user outstation are available as described in BS5839 Part 9, Type A uses handsets, either flush or surface mounting. Type B outstations are hands free units with echo cancellation and noise reduction. All EVCS handsets have a T coil for hearing aid users. Installation Master Handsets and exchange units are connected on a single data highway consisting of 2 x 4 core fire rated cables. Up to 8 Master Handsets and 32 exchanges may be connected to this highway. Master Handsets may be desk or wall mounted and has a 19 rack mounting option. Exchange units are supplied in a mild steel enclosure suitable for wall mounting. Each Exchange unit has 8 outstation lines for connection of Type A (telephone), Type B (hands free) stations or Emergancy Assist Alarm systems. These are connected to the Exchange unit with a 2 core fire rated cable with field wiring when an outstation is connected. This document is not intended to be used for installation purposes. Every care has been taken in the preparation of this document but no liability can be accepted for the use of the information therein. Design features may be changed or amended without prior notice. For more information, contact: NOTIFIER. Charles Avenue, Burgess Hill, West Sussex, RH15 9UF. United Kingdom Phone: +44 (0) 1444 230 300 Fax: +44 (0) 1444 230 888 Page 1 of 11 990130_0213 ISO9001 Design, Manufacture and Supply to Quality Management Systems Certified to ISO9001:1994

EVCS Network 8 Master Handset EVCSMS EVCS Network 8 is a system for larger Disabled Refuge and Emergency telephone installations. Its distributed loop architecture provides a competitive system from 8 to 256 communication points as well as multiple control locations. Control of the EVCS is simplicity itself. The Network 8 System Master Handset allows swift identification of outstations via its onboard directory and clear backlit display. The master console has a clear four line backlit display which shows the calling outstation name in plain text, and calls can be made to outstations by either dialling the number of the unit, or choosing the name from a text dialling directory. The EVCS Network 8 system also enables Notifier Emergency Assist Alarm systems to be connected directly. EVCS Master Handset EVCSMS Indication and Controls Fault LEDs Status LEDs LCD Keyboard Navigation Network Cables Type 268 mm 275 mm 1.49 kg 4 off yellow (General, Panel, Supply & Exchange) 4 off green (Healthy, AC, DC & Network) High contrast blue/white LCD, four line twentycharacter 5x8 pixel format 12 key telephone style 3 keys (Left, Accept,Right) Fire rated (some installations will require enhanced cabling). Cores 1 off four Pair (eg Draka 910245) or 2 off four core 1mm CSA Soft Skin or 4 off 1 Pair MICC Twisted 500M soft skin, 300M MICC Data and phantom voltage Power Supply Source Voltage Current Processing Clock Memory Standards Compliance EMC Product Family Network Port x2 11V to 18V DC 88mA @ 12V 16MHz 4K RAM 20K EEProm 128K Flash Asynchronous Watchdog checksum on EEPROM & Flash EN551031,EN551032 BS5839pt9, BS9999 Page 2 of 11 990130_0213

EVCS Network 8 Master Handset Wall Mounted EVCSMSWM EVCS Network 8 is a system for larger Disabled Refuge and Emergency telephone installations. Its distributed loop architecture provides a competitive system from 8 to 256 communication points as well as multiple control locations. Control of the EVCS is simplicity itself. The Network 8 System Master Handset allows swift identification of outstations via its onboard directory and clear backlit display. The master console has a clear four line backlit display which shows the calling outstation name in plain text, and calls can be made to outstations by either dialling the number of the unit, or choosing the name from a text dialling directory. The wall mount case is made from powder coated zintec and is fitted with 20mm cable knockouts for all cables needed. The EVCS Network 8 system also enables Notifier Emergency Assist Alarm systems to be connected directly. EVCS Master Handset EVCSMSWM Material Indication and Controls Fault LEDs Status LEDs LCD Keyboard Navigation Network Cables Type 300 mm 300 mm 90 mm 6.5 kg Zintec, Texture Powder Coated, RAL7032 4 off yellow (General, Panel, Supply & Exchange) 4 off green (Healthy, AC, DC & Network) High contrast blue/white LCD, four line twentycharacter 5x8 pixel format 12 key telephone style 3 keys (Left, Accept,Right) Fire rated (some installations will require enhanced cabling). Cores 1 off four Pair (eg Draka 910245) or 2 off four core 1mm CSA Soft Skin or 4 off 1 Pair MICC Twisted 500M soft skin, 300M MICC Data and phantom voltage Power Supply Source Voltage Current Processing Clock Memory Standards Compliance EMC Product Family Network Port x2 11V to 18V dc 88mA @ 12V dc 16MHz 4K RAM 20K EEProm 128K Flash Asynchronous Watchdog checksum on EEPROM & Flash EN551031,EN551032 BS5839pt9, BS9999 300 mm 300 mm 90mm Page 3 of 11 990130_0213

EVCS Network 8 Exchange Unit EVCSXC The Network Exchange Unit delivers an efficient solution for larger EVCS sites. Providing a power supply for System Master Handsets, its distributed loop based architecture provides a competitive scalable system for up to 256 communication points. Each Exchange unit sits on a data highway and is locally powered, with internal battery backup from a monitored, maintained sealed lead acid battery. Up to eight lines can be connected to each distributed exchange, and each line is fully monitored for Open, Short or Earth faults. The network comprises a line or ring of 8 cores (see below), each leg can be upto 500M depending on cable type. A ring topology is recommended by 5839 pt9. Line cables consist of a single two core enhanced cable, either soft skin types or MICC and only 1mm CSA is required. Up to thirtytwo Network 8 Exchanges can be fitted to a the system giving a maximum system size of 256 independent lines. EVCS Network 8 Exchange Unit EVCSXC 296 mm 210 mm 82 mm 1.6 kg Indication and Controls Fault LEDs 10 off yellow (General, PSU, 8 lines) Status LEDs 2 off green (AC & DC) Settings 8 way DIP switch Outstation Cables Grade Enhanced Cable (per Line) 1 off 2 core (twisted for MICC) (per leg) 500M soft Skin types, 300M MICC DC open, short & earth Network Cables Type Enhanced Cores 1 off four pair (eg Draka 910245) or 2 off four core 1mm CSA Soft Skin or 4 off 1 Pair MICC Twisted 500M soft Skin, 300M MICC Power Supply Voltage 230V AC ± 20% Current 11mA Battery 12V SLA 3.2AH Charger 1A Controlled Impedance Open, Short & High Impedance cell Standards Compliance EMC EN551031,EN551032 LVD EN6100032, EN6100033, EN60950 Product Family BS5839pt9, BS9999, EN544 Page 4 of 11 990130_0213

Type A Outstation EVCSHSP & EVCSHFP The EVCS Type A outstation is designed to fully comply with BS5839Part 9:2003 for use as a Fire Telephone system, Disabled Refuge Call system or as a combined system when both Fire Telephones and Disabled Refuge Points are required. The Type A outstation is a monitored phone handset providing full duplex speech capability. The unit is available as a surface mounting or flush mounting unit cased in a metal wall mounting enclosure. The EVCS type A Outstation is a slick compact unit which offers easy access via a magnetic push catch door and a unique front levelling system allowing the back box to be mounted at a slight angle whilst still retaining a true front face and door. Compatible with all EVC systems for use as a standard Fire Telephone or Disabled Refuge call point. EVCS Type A Outstation EVCSHSP (Surface Mounting) 320 mm 152 mm 1.4 Kg (no batteries) EVCSHFP (Flush Mounting) Dimensions (with bezel): Dimensions (backbox hole): 334 mm 191 mm 320 mm 152 mm 1.4 Kg (no batteries) Fully monitored connections. Status LED Flashing when ringing Dimly lit to indicate surveillance Standards DC open, DC Short and Earth Fault EMC: EN 551031 & EN 551032 LVD: EN 60950 Product Family: Surface mounting enclosure BS 5839 9 & BS 9999 & EN 601184 Features Telephone type handset Automatic dialling to Master Handset when off hook Telecoil for hearing impaired users Magnetic push catch door EVCSHFPSS Flush Mount EVCSHSPSS Surface Mount Flush mounting enclosure 334mm 320mm 191mm 85mm 152mm 85mm Page 5 of 11 990130_0213

Type A Outstation Stainless Steel EVCSHSPSS & EVCSHFPSS The EVCS Type A outstation is designed to fully comply with BS5839Part 9:2003 for use as a Fire Telephone system, Disabled Refuge Call system or as a combined system when both Fire Telephones and Disabled Refuge Points are required. The Type A outstation is a monitored phone handset providing full duplex speech capability. The unit is available as a surface mounting or flush mounting unit cased in a metal wall mounting enclosure. The EVCS type A Outstation is a slick compact unit which offers easy access via a magnetic push catch door and a unique front levelling system allowing the back box to be mounted at a slight angle whilst still retaining a true front face and door. Compatible with all EVC systems for use as a standard Fire Telephone or Disabled Refuge call point. EVCS Type A Outstation Stainless Steel EVCSHSPSS (Surface Mounting) 320 mm 152 mm 1.4 Kg (no batteries) EVCSHFPSS (Flush Mounting) Dimensions (with bezel): Dimensions (backbox hole): 334 mm 191 mm 320 mm 152 mm 1.4 Kg (no batteries) Fully monitored connections. Status LED Flashing when ringing Dimly lit to indicate surveillance Standards DC open, DC Short and Earth Fault EMC: EN 551031 & EN 551032 LVD: EN 60950 Product Family: BS 5839 9 & BS 9999 & EN 601184 Features Telephone type handset Automatic dialling to Master Handset when off hook Telecoil for hearing impaired users Magnetic push catch door EVCSHFPSS Flush Mount EVCSHSPSS Surface Mount 334mm 320mm 191mm 85mm 152mm 85mm Page 6 of 11 990130_0213

Type A Outstation IP65 Lockable Surface Mount EVCSHFW The EVCS Type A outstation is designed to fully comply with BS5839Part 9:2003 for use as a Fire Telephone system, Disabled Refuge Call system or as a combined system when both Fire Telephones and Disabled Refuge Points are required. The Type A outstation is a monitored phone handset providing full duplex speech capability. The unit is available as a surface mounting or flush mounting unit cased in a metal wall mounting enclosure. The EVCSHFW is a type A EVCS outstation compatible with the Notifier Compact and Network systems. It is supplied in an IP65 case fitted with a standard firemans key lock to prevent unauthorised use. Type A Outstation IP65 Lockable Surface Mount EVCSHFW Material Colour Outstation Cables Type Cores Features Telephone type handset 300 mm 200 mm 120 mm 2.5 Kg Zintec, Powder coated RAL7035 Grey Enhanced 2 core 1mm or 1.5mm 500m Automatic dialling to Master Handset when off hook Telecoil for hearing impaired users Fitted with a standard firemans key lock to prevent unauthorised use Fully monitored connections. Status LED Flashing when ringing Dimly lit to indicate surveillance Standards EMC LVD Product Family: Mounting The Unit DC open, DC Short and Earth Fault EN551031, EN551032 EN60950 BS 5839 9 & BS 9999 & EN 601184 The Handset should be mounted at a height of either 1200mm from the fioor, or on a 1400mm centre line to comply with the requirements of Building Regulations Document M (Access for the Disabled). The back box has four indented feet to allow mounting on uneven walls. If the unit is to be used as a refuge point suitable space must be allowed to the side of the unit to allow a wheelchair to be parked for using the system. 300mm 200mm 120mm Page 7 of 11 990130_0213

Type B Outstation EVCSHSBG, EVCSHSB, EVCSHSFSS The EVCS Type B outstation is designed to fully comply with BS5839Part 9:2003 for use as a Fire Telephone system, Disabled Refuge Call system or as a combined system when both Fire Telephones and Disabled Refuge Points are required. The Type B outstation is a fixed, monitored and maintained, bidirectional, full duplex voice communication system to assist the orderly evacuation of disabled or mobility impaired people and enhance fire fighters communication during emergencies. Please note: When choosing the outstation type for use with an EVCS we recommend reading Section 11 of BS58399:2003 which deals with outstation types. Type B outstations can only be used where the background noise is below 40dBA (therefore there can be no sounder or voice alarm coverage in the area). Type B Outstation Construction Colour 133 mm 133 mm 45 mm 1.1Kg Zintec powder coated Green, Red or Stainless Steel Fully monitored connections. Outstation Cables Cores Indications & Controls Status Call Cancel Hands Free Communications DC open, DC Short and Earth Fault 2 core 1mm or 1.5mm 500m LEDs 2 off red flashes location, lights solid in use Press to call button Press to cancel button Push button dialling to EVCS Master Handset Echo cancellation Noise reduction Induction loop output for hearing impaired users Push button cancel Braille Signage Standards EMC: LVD: Product Family: Mounting The Unit EN551031 & EN551032 EN60950 BS5839 Pt9 & BS9999 All Type B Outstations should be mounted at a height of either 1200mm from the floor, or on a 1400mm centre line to comply with the requirements of Building Regulations Document M (access for the disabled). The back box has 4 indented feet to allow mounting on uneven walls. Type B Outstations can be flush mounted by cutting a hole 133mm x 133mm and 45mm deep, and using the stainless steel bezel to finish the surround. Page 8 of 11 990130_0213

Roaming Handset and Jack Plate The Roaming Handset and Jack plate are designed to provide a cost effective solution for Fire Telephones in high rise buildings. Notifier s range of EVCS systems cover a wide range of building sizes providing high quality full duplex Emergency Voice Communication. The Roaming Handset is used along with the Jack Plate for Emergency Voice Communication System installations in countries whose fire codes allow for Roaming Handsets*. When used together, the Roaming Handset and Jack Plate form a Type A Outstation which is compatible with all EVCS systems. Low noise high quality telephone jack with Telecoil for hearing impaired users. Stainless steel jack plate can be surface or flush mounted Jack Plate Roaming Handset Construction Outstation Cables Cores End of Line 86 mm 86 mm 25 mm 140g Brushed stainless steel 2 core 1mm or 1.5mm 500m 10K 1/4 W Construction Connection Standards Compliance EMC LVD 210 mm 66 mm 45 mm 700g ABS UL90V1 1/4 mono neutrik heavy duty jack EN551031,EN551032 EN60950 Controls Fully monitored connections. DC open, DC Short and Earth Fault Call Automatic off hook dialing *These units are not suitable for installation in the UK to BS5839 Pt9 Page 9 of 11 990130_0213

Emergency Assist Alarm Kit EVCSTA The Emergency assist alarm kit has been specifically designed to integrate disabled call functions into the EVCS Network or EVCS Compact ranges providing the perfect solution for conformity with the Building regulations Document M and Equality Act 2010. The Emergency Assist Alarm Kit solution is fully monitored and battery backed by the EVCS system, saving local power supplies and giving confidence in the system integrity. The Emergency Assist Alarm Kit shows up as a call on the EVCS system, but has no speech path so a conversation cannot be had with the occupant, use of the Type B Outstations would allow this. Features Monitored to BS 5839 9 Remote powered from EVCS exchange Dual loop pull cord High contrast labels Braille on cancel plate Blue indication Benefits No PSU is required remote powered by EVCS system All calls from disabled toilets and refuge points monitored from one location Tactile braille signage to assist partially sighted people Emergency Assist Alarm Kit EVCSTA Over door indicator Dimensions: 31.5 mm : Operating voltage: 12V dc (nominal) Physical: Construction: PC Cancel button Dimensions: 25 mm : Operating voltage: 12V dc (nominal) Physical: Construction: PC Pull cord unit Dimensions: 30.5 mm : Operating voltage: 12V dc (nominal) Physical: Construction: PC Wiring Guide Using 2 Core Cable Power Supply Pull Cord Unit + 12V + + + IN OUT Over Door Indicator + + IN OUT Cancel Unit OUT EVCS Exchange Over Door Indicator Cancel Unit IN Over Door Indicator Cancel Unit Pull Cord Unit Page 10 of 11 990130_0213

Product Range at a Glance Part Number EVCS Master Handset Desk/Wall Mount EVCSMS Network 8 Master Handset Wall Mounted EVCSMSWM 8 Way Exchange Unit/Charger. EVCSXC Flush Outstation Push Door. Type A EVCSHFP Flush Outstation Type A, Push Door, Stainless Steel EVCSHFPSS Surface Outstation. Push Door. Type A EVCSHSP Surface Outstation Type A, Push Door, Stainless Steel EVCSHSPSS Weatherproof Type A Outstation EVCSHFW Surface Outstation, Type B, Green EVCSHSBG Surface Outstation, Type B, Red EVCSHSB Surface Outstation, Type B Stainless Steel EVCSHSFSS Wall Jack Outlet Point EVCSWJP Loose Handset with Jack Lead EVCSHLJ Emergency Assist Alarm Kit (without PSU) EVCSTA EVCSHSB Stainless Steel flush mounting bezel EVCSVCFHB EVCSMS Rackmount Kit 6U. EVCSRM Page 11 of 11 990130_0213 Charles Avenue Burgess Hill W. Sussex RH15 9UF T: +44 (0) 116 246 2255 F: +44 (0) 116 246 2210 E: sales@notifierfiresystems.co.uk