Test documents issued by the FGH Engineering & Test GmbH

Similar documents
TYPE TEST CERTIFICATE OF SHORT-CIRCUIT PERFORMANCE. A three-phase outdoor oil-immersed distribution transformer

GUIDE FOR TESTING POWER TRANSFORMERS

Testing of Power Transformers. Routine tests, Type tests and Special tests

Discussion on Class I & II Terminology. IEEE PES Transformers Committee Fall Meeting 2011 Boston, MA

DS 600. A contact free flux gate based current measurement sensor 600A rms

INTERNATIONAL STANDARD

IEC ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays

DIMENSIONING OF CURRENT TRANSFORMERS FOR PROTECTON APPLICATION

Power transformers. Special transformers Railway

INTERNATIONAL STANDARD

SUITABILITY OF DIFFERENT TEST VOLTAGES FOR ON-SITE TESTING OF XLPE CABLE SYSTEMS

The standards mentioned in this document

How to design SMPS to Pass Common Mode Lightning Surge Test

Unified requirements for systems with voltages above 1 kv up to 15 kv

Guidance for upgrading to GB (IEC : 2005, MOD)

Presentation of the France Transfo factories

Technical Information Requirement for MV transformers and transformer for internal power supplies for SUNNY CENTRAL

INTERNATIONAL STANDARD

Power over Ethernet plus Isolation requirements. David Law 3Com

AMP CO Plus Insert for Cat. 6 A Applications

Voltage Regulator SPAU 341 C. Product Guide

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS

Transformer Design & Design Parameters

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS

Power Technology Issue 104. Modeling of Two-Winding Voltage Regulating Transformers for Positive Sequence Load Flow Analysis in PSS E

Electricity & Electronics 5: Alternating Current and Voltage

Inductors in AC Circuits

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

User's Guide. True RMS Industrial Multimeter

ANADOLU UNIVERSITY DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

Transformers Energy efficient transformer solutions European Minimum Energy Performance Standard (MEPS)

Disturbance Recoder SPCR 8C27. Product Guide

Properties of electrical signals

High-ohmic/high-voltage resistors

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Three-phase monitoring relay CM-PFE

TISP4600F3, TISP4700F3 OBSOLETE

Product Information Sheet UH28CS-12kV Hi Pot Tester

Gas Discharge Tubes GTCX36-XXXM-R05 Series

Rules for Classification and Construction Additional Rules and Guidelines

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

DATA SHEET THICK FILM CHIP RESISTORS Introduction

High-ohmic/high-voltage resistors

The Importance of the X/R Ratio in Low-Voltage Short Circuit Studies

Lightning current simulation in the laboratory - parameters, procedures and test equipment -

ACCURACY OF POTENTIALTRANSFORMERS

Digital Pressure Measuring Instrument MDR480

TETRIS High Impedance Active Probe. Features:

Electricity and Magnetism, Georgia, GEOSTM (Georgian National Agency for Standards and Metrology)

ε: Voltage output of Signal Generator (also called the Source voltage or Applied

TETRIS 1000 / High Impedance Active Probe Order-No: Features:

TWENTIES WORKSHOP, EWEA 2012 Unveiling the future energy system: full scale demonstrations to reach 2020 targets. 17th April 2012

Electrical Safety Tester Verification

R.C.C.B. s two-pole LEXIC

SURGE PROTECTIVE DEVICES

handbook, 2 columns handbook, halfpage 085 CS

PROPER SELECTION OF CONTROL CIRCUIT TRANSFORMERS WHITE PAPER BULLETIN 1497, 1497A, AND 1497B

Circuits with inductors and alternating currents. Chapter 20 #45, 46, 47, 49

Gas Discharge Tubes GTCX26-XXXM-R05 Series

INTERNATIONAL STANDARD

HOW TO SELECT VARISTORS

Technical Specification for Oil insulated Transformers U m < 24 kv up to 1250 kva

PC software icos Advanced

Fluke 1650B Series Multifunction Installation Testers

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

Gas Discharge Tubes GTCX38-XXXM-R10 Series

Power Technology Issue 106. Modeling of Three-Winding Voltage Regulating Transformers for Positive Sequence Load Flow Analysis in PSS E

Instrument Transformers Application Guide

Transformers. Special transformers Reactors products

5SDD 92Z0401. Housingless Welding Diode. I FAVm = A I FSM = A V TO = V Applications r T = m. Types.

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

SPECIFICATIONS FOR 220KV CAPACITOR VOLTAGE TRANSFORMER. The equipment is required for 220KV system. The system data is given as under:

Episode 126: Capacitance and the equation C =Q/V

SUPERSEDED REVISION. Gas Discharge Tubes GTCX28-XXXM-R20 Series. Features: Benefits: Applications

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) J. Instruction Leaflet

BASIC ELECTRONICS AC CIRCUIT ANALYSIS. December 2011

Two Position Cable-to-Board Power Connector System (Right Angle/Straight) with Coding Contacts

SANS : 2008 CODE OF PRACTICE THE WIRING OF PREMISES Part 1 : Low Voltage Installation

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

ENGINEERING REPORT. XYZ Corporation 100 Anyplace Drive Chicago, Illinois 60613

Protection from Short-circuit

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Zero voltage drop synthetic rectifier

Chapter 22 Further Electronics

Equipment: Power Supply, DAI, Transformer (8341), Variable resistance (8311), Variable inductance (8321), Variable capacitance (8331)

A Practical Guide to Dielectric Testing

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

IEEE802.3poep Study Group Revision of isolation requirements in IEEE802.3 clause 33.

Application Guide Film Capacitors

INTERNATIONAL STANDARD

Together we create reliable products, thus ensuring development of power industry of continents.

Automated test systems for distribution transformers Part II. Detailed analysis of the test system features EVENTS ABSTRACT KEYWORDS

Requirements for Offshore Grid Connections. in the. Grid of TenneT TSO GmbH

MOBILE SYSTEM FOR DIAGNOSIS OF HIGH VOLTAGE CABLES (132KV/220KV) VLF-200 HVCD

Model UT201/202: OPERATING MANUAL. Table of Contents

Thermistor motor protection

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

WINDING RESISTANCE TESTING

Transcription:

No. L857 Sheet 2 Test documents issued by the FGH Engineering & Test GmbH A Type Test Certificate is issued for complete type tests according to valid standards taking into account valid STL guides. Equipment to be tested must be clearly identifiable: - Apparatus by a nameplate according to the relevant standard and by suitable drawings; - Equipment for which the relevant standard does not require a nameplate, by suitable drawings and descriptions where necessary. In certain cases, a specification of details may be required. The Type Test Certificate confirms that during all tests of the equipment according to the standard the specified pass criteria for its behaviour during the tests and its conditions after the tests have been fully met. A Test Certificate is issued for equipment having passed parts of the type tests specified in the relevant standards or fulfilling accepted specifications or recommendations. Equipment to be tested must be clearly identifiable: - Apparatus by a nameplate according to the relevant standard and by suitable drawings; - Equipment for which the relevant standard does not require a nameplate, by suitable drawings and descriptions where necessary. In certain cases, a specification of details may be required. The Test Certificate confirms that during the test of the equipment according to the standard the specified pass criteria for its behaviour during the tests and its conditions after the tests have been fully met. A Test Report is issued for all tests which do not meet the requirements of a Type Test Certificate or a Test certificate and have been performed according to specifications, standards and/or clients instructions. Similarly, this test report contains all test results, details of the conditions under which the tests were performed, also details relating to the behaviour of the test object, and its condition after the tests. An Investigation Report is issued for investigations which have not the character of proving tests. A Test Confirmation is issued immediately after the tests. It confirms that the tests have been conducted and is valid only until publishing the detailed results in an entire document. Photographs and identification documents Inserted photographs and identification documents (e. g. drawings, parts lists) must bear the FGH-stamp. In case of electronic photographs the stamp can be omitted. The customer confirmed by his signature that the test object corresponds to the submitted identification documents. FGH checked the accordance for essential details. The original identification documents were stamped and signed by FGH. If this document contains electronic identification documents without FGH-stamp, the conformance with the checked, stamped and signed original documents has been verified by FGH. With reference to ISO/IEC 1725 the FGH Engineering & Test GmbH states: - The FGH Engineering & Test GmbH apply the PEHLA Procedure No. 12 for determining the uncertainties of measurement. As long as no explicit statements are made, the uncertainties required by the relevant standards have been complied with. - The accreditation of the FGH Engineering & Test GmbH or its test documents by themselves in no way constitute or imply product approval by DATech or any other body. - If a client refers to the accreditation of the FGH Engineering & Test GmbH, the reference shall include the accreditation body DATech, the relevant scope of the accreditation and the appropriate registration number. - The test results included in the test documents as well as their evaluation relate exclusively to items tested. - The test documents may not be reproduced, except in full contents, without written approval by the FGH Engineering & Test GmbH.

No. L857 Sheet 3 1 Contents Test documents issued by the FGH Engineering & Test GmbH...2 1 Contents...3 2 Participants...4 3 Transformer under Test...5 3.1 Rating Plate of transformer...6 3.2 Outline drawing of transformer...7 3.3 Part list...8 3.4 Test Report of manufacturer...9 4 Routine Tests...1 5 Test of Short-circuit strength...11 5.1 Test Circuit and Measurement...11 5.2 Test Results...12 6 Lightning Impulse Voltage Withstand Test...13 6.1 Test procedure...13 6.2 Technical data of the impulse generator:...13 6.3 Test results...14 7 Results of Routine tests...15 8 Inspection of Active part...16 9 Oscillograms...2 9.1 Test of Short-circuit strength - Oscillograms...2 9.2 Lightning Impulse Voltage Withstand Test - Oscillograms...29

No. L857 Sheet 4 2 Participants Name Date Company Mr. Benjamin Vainshtein 2.-8.7.8 Israel Electric Company Mr. Eugeni Farberon 2.-4.7.8 ARDAN Mr. Eyal Sayar-Nitsan 2.-4.7.8 ARDAN Mr. Paul Khait 7.-8.7.8 ARDAN Mr. Haim Nudelman 7.-8.7.8 ARDAN Mr. Robert Deutsch 2.-8.7.8 FGH Engineering & Test GmbH Mr. Andre Röhner 2.-8.7.8 FGH Engineering & Test GmbH Dr. Stephan Finke 2.-7.7.8 FGH Engineering & Test GmbH Mr. Karl Haitz 7.-8.7.8 FGH Engineering & Test GmbH

No. L857 Sheet 5 3 Transformer under Test Apparatus: Manufacturer: 3-Phase oil-immersed-type transformer with conservator Ardan Electrical Industries Type: DOTL 63/22 Serial-no.: AR/8/9632/1 Rated power: 63 kva Year of manufacture: 28 Rated voltage: 22±5%/,4 kv Rated frequency: 5 Hz Vector group: Dyn 11 LI // AC: 125/- kv // 5/3 kv Max. duration of short-circuit: 2 s Rated impedance voltage: 4,1 % Type of cooling: ONAN List of drawings submitted for identification: Title Drawing-no. Date / Rev. Sheet Rating plate at transformer AR/8/9632/1 5 Rating plate of transformer 9.632..1 25.3.8 / 2 6 Outline drawing of transformer 9.632.. page 1/2 4.6.8 / 4 7 Content and Part list of outline drawing 9.632.. page 2/2 4.6.8 / 4 8 Test report of Ardan Electrical Industries AR/8/9632/1 21.5.8 9 Identification documents not enclosed in this document are kept in the manufacturers files. Rating Plate at transformer

No. L857 Sheet 6 3.1 Rating Plate of transformer

No. L857 Sheet 7 3.2 Outline drawing of transformer

No. L857 Sheet 8 3.3 Part list

No. L857 Sheet 9 3.4 Test Report of manufacturer

No. L857 Sheet 1 4 Routine Tests (before short-circuit test) Measurement of voltage ratio and check of voltage vector relationship Tap Rated measured values (deviation to rated value) position value A - B / a - n B - C / b - n C - A / c - n 1 1,3 1,2 ( -,1% ) 1,2 ( -,1% ) 1,2 ( -,1% ) 2 95,26 95,34 ( +,8% ) 95,34 ( +,8% ) 95,34 ( +,8% ) 3 9,5 9,59 ( +,1% ) 9,59 ( +,1% ) 9,59 ( +,1% ) Connection symbol Dyn11 verified Measurement of winding resistance Temperature 29,4 C Tap measured values on terminals position A - B B - C C - A Average 1 ( 23,1 kv ) 2 ( 22 kv ) 5,612 5,31 Ω Ω 5,65 5,311 Ω Ω 5,68 5,314 Ω Ω 5,61 5,31 Ω Ω 3 ( 2,9 kv ) 5,2 Ω 5,18 Ω 5,22 Ω 5,2 Ω a - b b - c c - a 1,537 mω 1,559 mω 1,575 mω 1,557 mω Measurement of no-load loss and current at 5 Hz U U rms I a I b I c U / Ur V V A A A 1,% 399,9 4,1 1,5722 1,939 1,7354 I A 1,467 I / I r,16% P W 77,2 P corr W 77 Measurement of impedance voltage, short-circuit impedance and load losses Temperature 28,8 C Tap position I mess I m / I r U m P m U kr u kr P kr P cur P addr short ciruit A V W V W W W 1 2 3 a-b-c 15,666 15,782 15,68 99,5% 95,5% 9,1% 945,4 858,3 748,7 4418, 4168, 3767,5 95,22 899,15 83,99 4,11% 4,9% 3,98% 4463,2 4574,2 4641,2 47,8 499,7 422,3 455,4 474,5 438,9 Correction to the reference temperature of 75 C Tap position P cur 75 P addr 75 P kr 75 u kr 75 u Rr 75 u Xr 75 Z kr 75 ϕ kr 75 short ciruit W W W Ω 1 472,4 387,5 518 4,13%,81% 4,5% 35, 78,7 2 3 a-b-c 4828,7 4949,5 43,8 373,5 5232 5323 4,11% 4,%,83%,84% 4,2% 3,91% 31,55 27,72 78,3 77,8 Separate-source voltage withstand test ( 5 Hz, 1~ ) *) **) Voltage at earthed U rv (û/ 2) U tv (û/ 2) U rv / U tv Test duration Result HV LV, Vessel 5, kv 5, kv 6 s passed 1% LV HV, Vessel 3, kv 3, kv 6 s passed *) **) U rv = Rated withstand voltage U tv = Applied test voltage Induced overvoltage withstand test (15 Hz, 3~,) *) **) Voltage at earthed U 2rv (û/ 2) U tv (û/ 2) a-b-c Vessel 8 V 8 V U 2rv = 2 x Rated voltage *) **) U rv / U tv Test duration Result 1% 4 s passed U tv = Applied test voltage

No. L857 Sheet 11 5 Test of Short-circuit strength 5.1 Test Circuit and Measurement Test-No. 141-8/ 29-298 Phases/Poles Test circuit Transformer under test 3-phases 3-phases Power frequency Hz 5 Testing transformer Short-circuit point Connection symbol Secondary neutral - Yd1 a-b-c-n-grounding terminal / frame short-circuited and earthed Short-circuit apparent power MVA 5 Current i 1 : Current transformer 2A / 1A i 2 : Rogowski-coil 5,3 ka / s Voltage u T : Voltage transformer 35 kv /,1 kv

No. L857 Sheet 12 5.2 Test Results Test-no. 141-8/ 29 291 292 293 294 295 296 297 298 Tap-Position 2 2 2 1 1 1 3 3 3 Corresp. Voltage kv 22, 22, 22, 23,1 23,1 23,1 2,9 2,9 2,9 Circuit closed at zero voltage B-C B-C B-C A-B A-B A-B C-A C-A C-A No-load voltage kv 22, 22, 22, 22,8 22,8 22,5 2,9 21,2 21,4 Terminal voltage kv A-B 21,3 21,3 21,2 22,2 22,2 21,9 2,1 2,4 2,7 B-C 21,2 21,2 21,2 22,2 22,2 21,9 2,1 2,3 2,6 C-A 21,3 21,3 21,3 22,2 22,2 21,9 2,2 2,4 2,7 Mean value kv 21,3 21,3 21,3 22,2 22,2 21,9 2,1 2,4 2,6 Peak current in winding A-B 415 415 418 492 55 486 438 445 45 A B-C 52 52 517 46 47 399 437 444 45 C-A 419 419 415 39 396 38 534 544 554 Short-circuit A 39 39 39 367 368 364 419 424 43 current (r.m.s.) A B 391 391 391 367 367 365 421 426 431 on terminal C 39 39 39 368 368 362 421 426 431 Mean value A 39 39 39 367 368 364 42 425 431 Current duration ms 56 56 56 531 531 531 529 531 531 Peak current (secondary) a 4,1 4,1 39,89 49,57 5,57 47,53 4,19 39,89 42,2 ka b 49,61 49,61 49,58 41,1 4,11 38,29 4,19 41,44 4,63 c 39,85 39,85 39,52 37,25 39,25 37,92 48,59 48,93 49,69 Short-circuit a 21,76 21,76 21,69 21,35 21,3 2,85 22,16 22,4 22,74 current (r.m.s.) ka b 21,55 21,55 21,47 21,27 21,24 2,91 22,8 22,39 22,59 (secondary) c 21,36 21,36 21,28 2,94 21, 2,77 21,8 22,6 22,27 Mean value ka 21,56 21,56 21,48 21,19 21,18 2,84 22,1 22,28 22,53 Remarks: For transformers with delta connected primary windings the primary winding currents were computed from the primary line currents. This method depends on symmetry of short-circuit impedance of the transformer under test. The transformer was able to carry the short-circuit currents without any sign of deterioration. The corresponding oscillograms are plotted in this report. The pictures of the inspection of active part of transformer after all tests are integrated, too.

No. L857 Sheet 13 6 Lightning Impulse Voltage Withstand Test (after short-circuit test) 6.1 Test procedure The tests were carried out in accordance with IEC 676-3: 2-3, Clauses 13 and 14 and customers instructions. The lightning impulse voltage of negative polarity was applied to each terminal of the high-voltage windings in turn, while the other two terminals and the vessel were connected to earth. The terminals of the low-voltage windings were short-circuited and connected to earth by means a measuring-resistor R m =.8748 Ω. A test sequence of 4 impulses was applied to each terminal in the following order: 1 calibration impulse 62.5 kv full lightning voltage 3 test impulses 125 kv 6.2 Technical data of the impulse generator: Surge capacitance : Load capacitance without transformer: Front resistance: Discharge resistance: 3 nf 5,2 nf 48 Ω 21 Ω With high-voltage terminals connected to the generator the lightning impulse voltage had a virtual front time T 1 = 1.18 µs and a time to half value T 2 = 44.2 µs. The values were inside the tolerances given in IEC 66-1: 1994-6, i.e. T 1 = 1,2 µs ± 3%, T 2 = 5 µs ± 2%. For measuring the peak value of the impulse voltage an approved Impulse Measuring System connected to an resistive divider (ratio 4) was used. By means of the dual-trace transient recorder the following signals were recorded simultaneously: - the shape of the lightning impulse voltage - the voltage drop of the current across the measuring resistor R m

No. L857 Sheet 14 6.3 Test results In table 1 the impulse voltages of the test series and the relevant oscillograms are presented. There were no significant differences between the voltage and current transients recorded during the tests with full test voltages and those recorded during the test with half test voltage. The transformer has passed the tests Table 1: Lightning impulse withstand voltage test with full wave according to IEC 676-3:2-3, Clauses 13 and 14 (Tapping connector: principal tapping - pos. 2) Terminal under test Impulse No. Type of impulse *) Test voltage û/kv Oscillogram no. **) A 1 2 3 4 C T T T FW FW FW FW -62.8-124.1-124.8-125. 19962 19963 19964 19965 B 5 6 7 8 C T T T FW FW FW FW -61.8-127.5-126.3-122.3 19966 19967 19968 19969 C 9 1 11 12 C T T T FW FW FW FW -62.7-123.7-124.8-124.8 1997 19971 19972 19973 *) Kind of impulse: FW... 1% full wave lightning impulse C... calibration impulse T... test impulse **) see pages 29 to 3

No. L857 Sheet 15 7 Results of Routine tests (after short-circuit test) Separate-source voltage withstand test (5 Hz - single phase) Voltage at earthed U rv (Û/ 2) *) U t (Û/ 2) **) U t / U rv Test duration Result HV LV, Vessel 5 kv 5 kv 1 % 6 s passed LV HV, Vessel 3 kv 3 kv 1 % 6 s passed *) U rv = rated withstand voltage **) U t = test voltage (applied) Induced overvoltage withstand test (15 Hz - three phase) Tap changer Voltage at earthed U 2rv (Û/ 2) *) U t (Û/ 2) **) U t / U 2rv Test duration Result 22 kv / 2 a-b-c Vessel 8 V 8 V 1 % 4 s passed *) U 2rv = 2 * rated voltage **) U t = test voltage (applied)

No. L857 Sheet 16 8 Inspection of Active part The inspection of the active part of transformer after all tests did not show any defect, which might endanger the safe operation of transformer. Nonetheless small wooden distance sticks of stray channel between HV- and LV-winding fell down (2 in phase A, 1 in phase B) on LV-terminal side and the glue of one lower wooden support block was loosened, but block still in position. The transformer passed the Short-circuit test. Condition of transformer see following figures: Fig. 1 Tested transformer (HV terminal side) after short-circuit test Fig. 2 Tested transformer (LV terminal side) after short-circuit test

No. L857 Sheet 17 Fig. 3 Active part of tested transformer (HV-terminal side) after all tests Fig. 4 Active part of tested transformer (LV-terminal side) after all tests

No. L857 Sheet 18 Fig. 5 Side view (phase A) of active part after all tests Fig. 6 Side view (phase C) of active part after all tests

No. L857 Sheet 19 Fig. 7 Exemplary photograph (phase C) of small distance sticks of stray channel between HV- and LV-winding

No. L857 Sheet 2 9 Oscillograms 9.1 Test of Short-circuit strength - Oscillograms

No. L857 Sheet 21

No. L857 Sheet 22

No. L857 Sheet 23

No. L857 Sheet 24

No. L857 Sheet 25

No. L857 Sheet 26

No. L857 Sheet 27

No. L857 Sheet 28

No. L857 Sheet 29 9.2 Lightning Impulse Voltage Withstand Test - Oscillograms TB1=2.MS/s % 1% 3% -2kV 5% -4kV 7% 9% -6kV 1% LI: A - RW(5.%) Nr.: 19962 Terminal: A Eval.: LI Up= -62.79kV beta= 2.5% T1= 1.15µs T2= 43.5µs Terminal: TB1=2.MS/s % 1% 3% -4kV 5% -8kV 7% 9% 1% -12kV LI: A - FW(1.%) Nr.: 19963 Terminal: A Eval.: LI Up= -124.1kV beta= 2.5% T1= 1.17µs T2= 44.2µs Terminal: -8kV -16kV 2.µs 4.µs 6.µs 8.µs 1µs TB1=2.MS/s 2.µs 4.µs 6.µs 8.µs 1µs TB1=2.MS/s 2.µs 4.µs 6.µs 8.µs 1µs 2.µs 4.µs 6.µs 8.µs 1µs TB1=2.MS/s % 1% 3% -4kV 5% -8kV 7% 9% -12kV 1% LI: A - FW(1.%) Nr.: 19964 Terminal: A Eval.: LI Up= -124.8kV beta= 2.5% T1= 1.17µs T2= 44.2µs Terminal: TB1=2.MS/s % 1% 3% -4kV 5% -8kV 7% 9% -12kV 1% LI: A - FW(1.%) Nr.: 19965 Terminal: A Eval.: LI Up= -125.kV beta= 2.5% T1= 1.17µs T2= 44.3µs Terminal: -16kV -16kV 2.µs 4.µs 6.µs 8.µs 1µs TB1=2.MS/s 2.µs 4.µs 6.µs 8.µs 1µs TB1=2.MS/s 2.µs 4.µs 6.µs 8.µs 1µs 2.µs 4.µs 6.µs 8.µs 1µs TB1=2.MS/s % 1% 3% -2kV 5% -4kV 7% 9% 1% -6kV LI: B - RW(5.%) Nr.: 19966 Terminal: B Eval.: LI Up= -61.84kV beta= 2.7% T1= 1.14µs T2= 43.8µs Terminal: TB1=2.MS/s % 1% 3% -4kV 5% -8kV 7% 9% -12kV 1% LI: B - FW(1.%) Nr.: 19967 Terminal: B Eval.: LI Up= -127.5kV T1= 1.29µs T2= 43.µs Terminal: -8kV -16kV 2.µs 4.µs 6.µs 8.µs 1µs TB1=2.MS/s 2.µs 4.µs 6.µs 8.µs 1µs TB1=2.MS/s 2.µs 4.µs 6.µs 8.µs 1µs 2.µs 4.µs 6.µs 8.µs 1µs

No. L857 Sheet 3 TB1=2.MS/s % 1% 3% -4kV 5% -8kV 7% 9% -12kV 1% LI: B - FW(1.%) Nr.: 19968 Terminal: B Eval.: LI Up= -126.3kV beta=.1% T1= 1.3µs T2= 43.µs Terminal: TB1=2.MS/s % 1% 3% -4kV 5% -8kV 7% 9% 1% -12kV LI: B - FW(1.%) Nr.: 19969 Terminal: B Eval.: LI Up= -122.3kV beta= 2.7% T1= 1.17µs T2= 44.4µs Terminal: -16kV -16kV 2.µs 4.µs 6.µs 8.µs 1µs TB1=2.MS/s 2.µs 4.µs 6.µs 8.µs 1µs TB1=2.MS/s 2.µs 4.µs 6.µs 8.µs 1µs 2.µs 4.µs 6.µs 8.µs 1µs TB1=2.MS/s % 1% 3% -2kV 5% -4kV 7% 9% -6kV 1% LI: C - RW(5.%) Nr.: 1997 Terminal: C Eval.: LI Up= -62.74kV beta= 2.9% T1= 1.19µs T2= 43.4µs Terminal: TB1=2.MS/s % 1% 3% -4kV 5% -8kV 7% 9% 1% -12kV LI: C - FW(1.%) Nr.: 19971 Terminal: C Eval.: LI Up= -123.7kV beta= 3.% T1= 1.23µs T2= 44.µs Terminal: -8kV -16kV 2.µs 4.µs 6.µs 8.µs 1µs TB1=2.MS/s 2.µs 4.µs 6.µs 8.µs 1µs TB1=2.MS/s 2.µs 4.µs 6.µs 8.µs 1µs 2.µs 4.µs 6.µs 8.µs 1µs TB1=2.MS/s % 1% 3% -4kV 5% -8kV 7% 9% -12kV 1% LI: C - FW(1.%) Nr.: 19972 Terminal: C Eval.: LI Up= -124.8kV beta= 3.% T1= 1.22µs T2= 44.1µs Terminal: TB1=2.MS/s % 1% 3% -4kV 5% -8kV 7% 9% -12kV 1% LI: C - FW(1.%) Nr.: 19973 Terminal: C Eval.: LI Up= -124.8kV beta= 3.% T1= 1.22µs T2= 44.1µs Terminal: -16kV -16kV 2.µs 4.µs 6.µs 8.µs 1µs TB1=2.MS/s 2.µs 4.µs 6.µs 8.µs 1µs TB1=2.MS/s 2.µs 4.µs 6.µs 8.µs 1µs 2.µs 4.µs 6.µs 8.µs 1µs