Dali Lighting Products

Similar documents
400 Series - Mini USB Buccaneer

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Drayton Digistat +2RF/+3RF

Digital input modules

Wireless Home Security Alarm System AM 500

Product and functional description

TruPower-Portable-500W. Solar Starter kit

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

LIEBERT VNSA Installation Sheet

gastroparts WTYCZKI I KONEKTORKI Części zamienne do urządzeń: KAWA GASTROPARTS Sp. J.

LUCCI AIRFUSION QUEST II CEILING FAN

400 Series Buccaneer BUCCANEER POWER. bulgin

Decorative Metal Wiring Accessories in Assorted Plate Finishes

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Installation Manual For Support Call or

HARAX circular connector

ELECTRICAL PRACTICES FOR CONSTRUCTION WORK

Universal MATE-N-LOK Connectors

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

C-Bus Network Monitor

SYSTEM 45. C R H Electronics Design

ISO VIEW OF AX SERIES XLR CABLE CONNECTOR

Advantium 2 Plus Alarm

gesis IP + Heavy Duty Class I, Zone 2

KZ0224UW INSTALLATION MANUAL SURGE PROTECTED CCTV POWER SUPPLY 24V AC, 5 AMP KZMI /12/01

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Electrical connection technologies Electrical connectors Electrical connectors with cable, series. Brochure

Model CS 64 Mini-DIN Cable and Adaptor

V REG.-Nr , Z E Technical data 2-pole 4-pole Rated current 12 A 6 A SCHRACK. Accessories Miniature Relay PT. General Purpose Relays

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app.

PCB TERMINAL BLOCKS. Product Overview

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Emergency lighting units EM powerled

How To Power A Power Supply On A Powerline From A Power Source To A Power Box

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

A&C Solutions: please contact us.

I NTERFACE CABLE ADAPTER MODULE

Electrical Safety Products

Model Number Electrical Compatibility Module Connector Type. M LL-S22 60 cell PV module MC-4 Type 2 Locking

TECHNICAL BRIEF. Commercial PV in Australia and New Zealand Using the Enphase Microinverter System

LED WALL WASHERS SPECIFICATIONS & INSTALLATION GUIDE

Toroidal Conductivity Sensor

This product can be assembled to the baseplate maintaining 5 mm center-to-center spacing. Thus any number of poles can end-to-end stack.

Interface between Eircom Network and Additional Telephone Equipment

Moduline M3 soft wiring solutions

Operating instructions IV / 2007

FIRST STOP SAFETY 1 PAT-IT. Portable Appliance Tester. User Manual. Issue 1.6

High Power Connectors for Power Supply and Power Circuits

Cable Plug acc. to DIN EN , Form A

Electrical Practices for Construction Work

3 IN 1 BATHROOM HEATER

AMPSEAL* Automotive Plug Connector and Header Assembly

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

1. Description. 2. List of Accessories included A B C F G H

The range of rail-mounted terminal blocks. for a perfect electrical installation.

SYSTEM 4C. C R H Electronics Design

SPECIFICATIONS. Recommended Battery sizes (Maintenance) AUTOMOTIVE CCA CCA MARINE MCA MCA DEEP CYCLE 17 55Ah 17 80Ah

KNX R. Rain Sensor. Installation and Adjustment

EASY START SYSTEM. Toni Clark practical scale GmbH EASY START SYSTEM 1

T7560A,B,C Digital Wall Module

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2010

INNOVATION SUPPORTED BY A TRULY SOLID INDUSTRIAL ORGANIZATION.


Modular I/O System Analog and Digital Interface Modules

How To Use A Power Supply On A Powerline 2.2 (Ai)

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

High definition day/night

Standard Buccaneer - Ethernet

7000 Series Buccaneer

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

Series 8146/5-V37 and Series 8150/5-V37

Installation and Operation Guide for PD4000 Series Power Control Center

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Nest Learning Thermostat Installation Guide. Installation step-by-step

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

73 Chevy C10 Ammeter to Volt Gauge Conversion Mark and Michael Olson 2013 Rev 1.0

8146/5 Series Breaker Panelboards

DALI RC BASIC SO. Control unit Operating instructions

Color Mark Sensor with Red or Green LED E3S-VS

Movable Wall 8-Wire Base Electrical System - Product Notes

Digital Keypad Use s Manual

Solar Kit. Complete solution to optimize your photovoltaic system

Standard Buccaneer - USB

SECTION LOW VOLTAGE LIGHTING CONTROLS

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

Original BMW Accessory. Installation Instructions.

HARTING Ethernet Cabling 4-poles Overview

TRIMBLE TX5 3D LASER SCANNER QUICK START GUIDE

Installation Guide. DEVIreg 530. Electronic Thermostat.

CHECKING AND TESTING ELECTRICAL INSTALLING WORK

New XUY roller sensors

BMD16N-SD. version 1.2

NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series. Quick Install Guide

Transcription:

Dali Lighting Products Dali Lighting Products Wiring + Power Solutions cmselectra.com

CMS Quick Flex 5 Pole Cabling Solution The CMS 5 Pole product is a tried and tested system being used into major projects across Australia and New Zealand for the past ten years. The CMS Quick flex cabling solution is a modular five pole softwiring system for Dali, DSI, CBUS, KNX & other systems requiring 5 wire lighting systems. CMS Quick Flex Cabling has its own unique CMS connector system which insures excellent conductivity without the concern of separation at joints. Connectors can only be separated by a tool. CMS Quick Flex Cabling Solution is ideal for the following applications: Education, Retail, Health, Commercial Offices, Airports & Public Sectors. CMS Electracom are able to supply large quantities of our Quick flex products, in most cases, at short notice due to large stockholdings across all major capital cities in Australia and New Zealand. The existing relationships with prominent education institutions, consulting engineers and leading electrical engineers contractors around Australia & New Zealand ensure priority service and proactive response by professionally trained CMS personnel. The use of the CMS Quick flex modular wiring system will drastically reduce installation time for the contractor, delivering you cost savings on site. The 5 Pole modular wiring system is increasing amongst new projects in Australia and New Zealand, and is being specified more frequently by designers and engineers. The energy efficiencies achieved by this form of modular wiring delivers exceptional cost savings, and most importantly sustainable design solution management to the end-user. CMS is committed to contributing to sustainable design At CMS, we have long been of the opinion that environmental issues must be factored into the building design of the future. CMS Electracom is a company committed to Corporate Social Responsibility. How we implement this is through product stewardship, best practise purchasing to meet Australian standards, bringing alternative and reduced environmental impact products to our clients. The Quick Flex system is environmentally friendly, having ROHS and Best Environmental Practice Certification. To ensure your project adheres to Green Star rating, CMS have direct access to supply certified PVC-Free cabling system that have been stringently tested by independent laboratories to meet Green Star compliance. 1 14.1.14

Features & Benefits of CMS 5 Pole Solution Installation time for the contractor is drastically reduced, delivering up to 30% reduction in labour costs Reduction in Waste - Zero onsite material waste Uncomplicated wiring layout, requiring only 4 components for a total solution! Cost & Energy Efficient Safe & Easy Maintenance - isolation during maintenance by removing a single light lead from the bank of T pieces. Simple integration Why deal with CMS Electracom? Supplying wiring & power solutions since 1979 Access to industry trained professionals Ability to supply small to large orders to meet your project schedules Dedicated CMS designers and engineers to support custom solutions Local support by CMS Offices in Sydney, Melbourne, Brisbane, Perth, Auckland, London & Singapore 14.1.14 2

CMS Quick Flex 5 Pole Installation Examples How we work? 1) Design 2) Develop 3) Deliver CMS will take you through the process from concept to completion of wiring and power requirements. CMS experienced team of professionals are trained to provide consultation, estimating & engineering support to all your project needs. 3 14.1.14

Introducing the CMS 5 Pole Solution Image Part Number Description QF1 Starter Socket - Transition between hard and softwiring Tunnel terminals to A5.2 Socket QF2 Interconnecting Lead, 5 core, 3x2.5mm² (A,N,E) & 2x1.5mm² Dali, A5 Socket to Plug QF3 Supply Cable, A5.1 Plug to free end, 5 core, 3x2.5mm² (A,N,E) & 2x1.5mm² Dali. QFS3 A5.2 Socket to free end, 5 core, 3x2.5mm² (A,N,E) & 2x1.5mm² Dali QF3a Supply Cable, A5.1 Plug to free end, 5x1.0mm², maximum 2.5metres For Special Project Pricing, Email Your Plans To estimating@cmselectra.com 14.1.14 4

Image Part Number Description QF3b Supply Cable, A5.1 Plug to B5.2 Socket. Mates with QF6 Light Plug. 3x2.5mm² (A,N,E) & 2x1.5mm² Dali. QF3c Supply Cable, A5.1 Plug to B5.2 Socket. Mates with QF6 Light Plug. 5x1.0mm², maximum 2.5metres QF4 A5 Plug/Socket with tails for direct connection. QF5 Interceptor allows splitting of Dali & Power circuits, i.e. when adding new power circuit. QF6 Lighting Adaptor B5.1 Plug - Push fit termination. Design & Estimating Support for all your Project Needs 5 14.1.14

Image Part Number Description B5T T Adaptor IN/OUT A5 connector and B5.2 Lighting Socket. B5.212 B Type Socket - Rewireable. A5.T T Adaptor 1 IN/2OUT A5 connector. 14.1.14 6

5 Pole Plug & Socket The CMS 5 pole plug base is the latest socket designed by CMS Electracom suitable for Dali, DSI and BMS lighting control networks. The system is used as an alternative to our Quick Flex 5 pole plug and play system. The CMS 5 Pole plug base will also accept a standard Australian 3 pin plug so you can future proof your next installation if a lighting control system is desired at a later stage. QF75 Shown Nearly every new office today incorporates some level of intelligent light level sensors, movement sensors, zoned lighting scene setting and time clocks. In areas where you have exposed ceilings or long distance between light fittings/devices the CMS 5 pole plug base system will provide a convenient and cost effective solution for your next installation. 5 Pin plug shown ORDERING INFORMATION PART NO. QF75WT QF7A-25BK QF7A-100BK QF7A-25WT QF7A-100WT DESCRIPTION Single 10Amp 250v 5 pin Socket - White 2500mm 5pin ROHS Light lead 10amp 5 x 1.0mm² - Black 10,000mm 5pin ROHS Light lead 10amp 5 x 1.0mm² - Black 2500mm 5pin ROHS Light lead 10amp 5 x 1.0mm² - White 10,000mm 5pin ROHS Light lead 10amp 5 x 1.0mm² - White PLEASE CALL US FOR THE MOST UP TO DATE SPECIFICATIONS AND PRICING Notes: - Standard colour for light lead is Black (BK) or White (WT) - Standard colour for 5 Pin socket is White (WT) 7 14.1.14

5 Pole Dali 5pin Plug Base Application Part No: QF75 Step 1: Step 1: Strip cable to recommended length. Step 2: Step 2: Terminate cable wiring into terminal blocks, ensure correct polarity, use break-out areas in socket body to allow cable entry and exit. Step 3: Mount unit using screw mounting holes onto industry standard conduit mounting block or use mounting plate provided. Step 3: Rating - 10A 250V a.c Conductor range - 1.0mm2 to 2.5mm2 solid/ stranded to AS/NZS5000 This product must be installed by a qualified electrician. Disconnect power supply before connecting or disconnecting this product. Active contacts rated low voltage max. 10Amps 14.1.14 8